In vitro degradation of a poly(propylene fumarate)-based composite material.

We investigated the in vitro degradation of a novel degradable polymeric composite material being developed to function as a temporary replacement for trabecular bone. This material is based on a mixture of poly(propylene fumarate) cross-linked by N-vinyl-pyrrolidone and includes sodium chloride and beta-tricalcium phosphate. Using an in vitro test in simulated body fluids, the compressive strengths and compressive moduli of two composite materials increased with degradation time and remained above the minimum values acceptable for trabecular bone substitutes. A compressive strength of 21.3 (+/- 0.4) MPa and a compressive modulus of 696 (+/- 53) MPa were measured after twelve weeks for a composite material with initial strength of 18.0 (+/- 4.6) MPa and initial modulus of 113 (+/- 40) MPa. This unexpected phenomenon may prove to be useful for orthopaedic applications.

Biocompatible Materials↗

Evolution of bone transplantation: molecular, cellular and tissue strategies to engineer human bone.

Bone defects occur in a wide variety of clinical situations, and their reconstruction to provide mechanical integrity to the skeleton is a necessary step in the patient's rehabilitation. The current gold standard for bone reconstruction, the autogenous bone graft, works well in many circumstances. However, autograft reconstruction, along with the available alternatives of allogenous bone graft or poly(methylmethacrylate) bone cement, do not solve all instances of bone deficiency. Novel materials, cellular transplantation and bioactive molecule delivery are being explored alone and in various combinations to address the problem of bone deficiency. The goal of these strategies is to exploit the body's natural ability to repair injured bone with new bone tissue, and to then remodel that new bone in response to the local stresses it experiences. In general, the strategies discussed in this paper attempt to provide the reconstructed region with appropriate initial mechanical properties, encourage new bone to form in the region, and then gradually degrade to allow the new bone to remodel and assume the mechanical support function. Several of the concepts presented below are already finding clinical applications in early patient trials.

Biocompatible Materials↗

Etiology and prevention of age-related hip fractures.

Falls and fall-related injuries are among the most serious and common medical problems experienced by the elderly. Hip fracture, one of the most severe consequences of falling in the elderly, occurs in only about 1% of falls. Despite this, hip fracture accounts for a large share of the disability, death, and medical costs associated with falls. As measured by their frequency, influence on quality of life, and economic cost, hip fractures are a public health problem of crisis proportions. Without successful international initiatives aimed at reducing the incidence of falls and hip fractures, the implications for allocations of health resources in this and the next century are staggering. Identifying those at risk for harmful falls requires an understanding of what kinds of falls result in injury and fracture. In elderly persons who fall, in most of whom hip bone mineral density is already several standard deviations below peak values, fall severity (as reflected in falling to the side and impacting the hip) and body habitus are important risk factors for hip fracture and touch on a domain of risk entirely missed by knowledge of bone mineral density. These findings clearly suggest that factors related to both loading and bone fragility play important roles in the etiology of hip fracture. We provide a strategy, based on engineering approaches to fracture risk prediction, for determining the relative etiologic importance of loading and bone fragility and to summarize some of what is known about both sets of factors. We define a factor of risk, phi, as the ratio of the loads applied to the hip divided by the loads necessary to cause fracture and summarize available data on the numerator and the denominator of phi. We then provide an overview of the complex interplay between the risks associated with the initiation, descent, and impact phases of a fall, thereby suggesting an organized approach for evaluating intervention efforts being used to prevent hip fractures. The findings emphasize the continuing need for combined intervention strategies that focus on fall prevention, reductions in fall severity, and maintaining or increasing femoral bone mass and strength, either through targeted exercise programs, optimal nutrition (Ca, Vitamin D), and/or in the use of osteodynamic agents. By developing and refining the factor of risk, a property that captures both the contributions of bone density and the confounding influences of body habitus and fall severity, we believe these intervention strategies can be targeted more appropriately.

Accidental Falls↗

Long-term safety of the aminobisphosphonate alendronate in adult dogs. I. General safety and biomechanical properties of bone.

