Search PubMed⌕ Search

Biomedical subjects

W C Hayes

Publications and source records attributed to W C Hayes.

At least 73 records · Page 4Linked to original sources

Predicting pathologic fracture risk in the management of metastatic bone defects.

Guidelines for the prediction of pathologic fracture would facilitate the management of patients with metastatic bone defects. Unfortunately, existing clinical guidelines have not been validated, often run counter to engineering practice, and do not accurately predict the risk of fracture for many patients. To serve as a basis for improved guidelines, a factor of risk for a pathologic fracture is defined as the load applied to a bone divided by the load at which the bone fails. Failure loads for bones with metastatic defects have been measured in vitro, and depend on defect geometry, bone properties, and the type of loading. For a diaphyseal defect that destroys 50% of the cortex, strength reductions of between 60% and 90% can occur. The load-bearing capacity of a long bone with a diaphyseal defect also can be predicted using computer models if the geometry of the defect and properties of surrounding bone are known. Similarly, new methods that apply basic engineering principles to computed tomography data allow prediction of the load-bearing capacity of vertebrae with simulated defects. By contrast, the data presented here suggest that by using plane radiographs or computed tomographic (CT) examinations, experienced orthopaedic surgeons cannot accurately estimate the strength reductions or load-bearing capacity for proximal femurs with intertrochanteric defects. By combining new methods to predict the load-bearing capacity with estimated loads for activities of daily living, it is possible to calculate a factor of risk for pathologic fractures.

Biomechanical Phenomena↗

Fall severity and bone mineral density as risk factors for hip fracture in ambulatory elderly.

OBJECTIVE: To determine the relative importance of fall characteristics, body habitus, and femoral bone mineral density (BMD) in predicting hip fracture in community-dwelling elderly. DESIGN: Prospective case-control study. SETTING: Community-based academic hospital. PARTICIPANTS: A total of 149 ambulatory, community-dwelling fallers (126 women, 23 men) aged 65 years and older, including 72 case patients (fallers with hip fracture) and 77 control fallers (fallers with no hip fracture). MAIN OUTCOME MEASURES: Fall characteristics, body habitus, femoral BMD. RESULTS: Significant and independent risk factors for hip fracture in both sexes were direction of the fall (adjusted odds ratio [OR], 5.7; 95% confidence interval [CI], 2.3 to 14.0; P < .001); femoral neck BMD (a decrease of 1 SD; adjusted OR, 2.7; 95% CI, 1.6 to 4.6; P < .001); potential energy of the fall (an increase of 1 SD; adjusted OR, 2.8; 95% CI, 1.5 to 5.2; P < .001); and body mass index (a decrease of 1 SD; adjusted OR, 2.2; 95% CI, 1.2 to 3.8; P < .01). Importantly, the OR for the fall direction was unaffected by the addition or removal of BMD from the model. CONCLUSIONS: We conclude that among elderly fallers--in most of whom hip BMD is already less than the fracture threshold--fall characteristics and body habitus are important risk factors for hip fracture and touch on a domain entirely missed by knowledge of BMD. These data suggest new targets for preventive therapy. In addition to the maintenance of bone density, reductions in fall severity (eg, by use of trochanteric padding or enhancement of muscle strength) may provide additional strategies for prevention of hip fracture in this age group.

Accidental Falls↗

Healing of large segmental defects in rat femurs is aided by RhBMP-2 in PLGA matrix.

Recombinant human bone morphogenetic protein-2 (rhBMP-2) can be used to enhance the repair of congenital or acquired bone pathologies when formulated in the appropriate carrier. Poly [D,L-(lactide-co-glycolide)] (PLGA) has been shown to be an effective carrier of rhBMP-2. We investigated several particle sizes PLGA and several doses of rhBMP-2 in a rat orthotopic model. We also investigated the effects of a fibrinolytic inhibitory agent, epsilon aminocaproic acid (EACA), on the healing response. Our data indicate that higher doses of rhBMP-2 resulted in increased failure torque (408 +/- 70 N-mm or 60% of the intact value) and higher incidence of union (100%). The induced bone in femurs treated with the smaller particle size PLGA achieved the greatest torsional stiffness and strength. The presence of rhBMP-2 was necessary for new bone to form, but the presence of EACA did not change these results; the use of the PLGA carrier appeared to increase bone strength and stiffness. In fact, with higher doses of rhBMP-2 in PLGA, the stiffness of the new bone was equal to that of intact controls (64 +/- 20 N-mm/deg [intact femurs] versus 45 +/- 10 N-mm/degree [medium dose in small PLGA], 61 +/- 17 N-mm/degree [high dose in small PLGA], and 36 +/- 11 N-mm/degree [medium dose in large PLGA]; P > .05). In conclusion, PLGA implanted with rhBMP-2 effectively aided in healing large segmental defects in rat femurs.

