Search PubMed⌕ Search

Biomedical subjects

Y Badonnel

Publications and source records attributed to Y Badonnel.

At least 19 recordsLinked to original sources

Comparison of progesterone concentration determination by 12 non-isotopic immunoassays and gas chromatography/mass spectrometry in 99 human serum samples.

A single serum progesterone determination may be highly predictive for early pregnancy and in vitro fertilisation and embryo-transfer outcomes. We therefore compared 12 direct non-isotopic progesterone immunoassays with gas-chromatography/mass spectrometry (GC/MS). For each assay, data from the analysis of 99 individual sera were compared with data obtained by GC/MS, using regression and bias plot analyses and the ratio method. We observed a larger difference in concentration between high and low values and a broader distribution of results for immunoassays than for GC/MS. All immunoassays displayed bias in the calibration process and a lack of specificity and/or sensitivity, to various degrees. We tried to identify the parameters of the assay procedure that might contribute to these discrepancies. None of the criteria investigated (antibodies, control and preparation of calibrators, blocking agents and choice of tracer) had a significant effect when studied alone.

Chemistry, Clinical↗

Severe side effects and drug plasma concentrations in preterm infants treated with doxapram.

A high-performance liquid chromatography method has been developed for simultaneous determination of doxapram and its metabolites including ketodoxapram, the main and only active metabolite. The aim of the study was to evaluate this microtechnique and to report the cases involving severe adverse effects to determine toxic plasma levels in neonates. The method was found to be selective, and showed a good baseline separation of doxapram and metabolites. Recovery, linearity, intraday/interday precision, and limit of detection determined in aqueous solutions and in spiked plasma were satisfactory. The assay is simple, rapid, and plasma-sparing, which represents a true advantage in managing neonates. Case analysis was performed in two consecutive periods: 124 preterm infants in the first period and 173 in the second period. Severe toxic effects were observed in 4 cases in the first period, with doxapram plus keto-doxapram levels 9 mg/L. In the second period, only one case was observed. High-range plasma concentrations were significantly less frequent in the second period than in the first one. The authors conclude that measuring doxapram plus keto-doxapram in plasma may be of interest to avoid severe toxic effects in preterm neonates treated with doxapram.

Chromatography, High Pressure Liquid↗

Undetectable luteinizing hormone levels using a monoclonal immunometric assay.

Previous studies have shown wide discrepancies among the results obtained with different immunometric assays. We present five cases (out of 4000 women) whose plasma luteinizing hormone was not detected using a LH immunometric assay (LH Stratus Baxter) but was recognized by other kits. These cases concerned one 28-year-old woman presenting with infertility and four postmenopausal women. The LH Amerlite kit gave detectable but low results. The results obtained with the other kits were > 7 IU/l. FSH levels were > 7 IU/l. In one case, sera were taken before and after the menopause; differences between the LH results increased. Discrepancies among LH assay kits have been attributed to variation both in standard curve calibration and in epitope specificity of the kit monoclonal antibodies. The Baxter kit might misrecognize some isoforms present in postmenopausal women. The present data illustrate the potential false results with such immunoassays in routine clinical laboratory testing. When undetectable LH results are not clinically explained or when disparities between LH and FSH are observed, we suggest using a second methodology or a bioassay if necessary. Improvement in LH assays and standardization might resolve the problem of discrepancies between the LH results.

Adult↗

[Value of immunoassay of hCG for the determination of high plasma concentrations].

The serum concentration of human chorionic gonadotrophin is higher in trisomy 21 than in normal pregnancy. Our study aimed at comparing 17 commercial kits, both those for measuring high concentrations and others for diagnosis and initial follow-up of pregnancy under specific conditions, ie for measuring hCG concentrations between weeks 14 and 18 of pregnancy. All kits were satisfactory; however, usual values for the gestational weeks concerned need to be established for each reagent.

Chorionic Gonadotropin↗

[Comparative study of ofloxacin+amoxicillin-clavulanic acid versus doxycycline+amoxicillin-clavulanic acid combination in the treatment of pelvic Chlamydia trachomatis infections].

OBJECTIVE: To evaluate the efficacy and safety of ofloxacin+coamoxiclav versus doxycycline-coamoxiclav in the treatment of chlamydial pelvic infections. DESIGN: An open, comparative, randomised, monocentric study. SUBJECTS: A hundred and eighteen patients (85 endometritis and 33 salpingitis) were included. Clinical, laparoscopic and bacteriological assessments were performed before treatment. 30.4% of salpingitis were considered as severe (COGIT score > 6). 25.4% of acute pelvic infections were only caused by Chlamydia trachomatis. TREATMENT: A hundred and eighteen patients were treated orally with 3 week combination ofloxacin (200 mg b.i.d.) + coamoxiclav (1 g b.i.d.) (n = 60) or with a 6 week coamoxiclav (1 g b.i.d.) + doxycycline (100 mg b.i.d.) (n = 58). RESULTS: Oral combination ofloxacin-coamoxiclav is as effective as oral combination doxycycline+coamoxyclav with respectively 96.7% versus 96.6% and 100% versus 98.4% satisfactory clinical et bacteriological results.

