Quality control in the pulmonary function laboratory.

Abstract

The addition of computers to pulmonary function laboratories has reduced quality-control problems. After standards for a test have been selected, the computer can enforce adherence to them. The computer can be programmed to perform periodic calibration checks and other self-diagnostic procedures to ensure that instrumentation and human errors have not gone undetected. The computer can be used to verify that reference values are within acceptable limits and that results for a particular patient are at least internally consistent. The computer greatly reduces the number of measurements and calculations that must be done by hand and therefore improves laboratory efficiency and reduces the probability of human error. Quality-control samples can be processed more frequently with the use of a computer because this task consumes less time than when done by laboratory personnel. Some disadvantages of quality control that have appeared since the introduction of the computer are the potential for undetected failure of computer hardware and software, a risk that has increased with the increase in software complexity, and the potential for the loss of large amounts of information because of its being stored on a single digital medium. To effect quality control in the pulmonary function laboratory one should (1) ensure that procedures and software conform to standards, (2) follow routine calibration-check procedures, (3) check test results for internal consistency and for consistency with other test results, (4) conduct periodic testing of a quality-control subject or reference sample, (5) continually evaluate software performance, (6) carefully evaluate changes in instrumentation and software, and (7) maintain duplicate copies of data on different types of mass storage media.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J L Hankinson. 1982. Quality control in the pulmonary function laboratory.. https://pubmed.ncbi.nlm.nih.gov/10315285/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