Search PubMed⌕ Search

Biomedical subjects

Y Oshida

Publications and source records attributed to Y Oshida.

At least 55 records · Page 3Linked to original sources

Intramuscular 3-hydroxybutyrate levels after 60 tetani/min contraction in diabetic and non-diabetic rats.

Post-exercise hyperketonemia in poorly-controlled diabetic patients is a well recognized phenomenon, but because studies concerning changes in ketone body metabolism in muscle during and/or after exercise are scarce, we measured the intramuscular 3-hydroxybutyrate (3-OHBA) and lactate concentrations in 12 diabetic (streptozotocin-induced; 60 mg/kg, ip) and 13 non-diabetic control rats before and after a 1-h muscle contraction. One thigh tetanic contraction was elicited at a tetanic frequency of 60 tetani/min and the other thigh was kept resting. We used a microdialysis technique in both quadriceps muscles, vastus lateralis, and the right jugular vein. Blood flow in both femoral muscles was also monitored before and after contraction. Dialysate 3-OHBA and lactate levels in contracting and non-contracting muscles and in blood showed a significant increase after contraction (P<0.05) in diabetic rats. In control rats there was no significant change in dialysate 3-OHBA or the lactate concentration in contracting and non-contracting muscles or in blood before and after contraction. A significant increase in contracting muscle blood flow was observed only for the first 5 min after contraction in diabetic and control rats. These results suggest that 3-OHBA uptake in contracting muscle is reduced, and that this phenomenon may play a role in post-exercise ketosis in diabetes.

3-Hydroxybutyric Acid↗

Corrosion behavior of sensitized duplex stainless steel.

The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.

Corrosion↗

Activities of liver pyruvate dehydrogenase complex and 3-hydroxyacyl-CoA dehydrogenase in sand rat (Psammomys obesus).

The sand rat (Psammomys obesus) is an animal model for non-insulin dependent diabetes mellitus, which is induced by a regular chow diet. The total activity of liver pyruvate dehydrogenase complex in the sand rats under normoglycemic and normoinsulinemic conditions was one half as high as that in the albino rats, but the activity of liver 3-hydroxyacyl-CoA dehydrogenase was more than 4 times greater in the former than in the latter, suggesting a low capacity for glucose oxidation and a high capacity for fatty acid oxidation in the sand rats. These metabolic conditions may be related to the predisposition of the animals towards diabetes. Diet-induced diabetes in the sand rats resulted in decreasing the active form of liver pyruvate dehydrogenase complex and in increasing the activity of liver 3-hydroxyacyl-CoA dehydrogenase, suggesting that the diabetic conditions further suppress glucose oxidation and promote fatty acid oxidation.

3-Hydroxyacyl CoA Dehydrogenases↗

Effects of aging on the activities of pyruvate dehydrogenase complex and its kinase in rat heart.

Effects of aging on the activities of heart pyruvate dehydrogenase complex and pyruvate dehydrogenase kinase were examined using 7, 35 and 60 wk old rats. Aging did not affect the total activity of pyruvate dehydrogenase complex but decreased the activity state (percentage of active form) of the complex in rats under the fed condition (52%, 36% and 26% for 7, 35 and 60 wk old rats, respectively). This decrease in the complex activity with aging was suggested to be associated with an age-related decrease in the blood glucose disposal. Starvation for 24 h decreased the activity state to less than 3% in all of the age groups. The activity of pyruvate dehydrogenase kinase associated with the complex was not related to the alteration in the activity state of the complex; the kinase activity was slightly lower in 60 wk old rats than in the younger rats under the fed condition and activation of the kinase by starvation was greater in the younger rats. The mechanism for the decrease in activity of pyruvate dehydrogenase complex was discussed on the basis of glucose and fatty acid utilization of heart muscle cells.

Aging↗

Corrosion behavior of 2205 duplex stainless steel.

