Search PubMed⌕ Search

Biomedical subjects

W Bonfield

Publications and source records attributed to W Bonfield.

At least 37 records · Page 2Linked to original sources

A "healthy apatite" for bone repair.

Bone is unique in its ability to adapt structure to functional requirements, but as is all too obvious in an ever-ageing population it is susceptible to a number of degenerative diseases. Therefore there is an increasing need for materials for bone replacement. Clearly, the ideal material with which to replace bone, would be bone itself, but the major problem now facing us is that there is an insufficient supply of the natural bone to satisfy the clinical requirements. Hence, there is a need for the development of chemically synthesised bone graft substitutes

Animals↗

Bonding strength of the apatite layer formed on glass-ceramic apatite-wollastonite-polyethylene composites.

Bioactive glass-ceramic apatite-wollastonite (A-W) has been incorporated into polyethylene in particulate form to create new bioactive composites for potential maxillofacial applications. The effects of varying the volume fraction of glass-ceramic A-W filler and the glass-ceramic A-W particle size were investigated by measuring the bonding strength of the bonelike apatite layer formed on the surface of glass-ceramic A-W-polyethylene composites. The bonding strength was evaluated via a modified ASTM C-333 standard in which a tensile stress was applied to the substrate and the strength of the bioactive layer was compared with that formed on commercially available hydroxyapatite-polyethylene composite samples, HAPEX. The composites demonstrated greater bonding strength with increased filler content and reduced filler particle size (maximum 6.9 +/- 0.5 MPa) and a marginally greater bonding strength as compared with HAPEX (2.8 +/- 0.5 MPa), when glass-ceramic A-W-polyethylene composite samples with the same filler content were tested. The higher bonding strength of the apatite layer formed on the A-W-polyethylene composite samples suggests that, in addition to maxillofacial applications, these composites might also be utilized in applications involving higher levels of load bearing.

Adhesiveness↗

Calcium phosphate coatings obtained by Nd:YAG laser cladding: physicochemical and biologic properties.

The plasma spray (PS) technique is the most popular method commercially in use to produce calcium phosphate (CaP) coatings to promote fixation and osteointegration of the cementless prosthesis. Nevertheless, PS has some disadvantages, such as the poor coating-to-substrate adhesion, low mechanical strength, and brittleness of the coating. In order to overcome the drawbacks of plasma spraying, we introduce in this work a new method to apply a CaP coating on a Ti alloy using a well-known technique in the metallurgical field: laser surface cladding. The physicochemical characterization of the coatings has been carried out by means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive X-ray analysis (EDX). The biologic properties of the coatings have been assessed in vitro with human osteoblast-like MG-63 cells. The overall results of this study affirm that the Nd:YAG laser cladding technique is a promising method in the biomedical field.

Alloys↗

Experimental validation of a microcracking-based toughening mechanism for cortical bone.

It has been proposed that cortical bone derives its toughness by forming microcracks during the process of crack propagation (J. Biomech. 30 (1997) 763; J. Biomech. 33 (2000) 1169). The purpose of this study was to experimentally validate the previously proposed microcrack-based toughening mechanism in cortical bone. Crack initiation and propagation tests were conducted on cortical bone compact tension specimens obtained from the antlers of red deer. For these tests, the main fracture crack was either propagated to a predetermined crack length or was stopped immediately after initiating from the notch. The microcracks produced in both groups of specimens were counted in the same surface area of interest around and below the notch, and crack growth resistance and crack propagation velocity were analyzed. There were more microcracks in the surface area of interest in the propagation than in initiation specimens showing that the formation of microcracks continued after the initiation of a fracture crack. Crack growth resistance increased with crack extension, and crack propagation velocity vs. crack extension curves demonstrated the characteristic jump increase and decrease pattern associated with the formation of microcracks. The scanning electron micrographs of crack initiation and propagation displayed the formation of a frontal process zone and a wake, respectively. These results support the microcrack-based toughening mechanism in cortical bone. Bone toughness is, therefore, determined by its ability to form microcracks during fracture.