Animals↗

Trochanteric bone mineral density is associated with type of hip fracture in the elderly.

Hip fractures can be separated into femoral neck (cervical or intracapsular) or trochanteric (extracapsular). Trochanteric fractures have been associated with up to twice the short-term mortality of cervical fractures in the elderly. Fracture type may be influenced by the fall direction and local differences in proximal femur strength properties. We previously demonstrated that fall characteristics and body habitus, in addition to femoral bone mineral density, play a dominant role in the prediction of hip fracture in elderly fallers. To examine the association of these determinants with hip fracture type, we assessed fall characteristics, body habitus, and site-specific bone mineral density measurements in 112 elderly hip fracture patients (85 women and 27 men, mean age 85 years) 1 week after an acute hip fracture. Trochanteric BMD was 13% lower in women and 11% lower in men for patients with trochanteric fracture than in those with femoral neck fracture (p < 0.01). A stepwise multiple logistic regression indicated that trochanteric BMD (decrease of 1.0 SD, adjusted OR 4.6, 95% Cl 2.0-9.5, p < 0.0001) and femoral neck BMD (increase of 1.0 SD, adjusted OR 3.0, 95% Cl 1.6-5.9, p = 0.0003) were independently associated with trochanteric fracture. Fall characteristics, body habitus, gender, and age were not associated with hip fracture type. We conclude that a relatively low trochanteric BMD or a high femoral neck BMD was associated with a trochanteric hip fracture and that site-specific trochanteric BMD determinations should be measured when assessing risk of trochanteric hip fractures in the elderly.

Accidental Falls↗

Effects of loading rate on strength of the proximal femur.

Results from previous quasi-static mechanical tests indicate that femurs from elderly subjects fail in vitro at forces 50% below those available in a fall from standing height. However, bone is a rate-dependent material, and it is not known whether this imbalance is present at rates of loading which occur in a fall. Based on recent data on time to peak force and body positions at impact during simulated falls, we designed a high rate test of the femur in a loading configuration meant to represent a fall on the hip. We used elderly (mean age 73.5 +/- 7.4 (SD) years) and younger adult (32.7 +/- 12.8 years) cadaveric femurs to investigate whether (1) the strength, stiffness, and energy absorption capacity of the femur increases under high rate loading conditions; (2) elderly femurs have reduced strength, stiffness, and energy absorption capacity compared with younger adult femurs at this loading rate; and (3) densitometric and geometric measures taken at the hip correlate with the measured fracture loads. Femurs were scanned using dual-energy X-ray absorptiometry (DXA) and then tested to failure in a fall loading configuration at a displacement rate of 100 mm/second. The fracture load in elderly and younger adult femurs increased by about 20% with a 50-fold increase in displacement rate. However, energy absorption did not increase with displacement rate because of a twofold increase in stiffness at the higher loading rate.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

A method for measuring the structural properties of the rat mandible.

The rat mandible has been used to study fractures, ridge augmentation, bone defects, and the effects of cryosurgery, all of which affect the structural properties of the mandible. The only previously described mechanical test of the rat mandible used three-point bending with a piece of foam placed between the lingual surface of the mandible and the support. The accuracy and reproducibility of this test were not determined. Two different, three-point bending tests for characterizing the structural properties of the rat mandible have now been evaluated. Acrylic specimens representing three different-sized mandibles were tested in three-point bending with either potted ends or foam interposed between the specimen and the outer load points. Flexural stiffness and failure load were compared against data from a conventional three-point bending test. In addition, five paired halves of 90- and 210-day-old rat mandibles were tested either with interposed foam or with potted ends and the mean coefficients of variation of the stiffness and failure loads were determined. Failure loads of the acrylic specimens with the potted and foam methods were significantly higher (50 and 10%, respectively; p < 0.05) than with the conventional method. The stiffness of the acrylic specimens with the potted and foam methods was significantly different (75% higher and 21% lower, respectively; p < 0.05) than with the conventional test. In addition, there was no difference between the coefficient of variation in stiffness (26 + 11%) or failure load (10 + 4%) measured with the foam test and the comparable values (16 + 11%) and (18 + 13%) in the potted test.(ABSTRACT TRUNCATED AT 250 WORDS)

Acrylic Resins↗

Compressive creep behavior of bovine trabecular bone.

