Search PubMed⌕ Search

Biomedical subjects

W J Manning

Publications and source records attributed to W J Manning.

At least 73 records · Page 4Linked to original sources

Inhibition of flowering and reproductive success in spreading dogbane (Apocynum androsaemifolium) by exposure to ambient ozone.

Ground-level ozone continues to be a cause for concern in terrestrial ecosystems in the northeastern United States and Canada. Spreading dogbane (Apocynum androsaemifolium L.) is one of many indigenous herbaceous plant species exhibiting foliar injury that are commonly monitored in ecosystem assessment programs. Details about possible effects of ambient ozone on reproductive components of these species are lacking. For 103 days, from 31 May to 10 September, A. androsaemifolium plants were grown in open-top chambers in either carbon-filtered air (CF), non-filtered air (NF) (approximately 1xambient), or chamberless ambient air plots (AA). Aspects of sexual reproduction were measured to determine whether impairment occurs in polluted air. Additionally, the ozone protectant chemical ethylenediurea (EDU) was applied to foliage to determine its effect on foliar injury. By the end of the experiment visible foliar injury was absent in CF air and nominal in the NF and AA treatments. Plants grown in CF-chamber air produced significantly more flowers and fruits than those grown in either NF-chamber air or AA plots. Flowers produced by plants grown in CF air also survived to mature fruits at a rate 1.7x greater than plants in NF air and 1.5x greater than plants in AA plots. We were unable to conclude whether EDU protected plants from foliar ozone injury due to the general lack of foliar injury in ozone-exposed plants. The results demonstrate that foliar injury is not necessarily required to elicit negative effects on sexual reproduction in A. androsaemifolium. Implications for the population biology of A. androsaemifolium related to adverse effects of chronic ozone exposure on sexual reproduction are discussed.

Journal Article↗

Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography.

OBJECTIVES: The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND: For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning the 3D volume along the major axis of the coronary vessels may help to overcome such limitations. METHODS: Fifteen healthy adult volunteers and seven patients with X-ray angiographically confirmed coronary artery disease underwent free-breathing navigator-gated and corrected 3D coronary MRA. For an accurate volume targeting of the high resolution scans, a three-point planscan software tool was applied. RESULTS: The average length of contiguously visualized left main and left anterior descending coronary artery was 81.8 +/- 13.9 mm in the healthy volunteers and 76.2 +/- 16.5 mm in the patients (p = NS). For the right coronary artery, a total length of 111.7 +/- 27.7 mm was found in the healthy volunteers and 79.3 +/- 4.6 mm in the patients (p = NS). Comparing coronary MRA and X-ray angiography, a good agreement of anatomy and pathology was found in the patients. CONCLUSIONS: Double-oblique submillimeter free-breathing coronary MRA allows depiction of extensive parts of the native coronary arteries. The results obtained in patients suggest that the method has the potential to be applied in broader prospective multicenter studies where coronary MRA is compared with X-ray angiography.

Adult↗

Impact of on-line endocardial border detection on determination of left ventricular volume and ejection fraction by transthoracic 3-dimensional echocardiography.

This study was performed to determine whether use of on-line automated border detection (ABD) could reduce data analysis time for 3-dimensional echocardiography (3DE) while maintaining accuracy of 3DE in measures of left ventricular (LV) volumes and ejection fraction (EF). The study proceeded in 2 phases. In the validation phase, 20 subjects were examined with the use of 3DE and of monoplane 2-dimensional (2D) ABD. Results were compared with the reference standard of magnetic resonance imaging (MRI). In the test phase, 20 subjects underwent two 3DE studies (once with images optimized for visual border definition and once with images optimized for ABD border tracking) and a conventionally used 2D ABD study. For 3DE, volumes and EF were determined with the use of manually traced borders and ABD. Analysis times were recorded with a digital stopwatch. In the validation phase, 3DE and MRI results correlated very well (r = 0.99) without systematic differences. Comparison of 2D ABD with MRI showed good correlation for LV volumes (r >/= 0.90) and EF (r = 0.85) despite significant underestimation. For the test phase, Acoustic Quantification-optimized 3-dimensional datasets underestimated end-diastolic volume and EF relative to visually optimized 3-dimensional datasets regardless of whether borders were hand-traced or ABD was used. However, correlations ranged from r = 0.96 to r = 0.98 for LV volumes and 0.88 to 0.91 for LV EF and were superior to those for 2D ABD. Data analysis times decreased moderately with the use of ABD, but scan times increased; total study times were unchanged. Use of on-line ABD with 3DE reduces data analysis time and is more accurate than conventional monoplane 2D ABD but results in underestimation of LV volumes and EF. Additional automated postprocessing techniques may be required to obtain accurate measures, consistently using 3DE in conjunction with on-line ABD.