The corrosion of 2205 duplex stainless steel was compared with that of AISI type 316L stainless steel. The 2205 stainless steel is a potential orthodontic bracket material with low nickel content (4 to 6 wt%), whereas the 316L stainless steel (nickel content: 10 to 14 wt%) is a currently used bracket material. Both stainless steels were subjected to electrochemical and immersion (crevice) corrosion tests in 37 degrees C, 0.9 wt% sodium chloride solution. Electrochemical testing indicates that 2205 has a longer passivation range than 316L. The corrosion rate of 2205 was 0.416 MPY (milli-inch per year), whereas 316L exhibited 0.647 MPY. When 2205 was coupled to 316L with equal surface area ratio, the corrosion rate of 2205 reduced to 0.260 MPY, indicating that 316L stainless steel behaved like a sacrificial anode. When 316L is coupled with NiTi, TMA, or stainless steel arch wire and was subjected to the immersion corrosion test, it was found that 316L suffered from crevice corrosion. On the other hand, 2205 stainless steel did not show any localized crevice corrosion, although the surface of 2205 was covered with corrosion products, formed when coupled to NiTi and stainless steel wires. This study indicates that considering corrosion resistance, 2205 duplex stainless steel is an improved alternative to 316L for orthodontic bracket fabrication when used in conjunction with titanium, its alloys, or stainless steel arch wires.

Chromium↗

Regional difference in lipolysis caused by a beta-adrenergic agonist as determined by the microdialysis technique.

We have investigated the difference in lipolysis caused by a beta-adrenergic agent between visceral and abdominal subcutaneous adipose tissues in vivo. Glycerol levels (lipolysis index) were continuously monitored in mesenteric and abdominal subcutaneous adipose tissues of anaesthetized Wistar rats using the microdialysis technique. During microdialysis, increasing concentrations of the lipolytic agent, isoproterenol (10(-8), 10(-7), 10(-6), 10(-5) mol L-1), were added to the perfusion. Glycerol concentrations in dialysate at each isoproterenol concentration, blood glucose concentrations during the experiment, and plasma insulin concentrations before and immediately after the experiment were measured. The effect of isoproterenol on local blood flow was investigated using the ethanol technique. The clearance rate of ethanol from the perfusion medium was used as the index of local blood flow. There was no significant change in blood glucose or plasma insulin concentrations during the study. Glycerol levels in dialysate were significantly higher in mesenteric than in abdominal subcutaneous adipose tissues at all isoproterenol concentrations. The percentage change of baseline ethanol ratio was not altered by increasing isoproterenol concentrations in both mesenteric and subcutaneous adipose tissues. There was also no significant difference in percentage change of the baseline ethanol ratio between mesenteric and abdominal subcutaneous adipose tissues. These results suggest that mesenteric adipose tissue is characterized by an even higher beta-adrenergic agonist-induced lipolysis than abdominal subcutaneous adipose tissue.

Abdomen↗

Titanium-porcelain system. Part II: Bond strength of fired porcelain on nitrided pure titanium.

Commercially pure titanium (CPT) substrate was subjected to porcelain firing and bond strengths under three-point bending mode (span length: 15 mm; crosshead speed: 0.5 mm/min) were evaluated. Experimental variables included surface treatments of CPT and porcelain firing schedules. Variables for the surface treatments were (1) sandblasting, (2) mono- and triple-layered nitridation, and (3) mono-layered chrome-doped nitridation. Variables for the porcelain firing schedule included (4) bonding agent application, (5) bonding agent plus gold bonding agent application, and (6) Procera porcelain application. All together eleven sample groups were prepared with different combination of aforementioned experimental variables. Statistically all of them exhibited no significant differences. Hence, we employed two further criteria; (I) the minimum bond strength should exceed the maximum porcelain strength per se, and (II) the CPT substrate should not be heated close to the beta-transus temperature. After applying these criteria, it was concluded that mono-layered nitridation and mono-layered application of chrome-doped nitridation on both (with and without) sandblasted and non-sandblasted surfaces were the most promising conditions for a successful Titanium-Porcelain System.

Dental Porcelain↗

On the three-point flexural tests of dental polymeric resins.

Currently acrylic resins are commonly employed in many medical applications, especially for the fabrication of long span provisional restorations in dentistry and bone cement in orthopedics. On of the major problems associated with the conventional type of acrylic resins is their unsatisfactory mechanical properties. Among many attempts to strengthen acrylic resins, it has been demonstrated that they can be strengthened through the addition of reinforcement(s) as structural components of different size, shape and chemical composition, dispersed in the acrylic matrix, thus forming a composite structure. In the course of studies to strengthen dental polymeric resins by admixing various metallic oxide particles, PMMA-, PEMA-, and PIMA-based resins were reinforced by 2 vol.% added alumina, magnesia, zirconia, and silica powders. It was found that PMMA admixed with 2 vol.% zirconia exhibited the best improvement of mechanical properties (breaking strength, modulus of elasticity, offset yield strength, and fracture toughness as well). All tests were conducted under three-point bending. It was also found that the breaking strength based on the original sample dimension was, at most 20% less than those based on the final sample dimension. Moreover, this discrepancy was independent of the type of tested material, but dependent on the sample's modulus of elasticity.