Animals↗

Comparison of in vivo dissolution processes in hydroxyapatite and silicon-substituted hydroxyapatite bioceramics.

The incorporation of silicate into hydroxyapatite (HA) has been shown to significantly increase the rate of bone apposition to HA bioceramic implants. However, uncertainty remains about the mechanism by which silicate increases the in vivo bioactivity of HA. In this study, high-resolution transmission electron microscopy was used to observe dissolution from HA, 0.8 wt% Si-HA and 1.5 wt% Si-HA implants after 6 and 12 weeks in vivo. Our observations confirmed that defects, in particular those involving grain boundaries, were the starting point of dissolution in vivo. Dissolution was observed to follow the order 1.5 wt% Si-HA>0.8 wt% Si-HA>pure HA and it was found to be particularly prevalent at grain boundaries and triple-junctions. These observations may help to explain the mechanism by which silicate ions increase the in vivo bioactivity of pure HA, and highlight the enhanced potential of these ceramics for biomedical applications.

Animals↗

The effect of varying percentage hydroxyapatite in poly(ethylmethacrylate) bone cement on human osteoblast-like cells.

Poly(ethylmethacrylate) (PEMA) bone cement has been developed, and the cements mechanical properties are improved by the incorporation of particulate fillers, such as hydroxyapatite (HA). In this in vitro study, human osteoblast-like (HOB) cells were used to examine the effect on cellular behavior of the addition of HA to PEMA using a plain PEMA control. Thymidine uptake ((3)H-TdR) and total DNA were used to assess cell growth and proliferation. Confocal laser scanning microscopy (CLSM) was used to study focal contacts and actin cytoskeletal organisation. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to assess cell morphology and cellular ultrastucture. The early time points showed preferential anchorage to the HA exposed on the cement surface, but no difference in adhesion or proliferation. These results have been attributed to increases in residual monomer with HA incorporation, as shown by proton nuclear magnetic resonance (H(1)-NMR) spectra.

Journal Article↗

Apatite-forming ability of glass-ceramic apatite-wollastonite - polyethylene composites: effect of filler content.

The bioactivity of a range of glass-ceramic apatite-wollastonite (A-W) - polyethylene composites (AWPEXs) with glass-ceramic A-W volume percentages ranging from 10 to 50, has been investigated in an acellular simulated body fluid (SBF) with ion concentrations similar to those of human blood plasma. The formation of a biologically active apatite layer on the composite surface after immersion in SBF was demonstrated by thin-film X-ray diffraction (TF-XRD) and field-emission scanning electron microscopy (FE-SEM). An apatite layer was formed on all the composites, with the rate of formation increasing with an increase in glass-ceramic A-W percentage. For composites with glass-ceramic A-W filler contents >or=30 vol %, the apatite layer was formed within 12 h of immersion, which is a comparable time for apatite formation on monolithic glass-ceramic A-W. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) demonstrated that the apatite formation on AWPEX samples with 50 vol % filler content occurred in a manner similar to that seen on pure glass-ceramic A-W, in that the calcium, silicon, and magnesium ion concentrations increased and, conversely, a decrease was observed in the phosphate ion concentration. These results indicate that a suitable in vitro response was achieved on a composite incorporating particulate glass-ceramic A-W with a particularly favorable response being observed on the AWPEX sample with 50 vol % filler content.

Journal Article↗

Enhanced HAPEX topography: comparison of osteoblast response to established cement.

The use of poly(methylmethacrylate) PMMA cement by Charnley in the 1960s revolutionized orthopaedic medicine. Since this time, however, little has changed. The development of bioactive composites, such as HAPEX (a composite of 40% vol hydroxyapatite (HA) in a polyethylene matrix) have potential in orthopaedic applications. The composite has been shown to allow direct bone bonding in vivo, and in vitro studies have shown preferential attachment to HA exposed on the composite surface. In vitro study has also shown that altering the topography HAPEX can enhance osteoblast response. This study uses microscopical investigation of osteoblast cytoskeleton, and biochemical measurement of proliferation (by thymidine incorporation) and phenotype (by alkaline phosphatase activity) to compare primary human osteoblast (HOB) activity on HAPEX and PMMA cement. The study shows large increases in HOB response to the new generation material compared to PMMA, the current implant standard.

