Search PubMed⌕ Search

Biomedical subjects

W E Lambert

Publications and source records attributed to W E Lambert.

At least 19 recordsLinked to original sources

Simultaneous determination of in total 17 opium alkaloids and opioids in blood and urine by fast liquid chromatography-diode-array detection-fluorescence detection, after solid-phase extraction.

A fast liquid chromatographic method with tandem diode array-fluorescence detection for the simultaneous determination of in total 17 opium alkaloids and opioids is presented. Blank blood and urine samples (1 ml) were spiked with different concentrations of a standard mixture, as well as with the internal standard, butorphanol (2000 ng/ml). After solid-phase extraction, based on weak cation exchange (Bond Elut CBA SPE columns), the extracts were examined by HPLC-DAD-FL. By using a "high-speed" phenyl column (53 x 7.0 mm I.D., particle size 3 microm) eluted with a gradient system (A: water-methanol (90:10, v/v), B: methanol, both containing 25 mM triethylammoniumformate (pH(A) = 4.5)) all compounds could be baseline separated within 12 min. The method was validated and its applicability was demonstrated by the analysis of real-time forensic cases.

Chromatography, High Pressure Liquid↗

Heroin impurity profiling: trends throughout a decade of experimenting.

Heroin is still one of the most frequently abused drugs of today. All over the world, law enforcement agencies try to eradicate the illicit production and trafficking of this potent and highly addictive narcotic. To this aim, important information is provided by physical and chemical toxicological analysis of confiscated samples, with special attention for the identification and the quantification of minor components, such as the impurities related to the origin and manufacturing. By combining these data complex characterisations, i.e. impurity profiles, chemical signatures or fingerprints, can be obtained and used for comparative analysis. This review focuses on heroin impurity profiling during the 1990s, proclaimed by the United Nations as the 'Decade for Eradicating Drug Abuse'. Special attention will be given to the new trends in analytical techniques as well as in data handling strategies, so called chemometrics, to produce these profiles. The latter can be used in comparative analysis of seized heroin samples for tactical (batch-to-batch comparison) and strategic (origin determination) intelligence purposes.

Chemistry Techniques, Analytical↗

A fatal case of serotonin syndrome after combined moclobemide-citalopram intoxication.

We present a case involving a fatality due to the combined ingestion of two different types of antidepressants. A 41-year-old Caucasian male, with a history of depression and suicide attempts, was found deceased at home. Multiple containers of medication, the MAO-inhibitor moclobemide (Aurorix), the SSRI citalopram (Cipramil), and the benzodiazepine lormetazepam (Noctamid) as active substance, as well as a bottle of whiskey were present at the scene. The autopsy findings were unremarkable, but systematic toxicological analysis (EMIT, radioimmunoassay, high-performance liquid chromatography-diode-array detection [HPLC-DAD], gas chromatography-nitrogen-phosphorus detection, and gas chromatography-mass spectrometry) revealed the following: ethanol (0.23 g/L blood, 0.67 g/L urine), lormetazepam (1.65 microg/mL urine), cotinine (0.63 microg/mL blood, 5.08 microg/mL urine), caffeine (1.20 microg/mL urine), moclobemide (and metabolites), and citalopram (and metabolite). There upon, we developed a new liquid chromatographic separation with optimized DAD, preceded by an automated solid-phase extraction, for the quantitation of the previously mentioned antidepressive drugs. The results obtained for blood and urine, respectively, were as follows: Ro 12-5637 (moclobemide N'-oxide) not detected and 424 microg/mL; Ro 12-8095 (3-keto-moclobemide) 2.26 microg/mL and 49.7 microg/mL; moclobemide 5.62 microg/mL and 204 microg/mL; desmethylcitalopram 0.42 microg/mL and 1.22 microg/mL; and citalopram 4.47 microg/mL and 19.7 microg/mL. The cause of death was attributed to the synergistic toxicity of moclobemide and citalopram, both antidepressants, which, by intentional or accidental combined ingestion, can produce a potentially lethal hyperserotoninergic state. Based on the history of the case and pharmacology of the drugs involved, the forensic pathologists ruled that the cause of death was multiple drug intoxication, resulting in a fatal "serotonin syndrome," and that the manner of death was suicide.