There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxial compressive creep tests on 24 cylindrical specimens of trabecular bone taken from 19 bovine proximal tibiae. Six different load levels were used, with the applied stress normalized by the specimen modulus measured prior to creep loading. We found that trabecular bone exhibits the three creep regimens (primary, secondary, and tertiary) associated with metals, ceramics, and cortical bone. All specimens eventually fractured at strains less than 3.8%. In addition, the general shape of the creep curve was independent of apparent density. Strong and highly significant power law relationships (r2 > 0.82, p < 0.001) were found between the normalized stress sigma/E0 and both time-to-failure tf and steady-state creep rate d epsilon/dt: tf = 9.66 x 10(-33) (sigma/E0)-16.18; d epsilon/dt = 2.21 x 10(33) (sigma/E0)17.65. These data indicate that the creep behaviors of trabecular and cortical bone are qualitatively similar. In addition, the strength of trabecular bone can be reduced substantially if relatively large stresses (i.e. stresses approximately half the ultimate strength) are applied for 5 h. Such strength reductions may play a role in the etiology of progressive, age-related spine fractures if adaptive bone remodeling does not arrest creep deformations.

Aging↗

Mechanical behavior of damaged trabecular bone.

The mechanical behavior of damaged trabecular bone may play a role in the etiology of age-related spine fractures since damaged bone exists in and may weaken the elderly vertebral body. To describe some characteristics of damaged trabecular bone, we measured the changes in modulus and strength that occur when bovine trabecular bone is loaded in compression to various strains beyond its elastic range. Twenty-three reduced-section specimens, taken from 17 different bones, were loaded from 0-X-0-9% strain, where X was one of four strains: 1.0% (n = 7), 2.5% (n = 6), 4.0% (n = 5), or 5.5% (n = 5). We found that modulus was reduced for all applied strains, whereas strength was reduced only for strain levels > or = 2.5%; the percentage changes in modulus and strength were independent of Young's modulus but were highly dependent on the magnitude of the applied strains; modulus was always reduced more than strength; and simple statistical models, using knowledge of only the applied strains, predicted well the percentage reductions in modulus (r2 = 0.97) and strength (r2 = 0.74). The modulus reductions reported here are in qualitative agreement with those for cortical bone in tensile loading, supporting the concept that the damage behaviors of cortical and trabecular bone are similar for low strains (< or = 4.0%). In addition, because modulus was always reduced more than strength, damaged trabecular bone may be stress protected in vivo by redistribution of stresses to undamaged bone.

Algorithms↗

Trabecular bone exhibits fully linear elastic behavior and yields at low strains.

Using a protocol designed to reduce experimental artifacts associated with the conventional compression test for trabecular bone, we performed in vitro mechanical testing on bovine tibial trabecular bone to obtain accurate descriptions of the elastic and yield behaviors. Reduced-section cylindrical specimens were preconditioned for eight tension-compression (+/- 0.5% strain) cycles and then loaded to failure either in tension (n = 15) or compression (n = 14). We found that the pre-yield behavior for every specimen was fully linear, indicating that the initial nonlinear 'toe' is an experimental artifact. Analysis of variance on the moduli indicated that there was no significant difference between the tensile and compressive moduli before preconditioning. However, preconditioning decreased the tensile and compressive moduli on average by 8.8% (p < 0.01) and 5.3% (p < 0.01), respectively, with the decrease in tensile modulus being larger (p < 0.01). These small but significant decreases in modulus suggest that initial yielding involves microstructural damage (as opposed to plastic slip) of individual trabeculae and also indicate that the tensile and/or the compressive yield strain of (bovine tibial) trabecular bone is less than 0.5%. The mean tensile strength was approximately 70% of the mean compressive strength, although this difference in strengths may have been affected by the preconditioning-induced damage. Taken together, these results suggest that there are more similarities between the elastic and yield behaviors of trabecular and cortical bone than had been assumed previously.

Analysis of Variance↗

Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus.

