Search PubMed⌕ Search

Biomedical subjects

U Nicolini

Publications and source records attributed to U Nicolini.

At least 145 records · Page 8Linked to original sources

Difficulties in "real-time" ultrasound diagnosis of fetal urological anomalies.

In the fetus of a diabetic woman, at the 24th week of pregnancy urological anomalies (cystic kidney malformations) were found with real-time ultrasound. At the 34th week these findings were confirmed and interpreted to be due to a lower urinary obstruction. Therefore a preterm Caesarean section was performed. In the newborn the left multicystic kidney was removed. The indications for the US screening in pregnancy and difficulties in the interpretation of urological findings of fetal and newborn ultrasonograms are discussed.

Female↗

Effectiveness of routine ultrasound in screening congenital defects.

During one year 26 cases of fetal malformations were diagnosed by means of ultrasound alone at the 1st Department of Obstetrics and Gynaecology of the University of Milano. Frequency of congenital defects first detected in the Centre was 5.6% which can be estimated to be approx. 25% of the anomalies detectable at birth in an unselected population. The total number of congenital defects detected was 31. A wrong diagnosis was done in two suspected cephaloceles resulted to be a cystic hygroma of the neck and a nuchal cephaloematoma while a pleural effusion was misdiagnosed as a thoracic cyst. On the other hand a precise evaluation of diagnostic errors (false negatives) has not been possible. Most malformations not detected by scanning involved splanchnic organs rather than central nervous system (Tab. V). Ultrasonic procedures for measurement of fetal head and trunk could partly account for this result. Termination of pregnancy was performed in 4 cases and post-partum surgical correction in 3 (Tab. I). Antenatal diagnosis of fetal malformations should be then considered as a major end-point of routine US.

Amniotic Fluid↗

Perinatal management of exomphalos diagnosed in late pregnancy.

The intrauterine diagnosis of a huge exomphalos, which was aspirated by transuterine puncture 1 hour prior to caesarean section, is reported. The authors emphasize that this prenatal procedure is able to minimize the risk of rupturing the exomphalos sac.

Adult↗

Malformation of the fetal urinary system. A new obstetrical approach.

A case of prenatal diagnosis of prune belly syndrome is described. The ultrasound presumptive diagnosis was that of low urinary tract obstruction. Neonatal mortality with this defect is estimated to be approximately 50% and mainly arises from kidney damage. In order to achieve further information for obstetrical management, intrauterine bladder evacuation was performed and fetal urine production rate monitored by ultrasound. This approach is proposed as a new method of diagnosis and temporary therapy for those fetal malformations determining urinary stasis.

Abdominal Muscles↗

Intravenous glucose infusion in labor does not affect maternal and fetal acid-base balance.

OBJECTIVE: This prospective randomized trial compares the effects of a 5% glucose solution or no infusion during labor on glucose levels, pH, pO2, pCO2, and base excess (BE) of normal pregnant women in early labor and at delivery, and on fetal cord blood. METHODS: Forty-three women were randomized to glucose infusion and 38 were controls. RESULTS: Starting glucose levels were independent from the fasting state. When no glucose supplementation was given, the labor itself was associated with a reduction of mean pH (from 7.42 to 7.36, P = 0.00001), mean pCO2 (from 25.7 to 24.4 mm Hg, P = 0.04), and mean BE (from -6.3 to -9.8 mEq/L, P = 0.00001), and an increase of capillary glucose (from a mean of 83 to 105 mg/dL, P = 0.00001). Infusions of glucose did not significantly alter maternal acid-base balance at delivery. pH, PO2, pCO2, and BE were similar in arterial and venous cord blood of both groups. No variables correlated with cord blood glucose levels or with glucose vein-artery difference. CONCLUSIONS: We conclude that a 5% glucose infusion does not significantly reduce maternal acidemia associated with vaginal delivery and therefore its use cannot be recommended, since maternal glucose is largely available during labor. Intrapartum glucose infusions do not alter the acid-base balance, when the fetus is well oxygenated.

Acid-Base Equilibrium↗

The safety of fetoscopy: (I). Effect of umbilical vessel puncture on the fetal heart rate and cord histology.