Adult↗

Comparison of phenyl-type columns in the development of a fast liquid chromatographic system for eighteen opiates commonly found in forensic toxicology.

We report a precise and reliable method for the detection of 18 of the most commonly found opiates on the Belgian legal and illicit market, by ion-exchange, reversed-phase high-performance liquid chromatography, using a conventional phenyl-type analytical column (150x4.6 mm I.D., particle size 5 microm) and diode-array detection. We also describe a performance (efficiency and sensitivity) comparison of this column to a recently developed "high-speed" column (53x7.0 mm I.D., particle size 3 microm) packed with the same stationary phase, and used under slightly adjusted flow and gradient conditions. The final method, using the "high-speed" column, showed a significant reduction (55%) in analysis time without loss of resolution and sensitivity.

Buffers↗

Segmental analysis for cocaine and metabolites by HPLC in hair of suspected drug overdose cases.

Hair samples of eight postmortem cases were analyzed in segments of 1 to 3 cm for cocaine, benzoylecgonine and cocaethylene. Samples were prepared for analysis by digestion in 0.1 M HCl and subsequent extraction with mixed-mode solid-phase extraction columns. Measurement was made by reversed-phase, narrow-bore HPLC and fluorescence detection using two laboratory-made internal standards. The concentrations were in the region of 0.29-316 ng/mg of hair for cocaine, 0.43-141 ng/mg of hair for benzoylecgonine and 0.93-1.83 ng/mg of hair for cocaethylene. All eight investigated cases had cocaine-positive segments. In six of the cases, all segments were positive, suggesting regular cocaine use and two showed in-between negative segments indicating an interruption or a change of the abuse intensity. The results showed a second, remarkable observation, i.e. enormous concentration differences (factor >150) for both cocaine and benzoylecgonine between the different subjects. Furthermore, interindividual cocaine/benzoylecgonine ratios ranged from 0.02 to 8.43. We believe these observations could in part be attributed to both some of the still existing limitations in the analytical approach(es), especially the mandatory hair washing steps, and in our still too limited knowledge of the hair incorporation processes. Nevertheless, in some cases, segmental analysis proved to be an important tool to distinguish, together with postmortem examination, deadly chronic abuse from single acute drug overdosage.

Chromatography, High Pressure Liquid↗

Evaluation of automated single mass spectrometry to tandem mass spectrometry function switching for comprehensive drug profiling analysis using a quadrupole time-of-flight mass spectrometer.

A liquid chromatographic mass spectrometric strategy for systematic toxicological analysis (STA) is presented using the automatic 'on-the-fly' single mass spectrometry mode to tandem mass spectrometry mode (MS to MS/MS) switching abilities of a quadrupole time-of-flight (Q-TOF) instrument. During the chromatographic run, the quadrupole is initially set to transmit all masses until (an) ion(s) reaches a certain set threshold. Thereupon, the quadrupole automatically switches to the MS/MS mode, selecting the ion(s), which are subsequently fragmented in the high-efficiency hexapole collision cell, thus generating product ions that are further mass analyzed by the TOF. By limiting the TOF spectral accumulation time in the MS/MS mode to a statistically acceptable minimum, the quadrupole almost instantly switches back to the MS mode. Qualitative information, comprising the complementary MS ([M + H](+) ion mass) and MS/MS (informative product ion profile) data, as well as quantitative information obtained by integration of the MS extracted ion chromatogram(s), can be obtained in one single acquisition. Optimization of the automatic switching parameters, such as threshold, TOF spectral accumulation time, detection window and collision energy, was carried out by injection of a mix of 17 common drugs which were not necessarily baseline separated in the chromatographic system used. Indeed, the complete separation of the drugs is not deemed necessary since up to 8 different ions can 'simultaneously' be selected for MS/MS if they reach the preset criteria. In addition, the quantitative performance of the method was defined. In a second phase, the developed method was field-tested. To that end, the resulting data from extracts of urine samples were compared with and found to be in close concordance with those obtained by a standard toxicological analysis. This innovative approach clearly holds the potential for a substantial advance in the introduction of LC/MS in STA.