Alendronate (4-amino-1-hydroxybutylidene bisphosphonate, ALN) is an aminobisphosphonate that is being developed for the treatment of diseases characterized by increased bone resorption. The purpose of this study was to assess the long-term safety of ALN with special emphasis on bone strength and bone morphology. Thirty-two (16 males and 16 females) 83- to 86-week-old beagle dogs were treated p.o. for up to 3 years with ALN at 0.00, 0.25, 0.5 or 1.0 mg/kg/day. The following parameters of toxicity were assessed: physical signs, body weight, ophthalmology, radiographic evaluation of bone, electrocardiography, hematology, clinical chemistry, urinalysis, necropsy including organ weight assessment, histopathology and biomechanical testing of bone. There were no apparent compound-related alterations in any of the above mentioned parameters except the expected changes (related to the pharmacological activity of ALN) in serum phosphorus and Ca concentrations and in the histology of bones with active endochondral bone formation (rib). There were mild transient reductions in the serum phosphorus and Ca concentrations at the 1.0 mg/kg/day dose level during the early part of the study. There was a dose-dependent delay in bone remodeling in the ribs of all dogs treated with ALN. There was no similar change in the tibia. Most importantly, there were no spontaneous fractures and there were no changes in the structural properties of femoral or vertebral bone. The total ALN content of bone in an average dog (10 kg) after 3 years of treatment with approximately five items of the intended dose for the treatment of osteoporosis was approximately 8 mg, which is only 0.001% of total bone mass (700 g). Introduction.

Administration, Oral↗

Flexibility and distraction after monosegmental and bisegmental lumbosacral fixation with angular stable fixators.

STUDY DESIGN: In human lumbosacral spines, the flexibility and intersegmental distraction allowed by four monosegmental and bisegmental intrapedicular devices during compression and flexion/compression loading were investigated. OBJECTIVES: To compare the flexibility and intersegmental distraction allowed by four monosegmental and bisegmental intrapedicular, lumbosacral fixation devices applied to destabilized cadaveric spines, and to determine the effect of each device on the flexibility and intersegmental distraction of the motion segment above each fused segment. SUMMARY OF BACKGROUND DATA: The lumbosacral segment is the most mobile region in the lumbar spine, exhibiting the highest range of motion in both flexion and extension. Therefore, the fixation of this and the adjacent segment is of special clinical interest. METHODS: L5-S1 facetectomy or L5 laminectomy procedures were performed on cadaveric human lumbosacral spines. Fixation devices then were applied across one or two levels, and intersegmental motion under flexion/compression or under pure compression loads was monitored. RESULTS: The flexibility and posterior strain allowed by the four implants did not differ significantly between implants. The strain across the stabilized site (monosegmental and bisegmental) was below 10% for all devices tested. The flexibility and distraction were reduced to levels below intact after the fixators were applied. The distraction across the segment above the fusion was not increased because of fixation with these four fixators. CONCLUSIONS: Angular stable fixation devices, such as those described here, provide adequate stabilization of the posteriorly destabilized spine.

Adult↗

Maxillary molar extraction causes increased bone loss in the mandible of ovariectomized rats.

Although osteoporosis is a major public health concern, its effect on oral bone has not been determined. More important may be the effect of estrogen depletion on the response of oral bone to dental treatments such as tooth extraction or pathologic processes such as periodontal disease. Our objective was to determine if maxillary molar extraction increases mandibular bone loss in the ovariectomized compared with a sham-operated control. Fifty-three ovariectomized and 53 sham-operated 6-month-old Sprague-Dawley rats were randomly assigned to the following groups: (1) ovariectomized, adult; (2) sham-operated, adult; (3) ovariectomized, adult, extraction; (4) sham-operated, adult, extraction; (5) ovariectomized, old; (6) sham-operated, old; (7) ovariectomized, old, extraction; and (8) sham-operated, old, extraction. Fourteen days following ovariectomy, the extraction groups had their bilateral maxillary molars extracted. The adult and old rats were sacrificed 114 and 200 days postovariectomy, respectively. The right mandible was tested to failure in three point bending. The bone mineral density (BMD) of the left mandible was measured with high resolution dual energy X-ray absorptiometry. The area fraction and area moment of inertia of mandible sections were determined using image processing software. In the ovariectomized rats, maxillary molar extraction resulted in decreases (p < 0.05) in the failure load (21%), stiffness (39%), BMD (3%), and bone area fraction (8%) of the mandible. However, in the sham-operated rats, these decreases following maxillary molar extraction were less (p < 0.05) than those in the ovariectomized rats and only present in the mandibles of the aged rats.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Force attenuation in trochanteric soft tissues during impact from a fall.

