Search PubMed⌕ Search

Biomedical subjects

W E Lambert

Publications and source records attributed to W E Lambert.

At least 91 records · Page 5Linked to original sources

Liquid chromatography-mass spectrometry in forensic toxicology.

Liquid chromatography-mass spectrometry has evolved from a topic of mainly research interest into a routinely usable tool in various application fields. With the advent of new ionization approaches, especially atmospheric pressure, the technique has established itself firmly in many areas of research. Although many applications prove that LC-MS is a valuable complementary analytical tool to GC-MS and has the potential to largely extend the application field of mass spectrometry to hitherto "MS-phobic" molecules, we must recognize that the use of LC-MS in forensic toxicology remains relatively rare. This rarity is all the more surprising because forensic toxicologists find themselves often confronted with the daunting task of actually searching for evidence materials on a scientific basis without any indication of the direction in which to search. Through the years, mass spectrometry, mainly in the GC-MS form, has gained a leading role in the way such quandaries are tackled. The advent of robust, bioanalytically compatible combinations of liquid chromatographic separation with mass spectrometric detection really opens new perspectives in terms of mass spectrometric identification of difficult molecules (e.g., polar metabolites) or biopolymers with toxicological relevance, high throughput, and versatility. Of course, analytical toxicologists are generally mass spectrometry users rather than mass spectrometrists, and this difference certainly explains the slow start of LC-MS in this field. Nevertheless, some valuable applications have been published, and it seems that the introduction of the more universal atmospheric pressure ionization interfaces really has boosted interests. This review presents an overview of what has been realized in forensic toxicological LC-MS. After a short introduction into LC-MS interfacing operational characteristics (or limitations), it covers applications that range from illicit drugs to often abused prescription medicines and some natural poisons. As such, we hope it can act as an appetizer to those involved in forensic toxicology but still hesitating to invest in LC-MS.

Chromatography, Liquid↗

A study of respiratory illnesses in infants and nitrogen dioxide exposure.

Toxicologic and epidemiologic studies have elevated concern that exposure to nitrogen dioxide (NO2) in outdoor and indoor air may increase the frequency and severity of respiratory infections. We have developed and implemented a prospective cohort study to test the hypothesis that exposure to NO2 increases the incidence and severity of respiratory infections during the first 18 mo of life. This study, which was based on extensive pilot research, was designed to address the potential limitations of misclassification, confounding, and inadequate power. Enrollment of 1,315 subjects has been completed. This paper reviews the methods used in the study, characteristics of the enrolled subjects, NO2 concentrations in the homes of study participants, and rates of illness occurrence.

Air Pollution, Indoor↗

Evaluation of the relationship between heart rate and ventilation for epidemiologic studies.

Estimation of pulmonary exposure and dose in air pollution epidemiology has been impaired by the lack of methods for directly measuring ventilation in ambulatory subjects. Heart-rate monitoring offers an approach to estimate ventilation by using ventilation-on-heart-rate (VE-HR) regressions established during exercise testing to estimate ventilation in the field. Conventional methods and protocols for testing were used to evaluate the relationship between VE and HR during three tasks: (1) exercising on a cycle ergometer, (2) lifting, and (3) vacuuming. The relationship between VE and HR was curvilinear and was best fit with linear regression models, using a natural log transformation of VE. Considerable interindividual variability in slopes and intercepts was observed across all types of exercise tests. The variability about the fitted regression lines for individual subjects was minimal; for example, individual R2 values for the maximum exercise test on 15 men ranged from 0.90 to 0.99 (mean = 0.97). The regression slopes established during upper-body exercise were greater by approximately 30%, relative to those derived in lower-body exercise (paired t test, p < .001). However, VE-HR regression slopes derived from tests in which progressively increasing workloads were used were comparable to those obtained during variable and nonprogressive protocols. These findings indicate that predictive accuracy is maximized by deriving VE-HR regressions for individual subjects and for both lower- and upper-body activities.

