Maximum likelihood estimation in calibrating a stereo camera setup.

Abstract

Motion and deformation of the cardiac wall may be measured by following the positions of implanted radiopaque markers in three dimensions, using two x-ray cameras simultaneously. Regularly, calibration of the position measurement system is obtained by registration of the images of a calibration object, containing 10-20 radiopaque markers at known positions. Unfortunately, an accidental change of the position of a camera after calibration requires complete recalibration. Alternatively, redundant information in the measured image positions of stereo pairs can be used for calibration. Thus, a separate calibration procedure can be avoided. In the current study a model is developed that describes the geometry of the camera setup by five dimensionless parameters. Maximum Likelihood (ML) estimates of these parameters were obtained in an error analysis. It is shown that the ML estimates can be found by application of a nonlinear least squares procedure. Compared to the standard unweighted least squares procedure, the ML method resulted in more accurate estimates without noticeable bias. The accuracy of the ML method was investigated in relation to the object aperture. The reconstruction problem appeared well conditioned as long as the object aperture is larger than 0.1 rad. The angle between the two viewing directions appeared to be the parameter that was most likely to cause major inaccuracies in the reconstruction of the 3-D positions of the markers. Hence, attempts to improve the robustness of the method should primarily focus on reduction of the error in this parameter.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Muijtjens, J M Roos, T Arts, A Hasman. 1999. Maximum likelihood estimation in calibrating a stereo camera setup.. https://doi.org/10.1118/1.598518

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ten years of tension: single-molecule DNA mechanics.

The basic features of DNA were elucidated during the half-century following the discovery of the double helix. But it is only during the past decade that researchers have been able to manipulate single molecules of DNA to make direct measurements of its mechanical properties. These studies have illuminated the nature of interactions between DNA and proteins, the constraints within which the cellular machinery operates, and the forces created by DNA-dependent motors.

Biomechanical Phenomena↗

A neuro-fuzzy model for estimating electromyographical activity of trunk muscles due to manual lifting.

The main objective of this study was to develop a hybrid neuro-fuzzy system for estimating the magnitude of EMG responses of 10 trunk muscles based on two lifting task variables (trunk velocity and trunk moment) as model inputs. The input and output variables were represented using the fuzzy membership functions. The initial fuzzy rules were generated by the neural network using true EMG data. Two different laboratory-derived EMG data sets were used for model development and validation, respectively. The mean absolute error (MAE) between the actual and model-estimated normalized EMG values was calculated. Across all muscles, the average value of MAE was 8.43% (SD=2.87%) of the normalized EMG data. The larger absolute errors occurred in the left side of the trunk, which exhibited higher levels of muscular activity. Overall, the developed model was capable of estimating the normalized EMG values with average value of the mean absolute differences of 6.4%. It was hypothesized that model performance could be improved by increasing the number of inputs, including additional task variables as well as the subjects' characteristics.

Biomechanical Phenomena↗

Subdural haemorrhage sustained in a baby-rocker? A biomechanical approach to causation.

An unconscious 8 weeks old infant was admitted to hospital and found to have bilateral, subdural and retinal haemorrhages. He died the following day. The explanation for the subdural haemorrhage put forward by his carers was that the infant had been in a baby-rocker and that the carers had seen the rocker being rocked vigorously by their 14 months old daughter on two separate occasions. This paper describes the biomechanics of an infant model in the particular baby-rocker used and determines the maximum forces generated, comparing them with the 'forces' thought to be compatible with the causation of subdural haemorrhage.

Biomechanical Phenomena↗