Journal Article↗

Osteoblast behaviour on HA/PE composite surfaces with different HA volumes.

A hydroxyapatite (HA) reinforced polyethylene (PE) composite (designated HAPEX), with high mechanical specification and a bioactive HA phase, has been optimised as a bone analogue material. Manufacturing conditions and machining of the materials were carefully controlled to give a reproducible material surface roughness with minimal batch variation. The effect of surface composition was examined in vitro using primary human osteoblasts (HOB). HOBs were cultured in direct contact with the test materials containing 20% and 40% vol. HA. The results showed that 40% HA/PE enhanced cellular activity by increasing proliferation rate and differentiation compared to the 20% vol. HA composite. The cytoskeletal organisation of the cells was also examined and HOBs cultured on 40% HA/PE were flatter and had an enhanced rate of cytoskeletal organisation and an increase in focal contact points compared to the 20% HA/PE.

Cell Differentiation↗

Increasing hydroxyapatite incorporation into poly(methylmethacrylate) cement increases osteoblast adhesion and response.

Poly(methylmethacrylate) (PMMA) is the current standard for cement held prostheses. It forms a strong bond with the implant, but the bond between the cement and the bone is considered to be weak, with fibroblastic cells observed at the implant site, rather than direct bone contact, a contributing factor leading to implant failure. Incorporation of hydroxyapatite (HA) increases the biological response to the cement from tissue around the implant site, thus giving increased bone apposition. In this study, PMMA discs with 0, 4.6 and 8.8 vol%. HA were examined. Primary human osteoblast-like cells (HOBs) were used for the biological evaluation of the response to the cements in vitro. Morphology was observed using scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Measurement of tritiated thymidine (3H-TdR) incorporation and alkaline phosphatase (ALP) activity were used to assess proliferation and differentiation. A synergy between increasing focal contact formation, cytoskeletal organisation, cell proliferation and expression of phenotype was observed with increasing HA volume. Preferential anchorage of HOBs to HA rather than PMMA was a prominent observation.

Bone Cements↗

Initial attachment of osteoblasts to an optimised HAPEX topography.

The interactions between an implant material and the surrounding tissue are of a complicated nature, and the initial attachment of cells to the surface is important in determining the implant success. HAPEX has been developed as a second-generation orthopaedic biomaterial, with both mechanical and biological characteristics that make it suitable for bone augmentation. Further optimisation of the material is being continued to increase the attachment of osteoblasts coupled with improving mechanical characteristics, so it may be used in load bearing applications. It has been previously observed that polishing followed by roughening the surface of HAPEX enhances osteoblast proliferation and phenotype. This article discusses the recruitment of primary human osteoblast cells onto the optimised surface, by examining morphology and cytoskeletal changes using scanning electron microscopy and confocal laser scanning microscopy. The results show that the cells attach in greater numbers to the optimised surface, and develop notably faster, than cells on machined HAPEX.

Arthroplasty, Replacement, Hip↗

In vitro adhesion and biocompatability of osteoblast-like cells to poly(methylmethacrylate) and poly(ethylmethacrylate) bone cements.

A bone cement, poly(ethylmethacrylate)/n-butylmethacrylate (PEMA/nBMA) has been developed with lower exotherm and monomer leaching compared to the traditional poly(methylmethacrylate)/methylmethacrylate (PMMA/MMA) cement. This study compares the in vitro biological response to the cements using primary human osteoblast-like cells (HOB). Cell attachment was qualified by immunolocalization of vinculin and actin cytoskeleton, showing more organization on PEMA/nBMA compared to PMMA/MMA. Proliferation was assessed using tritiated thymidine incorporation, and phenotype expression determined by measuring alkaline phosphatase (ALP) activity. An increase in proliferation and ALP activity was observed on PEMA/nBMA compared to PMMA/MMA. The results confirm the biocompatability of PEMA/nBMA, and an enhanced cell attachment and expression of differentiated cell phenotype.

