Search PubMed⌕ Search

Biomedical subjects

W J Manning

Publications and source records attributed to W J Manning.

At least 55 records · Page 3Linked to original sources

Physicians' recommendations to patients for use of antibiotic prophylaxis to prevent endocarditis.

CONTEXT: The American Heart Association recommendations for infectious endocarditis (IE) prophylaxis, published in June 1997, sought to improve patient and physician compliance by simplifying the dosing regimen and clarifying endocarditis risk. Adherence to these updated recommendations in patients with echocardiographic verification of their endocarditis risk profile is unknown. OBJECTIVE: To determine the recommended and actual use of IE prophylaxis as reported by patients undergoing echocardiography. DESIGN, SETTING, AND PARTICIPANTS: All patients who underwent outpatient transthoracic echocardiography at a university-based tertiary hospital in Boston, Mass, during December 1997 were contacted 6 to 9 months later to respond to a survey, completed by 218 (80%) eligible subjects. MAIN OUTCOME MEASURE: Patients' report of their physicians' instructions on actual use of IE prophylaxis in accordance with patient risk category, determined by echocardiographic data. RESULTS: One hundred eight patients (49.5%) had clinical or echocardiographic findings for which prophylaxis was indicated. Of these 108 patients, 71 (65.7%) reported that they were instructed to take IE prophylaxis. Sixteen high-risk patients (88. 9%) but only 55 moderate-risk patients (61.1%) reported that they were instructed to take prophylaxis. Among the 110 negligible-risk patients, 29 (26.4%) reported that they had been instructed to take IE prophylaxis. Overall, 100 patients (45.9%) reported that they received physician instructions to take IE prophylaxis. Of those who subsequently underwent a procedure for which IE prophylaxis was indicated (n=68), 9 (13.2%) elected not to follow their physician's advice to take prophylaxis. CONCLUSIONS: We found that although most patients reported receiving instructions for IE prophylaxis use consistent with American Heart Association guidelines, IE prophylaxis overuse among negligible-risk patients and underuse among moderate-risk patients was common. Continued physician and patient education may lead to improved adherence to the current American Heart Association recommendations. JAMA. 2000;284:68-71

Antibiotic Prophylaxis↗

Reduction of cardiac volume in left-breast treatment fields by respiratory maneuvers: a CT study.

PURPOSE: A previous study of healthy female volunteers suggested that deep inspiratory breath holding can reduce the cardiac volume in the treatment portals for left-breast cancer treatment. The reduction of irradiated cardiac volume may be important considering the reported late cardiac morbidity and mortality and the frequent coexistent use of potentially cardiotoxic chemotherapy in breast cancer patients. In the present study, we evaluated the heart volume in the fields and, thus, the true benefit of this respiratory maneuver in breast cancer patients undergoing CT simulation. MATERIALS AND METHODS: Fifteen patients (median age, 53) were studied. For each patient, CT scans were performed both when the patient breathed normally (quiet respiration) and when the patient held her breath after a deep inspiration. Tangential fields were planned using the same medial, lateral, superior, and inferior borders on skin for the normal breathing and the breath-holding configurations. The cardiac and left-lung volumes within the tangential fields were calculated for both breathing configurations. Multiple scan series were performed for the breath-holding configuration to provide a more accurate delineation of the cardiac tissue and to study the reproducibility of the patient's position between different cycles of deep inspiration. RESULTS: None of the patients had difficulty holding her breath for 20 s. The cardiac volume in the field was reduced (-86 +/- 24%; p < 0.001) when patients held their breath after a deep inspiration compared to when breathing normally. For 7 patients (47%), deep inspiration moved the heart completely out of the radiation fields. The expansion of the lung tissue due to deep inspiration also increased the absolute lung volume in the tangential fields (183 cm(3) vs 97 cm(3), p < 0.001). However, the fractional volume of the left lung in the field was essentially unchanged. For all but 1 patient, the maximum difference between the external body contours from different breath holding cycles was 5 mm and occurred at the lateral aspect of the breast. At the medial aspect, as indicated by the position of the midline marker, the variations were well within the currently accepted tolerance for patient positioning during tangential treatment. CONCLUSIONS: Deep-inspiration breath holding substantially reduces cardiac volume in the tangential fields for left-sided breast cancer treatment. The variation between patient positions at different cycles of breath holding was found to be reasonably small. Therefore, it appears feasible to reduce cardiac radiation by treating patients with intratreatment minifractions lasting 10-15 s while patients hold their breath.

Aged↗

Free-breathing 3D coronary MRA: the impact of "isotropic" image resolution.

During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.

Adult↗

Coronary MR angiography: current status.

Since first described in the early 1990's, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multicenter studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology.

Clinical Trials as Topic↗

Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two- and three-dimensional echocardiography and magnetic resonance imaging.