Analysis of Variance↗

Bulge ductility of several occlusal contact measuring paper-based and plastic-based sheets.

Articulating paper/film is a sheet strip that is coated with ink- or dye-containing wax and is used for marking occlusal contacts and monitoring the results. New types of occlusal film systems have been developed recently, which are capable of being computer-interfaced to identify the occlusal contact points and digitize the occlusal force. The mechanical ductility and thickness of these occlusal sheets constitute some of their important properties. The objective of this study was to evaluate seven different occlusal sheets and compare their bulge ductility and thickness. A custom-designed photo-sensing bulge tester was used. Three paper-based sheets (BAP, BET and SFA), two plastic-based sheets (ACF and AOS), and advanced systems (TSS and FDP) were tested. The specimen size was 20 mm square. Fifteen samples were tested for each material. The sheet film thickness with coated layers was as follows: BAP, 62 microns; BET, 46 microns; SFA, 133 microns; ACF, 23 microns; AOS, 14 microns; TSS, 134 microns; and FDP, 82 microns. Ductility (standard deviation) was as follows: BAP, 2.10 (0.0060)%; BET, 2.14 (0.008)%; SFA, 5.19 (0.57)%; ACF, 8.68 (0.05)%; AOS, 16.26 (0.41)%; TSS, 16.26 (0.41)%; and FDP, 6.37 (0.09)%. One-way ANOVA analysis indicated that (1) there in no statistical difference between BAP and BET (p > 0.001), (2) there is a statistical difference (p < 0.001) among all the rest of the tested occlusal sheets, and (3) bulge ductility appears to be linearly related to film thickness, its correlation depending upon types of base materials.

Coloring Agents↗

Reinforcement of acrylic resins for provisional fixed restorations. Part I: Mechanical properties.

Acrylic resins are commonly used in many dental applications; especially in the fabrication of provisional fixed partial dentures. Among noticed technical drawbacks associated with this material are unsatisfactory mechanical properties. Moreover, if acrylic resins are exposed to moist environment, water sorption results in further mechanical deterioration. In order to improve the mechanical properties, aluminum, magnesium, and zirconium oxide powders and pulverized E-glass particles were separately admixed with pre-polymerized acrylic resin beads prior to mixing with monomer liquid. Particle loading ratios were 1, 2 and 3 vol.% with respect to pre-polymerized beads. Poly(methyl methacrylate), poly(ethyl methacrylate) and poly(isobutyl methacrylate) were used as resin matrices. Furthermore, a metal primer agent was employed in order to form a strong interphase between admixed particles and polymer matrix phase. Samples were subjected to three-point transverse bending tests at a crosshead speed of 10 mm/min. It was concluded that (1) addition of particles generally increases the water sorbed by the composite resins systems, (2) however, two vol.% admixtures in a PMMA resin matrix showed significant improvements in the mechanical properties (p < 0.05), (3) among the oxide particles, zirconia exhibited the greatest improvements in modulus of elasticity, transverse strength, toughness and hardness, and (4) mechanical properties (transverse strength, 0.2% offset yield strength and modulus of elasticity) were linearly correlated to hardness numbers.

Acrylic Resins↗

Reinforcement of acrylic resins for provisional fixed restorations. Part II: Changes in mechanical properties as a function of time and physical properties.

In Part I, it was found that (i) 2 vol.% admixture of reinforcing elements in PMMA (Jet) resin matrix had a significant beneficial effects on the mechanical properties, and (ii) among these, zirconia exhibited the greatest improvements in modulus of elasticity, transverse strength, toughness, and hardness number. Using the best combination (i.e., PMMA resin matrix and 2 vol.% ZrO2), exothermic temperature raise and polymerization shrinkage were further investigated. Deterioration in mechanical properties due to prolonged water sorption were also studied for 5 weeks. The following can be concluded: (1) By increasing liquid/powder ratio for PMMA control samples, the peak temperature occurrence was retarded by 3 min and raised by 8 degrees C. (2) The effect of admixed oxide particles to PMMA resin matrix or the heat generated during polymerization was not significant. (3) The polymerization volumetric shrinkage was influenced by the a mixture of particles, with increases as large as 0.9% (or 0.3% in linear shrinkage). (4) PMMA resin admixed with 2 vol.% of zirconia particles showed a continuous weight gain due to water sorption, mechanical properties appears to be increasing up to 1-week sorption, followed by rapid drop of all properties. (5) Autopolymerizing acrylic resins are a resin-resin composite material of pre-polymerized beads embedded in a newly formed acrylic matrix. The main fracture modality appears to occur through the matrix and at the interface, although some trans-beads fractures were identified. (6) It was suggested that incorporating certain type of oxide particles into the pre-polymerized beads would provide stronger resin matrix.