The fetal heart rate (FHR) was continuously monitored during 42 umbilical vessel punctures performed at the placental insertion of the cord in 24 diagnostic fetoscopies in which pure fetal blood was obtained. In only one patient did a deceleration first appear during puncture and aspiration of fetal blood. In two patients decelerations preceded fetoscopy and in two others they began during the fetoscopy but before puncture of an umbilical vessel. In 19 patients, the FHR did not change at all during the procedure. Fetal haemorrhage after sampling was either absent or minimal. Six pregnancies were terminated because a positive diagnosis had been made and 18 healthy babies were born. Umbilical cords were examined after 7 terminations of pregnancy and after 6 deliveries. In the former group the puncture could just be seen with the naked eye and the needle track was demonstrated histologically in 6. No traces of the puncture or other abnormalities were found in the cords after delivery. Fetal blood sampling from umbilical cord vessels, particularly at the placental insertion of the cord, is the technique of choice since pure fetal blood can be obtained without increasing the risk of fetoscopy.

Blood Specimen Collection↗

Vibroacoustic stimulation is not associated with sudden fetal catecholamine release.

The safety of vibroacoustic stimulation (VAS), which produces marked changes in fetal heart rate, movements and behavioural state, remains unclear. In order to determine whether VAS is associated with catecholamine release, we measured plasma noradrenaline and adrenaline in 13 appropriately grown normoxaemic fetuses between 28 and 40 weeks gestation immediately before and 60 and 75 s after VAS. Over this time interval, VAS is known to increase fetal heart rate. There was no significant change in either noradrenaline (median change = +0.06 ng/ml, P = 0.26) or adrenaline levels (median change = +0.03 ng/ml, P = 0.4). This study suggests that sympathoadrenal activation is not part of the fetal response to VAS. These findings do not support the recent suggestion that VAS may be deleterious to the fetus by provoking sudden release of catecholamines.

Acoustic Stimulation↗

Insulinlike growth factor 1 in controls and growth-retarded fetuses.

OBJECTIVES: To establish a reference range of insulinlike growth factor 1 (IGF-1) values in normal fetuses and to assess whether intrauterine growth retardation is associated with increased or decreased IGF-1 levels. METHODS: Retrospective analysis of blood samples collected from 64 fetuses who underwent blood sampling at 18-38 weeks' gestation was performed: 40 fetuses, who were considered controls, were appropriately grown for gestational age and were found unaffected by the condition for which they were tested; the remainder (n = 24) underwent fetal blood sampling to assess fetal karyotype and acid-base balance following ultrasonic diagnosis of intrauterine growth retardation. (In this group, 8 survived, and 16 died during the perinatal period). IGF-1 was measured using a radioimmunoassay after acid-ethanol extraction in order to avoid interference by the binding proteins. All samples from controls and growth-retarded fetuses were measured using the same batch, and the intra-assay coefficient of variation of the test ranged from 4.1 to 6.1%. RESULTS: In control fetuses, IGF-1 serum levels increased linearly with gestational age. In growth-retarded fetuses, IGF-1 levels were not significantly different from the reference range (median Z-score -0.3; range -4.4 to 291) and did not correlate with fetal size, hematocrit, and acid-base balance values. There was a significant difference in IGF-1 and pH values when the fetuses were divided into two groups based on the perinatal outcome: those who survived had values of IGF-1 mostly within the normal range, whereas the fetuses who died in utero or postnatally had significantly decreased pH and elevated IGF-1 values (median Z-score 2.1; 95% confidence interval 0.4-13.9; p = 0.04). CONCLUSIONS: This study confirms previous observations that IGF-1 levels parallel the increase in fetal size which occurs with advancing gestation. Increased levels of IGF-1 may indicate a terminal process in the fetal adaptation to placental failure.

Case-Control Studies↗

Fetal and maternal white cells and B- and T-lymphocyte subpopulations in pregnant women with recent infection.