OBJECTIVES: This study sought to determine the concordance between biplane and volumetric echocardiography and magnetic resonance imaging (MRI) strategies and their impact on the classification of patients according to left ventricular (LV) ejection fraction (EF) (LVEF). BACKGROUND: Transthoracic echocardiography and MRI are noninvasive imaging modalities well suited for serial evaluation of LV volume and LVEF. Despite the accuracy and reproducibility of volumetric methods, quantitative biplane methods are commonly used, as they minimize both scanning and analysis times. METHODS: Thirty-five adult subjects, including 25 patients with dilated cardiomyopathies, were evaluated by biplane and volumetric (cardiac short-axis stack) cine MRI and by biplane and volumetric (three-dimensional) transthoracic echocardiography. Left ventricular volume, LVEF and LV function categories (LVEF > or =55%, >35% to <55% and < or =35%) were then determined. RESULTS: Biplane echocardiography underestimated LV volume with respect to the other three strategies (p < 0.01). There were no significant differences (p > 0.05) between any of the strategies for quantitative LVEF. Volumetric MRI and volumetric echocardiography differed by a single functional category for 2 patients (8%). Six to 11 patients (24% to 44%) differed when comparing biplane and volumetric methods. Ten patients (40%) changed their functional status when biplane MRI and biplane echocardiography were compared; this comparison also revealed the greatest mean absolute difference in estimates of EF for those subjects whose EF functional category had changed. CONCLUSIONS: Volumetric MRI and volumetric echocardiographic measures of LV volume and LVEF agree well and give similar results when used to stratify patients with dilated cardiomyopathy according to systolic function. Agreement is poor between biplane and volumetric methods and worse between biplane methods, which assigned 40% of patients to different categories according to LVEF. The choice of imaging method (volumetric or biplane) has a greater impact on the results than does the choice of imaging modality (echocardiography or MRI) when measuring LV volume and systolic function.

Adult↗

Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction.

BACKGROUND: Accurate, reproducible, noninvasive determination of left ventricular (LV) volumes and ejection fraction (EF) is important for clinical assessment, risk stratification, selection of therapy, and serial monitoring of patients with cardiovascular disease. Three-dimensional echocardiography (3DE) approaches have demonstrated significantly greater accuracy than current clinical 2DE, but the clinical utility of 3DE has been limited because of the need for substantial modifications to scanning technique (eg, all image acquisition from a single acoustic window) or cumbersome additional hardware. We describe a novel 3DE system without these limitations and its application to patients. METHODS AND RESULTS: Twenty-five patients were examined by 3DE, 2DE, and magnetic resonance imaging (MRI). The 3DE system used a magnetic scanhead tracking device, and volumes were computed with a novel deformable shell model. End-diastolic volumes and EF by MRI ranged from 96 to 375 mL and 18% to 73%, respectively. There was excellent correlation, without statistically significant differences, between MRI and 3DE for end-systolic volume (ESV) (r(2) = 0.99) and end-diastolic volume (EDV) (r(2) = 0.98), ventricular stroke volume (SV) (r(2) = 0.93), and EF (r(2) = 0.97), with standard error estimates less than 10 mL for volumes and 3% for EF. Conventional 2DE consistently underestimated volumes (EDV, P <.01; ESV, P <.01; SV, P <.05); correlations with MRI were r(2) = 0.91 for ESV, r(2) = 0.88 for EDV, r(2) = 0.62 for SV, and r(2) = 0.72 for EF. Standard error estimates ranged from 16 to 20 mL for ventricular volumes and 9% for EF. Interobserver variability was reduced 3-fold with use of 3DE. CONCLUSIONS: The novel 3DE system allows unrestricted selection and combination of acoustic windows in a single examination, improves accuracy of estimates of LV volumes and EF 3-fold compared with 2DE, and is practical for routine clinical assessment of LV size and function in patients with a wide range of cardiac pathology.

Adult↗

Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study.

A partially parallel image acquisition technique, simultaneous acquisition of spatial harmonics, or SMASH, was used to increase the spatial and/or temporal resolution in contrast material-enhanced three-dimensional magnetic resonance angiography of the abdominal aorta and renal arteries. In eight healthy subjects, the breath-hold duration was halved at constant spatial resolution, or the spatial resolution was doubled at fixed breath-hold duration, with a 30%-55% reduction in the signal-to-noise ratio but otherwise preserved or improved image quality.

Adult↗

Low-cost MR-compatible moving heart phantom.