Acrylic Resins↗

Effect of selected physical properties of waxes on investments and casting shrinkage.

This study evaluated the relationship between flow characteristics, bending strength, and softening temperature of paraffin and dental inlay waxes to casting shrinkage when patterns were invested with a phosphate-bonded investment. This study found that the casting shrinkage decreased as the flow of the wax pattern increased. If a low flow wax is used or if there is a need for a thick pattern, the size of the casting ring should be increased. When wax patterns are formed for cast restorations, it is important to select the type of wax with the most desirable properties for the margin and the occlusal portions. Moreover, to accurately fabricate castings, it is necessary to understand the physical properties of the chosen waxes.

Chemical Phenomena↗

Effect of light exposure on fracture toughness and flexural strength of light-cured composites.

OBJECTIVES: This study was conducted to investigate the curing characteristics of light-cured composites and their related mechanical properties. METHODS: Single-edge notch specimens [25 mm x 2.5 mm x 5 mm with a 5 mm notch (a/W = 0.5)] were prepared for fracture toughness measurements. For flexural strength testing, a stainless steel mold (25 mm x 2 mm x 2 mm) was used. Light-cured composites were condensed into the mold, and the middle third of the specimen was first activated for 30 s with 400 mW/cm2, for 60 s with 200 mW/cm2, or for 120 s with 100 mW/cm2. Then the remaining thirds were activated at the same intensity and curing time as the middle third. After 24 h storage in 37 degrees C water, three-point bending tests were performed with a span length of 20 mm at a crosshead speed of 0.5 mm/min. A one-way ANOVA, followed by a Newman-Keuls test (p < 0.05), were used to compare the data obtained from each group to test the effect of the curing conditions. RESULTS: Fracture toughness, flexural strength, and flexural modulus varied with resin composites. Among the three curing conditions for each material, there were no significant differences in fracture toughness, flexural strength, or flexural modulus. SIGNIFICANCE: The fracture toughness and the flexural strength were the same when irradiations with the same amount of energy (light intensity multiplied by curing time) were used. It was found that, at lower light intensity, longer curing was required to provide comparable mechanical properties. An accumulated irradiation energy obtained through a product of the light intensity and curing time may serve as a guideline to produce samples exhibiting equivalent fracture toughness as well as flexural strengths.

Analysis of Variance↗

Effect of C-peptide administration on whole body glucose utilization in STZ-induced diabetic rats.

Recent studies suggest that C-peptide stimulates glucose transport in isolated skeletal muscle. In order to determine the effect of C-peptide on whole body glucose utilization, streptozotocin (60 mg kg-1) (STZ)-induced diabetic and normal rats were studied using the euglycaemic clamp procedure and continuous infusion of somatostatin (1.0 micrograms kg-1 min-1) in pentobarbital-anaesthetized rats. Plasma insulin levels during the 6.0- and 30.0-mU kg-1 min-1 insulin infusions rose to 70-90 microU mL-1 and 500-700 microU mL-1, respectively. Blood glucose concentrations were clamped at 7.5-7.9 mmol L-1 in the diabetic rats and at basal levels or 7.7 mmol L-1 in the non-diabetic (normal) rats. Biosynthetic human C-peptide (0.5 nmol kg-1 min-1) was infused in 12 diabetic and 11 normal rats, resulting in concentrations of 26-41 nmol L-1. The metabolic clearance rate of glucose (MCR) for the diabetic rats receiving C-peptide (12.0 +/- 1.0 mL kg-1 min-1) was significantly (P < 0.01) higher than that in the diabetic rats given saline (6.3 +/- 0.7 mL kg-1 min-1) or a randomly scrambled C-peptide (7.8 +/- 1.3 mL kg-1 min-1) at low-dose insulin infusion but not at the high-dose insulin infusion. In normal rats C-peptide did not significantly increase the MCR for glucose. These results thus demonstrate that C-peptide has the capacity to increase glucose utilization in STZ-induced diabetic rats.