Adolescent↗

Oronasal distribution of ventilation at different ages.

The route of breathing, oral or nasal, is a determinant of the doses of inhaled pollutants delivered to target sites in the upper and lower respiratory tracts. We measured partitioning of ventilation, using a divided oronasal mask during a submaximal exercise test, in 37 male and female subjects who ranged in age from 7 to 72 y. The following four patterns of breathing were evident during exercise: (1) nasal only (13.5%), nasal shifting to oronasal (40.5%), oronasal only (40.5%), and oral only (5.4%). Children (i.e., 7-16 y of age) displayed more variability than adults with respect to their patterns of ventilation with exercise. Young adults (i.e., 17-30 y of age) who initially breathed nasally with exercise switched to oral ventilation at a lower percentage of the previously measured maximum ventilation (10.8%) than older subjects (31.8%). The partitioning of ventilation between the nasal and oral routes follows complex patterns that cannot be predicted readily by the age, gender, or nasal airway resistance of the subject.

Adolescent↗

Screening, identification, and quantitation of benzodiazepines in postmortem samples by HPLC with photodiode array detection.

A high-performance liquid chromatographic method has been developed for the simultaneous analysis of eight frequently used benzodiazepines and some of their metabolites in postmortem samples. The method includes a liquid-liquid extraction with n-hexane-ethyl acetate (70:30, v/v), gradient elution of a C8 reversed-phase column with an alkaline water-methanol eluent free of buffer salts, and photodiode array detection. This allows rapid detection, a purity check, identification, and quantitation of the eluting peaks. Recovery and linearity data are good for the chosen parent compounds. The validated procedure has been applied routinely in forensic toxicological analyses. The elimination of the buffer from the eluent results in a robust procedure, free of technical problems and long rinsing periods.

Acetates↗

Determination of chloral hydrate and metabolites in a fatal intoxication.

A young woman (32 years old) was found dead in her house. Screening of postmortem blood with enzyme multiplied immunoassay (EMIT) detected benzodiazepines, salicylic acid derivatives, and caffeine. These compounds were present in nontoxic concentrations as confirmed by thin-layer chromatography and high-performance liquid chromatography. The Fujiwara-Ross reaction on blood revealed the presence of chlorinated hydrocarbons in high concentrations. An optimized gas chromatographic method with electron capture detection allowed the identification and quantitation of chloral hydrate and both its metabolites, 2,2,2-trichloroethanol and trichloroacetic acid, in the available postmortem samples. The tissue concentrations indicated that chloral hydrate ingestion could be identified as the cause of this fatality.

Adult↗

Systematic toxicological analysis of basic drugs by gradient elution of an alumina-based HPLC packing material under alkaline conditions.

A high-performance liquid chromatographic system based on gradient elution of an alumina packing material coated with polybutadiene is presented. The chromatographic eluent is a mixture of methanol and water, both containing 0.0125M NaOH. The effluent is monitored by photodiode array detection. The system allows detection and identification of more than 130 toxicologically relevant substances (mainly basic compounds) and has already been successfully applied to screen more than 500 extracts of fresh or postmortem specimens (blood, urine, tissue homogenates, and stomach contents).

Chromatography, High Pressure Liquid↗

Application of high-performance liquid chromatography to a fatality involving azide.

We describe a fatality resulting from the ingestion of sodium azide. Initial routine toxicological screening of the blood showed a negative result, but pathological findings as well as findings at the scene itself led to the search for azide. The azide was quantitated in all available postmortem samples (blood, stomach contents, liver, kidney, and bile) and was present in all of these matrices in the following concentrations (micrograms per milliliter or micrograms per gram): 262, 754, 14, 205, and 1283, respectively. The method is based on precolumn derivatization with 3,5-dinitrobenzoyl chloride followed by isocratic high-performance liquid chromatography and photodiode array detection. Methemoglobin and cyanide content in the blood were also elevated.

