Effect of externally applied pressure on femoral vein blood flow.

The effect of incremental increases in external pressure, applied to the leg, on blood volume flow in the femoral vein was studied in dogs. Clinical investigation of external pressure increases was also carried out on nine patients undergoing surgery for varicose veins. An external pressure between 5 and 15 mm. Hg caused a sustained increase in mean femoral vein flow both in a control and in the compressed limb. Above 15 mm. Hg external pressure flow decreased in the compressed limb but was maintained at an increased level in the control limb.If external compression is to be used to prevent and treat deep vein thrombosis its application must be carefully controlled.

Animals↗

A combined ultrasonic linear array scanner and pulsed Doppler velocimeter for the estimation of blood flow in the foetus and adult abdomen--I: Technical aspects.

A method is proposed for estimating the volume blood flow of deep lying vessels in the foetus and in adult portal vein and renal vessels. The equipment combines a 3.5 MHz linear array scanner with a 2 or 4 MHz pulsed Doppler. The pulsed Doppler tranducer is connected to the linear array by two movable arms. A real time spectrum analyser is used to process the Doppler signals. A water bath was used to perform an in vitro calibration of the complete system and to adjust the registration of the Doppler sample volume with the echo picture. Several possible inaccuracies in vessel diameter measurement are discussed and the mean of several caliper measurements described by Eik-Ness (1982) is used. Time Motion is thought to be the better method but is more complicated in practice.

Adult↗

Raised ankle/brachial pressure index in insulin-treated diabetic patients.

The ankle/brachial blood pressure index (A/B PI) is important in the vascular laboratory assessment of peripheral vascular disease. However it is falsely elevated in diabetes, hence underestimating the true severity of disease. We have therefore examined the influence of diabetes on the A/B PI in 2092 patients, 538 with diabetes, all referred for evaluation of peripheral vascular disease. The prevalence of a raised A/B PI (greater than or equal to 1.5) in insulin-treated patients (18.3%) was much higher (p less than 0.001) than that in both non-insulin-treated diabetic patients (4.5%) and patients with no diabetes (2.8%). Insulin-treated patients with a duration of diabetes of greater than 30 years had a higher prevalence of raised A/B PI than those with a duration of less than or equal to 9 years. No significant age effects were seen.

Ankle↗

The computer as a tool in the diagnosis and treatment of peripheral vascular disease.

The application of a mini computer to a routine diagnostic vascular laboratory has been assessed in over 4,500 patients over a period of 5 years. The laboratory functions to provide diagnosis of peripheral vascular disease. The computer functions are: scientific, in which it is used for modelling the arterial system and for applying diagnostic algorithms using haemodynamic signals re-input data, data base management, in which it is used to store clinical histories, the results of haemodynamic tests, and data for reconstructive surgery, and administrative, in which it is used for laboratory booking, report generation and management and workload statistics.

Blood Flow Velocity↗