Search PubMed⌕ Search

Biomedical subjects

W E Lambert

Publications and source records attributed to W E Lambert.

At least 37 records · Page 2Linked to original sources

Quantitative colorimetric determination of urinary p-aminophenol with an automated analyzer.

We developed an automated colorimetric method for the quantitative determination of p-aminophenol with a Cobas Mira analyzer. The procedure can be used for the biological monitoring of human exposure to aniline. An absorbed aniline dose is extensively oxidized to p-aminophenol, which is excreted in urine mainly as glucurono- and sulfo- conjugates. After enzymatic hydrolysis, we reacted the free compound with resorcinol in the presence of manganese ions to form an indophenol dye, which is measured at 550 nm. Excellent accuracy (102.8%, 103.9%, and 96.8% at 2.5, 50, and 90 mg/L, respectively) and precision (7.7%, 2.1%, and 0.8% CV for within-run and 11.1%, 4.7%, and 4.6% for total reproducibility at 2.5, 50, and 90 mg/L, respectively) were achieved over a linear concentration range of 2.0 to 100 mg/L. The detection limit was 0.9 mg/L and no significant interference (except for o-aminophenol) was found for several investigated drugs and related compounds. The proposed method was used for a stability study and to analyze several samples from an occupational health screen.

Adult↗

Analysis of cocaine, benzoylecgonine, and cocaethylene in urine by HPLC with diode array detection.

A solid phase extraction method was developed for the isolation of cocaine, benzoylecgonine, and cocaethylene from urine followed by high-performance liquid chromatography/diode array detection. The application of a new solid hybrid phase extraction technology produced much cleaner extracts than conventional extraction procedures and made the selective extraction of substances with different polarities possible. Two internal standards with great structural resemblance to benzoylecgonine (a carboxylic acid) and to the two esters, cocaine and cocaethylene, respectively, were synthesized. A linear response over a broad concentration range was obtained. The sensitivity, specificity, and accuracy were satisfactory for each analyte. Hydrolysis of cocaine and cocaethylene to benzoylecgonine during extraction and analysis was less than 0.5%. The method described can be used to corroborate cocaine use, to establish cocaine overdoses, and to study pharmacological effects of cocaine and its metabolites.

Chromatography, High Pressure Liquid↗

Nitrogen dioxide and respiratory illness in children. Part IV: Effects of housing and meteorologic factors on indoor nitrogen dioxide concentrations.

In a prospective study of infants' exposure to nitrogen dioxide (NO2)* and respiratory illness, NO2 concentrations were measured in more than 1,400 homes in Albequerque, NM, From January 1988 through June 1991 (Health Effects Institute Research Report Number 58, Parts I, II and III). This report characterizes the variability in indoor NO2 concentrations across seasons and years, and identifies factors associated with variation in concentrations between homes and across seasons. In regression analyses of winter data, NO2 levels in the infants' bedrooms were predominately determined by the presence of gas cooking ranges with continuously burning pilot lights, the presence of wall or floor furnaces, the use of the stove for space heating, and the square footage of the living space. These findings are consistent with previously published analysis of data from homes in other U.S. cities. Relatively small differences in seasonal NO2 levels were observed across years. The correlation coefficient (r) of bedroom NO2 levels obtained in the same homes was 0.66 over two winters and 0.48 over two summers. For homes that had gas cooking ranges with continuously burning pilot lights, the NO2 bedroom concentrations differed, on average, less than 5 parts per billion (ppb) across winters. These differences were hypothesized to be caused by differences in the use of indoor NO2 sources, ventilation, and ambient (outdoor) NO2 levels. We were, however, unable to demonstrate an association between year-to-year differences in seasonal indoor NO2 concentrations and reported use of cooking range, furnace, or heater, or ambient NO2 levels, or temperature.

Air Pollution, Indoor↗

Micronutrient levels in HIV-1-infected children.