Autoanalysis↗

Is vitreous humour useful for the interpretation of 3,4-methylenedioxymethamphetamine (MDMA) blood levels? Experimental approach with rabbits.

As drug instability and redistribution are factors known to affect the interpretation of post-mortem blood levels, we questioned whether post-mortem vitreous humour concentrations could be useful as predictors for the MDMA load at the time of death. In a first series of in vivo experiments using rabbits, 3,4-methylenedioxymethamphetamine (MDMA) concentrations in plasma, blood and vitreous humour were studied as a function of time after intravenous (i.v.) administration of MDMA. Equilibration between the vascular compartment and vitreous humour was attained about 1 h after i.v. MDMA administration. In a second series of experiments, the post-mortem stability of MDMA in vitreous humour in relation to ambient temperature was investigated. Post-mortem MDMA concentrations in vitreous humour were closer to the ante-mortem blood levels when compared to cardiac blood samples. These preliminary investigations in the rabbit model indicate that measurements of vitreous humour concentrations could also be of interest for predicting the blood concentration at the time of death in humans.

Animals↗

Ethnicity in America and feeling "American".

Ethnic group acculturation remains a concern in the United States today. In the present study, the authors explored the extent to which members of three ethnic groups (White American women, African American women, and Cuban American women) perceived themselves to be "American," how much each group felt that its members were perceived as being American by White Americans, and how these perceptions related to beliefs about their own group's economic and social status. The results showed that African Americans felt American but felt that they were not perceived as such by White Americans. African Americans also reported feeling economically and socially excluded. In contrast, Cuban Americans reported neither feeling they were American nor believing they were perceived as such by White Americans, but feelings of inclusion increased with length of residence. Implications of these results for the common ingroup identity model are discussed.

Acculturation↗

A parental history of asthma is a risk factor for wheezing and nonwheezing respiratory illnesses in infants younger than 18 months of age.

The relationship between respiratory infection and allergy as risk factors for the development of wheezing illnesses in infants has been in dispute. We hypothesized that a parental history of allergic diseases would be associated with an increased rate of respiratory infections as well as an increased rate of wheezing during infectious episodes. We prospectively evaluated 1,193 infants from birth to 18 mo of age, using bi-weekly telephone surveillance to document all respiratory events. The overall rate of respiratory illness (all RI) increased to a maximum of 10.6 illnesses/infant/year in the 7- to 9-mo age group and then leveled off in the older infants. Multivariable models adjusting for demographic variables, breast feeding, month of illness, number of siblings, and attendance at day care showed an increase in the rate of all RI in infants older than 7 mo of age who had a parental history of asthma (OR = 1.24, CI = 1.09 to 1.41) or a parental history of atopy (OR = 1.14, CI = 1.03 to 1.26). The rate of lower respiratory illnesses accompanied by wheezing was related only to a parental history of asthma (OR = 2.06, CI = 1.36 to 3.11). We conclude that all RI, most of which represent viral infections, are increased in otherwise normal infants with a parental history of asthma or atopy, whereas wheezing is related only to a parental history of asthma.

Asthma↗

Medico-legal implications of hidden thyroid dysfunction: a study of two cases.

In this paper we present two cases in which thyroid disorders were unexpectedly brought to view. The question we ponder is whether hidden thyroid dysfunction may be important in the cause, mechanism and manner of death, or just an incidental discovery during the post-mortem examination. A short literature review has been conducted in order to evaluate previously reported cases of thyroid pathology and sudden death. The significance of post-mortem evaluation of thyroid hormones (T3 and T4) will be considered briefly.