The conflicting conclusions regarding the relationship between the tensile and compressive strengths of trabecular bone remain unexplained. To help resolve this issue, we compared measurements of the tensile (n = 22) and compressive (n = 22) yield strengths, and yield strains, of trabecular bone specimens taken from 38 bovine proximal tibiae. We also studied how these failure properties depended on modulus and apparent density. To enhance accuracy, trabecular orientation was controlled, and each specimen had a reduced section where strains were measured with a miniature extensometer. We found that the mean yield strength was 30% lower for tensile loading. However, the difference between individual values of the tensile and compressive strengths increased linearly with increasing modulus and density, being negligible for low moduli, but substantial for high moduli. By contrast, both the tensile and compressive yield strains were independent of modulus and density, with the yield strain being 30% lower for tensile loading. Thus, the difference between the tensile and compressive strengths of bovine tibial trabecular bone depends on the modulus, but the difference between yield strains does not. This phenomenon may explain in part that conflicting conclusions reached previously on the tensile and compressive strengths of trabecular bone since the mean modulus has varied among different studies. Realizing that our data pertain only directly to bovine tibial trabecular bone for longitudinal loading, our results nevertheless suggest that failure parameters based on strains may provide more powerful and general comparisons of the failure properties for trabecular bone than measures based on stress.

Animals↗

Finite element modeling of damage accumulation in trabecular bone under cyclic loading.

A two-dimensional finite element model of an idealized trabecular bone specimen was developed to study trabecular bone damage accumulation during cyclic compressive loading. The specimen was modeled as a two-dimensional honeycomb-like structure made up of an array of hexagonal cells. Each trabecula was modeled as a linearly elastic beam element with the same material properties as cortical bone. Initial microcracks were assumed to exist within the oblique trabeculae and to grow according to the Paris law. Forces and moments were computed in each trabecula and the microcracks were allowed to propagate until fracture occurred. Between cycles, fractured trabeculae were removed from the finite element mesh, and force and moment distributions were calculated for the next cycle. This iterative process was continued until the simulated trabecular bone specimen showed a 10% reduction in modulus. Creep failure was also studied using a single cell analysis, in which a closed-form solution was obtained after prescribing the creep properties of the trabeculae. The results of the crack propagation analysis showed that fractures of only a small number of individual trabeculae can cause a substantial reduction in the modulus of the trabecular bone specimen model. Statistical tests were performed to compare the slopes and intercepts of the S-N curves of our model predictions to those of experimentally derived S-N curves for bovine trabecular bone. There was no significant difference (p > 0.2 for both slope and intercept) between our model predictions and the experimentally derived S-N curves for the low-stress, high-cycle range. For the high-stress, low-cycle range, the crack propagation model overestimated the fatigue life for a given stress level (for slope, p < 0.001), while the creep analysis agreed well with the experimental data (for slope, p > 0.2). These findings suggest that the primary failure mechanism for low-stress, high-cycle fatigue of trabecular bone is crack growth and propagation, while the primary failure mechanism for high-stress, low-cycle fatigue is creep deformation and fracture. Furthermore, our results suggest that the modulus of trabecular bone at the specimen level may be highly sensitive to fractures of individual trabeculae.

Algorithms↗

Morphology-mechanical property relations in trabecular bone of the osteoarthritic proximal tibia.

Alteration of morphologic and mechanical properties of trabecular bone in the osteoarthritic proximal tibia may be a contributing factor in tibial component loosening. To explore this issue, the authors performed tissue property measurements, morphologic analysis, and mechanical testing of subchondral, epiphyseal, and metaphyseal trabecular bone specimens retrieved from six human proximal tibias exhibiting a range of medial unicondylar osteoarthritic degeneration. Apparent density in the proximal tibia was altered according to varus misalignment and medial subluxation associated with medial osteoarthritis of the knee. In subchondral bone, a decrease in tissue mineralization contributed to a significant reduction in axial mechanical properties with degenerative disease (P < .0005). In epiphyseal and metaphyseal bone, trabecular thickness and the number of trabeculae increased linearly with volume fraction, providing a power law relationship between axial elastic modulus and apparent density (R2 = .84). Average elastic properties of the tibial epiphysis and metaphysis were not reduced by degenerative disease (P < .05). The results suggest that absolute minimization of tibial resection might not be an optimal strategy for tibial component fixation and that mechanical properties of the tibial resection surface are more homogeneous in planes parallel to the joint surface than in a plane normal to the longitudinal axis of the tibia.

Aged↗

Maxillary molar extraction decreases stiffness of the mandible in ovariectomized rats.