OBJECTIVE: Micronutrients (zinc, copper, selenium, vitamin A, E, and carotenoids) are essential for the integrity of host defences. This study was designed to determine the prevalence of abnormalities of the micronutrient levels in HIV-1-seropositive children. DESIGN: Prospective study. SETTING: The study was performed on HIV-1-infected children at the Paediatric Haematology and Oncology Unit of Toulouse Hospital, France. PATIENTS: Twenty-one children, suffering from HIV-1 infection and 21 control subjects of similar age (2-9 years) were included in the study. In the HIV-1-infected children, two subgroups were considered according to stage (non-AIDS or AIDS), based on the Centers for Disease Control and Prevention 1987 criteria. RESULTS: The first statistically significant deficiencies occurred at non-AIDS stage and were confirmed at AIDS stage: P < 0.05 for lycopene, retinol, tocopherol and P < 0.001 for transthyretin and serum albumin. Levels of copper (40%) and long-chain polyunsaturated fatty acids (21%) were higher in the non-AIDS group than the controls. CONCLUSION: Biological impairing of the micronutrient levels was observed in the non-AIDS stage without clinical sign. This information is useful in delineating eventual and well considered nutritional intervention strategies that may improve the clinical status of HIV-1-infected children and perhaps alter the course of their disease.

Carotenoids↗

Air pollution.

Despite progress in improving ambient air quality and reducing personal exposures to air pollutants in indoor settings, population exposures to air pollutants remain widespread and are an important public health concern. Many air pollutants are associated with adverse health effects; the most serious include development and exacerbation of asthma, loss of lung function, impaired neurobehavioral development, and death. These outcomes are the focus of current health effects research on environmental tobacco smoke and radon in indoor settings, and lead, ozone, and particulate matter outdoors. Advances in methods to measure exposures to specific pollutants and the identification of markers of individual susceptibility are providing improved data on the relation of exposure and disease, and, in turn, will improve efforts to protect public health.

Air Pollutants↗

Determination of embutramide in biological matrices by gas chromatography with nitrogen-phosphorus detection.

Embutramide is a general anesthetic having a strong narcotic effect on the central nervous system where it paralyzes the brain center that controls respiration. It is a constituent of T61, a veterinary euthanasia drug. This paper describes a gas chromatographic procedure using nitrogen-phosphorus detection for the determination of embutramide in biological matrices. The drug and the internal standard (ambucetamide) are extracted with dichloromethane under alkaline conditions. The method is linear from 100 to 3000 ng/ml. The within-day and day-to-day coefficients of variation range from 5.1 to 5.7% and from 9.1 to 10.0%, respectively. The recovery is above 80% while the minimum detectable level under the conditions described is 40 ng/ml analyzing a 1-ml or a 1-g aliquot of a sample (blood or tissue). The method is also applied to different samples from dogs euthanized with T61.

Amides↗

Standardization of reagents and methods used in cytological and histological practice with emphasis on dyes, stains and chromogenic reagents.

The need for the standardization of reagents and methods used in the histology laboratory is demonstrated. After definitions of dyes, stains, and chromogenic reagents, existing standards and standards organizations are discussed. This is followed by practical instructions on how to standardize dyes and stains through the preparation of reference materials and the development of chromatographic methods. An overview is presented of the problems concerned with standardization of the Romanowsky-Giemsa stain for cytological and histological application. Finally, the problem of how to convince routine dye and stain users of the need for standardization in their histology laboratories is discussed.

Animals↗

Nitrogen dioxide and respiratory illness in children. Part III: Quality assurance in an epidemiologic study.