Journal Article↗

Friction and wear of hydroxyapatite reinforced high density polyethylene against the stainless steel counterface.

Hydroxyapatite (HA) reinforced high density polyethylene (HDPE) was invented as a biomaterial for skeletal applications. In this investigation, tribological properties (e.g. wear rate and coefficient of friction) of unfilled HDPE and HA/HDPE composites were evaluated against the duplex stainless steel in dry and lubricated conditions, with distilled water or aqueous solutions of proteins (egg albumen or glucose) being lubricants. Wear tests were conducted in a custom-built test rig for HDPE and HA/HDPE containing up to 40 vol % of HA. It was found that HA/HDPE composites had lower coefficients of friction than unfilled HDPE under certain conditions. HA/HDPE also exhibited less severe fatigue failure marks than HDPE. The degradation and fatigue failure of HDPE due to the presence of proteins were severe for low speed wear testing (100 rpm) as compared to high speed wear testing (200 rpm). This was due possibly to the high shear rate at the contact which could remove any degraded film instantaneously at high sliding speed, while with a low sliding speed the build-up of a degraded layer of protein could occur. The degraded protein layer would stay at the contact for a longer time and mechanical activation would induce adverse reactions, weakening the surface layer of HDPE. Both egg albumen and glucose were found to be corrosive to steel and adversely reactive for HDPE and HA/HDPE composites. The wear modes observed were similar to that of ultra-high molecular weight polyethylene. Specimens tested with egg albumen also displayed higher wear rates, which was again attributed to corrosion accelerated wear.

Journal Article↗

Thermal decomposition of synthesised carbonate hydroxyapatite.

Heat treatments are used when sintering hydroxyapatite to make porous blocks and granules and during plasma spraying of coatings. Calcium : phosphorus ratio is known to affect the thermal decomposition behavior of hydroxyapatite. Hydroxyapatite with carbonate ions substituted for phosphate ions is more similar in composition to bone mineral. While it has been shown that carbonate apatite may be sintered, relatively little is known about its high temperature stability. Various atmospheres have been used in investigations into the thermal stability of hydroxyapatites and carbonate hydroxyapatites, including nitrogen, wet carbon dioxide air, water vapor and wet oxygen, but few of these studies were directly comparable. Previous work has shown that loss of carbonate from CHA at high temperature is time dependent, which suggests that rapid high temperature treatment may prevent carbonate loss during processing. This study investigated the effect of dry carbon dioxide, carbon dioxide containing 3% water, nitrogen and nitrogen containing 3% water on the phase composition of hydroxyapatite containing between 1.0 and 11.5 wt % carbonate rapidly heated to temperatures of between 700 and 1400 degrees C. Carbonate ion substitution was observed to decrease the temperature at which crystallisation occurred to a minimum of 700 degrees C for 11.8 wt % carbonate apatite heated in wet atmospheres. Atmosphere was found to appreciably affect the crystallization temperature and phase transformations of carbonate apatite containing 7.8 wt % carbonate. In wet and dry carbon dioxide atmospheres, crystallisation began in this material at 1100 and 900 degrees C, betaTCP was formed at 1500 and 1300 degrees C respectively. The high temperature decomposition of carbonate hydroxyapatite would appear to depend on the composition of the apatite and the atmosphere in which it is heated.

Journal Article↗

Preparation and characterization of magnesium/carbonate co-substituted hydroxyapatites.

