Search PubMed⌕ Search

Biomedical subjects

S N Krylov

Publications and source records attributed to S N Krylov.

10 recordsLinked to original sources

Protein analysis of an individual Caenorhabditis elegans single-cell embryo by capillary electrophoresis.

We present a simple one-dimensional electrophoretic map of the expressed proteins in a Caenorhabditis elegans embryo. The embryo was taken from an adult nematode, injected into a 50-microm I.D. capillary, and lysed. The proteins were fluorescently labeled and then separated by capillary electrophoresis and detected by laser-induced fluorescence. Over 20 components were resolved in the 22-min separation. The dynamic range was outstanding for this separation, noise in the baseline was less than 0.01% the amplitude of the largest component.

Animals↗

Methyl-beta-cyclodextrin modified micellar electrokinetic capillary chromatography with laser-induced fluorescence for separation and detection of phospholipids.

Micellar electrokinetic capillary chromatography (MECC) with laser-induced fluorescence detection was applied to the separation of amino group-containing phospholipids including phosphatidylethanolamine (PE), phosphatidylserine (PS), lysophosphatidylethanolamine (LysoPE), and lysophosphatidylserine (LysoPS). A fluorogenic dye, 3-(2-furoyl)quinoline-2-carboxaldehyde (FQ), was successfully used to fluorescently label these phospholipids. 4-Fluoro-7-nitrobenzofurazan only produced fluorescent product from LysoPE and PE; signals were not observed from LysoPS and PS. A borax buffer containing sodium deoxycholate modified with methyl-beta-cyclodextrin (methyl-beta-CD) was an excellent MECC system for these phospholipids. Under the optimum conditions, four FQ-labeled phospholipid classes were separated within 8 min. Moreover, each of the PE, PS, LysoPE and LysoPS peaks split into two components corresponding to subclasses with different lengths of the fatty acid chains, but these subclasses were completely resolved only for LysoPE. Detection limits ranged from 0.18 to 1.1 fg (10(-9) - 10(-10) M), which was four- to five-orders of magnitude superior to previously reported CE methods.

Chromatography, Micellar Electrokinetic Capillary↗

Single-cell analysis avoids sample processing bias.

Microscale separation tools such as capillary chromatography and capillary electrophoresis (CE) allow the study of metabolism in individual cells. In this work, we demonstrate that single-cell analysis describes metabolism more accurately than analysis of cellular extracts. We incubated HT29 cells (human colon adenocarcinoma) with a fluorescently labeled metabolic probe. This disaccharide, LacNAc, was labeled with a fluorescent dye, tetramethylrhodamine (TMR). The probe was taken up by the cells and metabolized to a number of products that retained the fluorescent label. We then split the cells into two batches. A cellular extract was prepared from one batch and analyzed by CE with laser-induced fluorescence (LIF) detection. The cells from the second batch were used for single-cell analysis by CE-LIF. Separation and detection conditions were identical for extract and single-cell analyses. We found that the electropherogram obtained by averaging the results from a number of single cells differed significantly from the cell extract electropherogram. Differences were due to sample processing during extract preparation. Disruption of the cells liberated enzymes that were compartmentalized within the cell, which allowed non-metabolic reactions to proceed. The accumulation of these non-metabolic products introduced a bias in the cell extract assay. During single-cell analysis, cells were lysed inside the capillary and the separation voltage was applied immediately to separate the enzymes from their substrates and prevent non-metabolic reactions. This paper is the first to report that CE analysis of single cells provides more accurate metabolic information than the CE analysis of a cellular extract.

Electrophoresis, Capillary↗

Instrumentation for chemical cytometry.

Capillary electrophoresis is ideally suited to chemical analysis of individual cells. Small mammalian somatic cells (approximately 15 microns in diameter) can be analyzed by injecting the intact cell into a capillary, lysing the cell, separating and detecting the cellular components, and reconditioning the capillary prior to the next injection. In this paper, we report on technical improvements to single-cell analysis. We designed an inexpensive multipurpose single-cell injector that facilitates the following: (i) monitoring of injection, (ii) reproducible pressure- or electrokinetic-driven injection of the cell, (iii) complete cell lysis by SDS within 30 s of injection, and (iv) pressure-driven capillary reconditioning. Furthermore, we report on the analysis of glycosylation and glycolysis in single human carcinoma cells (HT29 cell line). The reliability and quality of the analysis is confirmed by comparing electropherograms from single cells and those from purified cell extracts.