This report describes the quality assurance and quality control program developed for the previously reported epidemiologic study of nitrogen dioxide (NO2) and respiratory illness in children (Health Effects Institute Research Report 58, Parts I and II). The specific aims of the program were to make certain that data were sufficiently accurate, complete, verifiable, and retrievable. The quality assurance and quality control program consisted of: a written protocol, standard operating procedures, written records, a project management system, appropriate data processing, data verification, and data analysis planning, and was staffed by qualified and appropriately trained personnel. Within the activities of the overall program, two focused quality assurance studies were conducted. During the first of these focused studies, parents maintained a calendar-diary of their child's daily respiratory symptoms. Telephone interviews were conducted at intervals of two weeks, and parents used the calendars to report on symptom occurrence since the previous call. To assess the comparability of illness events based on symptom reports from the parents with usual clinical diagnostic methods, nurse practitioners examined children during illness, and office and clinic records of outpatient visits were reviewed. Using the parent reports, respiratory illnesses were defined as symptom episodes of at least two consecutive days; lower respiratory illnesses included at least one day of either wet cough or wheeze. Runny or stuffy nose was reported for 93% of illnesses; and wet cough for 33% and wheeze for 6% of illnesses. In comparison with the diagnoses made by a nurse practitioner, parent reports of wet cough or wheeze were sensitive (93.4%) for detecting lower respiratory illnesses, but nonspecific (with specificity of only 24.2%). The majority of the false-positive lower respiratory illnesses had the symptom of wet cough. The comparison of parent reports with outpatient records provided similar findings. These findings indicate that standardized reporting of respiratory illnesses can be achieved with regular telephone interviews, but the classification of specific illnesses from the observations of parents' information may differ from diagnoses made by clinicians. The second focused quality assurance study evaluated the measurement error associated with the parents' use of passive diffusion samplers for NO2. Midway through the study, technicians conducted home visits to assess compliance with stated procedures, and to make independent measurements of NO2. Based on criteria for placement and use of the samplers, conditions of noncompliance were observed on about 40% of visits.(ABSTRACT TRUNCATED AT 400 WORDS)

Data Collection↗

Pharmacokinetics of acitretin.

Acitretin, the metabolite of etretinate, is eliminated far more rapidly from the human body than is etretinate. It has therefore been suggested that only a short period of contraception would be required following the completion of long-term therapy. However, recent studies have demonstrated the presence of etretinate in the plasma of acitretin-treated patients. In this paper, we review the results of studies at our centre in view of the recently discovered metabolic pathways for acitretin. Re-esterification of acitretin to etretinate, however, results in a loss of the metabolic advantages of acitretin. Because of this new knowledge, the recommended contraception period after acitretin therapy has been lengthened to 2 years.

Acitretin↗

Simultaneous determination of endogenous retinoic acid isomers and retinol in human plasma by isocratic normal-phase HPLC with ultraviolet detection.

We describe a rapid and simple procedure for the simultaneous quantitation of endogenous 13-cis-retinoic acid, all-trans-retinoic acid, and retinol by isocratic normal-phase HPLC with ultraviolet detection, in 0.5 mL of human plasma. A silica adsorption column was eluted with n-hexane:2-propanol:acetic acid (200:0.7:0.135 by vol) at 0.9 mL/min, and the effluent monitored at 350 nm. The arotinoid ethylsulfonic acid Ro 15-1570 was used as the internal standard. High sensitivity, allowing quantitation of physiological concentrations, was achieved, particularly for the retinoic acid isomers. The detection limits were 0.5 microgram/L in plasma for both 13-cis- and trans-retinoic acid, and 10 micrograms/L for retinol. The CVs for between-day determinations of the lowest quality-control concentration (n = 12) were 4.8% for 13-cis-retinoic acid, 3.4% for trans-retinoic acid, and 3.0% for retinol. The mean (+/- SD) concentrations of 13-cis-retinoic acid (1.79 +/- 0.56 microgram/L), trans-retinoic acid (1.35 +/- 0.42 microgram/L), and retinol (533 +/- 58 micrograms/L) measured in plasma from 22 healthy volunteers agreed well with those previously reported.

Adult↗

Comparability of parent reports of respiratory illnesses with clinical diagnoses in infants.

In a cohort study of respiratory illnesses from birth through age 18 months, the investigators assessed the occurrence of illness by telephone reports of respiratory symptoms. To assess the comparability of illness events based on symptom reports with usual clinical modalities, a nurse practitioner examined children during illnesses, and office and clinic records of outpatient visits were reviewed. Respiratory illnesses were defined as symptom episodes of at least 2 days; lower respiratory illnesses included at least 1 day of either wet cough or wheeze. This report is based on 10,771 illnesses in the 1,315 subjects enrolled. Runny or stuffy nose was reported for most (93%) illnesses, wet cough in 33%, and wheeze in 6%. In comparison with the diagnoses made by a nurse practitioner, parent report of wet cough or wheeze was sensitive (93.4%) for detecting lower respiratory illnesses, but nonspecific with specificity of only 24.2%. The majority of the false-positive lower respiratory illnesses had the symptom of wet cough. The comparison of parent reports with outpatient records provided similar findings. Standardized reporting of respiratory illnesses can be achieved with a telephone surveillance system but classification of specific illnesses from the surveillance information may differ from diagnoses made by clinicians.