Although osteoporosis is a major public health concern, the effect of this condition on oral bone has not been determined. Using the ovariectomized rat as a model, we examined whether acute estrogen depletion affects the mandible of the ovariectomized rat with and without maxillary molar extraction. Twenty-two ovariectomized and 20 sham-ovariectomized 90-day-old Sprague-Dawley rats were divided into the following groups: (1) sham-ovariectomized, baseline control; (2) ovariectomized, baseline control; (3) ovariectomized; (4) ovariectomized, tooth extraction; (5) sham-ovariectomized; and (6) sham-ovariectomized, tooth extraction. On day eight, sham-ovariectomized and ovariectomized rats had all their maxillary molars extracted, and the baseline control sham-ovariectomized and ovariectomized rats were killed. On day 35, the remaining animals were killed. After teeth were harvested, the right mandible was tested to failure in three-point bending. The bone mineral density of the left mandible was measured with dual-energy x-ray absorptiometry. The area fraction and area moment of inertia of a section of mandible were determined. Neither ovariectomy nor tooth extraction significantly affected the bone mineral density or structural properties of the rat mandible. However, there was an interaction between ovariectomy and maxillary molar extraction on the stiffness of the rat mandible (p < 0.008). Maxillary molar extraction decreased the stiffness of the mandible by 25% (p < 0.05) in the ovariectomized rat, whereas it did not do so in the sham-ovariectomized rat.

Alveolar Bone Loss↗

A comparison of the effects of automated percutaneous diskectomy and conventional diskectomy on intradiscal pressure, disk geometry, and stiffness.

Diskectomy, chemonucleolysis, percutaneous diskectomy, and laser ablation are used to treat patients with sciatica. The effects of percutaneous diskectomy on the intradiscal pressure of the human disk are not known. Our aims were to determine (a) whether removal of nucleus through automated percutaneous diskectomy significantly reduces intradiscal pressure without altering the disk geometry and stiffness, and if so, how much nucleus removal is required to achieve these goals; and (b) whether the effects of conventional diskectomy on these same parameters are equivalent to removal of nucleus through automated percutaneous diskectomy. Cyclic compressive loads of 20-900 N were applied to lumbar disks. Conventional diskectomy or automated percutaneous diskectomy (performed for 40 min with biomechanical measurements made four times at 10-min intervals) was then performed under zero load and the specimens retested under the same cyclic compressive loading. There were significant (p < 0.01) decreases in intradiscal pressure (by 7% under 900 N) after 10 min of automated percutaneous lumbar diskectomy. There were no further significant decreases in pressure during the next 30 min of percutaneous diskectomy. There were also significant decreases in pressure due to a puncture hole made with the Nucleotome trephine alone, without removal of disk material, and there was no difference in pressure after trephining alone and after percutaneous diskectomy. Decreases in disk height were significant, ranging from 5% at 10 min to 7% at 40 min of treatment. There were equivalent decreases in intradiscal pressure and disk height due to removal of similar amounts of nucleus during conventional diskectomy and during 40 min of percutaneous diskectomy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Finite-element stress analysis of the normal and osteoporotic lumbar vertebral body.

A finite-element model of an isolated elderly human L3 vertebral body was developed to study how material properties and loading conditions influence end-plate and cortical-shell displacements and stresses. The model consisted of an idealized geometric representation of an isolated vertebral body, with a 1-mm-thick end plate and cortical shell. For uniform compression, large tensile stresses occurred all around the cortical shell just below the end plate as a result of bending of the cortical shell as it supported the end plate. Large tensile bending stresses also developed in the inferior surface of the end plate. Equal reductions in both trabecular and cortical bone moduli increased displacements but did not affect peak stresses. A 50% reduction in trabecular bone modulus alone increased peak stresses in the end plate by 74%. Elimination of the cortical shell reduced peak stresses in the end plate by approximately 20%. For nonuniform, anteriorly eccentric compression, peak stresses everywhere changed by less than 11% but moved to the anterior aspect. When material properties were adjusted to represent osteoporosis with disproportionate reductions in trabecular (50% decrease) and cortical (25% decrease) bone moduli, anterior compression increased peak stresses by up to 250% compared to uniform compression. If fractures are initiated in regions of large tensile stresses, the results from this relatively simple model may explain how central end-plate and transverse fractures initiate from uniform compression of the end plate. Furthermore, for anterior compression, disproportionate modulus reductions in trabecular and cortical bone may substantially increase end plate and cortical shell stresses, suggesting a cause of age-related spine fractures.