The risk for hip fracture from a fall is known to decrease with increased body mass index (weight/height2), a relative measure of obesity. To explore whether this reduced risk is due to the protective effect of increased soft-tissue cushioning in obese individuals, we used an impact pendulum and surrogate human pelvis to conduct simulated fall impact experiments on trochanteric soft tissues harvested from the cadavers of nine elderly individuals. For each impact, the total applied energy was 140 J. Peak forces ranged from 4,050 to 6,420 N, and tissue energy absorption ranged from 8.4 to 81.6 J. Increased tissue thickness correlated strongly with both decreased peak force (r2 = 0.91) and increased tissue energy absorption (r2 = 0.76). However, peak forces in all cases were within 1 SD of previously reported average fracture forces for elderly cadaveric femora. This suggests that force attenuation in trochanteric soft tissues alone is insufficient to prevent hip fracture in falls in which an elderly person lands directly on the hip. In such falls, additional energy-absorbing mechanisms, such as breaking the fall with an outstretched hand and eccentric contraction of the quadriceps during descent, are likely to be involved if fracture does not occur.

Accidental Falls↗

Ultrasound and densitometry of the calcaneus correlate with the failure loads of cadaveric femurs.

We assessed the bone mineral density (BMD) of 16 matched sets of cadaveric proximal femurs and feet using dual-energy x-ray absorptiometry (DXA). We also estimated the femoral neck length from the DXA scans. Quantitative ultrasound densitometry was used to measure the velocity of sound and broadband ultrasound attenuation (BUA) in the calcaneus of each foot. The proximal femurs were then tested to failure in a loading configuration designed to simulate a fall with impact to the greater trochanter. Femoral neck BMD and trochanteric BMD were strongly associated with the femoral failure load (r2 = 0.79 and 0.81, respectively; P < 0.001), whereas femoral neck length was modestly correlated with femoral failure load (r2 = 0.27, P = 0.04). Calcaneal BMD (r2 = 0.63, P < 0.001) and BUA (r2 = 0.51, P = 0.002) were also significantly associated with femoral failure load. Given the small sample size, we were unable to detect differences in the strength of the correlations between the independent parameters and femoral failure load. Using linear multiple regression analyses, the strongest predictor of femoral failure load was a combination of femoral neck BMD and femoral neck length (R2 = 0.85, P < 0.001). Thus, it appears that both femoral and calcaneal bone mineral properties may be useful for identifying those persons at greatest risk for hip fracture.

Absorptiometry, Photon↗

Ovariectomy decreases the bone area fraction of the rat mandible.

Although osteoporosis is a major public health concern, the effect of this condition on oral bone has not been determined. Using the ovariectomized rat, we tried to determine if estrogen depletion and aging affect the mandible of the rat. Sixty-one ovariectomized (ovx) and sham-operated (sham) 6-month-old Sprague Dawley rats were divided equally into six groups. The baseline, adult, and old rats were euthanized 14, 114, 200 days post-ovx, respectively. The bone mineral density of the mandible was measured using high resolution dual energy x-ray absorptiometry. The failure load and stiffness of the mandible were measured in three-point bending. The bone area fraction and area moment of inertia of digitized images of mandible sections were measured using image analyzing software. In adult rats, ovx led to a 15% and 28% increase in failure load and stiffness, respectively, but no change in bone area fraction or bone mineral density. In the old rats, ovx led to an 8% decrease in bone area fraction, but no change in failure load, stiffness, or bone mineral density of the mandible. In the ovx rats, aging led to a 20% and 7% decrease in stiffness and bone area fraction of the mandibles in the old rats compared with that in the adult rats. In the adult ovx rats, the increase in structural properties of the mandible may be a consequence of an increase in masticatory function as it has been reported that ovx rats eat approximately 10% more than sham controls.(ABSTRACT TRUNCATED AT 250 WORDS)

Aging↗

Stress distributions within the proximal femur during gait and falls: implications for osteoporotic fracture.