Cohort Studies↗

Nitrogen dioxide and respiratory illnesses in infants.

Nitrogen dioxide is an oxidant gas that contaminates outdoor air and indoor air in homes with unvented gas appliances. A prospective cohort study was carried out to test the hypothesis that residential exposure to NO2 increases incidence and severity of respiratory illnesses during the first 18 months of life. A cohort of 1,205 healthy infants from homes without smokers was enrolled. The daily occurrence of respiratory symptoms and illnesses was reported by the mothers every 2 wk. Illnesses with wheezing or wet cough were classified as lower respiratory tract. Indoor NO2 concentrations were serially measured with passive samplers place in the subjects' bedrooms. In stratified analyses, illness incidence rates did not consistently increase with exposure to NO2 or stove type. In multivariate analyses that adjusted for potential confounding factors, odds ratios were not significantly elevated for current or lagged NO2 exposures, or stove type. Illness duration, a measure of illness severity, was not associated with NO2 exposure. The findings can be extended to homes with gas stoves in regions of the United States where the outdoor air is not heavily polluted by NO2.

Air Pollutants↗

Sources of variability in posterior rhinomanometry.

Sources of variability in nasal airway resistance measured by posterior rhinomanometry were studied in 5 subjects tested on 5 different days and 56 subjects tested on 2 different days. On each day, a questionnaire on upper airway health and nasal symptoms was completed. The mean individual difference in nasal airway resistance between the 2 test days in the group of 56 subjects was 5.3% (SD 52.7%). Between-subject variability accounted for 74.9% and 72.5% of the total variability in the group of 5 and the group of 56 subjects, respectively. For the 5 subjects, by accounting for a change in upper airway symptoms or upper respiratory tract infection that occurred over the 5 test days, there was a significant decrease in the between-subject variability. The difference in sources of variation due to a change in upper airway symptoms was not seen in the group of 56 subjects. We conclude that the largest source of variability in nasal airway resistance is due to between-subject differences.

Adult↗

Environmental tobacco smoke concentrations in no-smoking and smoking sections of restaurants.

To characterize the effectiveness of a local ordinance that restricts smoking in restaurants to one third of the seating area, this study made simultaneous measurements of two markers of environmental tobacco smoke, respirable suspended particles and nicotine, in the smoking and no-smoking sections of seven restaurants. The mean concentrations of respirable suspended particles and nicotine were 40% and 65% lower, respectively, in the no-smoking than in the smoking sections, indicating substantial but not complete protection against exposure.

Air Pollution, Indoor↗

Skin, adipose tissue and plasma levels of acitretin with rare occurrence of esterified acitretin during long-term treatment.

In a previous study acitretin and its 13-cis-metabolite were monitored in the plasma and epidermis of healthy volunteers. They were given 50 mg of trans-acitretin daily. No drug accumulation was observed in the skin, nor in the plasma. The purpose of the present study was to extend the data from non-psoriatic to psoriatic (n = 11) subjects, treated for at least 1 month with 25 mg acitretin. Plasma, skin biopsies and subcutaneous fat samples were analysed using HPLC. Trough levels of acitretin in skin were below the quantification limit, increasing to 28 +/- 16 ng/g within 5 h after dosing. Fat tissue levels exceeded those of skin, with values of 98 +/- 71 ng/g within 5 h after drug intake. In 2 patients, additional samples were taken 3 days post-therapy. Here, concentrations were below the quantification limit in adipose tissue, confirming that acitretin is not stored in subcutaneous fat. Esterification of acitretin into etretinate was observed in 2 subjects. This observation illustrates the recently described new metabolic pathway for acitretin. On both occasions, the unexpected ethylester metabolite was extensively stored in fat tissue.

Acitretin↗

Assessment of heart rate as a predictor of ventilation.

