Experimental evaluation and clinical application of intraoperative counterpulsation without balloon pumping.

Cardiac assistance in the form of counterpulsation (CP), created by intraaortic balloon pumping (IABP), has recently been utilized to wean patients from cardiopulmonary bypass (CPB) after conventional modalities have failed. The use of IABP, however, is often delayed because it is not part of the standard CPB setup and requires an additional cutdown, an arterial graft, and the retrograde insertion of a foreign body into the arterial tree. To eliminate the disadvantages of IABP, an alternate technique for CP has been developed. A pneumatially actuated external blood reservoir connected via a "Y" connector to the standard arterial line of the CPB circuit can provide pulsatile flow, and when synchronized with the EKG, CP with or without CPB. Experimental evaluation with dogs comparing this technique with IABP has shown that the former can create comparable CP pressure curves to the latter. The technique was applied to 11 patients undergoing either aorto-coronary bypass surgery and/or valvular surgery. Two of the 11 patients could come off CPB only with the assistance of CP. Coronary bypass graft flow, when measured, increased by 25% due to CP in two out of seven patients. The arterial CP technique has proven to be easily adapted to clinical settings and provides immediate and effective CP when required.

Animals↗

A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow.

In general, roller pumps are set almost occlusively despite evidence that nonocclusive settings cause less hemolysis. Almost-occlusive settings are used because of the concern that forward flow would not be accurately known if retrograde flow were allowed to occur through a nonocclusive gap. This article presents a dynamic method for setting roller pumps nonocclusively that overcomes the many difficulties of the "drop method" for setting occlusion. Studies were conducted to determine the effect of nonocclusive settings on pump flow and hemolysis generated; the results suggest that roller pumps can and should be set more nonocclusively than is the currently accepted standard to reduce pump related hemolysis without greatly affecting pump performance. The dynamic method allows retrograde flow to be easily predicted and corrected with an increase in pump speed.

Extracorporeal Circulation↗