Adult↗

Identification of alpha-phenylethylamine in judicial samples.

alpha-Phenylethylamine was recently identified in samples from several judicial cases using chromatographic (high-performance liquid chromatography-diode-array detection, gas chromatography-mass spectrometry, and gas chromatography-Fourier transform infrared detection) and spectrometric (nuclear magnetic resonance) techniques. In the first case, 1 kg of a white powder was found in a basement laboratory. It contained caffeine and more than 15% alpha-phenylethylamine. In the second case, two white powders were seized from a female. One powder consisted of pure amphetamine, and the other was a mixture of caffeine, amphetamine, and alpha-phenylethylamine. Four months later, a couple, who were known drug users, were found dead in their apartment. Urine samples of both victims contained large amounts of amphetamine together with alpha-phenylethylamine. Recently, 0.13 kg of a white powder and 0.30 kg of an orange powder were seized during a law enforcement operation. Both powders were mixtures of caffeine, amphetamine, and alpha-phenylethylamine. The data presented demonstrate the recent and unrelated repetitive occurrence of alpha-phenylethylamine in the circuit of illicit drugs.

Chromatography, High Pressure Liquid↗

Quantitative gas chromatographic analysis of 3-cyano-3,3-diphenylpropionic acid, the acidic metabolite of bezitramide (Burgodin), in urine.

A sensitive gas chromatographic procedure with nitrogen-phosphorus detection was developed for the quantitative determination of 3-cyano-3,3-diphenylpropionic acid, the acidic metabolite of the narcotic analgesic bezitramide (Burgodin). Gas chromatography with mass spectrometric detection was used for confirmation. An internal standard, 5-cyano-5,5-diphenylvaleric acid, was synthesized and purified in our laboratory. The compound was extracted from 5 mL of hydrolyzed urine with n-hexane-ethyl acetate (85:15, v/v). Derivatization of the extract with an ethereal diazomethane solution was performed immediately before chromatographic analysis. Under the described conditions, the quantitation limit for 3-cyano-3, 3-diphenylpropionic acid in urine was 10 ng/mL. The extraction recovery was 82%. The calibration graph was linear over the concentration range from 10 to 500 ng/mL; at a 100-ng/mL concentration, within-day and day-to-day percent coefficients of variation of 1.9 and 3.7%, respectively, were obtained. Urine samples from 16 persons suspected of using bezitramide were analyzed, and they revealed metabolite concentrations that ranged from 10.5 to 88 ng/mL.

Acetates↗

Quantitative determination of amphetamine and alpha-phenylethylamine enantiomers in judicial samples using capillary gas chromatography.

alpha-Phenylethylamine was recently reported by us in various samples seized from the illicit drug circuit. At first, alpha-phenylethylamine was identified in powders that generally contained amphetamine and caffeine. Then, a couple, who were known drug users, was found dead in their apartment. Urine samples from both victims contained large amounts of amphetamine and alpha-phenylethylamine. All of the positive samples were re-examined with gas chromatography to determine the chirality of the detected drug or drugs. The homochiral derivatizing reagent N-trifluoroacetyl-L-prolyl chloride was used to convert the drug enantiomers into their corresponding diastereomeric derivatives. These derivatives were separated on an achiral stationary phase and detected using either flame ionization detection (FID) or on-line Fourier-transform infrared spectrometry (FTIR) for quantitative or qualitative purposes, respectively. Excellent separation was realized between all diastereomeric derivatives, and interference of excess, nonvolatile derivatizing reagent was reduced to a minimum. All powder samples consisted of racemic mixtures for alpha-phenylethylamine and for amphetamine. The urine samples also contained both enantiomers of alpha-phenyl ethylamine and amphetamine, albeit in varying proportions. These findings again substantiate the synthetic origin of alpha-phenylethylamine, attributing its presence in the urine of both victims to intentional or accidental intake. The disproportionate isomeric composition found in the urine samples confirms previous reports of a stereoselective metabolism for amphetamine enantiomers and suggests a similar pharmacokinetic profile for alpha-phenylethylamine.