Adult↗

Determination of the designer drugs 3, 4-methylenedioxymethamphetamine, 3,4-methylenedioxyethylamphetamine, and 3,4-methylenedioxyamphetamine with HPLC and fluorescence detection in whole blood, serum, vitreous humor, and urine.

BACKGROUND: The popular designer drugs 3, 4-methylenedioxymethamphetamine (MDMA) and 3, 4-methylenedioxyethylamphetamine (MDEA) can be determined in serum, whole blood, and urine, but also in vitreous humor. The latter matrix is interesting when dealing with decomposed bodies in a toxicological setting. METHODS: After extraction, chromatographic separation was achieved on a narrow-bore C(18) column by gradient elution with fluorometric detection; results were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). RESULTS: The method was linear over the range of 2-1000 microg/L for whole blood, serum, and vitreous humor, and 0.1-5 mg/L for urine. Extraction recoveries were >70%, imprecision (CV) was 2.5-19%, and analytical recoveries were 95.5-104.4%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.8 and 2 microg/L, respectively, for whole blood, serum, and vitreous humor, and 2.5 microg/L and 0.1 mg/L, respectively, for urine. Excellent correlations between the quantitative LC-fluorescence and LC-MS/MS results were obtained. We found the following concentrations in a thanatochemical distribution study in rabbits: in serum, 5.3-685 microg/L for MDMA and from the LOQ to 14.5 microg/L for 3, 4-methylenedioxyamphetamine (MDA); in whole blood, 19.7-710 microg/L for MDMA and from the LOQ to 17.8 microg/L for MDA; in vitreous humor, 12.1-97.8 microg/L for MDMA and from the LOQ to 3.86 microg/L for MDA. In routine toxicological urine samples, concentrations ranged from LOQ to 14.62 mg/L for MDA, from LOQ to 157 mg/L for MDMA, and from LOQ to 32.54 mg/L for MDEA. CONCLUSIONS: The HPLC method described is sensitive, specific, and suitable for the determination of MDMA, MDEA, and MDA in whole blood, serum, vitreous humor, and urine.

3,4-Methylenedioxyamphetamine↗

Identification and quantitation of despropionyl-bezitramide in postmortem samples by liquid chromatography coupled to electrospray ionization tandem mass spectrometry.

A sensitive and specific method for the determination and quantitation of (despropionyl) bezitramide in postmortem samples using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is presented. The method is the result from a simple methodological transfer of a liquid chromatographic method with fluorescence detection (LC-FL) previously developed in our laboratory. A liquid-liquid back-extraction procedure using n-hexane isoamyl alcohol (93:7, v/v) as the extraction solvent is performed for a basic sample cleanup. N-Methyldespropionyl bezitramide is used as the internal standard. Chromatographic separation of the analytes of interest is achieved on a Hypersil ODS 5-micron column, using a 80:20 (v/v) mixture of 1.0 mM ammonium acetate and methanol/acetonitrile (50:50, v/v) and 1.0 mM ammonium acetate as the mobile phase. To obtain as high a sensitivity and selectivity as possible, a selected reaction-monitoring mass spectrometric technique is applied. In addition, low-energy collisional-activated dissociation (CAD) product ion spectra are recorded for a few samples. Calibration graphs are prepared for blood and urine, and good linearity is achieved over a concentration range of 1-150 ng/mL. The intra- and interassay coefficients of variation (CV%) for the analysis of quality control samples at 10 and 50 ng/mL concentration levels do not exceed 10.2% and percent of targets are within 12.1%. Postmortem samples (blood, urine, stomach contents, bile, liver, and kidney) from three fatalities, all suspected victims of drug overdoses, are analyzed, and the results are reported. The results obtained with LC-ESI-MS/MS are in close agreement with those obtained using the LC-FL method. Moreover, the isolates' identity and structure are confirmed by the CAD product ion spectra, thus allowing to make unequivocal conclusions about the prior intake of bezitramide by the three subjects.

