Search PubMed⌕ Search

PubMed · 10171496

Reducing pathology test misuse.

Abstract

Our laboratory serves a 450-bed acute care hospital in the rapidly growing Gold Coast region. The problem facing the department comprised an almost 10 per cent yearly increase in patient numbers in the face of budgetary constraints and pressure to increase efficiency. In January and February 1992 a vigorous effort was made to reduce pathology test numbers without compromising quality of patient care. The approach adopted involved targeting 'unnecessary' tests, defined as those investigations that would not affect a clinician's management of the patient. A team effort by laboratory scientific staff and heads of clinical departments was aimed at scrutinizing the ordering patterns of junior medical staff, who generate most of the test requests. The result was a 'test per patient' figure of 8.2 for both months, calculated as the number of tests on each request form received. In comparison, for January and February of the preceding four years, 1988 to 1991, the number of tests per patient fluctuated between 9.9 and 11.8. Patterns of unnecessary ordering that emerged included duplicate ordering of identical tests due to poor communication between house-staff, too frequent repeats of tests (for example, daily liver function tests), crossmatch where low transfusion likelihood would make group-and-hold appropriate, tests generated by nursing staff, and numerous others where the result would not affect management (or indeed even be looked at!). The nearly 20 per cent drop in tests does not include those instances where all tests on a request form were disallowed and the encounter therefore not included as a 'patient' statistic.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Grantham, S Weinstein. 1993. Reducing pathology test misuse.. https://pubmed.ncbi.nlm.nih.gov/10171496/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The 1998-1999 collaborative exercises and proficiency testing program on DNA typing of the Spanish and Portuguese Working Group of the International Society for Forensic Genetics (GEP-ISFG).

A total of 28 laboratories (labs) submitted results for the 1998 collaborative exercise and the proficiency testing program of the Spanish and Portuguese Working Group of the International Society for Forensic Genetics (GEP-ISFG) group. This number increased to 46 labs in 1999. Six bloodstains were submitted, each one with 200 microl soaked in cotton except the sample no. 6 submitted for DNA quantification which had 2 microl. One of the samples was a mixed stain. A paternity testing case and a criminal case in the 1998 trial (GEP'98) and two paternity testing cases in 1999 (GEP'99) were included and the statistical evaluation of the evidence was requested in both cases. In the GEP'99 trial, a theoretical paternity testing case was included. A total of 52 DNA genetic markers were used by the participants in the GEP'98 trial, which increased to 101 in GEP'99. Despite this increasing number of participating labs, results remained quite satisfactory. All the labs used PCR-based DNA polymorphisms with an increasing number of markers, obtaining good results. SLPs were used by a decreasing number of labs but the results indicated a good level of expertise despite the different protocols used. Good results were also obtained for mtDNA despite the difficulties presented by the samples due to the presence of length heteroplasmy in some samples in both trials. The detection of heteroplasmy should, however, be improved. Similar conclusions were reached for both, the paternity and the criminal case by all the labs. Common methodologies for the statistical evaluation of the paternity case were used and the paternity index and the probability of paternity (with an a priori value of 0.5) reported by most of the labs. Also, a great uniformity was found in the evaluation of the criminal case despite the lack of a specific hypothesis in the design of the exercise. Some errors in statistical programs or in calculations were detected in a theoretical paternity case included in the GEP'99 trial for statistical analysis.

Clinical Laboratory Techniques↗

Extraction of glyphosate by a supported liquid membrane technique.

The possible application of the supported liquid membrane (SLM) technique for the extraction of glyphosate is presented. For the extraction of this compound the SLM system has been applied with utilisation of Aliquat 336 as a cationic carrier incorporated into the membrane phase. The extraction efficiency of glyphosate [N-(phosphonomethyl)glycine] is dependent on the donor phase pH, carrier concentration in the organic phase and NaCl concentration in the acceptor phase. The optimal extraction conditions are: donor phase pH>11, acceptor phase of 2 M NaCl solution and the organic phase composed of 20% (w/w) Aliquot 336 solution in di-hexyl ether. Counter-coupled transport of chloride anions from the acceptor phase to the donor phase is a driving force of the mass transfer in this system.

Clinical Laboratory Techniques↗