Aged↗

Effects of combined prostaglandin and alendronate treatment on the histomorphometry and biomechanical properties of bone in ovariectomized rats.

Prostaglandin E2 (PGE2) has been shown to stimulate both bone resorption and formation in experimental animals, leading to augmentation of trabecular and cortical bone. The amino bisphosphonate alendronate (ALN) is a potent inhibitor of bone resorption. The objectives of this study were to examine if PGE2 stimulation of bone formation was dependent on bone resorption and if the bone accrued as a result of PGE2 treatment contributed to bone strength. The 48 female Sprague-Dawley rats were assigned to six groups as follows: five groups (8/group) were ovariectomized at the age of 6 months. One group was sacrificed 2 months later to establish baseline conditions, and four groups were treated for 25 days with (1) vehicle, (2) PGE2 at 3 mg/kg/day, (3) ALN sc at 0.8 micrograms/kg/day, and (4) PGE2 + ALN at the respective doses. The sixth group served as nonovariectomized untreated controls. Histomorphometric analysis of 6-10 microns thick tibial sections after in vivo fluorochrome double labeling showed that treatment with PGE2 alone increased endocortical mineral apposition rate and bone formation rate, stimulated production of bone trabeculae in the marrow cavity, and increased cortical porosity. Combined ALN + PGE2 treatment prevented the resorption induced by PGE2 but not the stimulation of bone formation on endocortical and periosteal surfaces and resulted in a significant increase in cortical thickness. Consistent with these observations, the femoral midshaft tested to failure in three-point bending showed a significant increase in strength in the PGE2 + ALN group (181 +/- 15 N) compared to time 0 controls (145 +/- 23 N) or to the ovariectomized vehicle-treated group (141 +/- 28 N).(ABSTRACT TRUNCATED AT 250 WORDS)

Alendronate↗

Antibiotic-loaded biodegradable bone cement for prophylaxis and treatment of experimental osteomyelitis in rats.

A biodegradable, particulate composite bone cement containing gentamicin and vancomycin was used for both treatment and prophylaxis of Staphylococcus aureus osteomyelitis in rats. Osteomyelitis was established by inoculating S. aureus into holes that were drilled in the proximal tibiae and were filled with polymethylmethacrylate (PMMA) cylinders. The cylinders were left in place for 3 weeks. The infections were serially evaluated by clinical and radiographic examination and by quantitative culture for colony forming units (CFUs) at the time the rats were killed. For treatment, cements containing antibiotic were implanted in animals that had established osteomyelitis and were left in place for an additional 3 weeks. Sites treated with biodegradable cement containing antibiotics exhibited significantly fewer CFUs in comparison with controls (p < 0.01). Sites treated prophylactically with the biodegradable cement developed no infections as evaluated by clinical or radiographic criteria or by quantitative culture. At this relatively early time, no significant difference in therapeutic effectiveness was found when either the biodegradable cement or PMMA was used as a carrier for antibiotics.

Animals↗

Impact near the hip dominates fracture risk in elderly nursing home residents who fall.

Hip fractures among the elderly are a significant and rapidly growing public health problem. The prevailing view is that most hip fractures are the consequence of age-related bone loss or osteoporosis. However, because over 90% of hip fractures are the result of falls, we have undertaken a falls surveillance study to determine if factors related to the mechanics of falling are associated with increased risk of hip fracture. Case subjects with hip fracture and control subjects without hip fracture were sampled from falls recorded at the Hebrew Rehabilitation Center for Aged, a chronic care facility. Fall information was obtained by interview of the subject and witnesses if the fall was witnessed. Data were analyzed by multiple logistic regression. Increased risk of hip fracture from a fall was associated with impacting on the hip or side of the leg and potential energy associated with the fall. Quetelet, or body mass index, was inversely related to fracture risk. The adjusted odds ratio of hip fracture for a fall involving impact on the hip region was 21.7 (95% confidence interval, 8.2-58). The potential energy associated with these falls was an order of magnitude greater than the average energy required to fracture elderly, cadaveric, proximal femurs in earlier in vitro experiments. We conclude, therefore, that a fall from standing height should no longer be considered minimal trauma but rather trauma of sufficient magnitude to pose a high risk of hip fracture if impact occurs on the hip and if energy-absorbing processes are inadequate.(ABSTRACT TRUNCATED AT 250 WORDS)

Accidental Falls↗