Adolescent↗

[Validity of immunochemical assays for blood estradiol. Study conducted in 1994].

Since 1989 many kits have been commercialized for measuring estradiol by non-isotopic immunoassays which largely contributed to the diffusion of this parameter. Rapidly, in quality control schemes, a wide dispersion of results has been observed. In this paper, the kits' characteristics (precision, accuracy and detection limit) have been studied and compared to a reference method (gas chromatography-mass spectrometry). In addition, estradiol determinations in patients with various pathophysiological situations have been performed to underline the difficulties of interpretation of this analyte when clinicians compare results given by the different kits. This work demonstrates that precision and accuracy varied both with the kit and the level of concentration of estradiol and gives better results for high concentrations of estradiol. In seven out of the 12 kits, the limits of detection are in good agreement with those announced by manufacturers. On the contrary, the determination on patients sera gives results with a high variability with no systematic error.

Adolescent↗

Inhibin as a marker for hydatidiform mole: a comparative study with the determinations of intact human chorionic gonadotrophin and its free beta-subunit.

OBJECTIVE: The purpose of the study was to evaluate plasma inhibin as a marker of hydatidiform mole and to compare the results with intact human chorionic gonadotrophin (hCG) and its free beta-subunit. DESIGN: Serial determinations of the plasma concentrations of inhibin, intact human chorionic gonadotrophin and its free beta-subunit in cases of hydatidiform mole over an average period of 140 days. PATIENTS: Five cases of hydatidiform mole, including patients with spontaneous remission after evacuation or persistent trophoblastic disease. MEASUREMENTS: Immunoreactive inhibin, hCG and free hCG beta-subunit were measured using standard enzyme immunoassays. RESULTS: Inhibin and free hCG beta-subunit levels were greater than in normal pregnant women at the same gestational age. Only intact hCG could detect the persistence of trophoblastic tissue. CONCLUSIONS: Our data suggest that inhibin, intact human chorionic gonadotrophin and free beta-subunit might be useful as diagnostic markers of molar pregnancies. However, the original method of intact hCG determination is still superior for follow-up.

Adult↗

Early detection of antibodies to human immunodeficiency virus 1 by a third-generation enzyme immunoassay. A comparative study with the results of second-generation immunoassays and western blot.

The aim of the study was to examine the sensitivity and the specificity of a HIV-1/HIV-2 third-generation enzyme immunoassay, the Abbott recombinant HIV-1/HIV-2 third-generation enzyme immunoassay, which is reported to detect simultaneously IgG and IgM. Sensitivity was evaluated with sera from seropositive subjects and a series of samples from eight HIV-1 seroconverting subjects. Results were compared with Western blot, second-generation immunoassays (including Vidas HIV-1 + 2) and an HIV-1 antigen assay. Specificity was studied with sera collected from a low-risk population and sera with false-reactive enzyme immunoassays results. In seven cases, the third-generation immunoassay detected HIV-antibodies several days earlier (range 4 to > or = 9 days) than the Western blot test according to the criteria proposed by the Association of State and Territorial Public Health Laboratory Directors, ie, positive with two of the three bands-gp160 or gp120, gp41, and p24. In the last case detection occurred at the same time as Western blot. The second-generation tests generally detected HIV-antibodies at the same time as Western blot. Antigaenemia was positive in the first samples tested in most cases, prior to or simultaneously with the Abbott third-generation test first reactivity, before the second generation tests and the Western blot test. In most cases, the disappearance of detectable HIV antigen was observed, and was concurrent with the development of the antibodies immune response. For our low-risk population, the current third-generation EIA test obtained a false-reactive rate of 0.26%. Our data indicate that the Abbott third-generation immunoassay is more sensitive than the Western blot test and the second-generation tests. The addition of a third-generation assay to the strategy for HIV-antibody screening may indeed be of interest and could make it possible to decrease the number of false-negative results.

Blotting, Western↗

[Immunoassay and measurement of the biological activity of serum hLH: results obtained of a multicenter study].

The discrepancy between results obtained using different anti-hLH antibodies available on the market led us (in the context of a contract with the CNAMTS) to compare the results of hLH immunoassays (eight different reagents) with those of hLH bioassays based on the measurement of the steroidal activity of this hormone on mouse, rat or pig testicular preparations (five methodologies). Twenty-nine samples of serum or human serum pools were tested. The values resulting from these tests reveal differences linked to the nature of the antibodies or to the methodological conditions used for the testicular preparations. Some antibodies seem unable to identify some hLH forms which, however, can be detected by biological methods.

Adult↗

[Immunological assay of chorionic gonadotropin during pregnancy. Multicenter study of 5 reagents].

Five commercial kits for the quantitative determination of human chorionic gonadotropin (hCG) used for detection and monitoring of pregnancy were evaluated. Five kits used two-sites "sandwich" enzymoimmunoassay and monoclonal antibodies. Precision, standardization and sensitivity were tested and practicability was assessed. Good results are obtained for four kits (Beckman had poor results), sensitivity and specificity are good. Practicability of five kits was evaluated but choose was in relation to configuration of laboratory.

Chorionic Gonadotropin↗

[Citrullinemia].

Explore the source record for details and available documents.

Alanine↗