Adult↗

Cardioversion in patients with atrial fibrillation and left atrial thrombi on initial transesophageal echocardiography: should transesophageal echocardiography be repeated before elective cardioversion? A cost-effectiveness analysis.

BACKGROUND: Transesophageal echocardiography (TEE) is used to expedite early cardioversion for patients with atrial fibrillation in whom TEE excludes the presence of atrial thrombi. However, the management of patients with atrial thrombi on initial TEE is controversial. Some advocate cardioversion after 3 to 4 weeks of anticoagulant therapy, whereas others perform a follow-up TEE to document thrombus resolution. We performed a cost-effectiveness analysis to compare the two strategies. METHODS AND RESULTS: A computer-based decision analysis model was used to compared 2 strategies: No Follow-up TEE-patients with thrombi on initial TEE complete 4 weeks of anticoagulation and undergo elective cardioversion. Follow-up TEE-patients undergo a follow-up TEE after 4 weeks of anticoagulant therapy. If a thrombus is detected, cardioversion is not performed and patients remain in atrial fibrillation; patients without a thrombus undergo cardioversion. Under our baseline estimates, the Follow-up TEE strategy is less costly and slightly more effective than the No Follow-up TEE strategy. The results are most sensitive to changes in the risk of postcardioversion stroke for patients with atrial thrombi on initial TEE who have completed 4 weeks of anticoagulation and to the probability of residual thrombi on follow-up TEE. CONCLUSIONS: In this cost-effectiveness analysis for patients with atrial fibrillation and left atrial thrombi detected on initial TEE, a Follow-up TEE strategy may be more cost-effective than the No Follow-up TEE strategy. However, the decision is particularly dependent on the risk of postcardioversion stroke in patients with undetected residual left atrial thrombi.

Anticoagulants↗

Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation.

OBJECTIVE: To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained atrial fibrillation, a duration similar to that experienced by patients undergoing warfarin anticoagulation before elective cardioversion. METHODS: To test the hypothesis that left atrial and left atrial appendage enlargement develop as a result of short term atrial fibrillation, serial anatomical and functional indices were measured using transoesophageal echocardiography (TOE) in 20 patients with recent onset atrial fibrillation (14 men, six women; mean (SEM) age 67 (2) years). Serial TOE was performed 2.5 months apart in patients with sustained atrial fibrillation. RESULTS: There was no significant change in left atrial area (23.7 cm(2) to 24.1 cm(2), p = 0.98); length (5.7 cm to 5.7 cm, p = 0.48); width (5.2 cm to 5.2 cm, p = 0. 65); volume (83 cm(3) to 87 cm(3), p = 0.51) or left atrial appendage area (7.9 cm(2) to 8.1 cm(2), p = 0.89); length (4.6 cm to 4.5 cm, p = 0.8); or width (2.5 to 2.4 cm, p = 0.87). Peak left atrial appendage velocity ejection (0.2 m/s to 0.2 m/s, p = 0.57), and presence of severe spontaneous echo contrast in the left atrial appendage (n = 15 (75%) to n = 13 (72%)) were also not significantly different. There was no correlation between changes in left atrial or left atrial appendage dimensions. CONCLUSIONS: In the setting of sustained atrial fibrillation, significant left atrial and left atrial appendage functional and anatomical remodelling do not occur with atrial fibrillation of a duration similar to that used for conservative anticoagulation in preparation for cardioversion.

Adult↗

Submillimeter three-dimensional coronary MR angiography with real-time navigator correction: comparison of navigator locations.

Three-dimensional free-breathing coronary magnetic resonance angiography was performed in eight healthy volunteers with use of real-time navigator technology. Images acquired with the navigator localized at the right hemidiaphragm and at the left ventricle were objectively compared. The diaphragmatic navigator was found to be superior for vessel delineation of middle to distal portions of the coronary arteries.

Adult↗

Relationship between motion of coronary arteries and diaphragm during free breathing: lessons from real-time MR imaging.

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.

Adult↗

Accelerated cardiac imaging using the SMASH technique.

SMASH (SiMultaneous Acquisition of Spatial Harmonics) was recently introduced as a novel rapid-imaging technique. The SMASH technique uses a partially parallel acquisition strategy, using spatial information from a radiofrequency coil array to accelerate imaging. This study constitutes the first application of SMASH to cardiac magnetic resonance imaging. The increased imaging speed provided by SMASH was used to obtain images with reduced breathhold duration, enhanced spatial resolution, and increased temporal resolution in healthy volunteers. The results obtained demonstrate the feasibility and potential clinical utility of cardiac magnetic resonance imaging using the SMASH technique.

Feasibility Studies↗

Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology.

