Isotope-dilution mass spectrometry in clinical chemistry.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to W E Lambert.
Explore the source record for details and available documents.
We describe how riboflavin can be precisely and accurately measured in serum and urine. A structural analog, isoriboflavin, is used as an internal standard. Urine samples are prepared by adding the internal standard and trichloroacetic acid. For serum, proteins are denatured with trichloroacetic acid. A simple Sep-pak treatment of the supernate removes contaminating interferents. Within- and between-run precision is reflected by respective CVs of 2.2 and 4.9% for urine at 180 micrograms/L and 4.4 and 7.3% for serum at 10 micrograms/L. The standard curve is linear far beyond the concentrations encountered in serum and urine. The detection limit is estimated to be 10 micrograms/L and 1 microgram/L for urine and serum, respectively. The normal reference interval, as determined from 50 results for each matrix, is 36 to 349 micrograms/g of creatinine (mean 112 micrograms/g) for urine and 5.5 to 14.4 micrograms/L (mean 8.8 micrograms/L) for serum. Both distributions are skewed. The method is suited for routine use.
A sensitive and specific high-performance liquid chromatographic (HPLC) method for the determination of cortisol in only 200 microliters of serum is described. Cortisol and two internal standards, 19-nortestosterone (IS1) and 6 alpha-methylprednisolone (IS2) are extracted with dichloromethane and analyzed on a C18 reversed-phase column eluted with a mobile phase of methanol:water at a flow rate of 0.75 ml/min. Ultraviolet absorption at 254 nm is used for detection and quantitation is performed by peak height ratio measurement. Using 200 microliters of serum, the lower limit of detection for cortisol is 10 ng/ml, the analytical recovery is 104 +/- 3.6% (n = 8), and the day-to-day precision was 1.69% at a level of 90 ng/ml (n = 16). Cortisol values obtained by this method were generally lower than those obtained by radioimmunoassay or by fluorometry. A serum pool was analyzed both by HPLC and by isotope dilution/mass spectrometry (ID/MS). A mean value of 90.1 ng/ml was obtained by HPLC (n = 16, CV = 1.7%), whereas ID/MS yielded a mean of 90.8 ng/ml (n = 28, CV = 0.4%). These results clearly demonstrate the high specificity and the accuracy of the HPLC procedure. The use of two internal standards not only compensates for losses during the sample manipulation but also prevents erroneous results in case of medication by either of these two products.
Explore the source record for details and available documents.
A quantitative determination of physiological levels of all-trans-retinoic acid (vitamin A acid) in human serum has been developed. A double-phase extraction of 3.5 ml of serum followed by a specific and sensitive high performance liquid chromatography procedure allowed measurement of levels down to 1 ng/ml. Serum concentrations in 37 fasting volunteers ranged from 2.7 to 4.2 ng/ml and fitted a normal-Gaussian distributional shape with a mean value of 3.5 ng/ml and SD of 0.4 ng/ml, as demonstrated by the Kolmogorov-Smirnov test.
Different high performance liquid chromatographic systems were applied to the investigation of vitamin A metabolism in subjects undergoing haemodialysis. Plasma levels of retinol, retinyl esters and retinoic acid were measured. There was a significant elevation of plasma retinol and dialysis failed to normalise this level. No correlation with plasma concentrations of creatinine or urea was found. No differences in retinyl ester and retinoic acid levels were observed between healthy subjects and haemodialysis patients. These results suggest that retinol accumulation is not caused by a deficiency in its oxidative metabolism.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A dichotic listening paradigm was used to study the relation of eye movement to cerebral lateralization. The eye movements of right-handed subjects were recorded during verbal and nonverbal dichotic-listening tasks. Subjects given a verbal dichotic-listening task made significantly more rightward than leftward eye movements and showed more accuracy and speed in processing information presented to the right than to the left ear. Subjects given a nonverbal dichotic-listening task made significantly more leftward eye movements and processed better information presented to the left ear. These findings suggest a potentially strong link between the direction of lateral eye movement during dichotic listening tasks and left- and right-ear advantages in performance on such tasks. They also suggest that both eye movement and ear performance may be related to cerebral laterality and when examined in combination both could provide valuable information for the further study of hemispheric specialization.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.