Electrophoresis, Capillary↗

Single-cell analysis using capillary electrophoresis: influence of surface support properties on cell injection into the capillary.

Capillary electrophoresis (CE) is an important tool of chemical cytometry. Whole-cell analysis using CE starts with cell injection into the capillary by either siphoning or electroosmosis. However, strong adherence of the cell to the support surface can prevent efficient cell injection and lead to irreproducible analysis. Here we evaluated several surfaces as potential cell supports for HT29 cells (human colon adenocarcinoma). These cells strongly adhered to the surface of untreated glass or polystyrene. Hydrophobic coating with dimethyldichlorosilane (DMS) or Sigmacote did not significantly reduce cell adhesion. In contrast, cell adhesion was reduced significantly when the surface was modified with hydrophilic polymers (hydrogels) such as poly(2-hydrohyethyl methacrylate) (PHEMA) and polyvinyl alcohol (PVA). In addition to their pronounced antiadhesive properties, PHEMA and PVA coatings were the most biocompatible (had highest survival of cells in contact with surface). Hydrogel-coated polystyrene plates were tested as a commercial alternative to hydrogel-coated glass slides. The cell adhesive properties of such plates were similar to those of PHEMA and PVA. However, the biocompatibility of the plates was lower than that of the other surfaces tested. Moreover, in contrast to PHEMA- and PVA-coated glass slides, the plates were sensitive to UV light and therefore should not be used when fluorescent image microscopy with UV excitation precedes CE. The analyses of the data obtained showed that PHEMA- and PVA-coated glass slides were the most suitable cell supports for cell injection into the capillary.

Adenocarcinoma↗

Correlating cell cycle with metabolism in single cells: combination of image and metabolic cytometry.

BACKGROUND: We coin two terms: First, chemical cytometry describes the use of high-sensitivity chemical analysis techniques to study single cells. Second, metabolic cytometry is a form of chemical cytometry that monitors a cascade of biosynthetic and biodegradation products generated in a single cell. In this paper, we describe the combination of metabolic cytometry with image cytometry to correlate oligosaccharide metabolic activity with cell cycle. We use this technique to measure DNA ploidy, the uptake of a fluorescent disaccharide, and the amount of metabolic products in a single cell. METHODS: A colon adenocarcinoma cell line (HT29) was incubated with a fluorescent disaccharide, which was taken up by the cells and converted into a series of biosynthetic and biodegradation products. The cells were also treated with YOYO-3 and Hoechst 33342. The YOYO-3 signal was used as a live-dead assay, while the Hoechst 33342 signal was used to estimate the ploidy of live cells by fluorescence image cytometry. After ploidy analysis, a cell was injected into a fused-silica capillary, where the cell was lysed. Fluorescent metabolic products were then separated by capillary electrophoresis and detected by laser-induced fluorescence. RESULTS: Substrate uptake measured with metabolic cytometry gave rise to results similar to those measured by use of laser scanning confocal microscopy. The DNA ploidy histogram obtained with our simple image cytometry technique was similar to that obtained using flow cytometry. The cells in the G(1) phase did not show any biosynthetic activity in respect to the substrate. Several groups of cells with unique biosynthetic patterns were distinguished within G(2)/M cells. CONCLUSIONS: This is the first report that combined metabolic and image cytometry to correlate formation of metabolic products with cell cycle. A complete enzymatic cascade is monitored on a cell-by-cell basis and correlated with cell cycle.

Biodegradation, Environmental↗

Peroxidase-catalyzed co-oxidation of indole-3-acetic acid and xanthene dyes in the absence of hydrogen peroxide.

The effect of xanthene dyes on the chemiluminescence from the aerobic indole-3-acetic acid (IAA) oxidation, catalyzed by horseradish peroxidase (HRP), was studied. The rate of IAA oxidation and dye destruction were controlled. It was found that the addition of dyes to the IAA/HRP/O2 system resulted in: (i) the appearance of emission in the region of dye fluorescence, (ii) an increase of the total chemiluminescence intensity, (iii) a decrease of the emission duration, (iv) the acceleration of IAA oxidation, and (v) slow bleaching of the dyes. The experimental results lead to the conclusion that all spectral and kinetic variations of the chemiluminescence from the IAA/HRP/O2 system which are caused by the addition of xanthene dyes, are the result of IAA-dye co-oxidation. Earlier published reports regarding energy transfer from electronically excited species, generated in the IAA/HRP/O2 system, to the xanthene dyes seem to be erroneous.

Coloring Agents↗