The rate of ventilation and route of breathing (i.e., nasal versus oronasal) are potential determinants of pollutant doses to target sites in the lung. However, the lack of accurate methods for ambulatory measurement of ventilation has hindered estimation of exposure and dose in freely ranging individuals, complicating the interpretation of the relationships among exposure, dose, and response in epidemiological studies. The goal of this project was to develop and validate a method of monitoring ventilation for large-scale epidemiologic investigations. We estimated ventilation for individual subjects from ambulatory heart rate monitoring, using the relationship between ventilation and heart rate that had been obtained during exercise testing. Fifty-eight subjects participated in the study, which included healthy adults and children, and subjects with lung and heart disease. Subjects performed cycle exercise and tasks involving lifting and vacuuming. Work loads of progressive and variable order were used in the testing. Conventional methods were used to measure heart rate and total ventilation, and a sampling mask was developed to measure the partitioning of breathing between oral and nasal routes. The minute ventilation-heart rate relation was evaluated under steady-state and varying work loads. In a second phase, subjects wore wristwatch monitors that recorded their heart rates, minute by minute, throughout the day. Subjects recorded activities, locations, and levels of exertion. Two 16-hour monitoring periods were obtained from each subject. The laboratory findings documented considerable intersubject variability in the minute ventilation-heart rate relation with a two- to five-fold range in the coefficients describing the change in ventilation relative to heart rate. This variation implies that individual testing is required to derive accurate predictive equations. Minute ventilation-heart rate regressions for the maximal progressive exercise test and for the test with a nonprogressive submaximal work load sequence were comparable, indicating that varying the sequence of work loads does not substantially affect the minute ventilation-to-heart rate ratio. During upper body work (e.g., lifting), the minute ventilation-to-heart rate ratio was one-third greater than during lower body exercise. Diverse patterns of partitioning breathing between oral and nasal routes were observed with increasing oral ventilation in most subjects as work load increased. In the field, heart rate and activity patterns were monitored successfully in adults and children with low rates of instrument failure and noncompliance.(ABSTRACT TRUNCATED AT 400 WORDS)

Adolescent↗

Nitrogen dioxide and respiratory illness in children. Part I: Health outcomes.

We have carried out a prospective cohort study to test the hypothesis that exposure to nitrogen dioxide increases the incidence and severity of respiratory infections during the first 18 months of life. Between January 1988 and June 1990, 1,315 infants were enrolled into the study at birth and followed with prospective surveillance for the occurrence of respiratory infections and monitoring of nitrogen dioxide concentrations in their homes. The subjects were healthy infants from homes without smokers; they were selected with stratification by type of cooking stove at a ratio of four to one for gas and electric stoves. Illness experience was monitored by a daily diary of symptoms completed by the mother and a telephone interview conducted every two weeks. Illnesses with wheezing or wet cough were classified as involving the lower respiratory tract; all other respiratory illnesses were designated as involving the upper respiratory tract. Exposure to nitrogen dioxide was estimated by two-week average concentrations measured in the subjects' bedrooms with passive samplers. This analysis is limited to the 1,205 subjects completing at least one month of observation; of these, 823 completed the full protocol, contributing 82.8% of the total number of days during which the subjects were under observation. Incidence rates for all respiratory illnesses, all upper respiratory illness, all lower respiratory illnesses, and lower respiratory illness further divided into those with any wheezing, or wet cough without wheezing, were examined within strata of nitrogen dioxide exposure at the time of the illness, nitrogen dioxide exposure during the prior month, and type of cooking stove. Consistent trends of increasing illness incidence rates with increasing exposure to nitrogen dioxide were not evident for either the lagged or unlagged exposure variables. The effect of nitrogen dioxide exposure on illness occurrence during at-risk intervals of two weeks' duration was examined using the generalized estimating equation approach. In these multivariate analyses, none of the odds ratios was significantly elevated for unlagged nitrogen dioxide exposures, lagged nitrogen dioxide exposures, or stove type. Duration of illness was assessed in relation to the same exposure variables; illness duration and nitrogen dioxide exposure were not associated. We have found that indoor exposure to nitrogen dioxide is associated with neither the incidence nor the duration of respiratory illnesses. The study was designed to have sufficient power to detect effects of nitrogen dioxide exposure of magnitudes previously reported and in a range relevant to public health concern; the lack of association cannot be attributed to potential bias from misclassification of outcome or exposure.(ABSTRACT TRUNCATED AT 400 WORDS)

Air Pollutants↗