Search PubMedSearch

subject

Neurocritical care

Neurocritical care: explore 3 source-linked works published from 2026 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: pubmed. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

Aneurysmal subarachnoid hemorrhage care in a middle-income public healthcare system: A real-world neurocritical care cohort.

BACKGROUND AND PURPOSE: Although aneurysm treatment capacity has expanded worldwide, outcomes after aneurysmal subarachnoid hemorrhage (aSAH) remain strongly influenced by neurocritical care (NCC) delivery, referral pathways, and access to specialized treatment. Contemporary data describing real-world aSAH care in resource-limited healthcare systems remain scarce. We aimed to characterize treatment patterns, NCC delivery, complications, and outcomes in a large Brazilian public referral center. METHODS: This retrospective cohort study included consecutive adults with confirmed aSAH admitted between June 2018 and March 2022 to a high-volume Brazilian tertiary referral center. Only patients admitted within five days of symptom onset were included. Demographic, clinical, radiological, treatment, complication, and outcome data were extracted from institutional records. Primary outcomes were in-hospital mortality and 3-month functional outcome assessed by the modified Rankin Scale (mRS). RESULTS: Seventy-four patients were included. Disease severity was high, with 45% presenting WFNS grades 4-5, 73% modified Fisher grade 4 hemorrhage, and 64% hydrocephalus. Endovascular treatment was performed in 73% of cases, and median time from admission to aneurysm treatment was 1 day. Despite early treatment capability, only 28% of patients were admitted to an ICU within 48 h, while 38% never received ICU care. Delayed cerebral ischemia occurred in 43%, radiologic vasospasm in 58%, ventriculitis in 22%, and infectious complications in 57%. External ventricular drainage was required in 42%, and vasoactive drugs were used in 85%. In-hospital mortality was 42%, and 66% had unfavorable 3-month outcomes (mRS 4-6). CONCLUSIONS: This real-world cohort highlights the substantial neurocritical care burden of aSAH in a middle-income public healthcare system. Despite timely access to definitive aneurysm treatment, patients experienced frequent neurological and systemic complications, emphasizing that contemporary aSAH care extends well beyond aneurysm occlusion.

Humans

Association of time-averaged systemic immune-inflammation indices with in-hospital mortality after intracerebral hemorrhage: a retrospective study.

BACKGROUND: Systemic inflammation plays a central role in secondary brain injury following intracerebral hemorrhage (ICH). Although inflammatory indices such as the neutrophil-to-lymphocyte ratio (NLR), systemic immune-inflammation index (SII), and systemic inflammation response index (SIRI) are linked to poor outcomes, their associations with mortality are commonly assumed to be linear, potentially overlooking nonlinear patterns where mortality risk rises steeply at higher levels. METHODS: We conducted a retrospective study using the MIMIC-IV database, including 440 patients with non-traumatic ICH who were alive and remained in the ICU for at least 72&#xa0;h after admission. Mean NLR, SII, and SIRI were calculated from measurements obtained during this period. Multivariable logistic regression and restricted cubic spline (RCS) analyses were applied to assess their independent and nonlinear associations with in-hospital mortality. Model discrimination and calibration were internally validated using 1,000 bootstrap resamples. RESULTS: The in-hospital mortality rate was 26.1%. After multivariable adjustment, NLR and SIRI remained independently associated with mortality. Patients in the highest SIRI quartile had the highest risk of death (aOR&#xa0;=&#xa0;5.12; 95% CI: 2.57-12.24; p&#xa0;<&#xa0;0.001). RCS analysis revealed a significant nonlinear association between SIRI and mortality (p-nonlinearity&#xa0;<&#xa0;0.05), showing a steep risk increase at higher SIRI levels. Adding SIRI to the base model provided a modest improvement in discrimination (AUC 0.762 to 0.785, p&#xa0;=&#xa0;0.045) and significantly improved risk reclassification (cNRI&#xa0;=&#xa0;0.4778, p&#xa0;<&#xa0;0.001; IDI&#xa0;=&#xa0;0.0240, p&#xa0;=&#xa0;0.0151). CONCLUSIONS: Among patients with ICH who met the 72-hour eligibility criterion, higher 72-hour average SIRI was independently associated with in-hospital mortality. As a time-averaged measure, SIRI should be interpreted as a dynamic marker integrating the initial inflammatory state and the early clinical course rather than as a purely baseline prognostic factor. Although adding SIRI to the base model modestly improved discrimination and risk reclassification, it should be considered a candidate prognostic marker requiring external validation before clinical application.

Humans

Alarms and alarm management with automated versus conventional ventilation in neurocritical care patients.

INTRODUCTION: False or clinically irrelevant alarms are a major driver of ICU alarm fatigue and nursing workload. Ventilator alarms make up a large share, and although automated ventilation modes can reduce manual adjustments, their effect on alarm burden is still unclear. This issue can be particularly relevant in neurocritical care patients, where precise ventilator and alarm management is imperative for patient safety. OBJECTIVES: This explorative post hoc analysis of a randomized clinical trial compared alarm frequency and management between automated ventilation and conventional ventilation in neurocritical care patients. METHODS: Ventilator alarms and manual ventilator changes were captured continuously from the ventilator for up to 24&#xa0;h per patient. The primary endpoint was a composite of workload-relevant alarms; with alarm management interventions at the ventilator as a key secondary outcome. Additional endpoints included redundant alarms, alarm duration and ventilator management. RESULTS: 13 patients received automated ventilation and 24 received conventional ventilation. No difference was observed in workload-relevant alarm frequency between automated and conventional ventilation (3.28 [2.87 to 4.30] vs 3.73 [1.66 to 7.33] alarms per hour; P&#xa0;=&#xa0;0.81), while alarm management interventions at the ventilator were lower with automated ventilation (0.14 [0.10 to 0.15] vs 0.21 [0.17 to 0.31] interventions per hour; P&#xa0;=&#xa0;0.01). Other alarm frequencies, duration of alarms and ventilator management were similar. CONCLUSIONS: In this exploratory post hoc analysis of a randomized clinical trial in neurocritical care patients during the early phase of mechanical ventilation, automated ventilation did not reduce the frequency of total or workload-relevant alarms, nor their duration, but was associated with fewer alarm management interventions compared to conventional ventilation. IMPLICATIONS FOR CLINICAL PRACTICE: Automated ventilation may not reduce alarm frequency in neurocritical care patients, but the observed reduction in alarm-related bedside interventions suggests a potential benefit for nursing workload.

Humans
Compare source metadata on this page

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.