Benzimidazoles↗

Narrow-bore HPLC in combination with fluorescence and electrospray mass spectrometric detection for the analysis of cocaine and metabolites in human hair.

A simple, but sensitive and specific, high-performance liquid chromatographic assay for cocaine, cocaethylene, and benzoylecgonine is described. Using direct fluorometric detection, the procedure is particularly interesting for the routine analysis of human hair samples. In the sample preparation part, the hair samples are cut and washed and two internal standards with close structural resemblance to benzoylecgonine and cocaine as well as to cocaethylene are added. Subsequently, the hair samples are homogenized, hydrolyzed overnight in a 0.1 M HCl solution at 56 degrees C, and extracted on IST Confirm HCX solid-phase extraction columns. Chromatographic separation is achieved on a narrow-bore Hypersil BDS C18 column (125 x 2.1 mm, 3 microns) by gradient elution with an ammonium acetate buffer-methanol/acetonitrile mixture. For the fluorometric detection, excitation and emission wavelengths of 242 and 315 nm, respectively, are used. This analysis protocol affords a method of high sensitivity and specificity which has been fully evaluated and validated. The data presented show good accuracy and linearity with excellent reproducibility and recovery. Because unequivocal identity confirmation is mandatory in forensic applications, an extension of the analysis protocol was accomplished toward mass spectrometric detection. We succeeded in a simple methodological transfer from LC/FL to LC/ESI-MS/MS, thus providing two complementary approaches after a single, common sample-processing step. Hair samples from 29 fatalities, all known drug users and suspected victims from a drug overdose, were analyzed in this way. Of the investigated samples, 12 were positive and the concentrations found range from 0.98 to 938 ng/mg of hair for cocaine and from 1.45 to 388 ng/mg of hair for benzoylecgonine. Traces of cocaethylene were also found in two of the hair samples. The results obtained with LC/ESI-MS/MS were in close agreement with those obtained with LC/FL, positively confirming the isolates' identity and structure by means of the resulting MS/MS spectra.

Chromatography, High Pressure Liquid↗

Breastfeeding reduces risk of respiratory illness in infants.

Breastfeeding has long been believed to protect against infection in infants, but protection against respiratory illnesses has not been consistently demonstrated in studies in developed countries. Between 1988 and 1992, the authors assessed the effect of breastfeeding on incidence and duration of respiratory illnesses during the first 6 months of life in a prospective study that actively tracked breastfeeding and respiratory illnesses. A cohort of 1,202 healthy infants, born in Albuquerque, New Mexico, between January 1, 1988 and June 30, 1990, from homes without smokers was enrolled. The daily occurrences of respiratory symptoms and breastfeeding status were reported by the mothers every 2 weeks. Illnesses were classified as lower respiratory illness (LRI) if wheezing or wet cough was reported; the remaining illnesses were classified as upper respiratory. The annualized incidence rates for LRI were 2.8, 2.6, and 2.1 during follow-up time with no, partial, or full breastfeeding, respectively, but the incidence rates for upper respiratory illness and lower respiratory illness combined were similar in the three categories. After adjustment for potential confounding factors, full breastfeeding was associated with a reduction in lower respiratory illness risk (odds ratio=0.81, 95% confidence interval 0.68-0.96). Median duration of all respiratory illnesses was 5 days for the fully breastfed infants during the first 6 months of life compared with a median of 6 days for not breastfed and partially breastfed infants. Multivariate analysis confirmed that breastfeeding significantly reduced the duration of respiratory illness. This pattern of reduced incidence of LRI and shorter duration of all respiratory illnesses suggests that breastfeeding reduces the severity of infant respiratory illnesses during the first 6 months of life.

Adolescent↗

Quantitative analysis of despropionyl-bezitramide, the active metabolite of bezitramide (Burgodin), in biological samples by high-performance liquid chromatography with fluorescence detection.