A new synthesis/processing method has been devised to produce magnesium/carbonate co-substituted hydroxyapatite ceramics that do not decompose to tricalcium phosphate (TCP) on sintering. Using this method, a series of magnesium/carbonate co-substituted hydroxyapatite (Mg/CO(3)-HA) compositions, containing between 0 and 0.35 wt % Mg and approximately 0.9 wt % CO(3) were prepared. Sintering the Mg/CO(3)-HA compositions in a CO(2)/H(2)O atmosphere yields a single crystalline phase that appears to be identical to stoichiometric HA. In contrast, when the compositions were prepared in the absence of carbonate and were sintered in air, the phase composition was a biphasic mixture of HA and TCP e.g. for 0.25 wt % Mg substitution the phase composition was approximately 60%HA/40% TCP. Clearly, both the synthesis route and the processing (i.e. sintering) route are of importance in the production of a single-phase Mg/CO(3)-HA ceramic. Fourier transform infrared (FTIR) spectroscopy has indicated that the Mg/CO(3)-HA ceramics still contained carbonate groups after sintering at 1200 degrees C. Chemical analysis by X-ray fluorescence spectroscopy (XRF) and C-H-N analysis has shown that the cation/anion molar ratio (i.e. [Ca+Mg]/[P+C/2]) of the different compositions were 1.68(+/-0.01), which is equivalent to the Ca/P molar ratio of stoichiometric HA. Although the magnesium/carbonate co-substitution had a positive effect in preventing phase decomposition during sintering, it appeared to have a negative effect on the densification of the MgCO(3)-HA ceramics, compared to stoichiometric HA.

Journal Article↗

A comparative study on the in vivo behavior of hydroxyapatite and silicon substituted hydroxyapatite granules.

Phase pure hydroxyapatite (HA) and a 0.8 wt % silicon substituted hydroxyapatite (SiHA) were prepared by aqueous precipitation methods. Both HA and SiHA were processed into granules 0.5-1.0 mm in diameter and sintered at 1200 degrees C for 2 h. The sintered granules underwent full structural characterization, prior to implantation into the femoral condyle of New Zealand White rabbits for a period of 23 days. The results show that both the HA and SiHA granules were well accepted by the host tissue, with no presence of any inflammatory cells. New bone formation was observed directly on the surfaces and in the spaces between both HA and SiHA granular implants. The quantitative histomorphometry results indicate that the percentage of bone ingrowth for SiHA (37.5%+/-5.9) was significantly greater than that for phase pure HA (22.0%+/-6.5), in addition the percentage of bone/implant coverage was significantly greater for SiHA (59.8%+/-7.3) compared to HA (47.1%+/-3.6). These findings indicate that the early in vivo bioactivity of hydroxyapatite was significantly improved with the incorporation of silicate ions into the HA structure, making SiHA an attractive alternative to conventional HA materials for use as bone substitute ceramics.

Journal Article↗

Dynamic mechanical characterization of biodegradable composites of hydroxyapatite and polylactides.

The thermo-mechanical analysis of some novel, totally bioactive, three-component composite systems intended for the repair and augmentation of bone has been performed. The composites are composed of hydroxyapatite (HA), particulate reinforced biodegradable polylactic acid (PDLLA), with a second reinforcing phase of semi-crystalline, unidirectional fibers of polylactic acid (PLLA) homopolymer. Dynamic mechanical analysis (DMA) applied small-strain cyclic deformations to simulate physiological loading. The effect of the two fillers on the glass transition temperature of the matrix (Tg-PDLLA) and on the viscoelastic parameters, storage modulus (EI), and tan delta were analyzed. Thermal characterization with differential scanning calorimetry (DSC) was compared to the DMA data. It was established that the addition of HA and/or PLLA fibers increased EI, both below and above Tg-PDLLA. The combination of both reinforcing agents was the most effective. The damping was reduced with the addition of HA alone and in combination with PLLA fibers. Tg-PDLLA was increased by the addition of HA, PLLA fibers, and the combination of the two reinforcing agents. The magnitude of the increase in Tg-PDLLA was similar for both types of reinforcement.

Biocompatible Materials↗