The acquisition duration of most three-dimensional (3D) coronary magnetic resonance angiography (MRA) techniques is considerably prolonged, thereby precluding breathholding as a mechanism to suppress respiratory motion artifacts. Splitting the acquired 3D volume into multiple subvolumes or slabs serves to shorten individual breathhold duration. Still, problems associated with misregistration due to inconsistent depths of expiration and diaphragmatic drift during sustained respiration remain to be resolved. We propose the combination of an ultrafast 3D coronary MRA imaging sequence with prospective real-time navigator technology, which allows correction of the measured volume position. 3D volume splitting using prospective real-time navigator technology, was successfully applied for 3D coronary MRA in five healthy individuals. An ultrafast 3D interleaved hybrid gradient-echoplanar imaging sequence, including T2Prep for contrast enhancement, was used with the navigator localized at the basal anterior wall of the left ventricle. A 9-cm-thick volume, with in-plane spatial resolution of 1.1 x 2.2 mm, was acquired during five breathholds of 15-sec duration each. Consistently, no evidence of misregistration was observed in the images. Extensive contiguous segments of the left anterior descending coronary artery (48 +/- 18 mm) and the right coronary artery (75 +/- 5 mm) could be visualized. This technique has the potential for screening for anomalous coronary arteries, making it well suited as part of a larger clinical MR examination. In addition, this technique may also be applied as a scout scan, which allows an accurate definition of imaging planes for subsequent high-resolution coronary MRA.

Adult↗

When the body and appendage of the left atrium disagree: "Focal" atrial fibrillation-implications for atrial thrombus formation and risk of thromboembolism.

A case is presented of a man who had 5 hours of atrial fibrillation followed by spontaneous conversion and maintained sinus rhythm that persisted as shown by surface electrocardiography. Transesophageal echocardiography performed 24 hours after electrocardiographic conversion documented an atrial fibrillation pattern within the left atrial appendage, with a normal sinus Doppler pattern in the body of the left atrium. This apparent regional discrepancy in atrial function may partially explain the increased risk for "late" thromboembolism among patients with atrial fibrillation who appear to be successfully converted with sustained sinus rhythm.

Aged↗

Relation between the number of image planes and the accuracy of three-dimensional echocardiography for measuring left ventricular volumes and ejection fraction.

The relation between accuracy of 3-dimensional echocardiography (3DE) in determining left ventricular end-diastolic volume, end-systolic volume, and ejection fraction (compared with magnetic resonance imaging) and the number of component planes used for 3DE ventricular reconstruction was evaluated in 41 adult subjects with normal (n = 24) and abnormal (n = 17) left ventricles. Accuracy and confidence of 3DE gradually increased with use of additional component planes, so that > or = 10 planes from both parasternal and apical windows provided 3DE reconstructions that accurately predict magnetic resonance imaging-measured left ventricular volumes and ejection fraction with confidence.

Adult↗

Role of echocardiography in patients undergoing elective cardioversion of atrial fibrillation.

Echocardiography has emerged as a fundamental tool in the evaluation of patients with atrial fibrillation (AF). Transthoracic echocardiography remains a primary tool for the evaluation and management of many patients presenting with their first episode of AF, but it is not adequate for exclusion of atrial thrombi. TEE offers excellent visualization of the atria and accurate identification or exclusion of thrombi. In concert with therapeutic anticoagulation, a TEE-guided approach to early cardioversion appears to have a safety profile similar to that of conventional therapy (1 month of precardioversion warfarin). The TEE-guided approach offers the advantages of simplified anticoagulation management and shorter duration of sustained AF, thereby allowing for a more rapid recovery of atrial mechanical function. Warfarin should be continued for 1 month after cardioversion to allow for more complete recovery of atrial function and for prophylaxis should the patient revert to AF. Cost-effectiveness models demonstrate that TEE-guided cardioversion represents a cost-effective strategy, but only if the transthoracic echocardiogram is omitted. For patients with a thrombus on the initial TEE, follow-up TEE (to document thrombus resolution) is recommended before cardioversion.

Anticoagulants↗

Likelihood of spontaneous conversion of atrial fibrillation to sinus rhythm.