A sensitive high-performance liquid chromatographic procedure with fluorescence detection was developed for the quantitative determination of despropionyl-bezitramide, the active metabolite of bezitramide (Burgodin), in biological samples. Chromatographic separation was achieved on a Hypersil ODS (C18) 5-micron column, using a 31:69 (v/v) mixture of 0.1 M ammonium acetate and methanol/acetonitrile (50:50, v/v)-0.1 M ammonium acetate as the eluent. Internal standardization with N-methyldespropionyl-bezitramide was used in order to enhance the precision and the accuracy of the method. For the isolation of the compound from biological samples, a liquid-liquid extraction with n-hexane-isoamyl alcohol (93:7 v/v) was performed. Calibration graphs were prepared for blood and urine, and linearity was achieved over a concentration range 1-50 ng/mL. The quantitation limit for despropionyl-bezitramide in blood and urine was 1 ng/mL. At a 10 ng/mL concentration in blood, coefficients of variation of 3.3 and 6.5% were obtained for within-day and between-day precisions, respectively. For urine, the respective coefficient of variation values of 4.3 and 4.9% were obtained. The selectivity and the accuracy of the method were satisfactory. Samples (blood, urine, stomach contents, bile, liver, kidney) from five fatalities that were due to the combined intake of several drugs, including bezitramide, were analyzed and the results are reported. In addition, one blood sample and 14 urine samples from persons suspected of using bezitramide were analyzed, revealing despropionyl-bezitramide concentrations in urine ranging from 1.3 to 72.3 ng/mL.

Benzimidazoles↗

Potential of high-performance liquid chromatography with photodiode array detection in forensic toxicology.

The potentials and limitations of high-performance liquid chromatography-photodiode array detection are highlighted in respect to its use in the analysis of different biological matrices followed by the identification of unknowns. The logical analytical approach used in clinical and forensic toxicology, vital for the identification of one or more toxic substances as a cause of intoxication, is largely based on both simple and fast "general unknown screening" methods which cover most relevant drugs and potentially hazardous chemicals. In this field of systematic toxicological analysis, a literature overview shows that HPLC can play a substantial role. Both column packing material and eluent composition have their impact on intra- and interlaboratory reproducibility. In view of the sometimes different retention characteristics of various HPLC columns, several possibilities are addressed to enhance the discriminating power of primary retention parameters. The advantages of photodiode array detection as compared to UV detection have been of paramount importance to the success of HPLC in toxicological analysis. Dedicated libraries with spectral information and searching software are powerful tools in the process of identification of an unknown substance. In the present paper, these aspects are also verified in a number of real cases, i.e., trazodone and dothiepin, azide, chloroquine and cocaine, in which we illustrate from our own experience the potentials of HPLC-photodiode array detection in systematic toxicological analysis.

Adult↗

Liquid chromatographic determination of cocaine, benzoylecgonine, and cocaethylene in whole blood and serum samples with diode-array detection.

An extraction with Bond Elut Certify solid-phase extraction (SPE) columns is developed for the isolation of cocaine, benzoylecgonine, and cocaethylene from whole blood and serum followed by reversed-phase liquid chromatography with diode-array detection. Two internal standards (2'-methylbenzoylecgonine and 2'-methylcocaine) with close structural resemblance to benzoylecgonine (a carboxylic acid) and to the two esters, cocaine and cocaethylene, are used in the analytical procedure. A thorough evaluation of this SPE and a comparison with different liquid-liquid extractions clearly show the superiority of the SPE. A linear response (correlation coefficient greater than 0.998) over a broad concentration range (0.025-5.0 micrograms/mL) is obtained. The sensitivity, specificity, precision (coefficients of variation less than 4.9% for within-day reproducibility and less than 5.3% for total reproducibility), and accuracy of the method are excellent for each analyte. Forensic blood samples from people suspected of cocaine abuse are analyzed and show the usefulness of the method, even for degraded postmortem samples.

Chromatography, Liquid↗