Amphetamine↗

Tissue distribution of amphetamine isomers in a fatal overdose.

A young man (22 years old) died of a cardiorespiratory arrest a few hours following admission to the emergency department of a hospital. He was found lying seriously ill in the parking lot of a dance club. Screening of postmortem blood and urine with enzyme multiplied immunoassay (EMIT) detected only amphetamines, caffeine, and cotinine. Further screening of blood, urine, and stomach contents with thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) was negative for all three matrices. Specific conditions for amphetamines were used for the gas chromatographic (GC) screening (GC-mass spectrometric [MS] and GC-nitrogen-phosphorus detection). This resulted in the preliminary identification of amphetamine in both blood and urine. Confirmation of the presence of amphetamine in all available postmortem specimens was provided by mass and infrared spectral data (GC-MS and GC-Fourier transform infrared spectrometry) after derivatization. Quantitative results and differentiation between the enantiomers of amphetamine were obtained after chiral derivatization. The calculated concentrations disclosed amphetamine ingestion as the cause of this fatality.

Adult↗

Quantitative gas chromatographic analysis of [1-(4-piperidinyl)-1,3-dihydro-2H-benzimidazole-2-one], the basic metabolite of bezitramide (Burgodin), in human urine.

A gas chromatographic procedure with nitrogen-phosphorus detection was developed for the quantitative determination of 1-(4-piperidinyl)-1,3-dihydro-2H-benzimidazole-2-one, the basic metabolite of the narcotic analgesic bezitramide (Burgodin), in urine. Gas chromatography with mass spectrometric detection was used for confirmation. An internal standard with great structural resemblance to the basic metabolite was synthesized in our laboratory. For the isolation of the compound from urine, a liquid-liquid extraction with chloroform/isopropanol was performed. The extract was derivatized with pentafluorobenzoylchloride immediately before chromatographic analysis. The calibration curve was linear over a broad concentration range (10 to 1000 ng/mL). The quantitation limit was 10 ng/mL, and at a 250-ng/mL concentration, coefficients of variation of 2.8 and 3.4% were obtained for within-day and between-day precision, respectively. The selectivity and accuracy of the method were satisfactory. Out of 150 urine samples, mainly from persons suspected of using bezitramide or from known drug abusers, 22 samples revealed basic metabolite concentrations that ranged from 17.0 to 1695.5 ng/mL. The described method allows the quantitation of the basic metabolite of bezitramide with high sensitivity, selectivity, and precision. It can also be used to determine bezitramide abuse and to establish bezitramide overdoses.

2-Propanol↗

Analysis of flecainide and two metabolites in biological specimens by HPLC: application to a fatal intoxication.

A few days after her admittance to a hospital for a suicide attempt with benzodiazepines, a 15-year-old girl was found dead in bed. At autopsy, no specific anatomo-pathologic cause of death was identified. Systematic toxicological analysis (HPLC-DAD, GC-NPD, and GC-MS) of postmortem blood and urine revealed the presence of high concentrations of flecainide and its two major metabolites. Flecainide is a class IC anti-arrhythmic drug causing a decreased intracardiac conduction velocity in all parts of the heart. To identify and quantitate flecainide together with its metabolites in blood, urine, and other toxicologically relevant matrices, a new method was developed using high-performance liquid chromatography with diode-array detection. All compounds were separated on a Hypersil BDS phenyl column using water, methanol, and 1.5M ammonium acetate in a gradient system. Chromatographic analysis was preceded by an optimized solid-phase extraction procedure on RP-C18 extraction columns. The flecainide concentrations in blood and urine were 18.73 and 28.3 mg/L, respectively, and the metabolites were detected only in urine at the following concentrations: 9.4 mg/L for meta-O-dealkylated flecainide and 8.59 mg/L for meta-O-dealkylated flecainide lactam. Based on these results, it was concluded that the suicide was consistent with an overdose of this anti-arrhythmic drug.

Adolescent↗