The rates of fracture at sites with different relative amounts of cortical and trabecular bone (hip, spine, distal radius) have been used to make inferences about the pathomechanics of bone loss and the existence of type I and type II osteoporosis. However, fracture risk is directly related to the ratio of tissue stress to tissue strength, which in turn is dependent not only on tissue composition but also tissue geometry and the direction and magnitude of loading. These three elements determine how the load is distributed within the tissue. As a result, assumptions on the relative structural importance of cortical and trabecular bone, and how these tissues are affected by bone loss, can be inaccurate if based on regional tissue composition and bone density alone. To investigate the structural significance of cortical and trabecular bone in the proximal femur, and how it is affected by bone loss, we determined the stress distributions in a normal and osteoporotic femur resulting from loadings representing: (1) gait; and (2) a fall to the side with impact onto the greater trochanter. A three-dimensional finite element model was generated based on a representative femur selected from a large database of femoral geometries. Stresses were analyzed throughout the femoral neck and intertrochanteric regions. We found that the percentage of total load supported by cortical and trabecular bone was approximately constant for all load cases but differed depending on location. Cortical bone carried 30% of the load at the subcapital region, 50% at the mid-neck, 96% at the base of the neck and 80% at the intertrochanteric region. These values differ from the widely held assumption that cortical bone carries 75% of the load in the femoral neck and 50% of the load at the intertrochanteric region. During gait, the principal stresses were concentrated within the primary compressive system of trabeculae and in the cortical bone of the intertrochanteric region. In contrast, during a fall, the trabecular stresses were concentrated within the primary tensile system of trabeculae with a peak magnitude 4.3 times that present during gait. While the distribution of stress for the osteoporotic femur was similar to the normal, the magnitude of peak stress was increased by between 33% and 45%. These data call into question several assumptions which serve as the basis for theories on the pathomechanics of osteoporosis. In addition, we expect that the insight provided by this analysis will result in the improved development and interpretation of non-invasive techniques for the quantification of in vivo hip fracture risk.

Accidental Falls↗

Effects of selected thermal variables on the mechanical properties of trabecular bone.

Osteoarticular allografts are commonly used in the treatment of segmental bone loss due to a wide resection of tumour. While the use of such grafts has met with considerable clinical success, fractures are a recognized complication of allograft use. Although trabecular bone can play an important structural role in the function of segmental allografts, few data exist on the effects of common storage and sterilization procedures on the mechanical properties of trabecular bone. To this end, we investigated with these experiments the effects of freezing at -20 degrees C, freezing at -70 degrees C, eight freeze-thaw cycles at -20 degrees C, freeze-drying, boiling and autoclaving on the compressive modulus and strength of bovine trabecular bone. Of these treatments, boiling and autoclaving were the only treatments to alter the properties of bovine trabecular bone, resulting in 26 and 58% reductions in strength, respectively. Autoclaving also significantly reduced the compressive modulus by 59%. From these data, freezing at temperatures between -20 and -70 degrees C does not appear to compromise the structural integrity of trabecular bone.

Animals↗

Bone suture anchors in hand surgery.

The recent development of small bone suture anchors has created potential applications in reconstructive surgery of the hand and wrist. A combined laboratory and clinical study was devised to evaluate their use. 16 paired fingers (32 in all) from eight cadaveric hands were disarticulated at the MP joint with a 10 cm tail of FDP tendon. The FDP insertion was released in all specimens. In 16 fingers reinsertion was performed with the classic Bunnell technique; in the paired 16 fingers, the repair utilized Acufex 2 mm anchors. There was no significant difference between the two groups regarding load-to-failure at approximately 40 Newtons. The mean stiffness of the anchor repairs was significantly greater than the Bunnell repairs. 19 consecutive patients were prospectively enrolled with a tendon or ligament repair of the hand or wrist using bone anchors. The average age was 41 years and the average length of follow-up was 24 months. All repairs were stable at the time of follow-up. Bone anchors were simple to insert, required less dissection and surgical time than the Bunnell technique and appeared to be reliable in both laboratory and clinical settings.

