Search PubMed⌕ Search

PubMed · 10816297

Infant buttoned device.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P S Rao, E B Sideris. 2000. Infant buttoned device.. https://doi.org/10.1002/(sici)1522-726x(200005)50%3A1%3C125%3A%3Aaid-ccd27%3E3.0.co%3B2-l

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Validation of the local shortening function as assessed by nonfluoroscopic electromechanical mapping: a comparison with computerized left ventricular angiography.

BACKGROUND: Nonfluoroscopic electromechanical mapping (NEM) has been proposed as a new technique for the evaluation of electrical and mechanical functioning of the myocardium. In this system, linear local shortening (LLS) is the parameter used for assessment of local mechanical properties. To validate this parameter, we compared LLS with regional wall motion (RWM) data derived from contrast left ventriculograms acquired in the same patients. METHODS AND RESULTS: Angiographic left ventricular RWM was analyzed using the area-length method. The right anterior oblique view was divided in five segments, the left anterior oblique view in two. Through a comparison of enddiastolic and endsystolic areas drawn from a computer-defined central point to the respective wall delineation, RWM was calculated as change in area. In the first approach, we compared area changes to comparable NEM segments. In the second part of the study, LLS values for normokinetic, hypokinetic, akinetic and dyskinetic segments were correlated to the change in angiographic RWM. In the first approach, the overall comparison of segments yielded a correlation coefficient of 0.67 (P<0.0005). In the second part of the study, differences in LLS values between dyskinetic (LLS=-3.68+/-8.86%), akinetic (2.84+/-3.96%), hypokinetic (9.35+/-4.27%) and normokinetic (13.66+/-7.98%) segments were highly significant (overall ANOVA: P<0.0005). CONCLUSION: NEM is a powerful tool for invasive electromechanical assessment of myocardial function.

Angiography↗

Effects of the Dor procedure on left ventricular dimension and shape and geometric correlates of mitral regurgitation one year after surgery.

OBJECTIVES: In the present study we retrospectively analyzed ventriculographic data from symptomatic patients after myocardial infarction who underwent the Dor procedure (endoventricular circular patch plasty repair) to evaluate left ventricular shape 1 year after the operation and to analyze the geometric correlates of late mitral regurgitation. METHODS: Forty-four patients with previous transmural anterior myocardial infarction comprised the study group. Left ventricular volumes, global left ventricular systolic and diastolic sphericity, the extent of wall motion abnormalities, and the presence and degree of mitral regurgitation were analyzed before and 1 year after operation. RESULTS: Comparing preoperative diastole to systole within the cardiac cycle, left ventricular shape becomes more elliptical in systole than it was in diastole (eccentricity index closer to 1). The intervention leads to an increased diastolic sphericity, but for each cardiac cycle, the systolic shape is more elliptical relative to its diastolic counterpart in respect to basal conditions. Mitral regurgitation was detected after operations in 17 patients; 14 of them did not have mitral regurgitation before operations. Patients with late mitral regurgitation had greater preoperative volumes and more spherical chamber than did patients without late mitral regurgitation. CONCLUSIONS: Despite a more spherical postoperative left ventricular chamber, systolic pump function improves after the Dor procedure, mainly for the improvement in inferior wall shortening. The presence of late mitral regurgitation is relatively frequent in this series of patients, and this emphasizes the importance of a more accurate quantitative evaluation of preoperative functional mitral regurgitation to repair the valve when appropriate. Geometric correlates of late mitral regurgitation appeared to be greater chamber sphericity and larger ventricular volumes preoperatively.

Angiography↗