OBJECTIVES: We sought to determine the likelihood and predictors of spontaneous conversion to sinus rhythm of recent-onset atrial fibrillation (symptoms <72 h). BACKGROUND: Although spontaneous conversion of recent-onset atrial fibrillation is common, the likelihood and clinical and echocardiographic predictors have not been fully defined. Such data would be important for management of patients in whom early cardioversion is desired: Cardioversion could be delayed in patients with a high likelihood of spontaneous conversion, and it could be expeditiously pursued if spontaneous conversion is unlikely. METHODS: We screened 1,822 consecutive adults admitted to the hospital with atrial fibrillation and prospectively identified 356 patients (45% male, mean age +/- SD 68 +/- 16 years) with atrial fibrillation of <72-h duration. The occurrence of spontaneous conversion to sinus rhythm and clinical and echocardiographic data were identified through retrospective chart review. RESULTS: Spontaneous conversion to sinus rhythm occurred in 68% of the study group (n = 242; 95% confidence interval [CI] 63% to 73%). Among patients with spontaneous conversion, the total duration of atrial fibrillation was <24 h in 159 (66%), 24 to 48 h in 42 (17%) and >48 h in 41 (17%) (p < 0.001). Logistic regression analysis of clinical data identified presentation <24 h from onset of symptoms as the only predictor of spontaneous conversion (odds ratio 1.8, 95% CI 1.4 to 2.4, p < 0.0001). Normal left ventricular systolic function was more common among patients with spontaneous conversion (p = 0.03), but it was not an independent predictor of conversion. Left atrial dimension was similar between groups. CONCLUSIONS: Spontaneous conversion to sinus rhythm occurs in almost 70% of patients presenting with atrial fibrillation of <72-h duration. Presentation with symptoms of <24-h duration is the best predictor of spontaneous conversion.

Aged↗

Cardiac performance early after cardioversion from atrial fibrillation.

BACKGROUND: The mechanism for early improvement in cardiac function after cardioversion from atrial fibrillation is unknown. METHODS: We measured ventricular volumes and load-independent contractility during atrial fibrillation and within 24 hours after cardioversion to sinus rhythm in 15 adult patients (10 men, 5 women; mean age 63+/-4 years, range 31 to 81 years). Duration of atrial fibrillation ranged from <1 day to 6 months. RESULTS: After cardioversion, left ventricular ejection fraction increased from 51%+/-4% to 61%+/-4% (P=.001, 95% confidence intervals for the difference, 7% to 15%), stroke volume increased from 57+/-4 mL to 76+/-6 mL (P < .001, 95% confidence intervals 8 to 32 mL), and mean cycle length increased from 0.77+/-.04 seconds in atrial fibrillation to 1.02+/-.04 seconds in sinus rhythm (P=.002, 95% confidence intervals, 0.1 to 0.4 seconds). Cardiac contractility, as expressed by the slope and the intercept of the relation between rate-corrected circumferential velocity of fiber shortening and end-systolic wall stress (Vcfc/ESWS) remained unaltered in 13 of 15 patients, suggesting that intrinsic inotropic state was unchanged immediately after return of normal sinus rhythm. Finally, a significant correlation was observed between improvement in stroke volume and peak A-wave velocity (r=0.79, P=.035). CONCLUSION: Both left ventricular stroke volume and ejection fraction increase immediately after cardioversion, whereas intrinsic cardiac contractility is largely unchanged. These data suggest that the mechanism of this increase is enhanced left ventricular diastolic filling due mostly to increased cycle length and return of left atrial mechanical function.

Adult↗

Coronary MR angiography.

Coronary MR angiography is a new noninvasive diagnostic method in rapid evolution. It has the potential to combine structural information with functional assessment of coronary blood flow. Advances in technology will undoubtedly lead to enhanced resolution, improved accuracy, and shorter scan times. It is certain that coronary MR angiography will be a prominent diagnostic clinical tool in the years to come.

Coronary Angiography↗

Role of routine transthoracic echocardiography in evaluation and management of stroke.

OBJECTIVE: To determine the value of routine transthoracic echocardiography in patients with cerebral ischemia without known cardiac disease. DESIGN: The literature from 1990 to 1995 was searched and relevant bibliographies from these papers reviewed. Articles reporting the prevalence and/or risk of stroke for myxoma, vegetation, mitral stenosis, left atrial thrombus, left ventricular thrombus or cardiomyopathy, patent foramen ovale, and atrial septal aneurysm were used. Prevalences and recurrent stroke risk were examined for adult patients less than and greater than 45 years. RESULTS: Both the prevalence of transthoracic echocardiographic findings and recurrent risk of stroke differ by age. The finding of a patent foramen ovale can be expected in nearly half of younger patients with stroke, whilst transthoracic echo can be expected to yield no relevant lesion in three quarters of patients > 45 years. Warfarin anticoagulation appears beneficial in patients with mitral stenosis, left atrial thrombus, left ventricular thrombus, and left ventricular dysfunction, but is of unproven benefit for patent foramen ovale, atrial septal aneurysm, or in the absence of a risk-associated abnormality. CONCLUSION: For most transthoracic echo findings in stroke, optimal management strategies have not been well defined. Future research is needed to evaluate the appropriate therapeutic approaches.

Adult↗