Adult↗

Patellofemoral contact pressures exceed the compressive yield strength of UHMWPE in total knee arthroplasties.

To address mechanisms involved in wear and permanent deformation of patellofemoral components in total knee arthroplasties, a previously reported knee joint loading model and pressure-sensitive film were used to measure patellofemoral contact areas and pressures in human cadaver knee joints after implantation with six different total knee joint designs. The joints were tested at three different Q angles (physiologic, -10 degrees, and +10 degrees) and four different flexion angles (30 degrees, 60 degrees, 90 degrees, and 120 degrees). Patellofemoral contact areas at normal Q angles ranged from 0.13 to 0.68 cm2 and increased with flexion angle up to 90 degrees. These contact areas differed significantly with flexion angle but not with Q angle. Variations in contact area with type of knee system were only marginally significant (P < .04), and post hoc tests showed no significant differences between individual knee designs. Contact pressures at normal Q angle also increased with flexion angle and ranged from 10 MPa to more than 49 MPa. Contact pressures at flexion angles greater than 60 degrees were, for all systems, well in excess of the compressive yield strength of ultrahigh-molecular-weight polyethylene and at least three to four times greater than the recommended maximum compressive stress level of 10 MPa.

Adult↗

Dynamic models for sideways falls from standing height.

Despite our growing understanding of the importance of fall mechanics in the etiology of hip fracture, previous studies have largely ignored the kinematics and dynamics of falls from standing height. Beginning from basic principles, we estimated peak impact force on the greater trochanter in a sideways fall from standing height. Using a one degree-of-freedom impact model, this force is determined by the impact velocity of the hip, the effective mass of that part of the body that is moving prior to impact, and the overall stiffness of the soft tissue overlying the hip. To determine impact velocity and effective mass, three different paradigms of increasing complexity were used: 1) a falling point mass or a rigid bar pivoting at its base; 2) two-link models consisting of a leg segment and a torso; and 3) three-link models including a knee. The total mechanical energy of each model before falling was equated to the total mechanical energy just prior to impact in order to estimate the hip impact velocity. In addition, the configuration of the model just before impact was used to estimate the effective mass. Our model predictions were compared with the results of an earlier experimental study with young subjects falling on a 10-inch thick mattress. Values from literature were used to estimate the soft tissue stiffness. For the models, predicted values for hip impact velocity and effective mass ranged from 2.47 to 4.34 m/s and from 15.9 to 70.0 kg, respectively. Predicted values for the peak force applied to the greater trochanter ranged from 2.90k to 9.99k N. Based on comparisons to the experimental falls, impact velocity and impact force were best predicted by a simple two-link model with the trunk at 45 degrees to the vertical at impact. A three-link model with a quadratic spring incorporated in the knee of the model was the best predictor of effective mass. Using our most accurate model, the peak impact force was 2.90k N for a 5th percentile female and 4.26k N for a 95th percentile female, thereby confirming the widely held perception that "the bigger they are, the harder they fall".

Accidental Falls↗

Optimization technique for the calculation of in vitro three-dimensional vertebral motion.

A method for the calculation of translations and Eulerian rotations of an orthogonal axis system with respect to a fixed reference is described with application to the measurement of position in a vertebral motion segment. Kinematic equations were derived to compute the three-dimensional motion of a moving vertebra relative to an adjacent fixed body, without the requirement of a direct physical link between the two bodies. For this calculation, the quadratic error of the lengths of six position vectors was minimized to obtain a mathematically optimal estimate of the translations and rotations. Tests with a rigid model resulted in mean maximum overall system errors of 2.8 percent for the measurement of translation (translations less than 3.5 mm) and 6.1 percent for the measurement of rotations (rotations less than 10 deg) limited by transducer accuracy. The mathematical techniques presented for the quantitative description of rigid body motion, based on the measurement of three reference vectors, may be extended to a broad range of kinematic problems.

Biomechanical Phenomena↗

Energy-shunting hip padding system attenuates femoral impact force in a simulated fall.