OBJECTIVE: To study maternal and fetal white cell counts, B- and T-lymphocyte subpopulations in pregnant women with evidence of recent infection. METHODS: Thirty-seven pregnant women with recent infection and 38 controls were studied. All were referred for fetal blood sampling to exclude congenital infection, or to perform fetal chromosome analysis. There were 16 infected fetuses: 9 cytomegalovirus (CMV), 4 rubella, and 3 toxoplasmosis. Maternal and fetal blood was taken and white cell counts, the percentage of CD3+, CD4+, CD8+, CD56+, HLADR+CD3+ T-lymphocyte subpopulations and CD19+ B lymphocytes were measured. RESULTS: The percentage of CD3+, CD8+, and HLADR+CD3+ lymphocytes were significantly higher in infected mothers compared to controls, while CD19+ and the CD4+/CD8+ ratio were lower. Infected mothers carrying infected fetuses had significantly lower white blood cell counts compared to those infected mothers without fetal infection. The percentage of HLADR+CD3+ T lymphocytes was significantly higher and the CD4+/CD8+ ratio lower in infected fetuses compared to controls and noninfected fetuses of infected mothers. Abnormal CD4+/CD8+ ratios and/or increased HLADR+CT3+ T lymphocytes were found in 8 of 10 fetuses with structural abnormalities and/or hematological/biochemical signs of systemic damage, and in 7 of 27 without (RR = 3.1, 95% CI = 1.5-6.3). CONCLUSION: Both infected fetuses and their mothers have significant identifiable changes in white cell counts and T-lymphocyte subpopulations compared to controls. These tests may help in diagnosing maternal and fetal infection.

B-Lymphocytes↗

Carbohydrate metabolism in fetuses with Rh alloimmunization.

Glucose, insulin, glucagon and fructosamine were measured in the plasma of control (n = 34) and of Rh fetuses (n = 22) before the first and subsequent transfusion. Prior to treatment, Rh fetuses, compared to controls, had raised concentrations of glucose (p = 0.01), glucagon (p = 0.04) and fructosamine (p = 0.004). Fetal insulin levels were not significantly different. Before subsequent transfusion, despite correction of anemia, Rh fetuses were clearly hyperinsulinemic even after correction for gestation (p = 0.002) and had low glucagon concentrations (p = 0.01) when compared with values at the first transfusion. This metabolic milieu appears similar to that of fetuses of diabetic mothers which have increased plasma glucose and insulin during most of the last third of gestation.

Blood Glucose↗

Changes in blood flow velocity waveforms following fetal blood sampling.

The umbilical artery, aorta, and middle cerebral artery pulsatility indices were investigated by pulsed Doppler ultrasound in 73 fetuses at 18-37 weeks of gestation, before and after fetal blood sampling performed either at the placental cord insertion (n = 46) or at the intrahepatic vein (n = 27). At the end of the procedure, after randomization, 35 fetuses were infused amounts of normal saline equal to the blood volume withdrawn, and 38 fetuses served as controls. Following blood sampling, the umbilical artery pulsatility indices decreased both in controls (p = 0.004) and in the saline group (p = 0.006). The middle cerebral artery velocity waveforms exhibited similar changes only in controls (p = 0.01), and no changes in fetal heart rate and aortic pulsatility indices were recorded in either group. The changes in blood flow velocity waveforms did not correlate with gestational age and the blood volume sampled, and were similar whether the site of sampling was the placental cord insertion or the intrahepatic vein. In 10 acidemic and/or hypoxemic fetuses, pulsatility indices in the umbilical and middle cerebral arteries were not modified by the blood sampling procedure. The release of vasoactive substances is most likely the cause of diminished vascular resistances following fetal blood sampling. Hypoxemic/acidemic fetuses may fail to mount a normal vasodilative response to needle puncture.

Aorta↗

Varying clinical course of large placental chorioangiomas. Report of 3 cases.

Three cases of placental chorioangiomas, from 6.5 to 10 cm in diameter, were diagnosed prenatally by ultrasound and color Doppler imaging at 21-34 weeks of gestation. In 1 case, due to fetal hydrops and maternal 'mirror syndrome', immediate delivery of a neonate, who was severely anemic, thrombocytopenic and had consumption coagulopathy, was required. In the other 2 pregnancies, conservative management was possible, once fetal cardiac failure and anemia were ruled out by the combination of fetal blood sampling and serial echographic and Doppler investigations.

Adult↗