Search PubMedSearch

subject

Colorimetry

Colorimetry: explore 3 source-linked works published from 2026 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: pubmed. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

A smartphone-integrated Pt@Cu-HCF nanozyme-based paper sensor for on-site determination of total antioxidant capacity in marine oils.

Total antioxidant capacity (TAC) serves as a key indicator for evaluating the nutritional quality of foods. In this study, we designed a platinum-embedded copper hexacyanoferrate (denoted as Pt@Cu-HCF) nanozyme that exhibits high oxidase-like activity, efficiently catalyzing the oxidation of chromogenic substrates to generate robust colorimetric signals. Antioxidants quench hydroxyl radicals (∙OH) produced during the catalytic process, leading to a concentration-dependent suppression of the color signal. Leveraging this mechanism, a smartphone-integrated, colorimetric paper sensor for on-site TAC quantification was developed, using vitamin E as the calibration standard. The sensor was applied to determine TAC in fish oil, algal oil, and krill oil, demonstrating a linear response range of 9.78-312.5 μM and a limit of detection (LOD) of 6.41 μM. Validation using real-world marine oil samples showed excellent agreement with a commercial assay kit, confirming the reliability and practical applicability of this portable sensor for TAC measurement in complex biological matrices.

Antioxidants

Artificial neural network data fusion-mediated dual-mode sensor based on Fe3O4@PdIr for Salmonellatyphimurium detection in food.

Salmonella Typhimurium (S. typhimurium) is a major foodborne pathogen that poses a serious threat to public health. In this study, a colorimetric/electrochemical dual-mode biosensor assisted by artificial neural network (ANN) was developed for the sensitive detection of S. typhimurium. Fe3O4@PdIr nanocomposites with enhanced peroxidase-like activity and electrochemical performance were prepared and conjugated with an aptamer specific to S. typhimurium to obtain Fe3O4@PdIr-Apt. Through the sandwich binding of Fe3O4@PdIr-Apt and Apt to the target, the nanocomposites were attached to microplates or Au electrodes, thereby generating colorimetric and electrochemical signals. The ANN model deeply resolved the complex nonlinear relationship between the dual signals, enabling mutual correction and ultimately performing data fusion to output a single detection result, which significantly reduced the mean square error while improving detection sensitivity and reliability. This sensor exhibited a wide linear range of 2.7-2.7 × 108 CFU/mL and a low detection limit of 1.66 CFU/mL. Additionally, this method was successfully applied to the detection of S. typhimurium in pork and milk, with a recovery rate of 95.19% ∼ 104.07%. It indicated that the constructed sensor holds great practical potential for S. typhimurium detection.

Neural Networks, Computer

Measurement of low-density lipoprotein cholesterol and other circulating lipids in Brazil: a systematic literature review.

Accurate laboratory assessment of circulating lipids underpins cardiovascular risk stratification, yet clinical interpretation depends not only on the assays but on the formula chosen to estimate low-density lipoprotein cholesterol (LDL-C). This review integrates the 2019-2025 evidence on laboratory methods for triglycerides (TG), total cholesterol (TC), and high-density lipoprotein cholesterol (HDLC), and on the formulas estimating LDL-C, VLDL-C, and non-HDL cholesterol, to determine how these should be measured, reported, and harmonized in Brazil, where lipid thresholds are adapted from international consensus. A PRISMA 2020 systematic search (PROSPERO CRD420251241064) of PubMed/MEDLINE, Scopus, SciELO, LILACS, Web of Science, and Embase retrieved 57,915 records; after removing 38,210 duplicates, 19,705 titles/abstracts were screened, 312 full texts assessed, and 25 sources included. Enzymatic colorimetric assays remain standard for TG, TC, and HDLC. For LDL-C, Martin/Hopkins classifies more accurately than Friedewald (89.6% vs 83.2% correct categorization in 5,051,467 patients), particularly at high TG and low LDL-C, while Sampson/NIH and modified Sampson/NIH extend reliable estimation into hypertriglyceridemia and very low LDL-C; direct measurement is reserved for TG beyond the validated range. Although the review centers on the Friedewald, Martin/Hopkins, and Sampson/NIH families that dominate guideline practice, other published equations exist and are addressed in context. In Brazil, atherogenic-lipid thresholds are risk-based decision limits rather than reference intervals; national surveys describe lipid distributions but were not designed to establish them. Analytical standardization through traceability programs, multicenter validation of formulas, and-where the distribution-based construct applies (HDLC, pediatrics)-nationally derived reference intervals are priorities for equitable cardiovascular risk assessment in Brazil.

Humans
Compare source metadata on this page

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.