Animals↗

Exercise training prevents maturation-induced decrease in insulin sensitivity.

We examined the effects of exercise training initiated before maturation or after maturation on insulin sensitivity and glucose transporter GLUT-4 content in membrane fractions of skeletal muscle. Female Wistar rats (4 wk of age) were divided into sedentary and exercise-trained groups. At 12 wk of age, a subset of the trained animals (Tr) was killed along with a subset of sedentary controls (Sed). One-half of the remaining sedentary animals remained sedentary (Sed-Sed) while the other half began exercise training (Sed-Tr). The remaining rats in the original trained group continued to train (Tr-Tr). Euglycemic clamp (insulin infusion rate at 6 mU.kg body wt-1. min-1) was performed at 4, 12, and 27 wk. After euglycemic clamp in all animals except the 4-wk-old, hindlimb (gastrocnemius and part of quadriceps) muscles were removed for preparation of membrane fractions. In sedentary rats, glucose infusion rate (GIR) during euglycemic clamp was decreased from 15.9 mg.kg-1.min-1 at 4 wk of age to 9.8 mg.kg-1.min-1 at 12 wk of age and 9.1 mg.kg-1.min-1 at 27 wk of age. In exercise-trained rats, the GIR was not significantly decreased by maturation (at 12 wk) and further aging (at 27 wk). Initiation of exercise after maturation restored the GIR at 27 wk of age to the same levels as these for the corresponding exercise-trained rats. GLUT-4 content in plasma and intracellular membrane fractions of hindlimb muscle obtained just after euglycemic clamp showed the same trend as the results of GIR. These results suggest that exercise training prevented the maturation-induced decrease in insulin sensitivity. Improvement of insulin sensitivity caused by exercise training was attributed, at least in part, to the increase in insulin-sensitive GLUT-4 on the plasma membrane in skeletal muscle.

Age Factors↗

Trial production of titanium orthodontic brackets fabricated by metal injection molding (MIM) with sintering.

Safety and esthetics are two indispensable factors to consider when fabricating orthodontic brackets. However, these factors are not easily achieved when conventional techniques (including forging and casting) are used in the mass production of titanium brackets, albeit the brackets exhibit excellent biocompatibility. In the present study, orthodontic brackets were manufactured by metal powder injection molding with sintering. Brackets with three different base designs were made and subjected to compression shear tests for evaluation of their bonding strength to enamel substrate. The shapes given to the dimple of the base were spherical, oval, and grooved. The maximum shear forces for each type were 11.1 kgf, 7.6 kgf, and 18.5 kgf, respectively. The bonding strengths of the titanium bracket were equivalent to those obtained with conventional stainless steel brackets. Moreover, uniform distribution of Vickers hardness values (average, 240 +/- 40 Hv) measured at three locations indicated that the titanium bracket was uniformly sintered. Accordingly, titanium brackets thus fabricated exhibit a potential for clinical application.

Analysis of Variance↗

Dentin bonding system. Part I: Literature review.

Currently, clinicians face choices of restoration including amalgams (mercury-based, gallium-based alloys, or mercury-free silver-based substitutes), composite resins, ceramics, and gold alloy. In order to choose an appropriate restorative material, many parameters are involved; they include preparation time requirements, finishing and polishing, marginal integrity, anatomy and contours, chipping and fracture, sensitivity, microleakage, wear resistance, and corrosion resistance. It is generally believed that amalgams are still evaluated as the best of all restorative materials as far as the aforementioned parameters are concerned. It is claimed that the amalgams exhibit in the range of 10 to 25 service years, while the composite resin exhibits ranging between 7 and 11 service years. When a composite resin requires a mass large enough for indirect fabrication, a bonding system is demanded with which this restoration should form an instantaneous, impervious, and stable bond to the tooth structure. Roughly a quarter century has passed since the research and development of a promising dentin bonding system was initiated. We are now in the fifth generation of the dentin bonding system, during the research and development of which various types of bonding agents as well as bonding models have been introduced. In this article, the history of development of the bonding agents and the understanding of the bonding mechanism will be reviewed.

Composite Resins↗