Recent studies suggest that hip padding systems reduce the incidence of hip fractures during falls. However, no data exist on the force attenuating capacity of hip pads under realistic fall impact conditions, and thus it is difficult to compare the protective merit of various pad designs. Our goal is to design a comfortable hip padding system which reduces femoral impact force in a fall below the mean force required to fracture the elderly cadaveric femur. In pursuit of this objective, we designed and constructed a hip pad testing system consisting of an impact pendulum and surrogate human pelvis. We then developed a hip pad containing a shear-thickening material which allows for shunting of the impact energy away from the femur and into the surrounding soft tissue. Finally, we conducted experiments to assess whether the surrogate pelvis accurately represents the impact behavior of the human female pelvis in a fall, and to determine whether our energy-shunting pad attenuates femoral impact force in a fall more effectively than seven available padding systems. We found the surrogate pelvis accurately represented the human female pelvis in regional variation in soft tissue stiffness, total effective stiffness and damping, and impact force attenuation provided by trochanteric soft tissues. We also found that our padding system attenuated femoral impact force by 65 percent, thereby providing two times the force attenuation of the next best system. Moreover, the energy-shunting pad was the only system capable of lowering femoral impact force well below the mean force required to fracture the elderly femur in a fall loading configuration. These results suggest that the force attenuating potential of hip pads which focus on shunting energy away from the femur is superior to those which rely on absorbing energy in the pad material. While these in-vitro results are encouraging, carefully designed prospective clinical trials will be necessary to determine the efficacy of these approaches to hip fracture prevention.

Accidental Falls↗

Comparison of alendronate and sodium fluoride effects on cancellous and cortical bone in minipigs. A one-year study.

Fluoride stimulates trabecular bone formation, whereas bisphosphonates reduce bone resorption and turnover. Fracture prevention has not been convincingly demonstrated for either treatment so far. We compared the effects of 1-yr treatment of 9-mo-old minipigs with sodium fluoride (NaF, 2 mg/kg/d p.o.) or alendronate (ALN, 4 amino-1-hydroxybutylidene bisphosphonate monosodium, 1 mg/kg/d p.o.) on the biomechanical and histomorphometric properties of pig bones. As expected, NaF increased and ALN decreased bone turnover, but in these normal animals neither changed mean bone volume. NaF reduced the strength of cancellous bone from the L4 vertebra, relative to control animals, and the stiffness (resistance to deformation) of the femora, relative to the ALN group. In the ALN-treated animals, there was a strong positive correlation between bone strength and L5 cancellous bone volume, but no such correlation was observed in the NaF group. Furthermore, the modulus (resistance to deformation of the tissue) was inversely related to NaF content and there was a relative decrease in bone strength above 0.25 mg NaF/g bone. Moreover, within the range of changes measured in this study, there was an inverse correlation between bone turnover, estimated as the percentage of osteoid surface, and modulus. These findings have relevant implications regarding the use of these agents for osteoporosis therapy.

Alendronate↗

Age-related reductions in the strength of the femur tested in a fall-loading configuration.

UNLABELLED: To assess age-related changes in femoral strength as a component in the risk of fracture of the hip, we compared the loads at fracture of the proximal aspects of femora from the cadavera of older and younger individuals, as tested in a fall-loading configuration. To provide a basis for non-invasive in vivo estimates of femoral strength, we also determined the correlations between variables measured with dual-energy x-ray absorptiometry and these loads. Femora from the cadavera of eight older individuals (mean age, seventy-four years) and nine younger individuals (mean age, thirty-three years) were scanned with a Hologic QDR-2000 densitometer to obtain densitometric and geometric information. The femora were then tested mechanically in a loading configuration that simulated a fall on the greater trochanter. The femora from the older group were half as strong as those from the younger group (p < 0.001), and they absorbed one-third as much energy (p < 0.001). The area bone-mineral density of the femoral neck correlated strongly with the load at fracture (r2 = 0.92). CLINICAL RELEVANCE: The prevalence of fracture of the hip increases exponentially with age. 90 percent of those fractures are the result of a simple fall from a standing height.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