Search PubMed⌕ Search

PubMed · 10435521

Virtual light field projection for CT-simulation.

Abstract

We report a method to project a virtual light field over the patient during CT-simulations of external beam radiotherapy. It can be used to perform all the tasks associated with the physical light field of a conventional simulator. The system consists of a three-dimensional sonic digitizer interfacing with a window-based software on a personal computer. The digitizer can provide the three-dimensional coordinates of any point in space accessible by the digitizer probe. When these coordinates are transformed into the beam's eye view, the position of the digitized point relative to the beam can readily be displayed. Thus, the system establishes a virtual light field in space, which can be "seen" only by the digitizer probe. For any digitized point, the system can immediately show, by the beam's eye view display, whether the point is inside the field, outside of the field, or on the field border. Moreover, this virtual field projection allows one to evaluate external target coverage (or external normal tissue sparing) conveniently and interactively. By simply digitizing the concerned area and viewing its position in the beam's eye view display, one can immediately assess the coverage and if necessary, modify the treatment field accordingly. The system also provides an efficient and essential procedure in CT-simulations for marking treatment portals on the patient. By cruising the digitizer probe on the patient's skin surface under visual and audio guidances, one can promptly find the projection of the field center, field corners, etc., on the patient. Measurements have been performed to study the accuracy of the GP-12 sonic digitizer using rigid phantoms. Based on the measured data, the overall accuracy of the portal localization system is estimated to be +/-2 mm. The system has been in clinical use for our CT simulator.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H M Lu, L Chin. 1999. Virtual light field projection for CT-simulation.. https://doi.org/10.1118/1.598616

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Integrated flow-injection processing for on-line quantification of plasmid DNA during cultivation of E. coli.

An integrated flow-injection processing (FIP) system for the quantification of plasmids during cultivation is described. The system performs on-line sampling, cell lysis, and quantification of plasmids in an integrated manner during cultivation of E. coli. The system was operated by using a miniaturized expanded-bed column which can be used for handling samples containing cells and cell debris without interfering with the binding analysis. Two types of detectors (one measuring UV absorbance at 254 nm and a fluorometer) are used for on-line plasmid detection. The system was developed using standard solutions and it was successfully applied in monitoring plasmid contents during a cultivation of E. coli.

Calibration↗

Field portable XRF analysis of environmental samples.

One of the critical factors for successfully conducting contamination characterization, removal, and remedial operations at hazardous waste sites is rapid and appropriate response to analyze samples in a timely fashion. Turnaround time associated with off-site analysis is often too slow to support efficient utilization of the data. Field portable X-ray fluorescence (FPXRF) techniques provide viable and effective analytical approaches to meet on-site analysis needs for many types of environmental samples. Applications include the in situ analysis of metals in soils and sediments, thin films/particulates, and lead in paint.

Calibration↗