For the development and evaluation of cardiac magnetic resonance (MR) imaging sequences and methodologies, the availability of a periodically moving phantom to model respiratory and cardiac motion would be of substantial benefit. Given the specific physical boundary conditions in an MR environment, the choice of materials and power source of such phantoms is heavily restricted. Sophisticated commercial solutions are available; however, they are often relatively costly and user-specific modifications may not easily be implemented. We therefore sought to construct a low-cost MR-compatible motion phantom that could be easily reproduced and had design flexibility. A commercially available K'NEX construction set (Hyper Space Training Tower, K'NEX Industries, Inc., Hatfield, PA) was used to construct a periodically moving phantom head. The phantom head performs a translation with a superimposed rotation, driven by a motor over a 2-m rigid rod. To synchronize the MR data acquisition with phantom motion (without introducing radiofrequency-related image artifacts), a fiberoptic control unit generates periodic trigger pulses synchronized to the phantom motion. Total material costs of the phantom are US$ < 200.00, and a total of 80 man-hours were required to design and construct the original phantom. With schematics of the present solution, the phantom reproduction may be achieved in approximately 15 man-hours. The presented MR-compatible periodically moving phantom can easily be reproduced, and user-specific modifications may be implemented. Such an approach allows a detailed investigation of motion-related phenomena in MR images.

Artifacts↗

Clinical role of coronary magnetic resonance angiography in the diagnosis of anomalous coronary arteries.

Though rare, anomalous coronary artery disease is a well-known cause of myocardial ischemia and sudden death among children and young adults. The projectional nature of conventional x-ray angiography often leads to difficulty in the definition of anomalous vessels. Studies have now documented the high accuracy of coronary magnetic resonance angiography (MRA) for the noninvasive detection and definition of anomalous coronary arteries among patients with suspected anomalous coronary arteries of congenital conditions associated with anomalous coronary arteries. With increasing clinical experience, coronary MRA will likely emerge as the gold standard for the diagnosis of this condition.

Coronary Disease↗

Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA.

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.

Adolescent↗

Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography.

For free-breathing, high-resolution, three-dimensional coronary magnetic resonance angiography (MRA), the use of intravascular contrast agents may be helpful for contrast enhancement between coronary blood and myocardium. In six patients, 0.1 mmol/kg of the intravascular contrast agent MS-325/AngioMARK was given intravenously followed by double-oblique, free-breathing, three-dimensional inversion-recovery coronary MRA with real-time navigator gating and motion correction. Contrast-enhanced, three-dimensional coronary MRA images were compared with images obtained with a T2 prepulse (T2Prep) without exogenous contrast. The contrast-enhanced images demonstrated a 69% improvement in the contrast-to-noise ratio (6.6 +/- 1.1 vs. 11.1 +/- 2.5; P < 0.01) compared with the T2Prep approach. By using the intravascular agent, extensive portions (> 80 mm) of the native left and right coronary system could be displayed consistently with sub-millimeter in-plane resolution. The intravascular contrast agent, MS-325/AngioMARK, leads to a considerable enhancement of the blood/muscle contrast for coronary MRA compared with T2Prep techniques. The clinical value of the agent remains to be defined in a larger patient series. J. Magn. Reson. Imaging 1999;10:790-799.

Contrast Media↗

A fast 3D approach for coronary MRA.

Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.

Adult↗

Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging.

A general theory of signal-to-noise ratio (SNR) in simultaneous acquisition of spatial harmonics (SMASH) imaging is presented, and the predictions of the theory are verified in imaging experiments and in numerical simulations. In a SMASH image, multiple lines of k-space are generated simultaneously through combinations of magnetic resonance signals in a radiofrequency coil array. Here, effects of noise correlations between array elements as well as new correlations introduced by the SMASH reconstruction procedure are assessed. SNR and SNR efficiency in SMASH images are compared with results using traditional array combination strategies. Under optimized conditions, SMASH achieves the same average SNR efficiency as ideal pixel-by-pixel array combinations, while allowing imaging to proceed at otherwise unattainable speeds. The k-space nature of SMASH reconstructions can lead to oscillatory spatial variations in noise standard deviation, which can produce local enhancements of SNR in particular regions.

Abdomen↗

Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH).

Spatial resolution in single-shot imaging is limited by signal attenuation due to relaxation of transverse magnetization. This effect can be reduced by minimizing acquisition times through the use of short interecho spacings. However, the minimum interecho spacing is constrained by limits on gradient switching rates, radiofrequency (RF) power deposition and RF pulse length. Recently, simultaneous acquisition of spatial harmonics (SMASH) has been introduced as a method to acquire magnetic resonance images at increased speeds using a reduced number of phase-encoding gradient steps by extracting spatial information contained in an RF coil array. In this study, it is shown that SMASH can be used to reduce the effects of relaxation, resulting in single-shot images with increased spatial resolution without increasing imaging time. After a brief theoretical discussion, two strategies to reduce signal attenuation and increase spatial resolution in single-shot imaging are introduced and their performance is evaluated in phantom studies. In vivo single-shot echoplanar imaging (EPI), BURST, and half-Fourier single-shot turbo spin-echo (HASTE) images are then presented demonstrating the practical implementation of these resolution enhancement strategies. Images acquired with SMASH show increased spatial resolution and improved image quality when compared with images obtained with the conventional acquisitions. The general principles presented for imaging with SMASH can also be applied to other partially parallel imaging techniques.

Computer Simulation↗