Search PubMed⌕ Search

PubMed · 10222279

JavaScope: A Web-based TEM control interface.

Abstract

JavaScope is a Web-based java applet that implements an "exploration/browser" tool for operating a Philips CM200 transmission electron microscope and viewing digital images remotely. The primary use of the application is as a collaborative tool for remote consultations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Kisseberth, G Brauer, B Grosser, C S Potter, B Carragher. JavaScope: A Web-based TEM control interface.. https://doi.org/10.1006/jsbi.1999.4084

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitative, chemically specific imaging of selenium transformation in plants.

Quantitative, chemically specific images of biological systems would be invaluable in unraveling the bioinorganic chemistry of biological tissues. Here we report the spatial distribution and chemical forms of selenium in Astragalus bisulcatus (two-grooved poison or milk vetch), a plant capable of accumulating up to 0.65% of its shoot dry biomass as Se in its natural habitat. By selectively tuning incident x-ray energies close to the Se K-absorption edge, we have collected quantitative, 100-microm-resolution images of the spatial distribution, concentration, and chemical form of Se in intact root and shoot tissues. To our knowledge, this is the first report of quantitative concentration-imaging of specific chemical forms. Plants exposed to 5 microM selenate for 28 days contained predominantly selenate in the mature leaf tissue at a concentration of 0.3-0.6 mM, whereas the young leaves and the roots contained organoselenium almost exclusively, indicating that the ability to biotransform selenate is either inducible or developmentally specific. While the concentration of organoselenium in the majority of the root tissue was much lower than that of the youngest leaves (0.2-0.3 compared with 3-4 mM), isolated areas on the extremities of the roots contained concentrations of organoselenium an order of magnitude greater than the rest of the root. These imaging results were corroborated by spatially resolved x-ray absorption near-edge spectra collected from selected 100 x 100 microm(2) regions of the same tissues.

Image Processing, Computer-Assisted↗

Two-photon autofluorescence microscopy and spectroscopy of Antarctic fungus: new approach for studying effects of UV-B irradiation.

We combined two-photon fluorescence microscopy and spectroscopy to provide functional images of UV-B (280-315 nm) induced stress on an Antarctic fungus. Two-photon excitation microscopy was used to characterize the distribution of autofluorescence inside the spore and the hyphae of the fungus. The imaging analysis clearly shows that the autofluorescence response of spores is higher than that of hyphae. The imaging analysis at different depths shows that, strikingly enough, the spore autofluorescence originates from the cell wall and membrane fluorophores. The spectroscopic results show moreover that the fluorescence spectra of spores are redshifted upon UV-B irradiation. Tentative identification of the chromophores involved in the autofluorescence response and their biological relevance are also discussed on the basis of a previous steady-state fluorescence spectroscopic study performed on both whole spore suspension and organic-soluble extracts.

Image Processing, Computer-Assisted↗

Omega-space adaptive acquisition technique for magnetic resonance imaging from projections.

An omega-space adaptive acquisition technique for MRI from projections is presented. It is based on the evaluation of the information content of a set composed of four initial projections, measured at angles 0 degrees, 45 degrees, 90 degrees, and 135 degrees, followed by the selection of new angles where the information content is maximum. An entropy function is defined on the power spectrum of the projections that is useful for evaluating the information content of each projection. The method makes it possible to reduce the total acquisition time with little degradation of the reconstructed image and it adapts to the arbitrary shape of the sample. For this reason, it can be particularly useful in those applications where acquisition from projections is strongly recommended to save acquisition time, such as functional MRI, imaging of species having very short T(2), or angiography. The method has been tested both on simulated data and on experimental data collected by a commercial MRI apparatus. The method has also been compared to the regular acquisition method, that is, the standard acquisition method in MRI from projections.

Image Processing, Computer-Assisted↗