Search PubMed⌕ Search

Biomedical subjects

Thomas Flohr

Publications and source records attributed to Thomas Flohr.

43 records · Page 3Linked to original sources

Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography.

In computed tomography (CT), selection of a convolution kernel determines the tradeoff between image sharpness and pixel noise. For certain clinical applications it is desirable to have two or more sets of images with different settings. So far, this typically requires reconstruction of several sets of images. We present an alternative approach using default reconstruction of sharp images and online filtering in the spatial domain allowing modification of the sharpness-noise tradeoff in real time. A suitable smoothing filter function in the frequency domain is the ratio of smooth and original (sharp) kernel. Efficient implementation can be achieved by a Fourier transform of this ratio to the spatial domain. Separating the two-dimensional spatial filtering into two subsequent one-dimensional filtering stages in the x and y directions using a Gaussian approximation for the convolution kernel further reduces computational complexity. Due to efficient implementation, interactive modification of the filter settings becomes possible, which can completely replace the variety of different reconstruction kernels.

Algorithms↗

Non-invasive demonstration of coronary artery anomaly performed using 16-slice multidetector spiral computed tomography.

Coronary artery anomalies are some of the most confusing, neglected topics in cardiology. Presently, no techniques are able to routinely screen those morphological alterations which can create potentially life-threatening complications, especially in young healthy subjects. Many efforts have been made to non-invasively image the coronary arteries using magnetic resonance, electron beam computed tomography, and recently multidetector computed tomography (MDCT). Even though interesting results have been reported, these techniques have hardly become an adequate substitute for conventional catheter coronary angiography. A new generation of MDCT scanners with 16 arrays of detectors and a higher temporal and spatial resolution have recently been introduced. We report a case of an anomalous coronary artery origin documented using a 16-slice MDCT scanner.

Coronary Angiography↗

Spatial domain image filtering in computed tomography: feasibility study in pulmonary embolism.

Our objective was to evaluate the clinical feasibility of spatial domain filtering as an alternative to additional image reconstruction using different kernels in chest CT. Spatial domain filtering generates smooth images from sharp images and thus avoids the need for additional reconstructions when two sets of images are desired. Forty adult patients with clinical suspicion of pulmonary embolism were examined utilizing multi-slice CT (Somatom Volume Zoom, Siemens, Germany). Derived from thin collimated source images (100 mAs, collimation 4x1 mm, rotation time 0.5 s, table speed 7 mm/rotation), two sets of images [effective slice thickness (S(eff)) 5 mm, reconstruction increment (RI) 5 mm) were generated using lung (Siemens B50) and soft tissue (Siemens B30) kernels. Additionally, B50 images were filtered in the spatial domain, producing images largely equivalent to B30 images. Firstly, diagnostic accuracy was assessed on spatial domain filtered images regarding central, segmental, and subsegmental pulmonary embolism. In a second step, diagnostic accuracy was assessed for the initially reconstructed B30 images. The results were compared with thin axial slices from the same data set, which were considered as the gold standard in this respect (S(eff )1.25 mm, RI 0.8 mm; B30). Initially reconstructed B30 slices and secondary filtered images were rated for subjective image quality, using a five-point scale (1=excellent, 2=good, 3=moderate, 4=poor, 5=non-diagnostic). Finally, quantitative measurements were assessed using the region of interest (ROI) methodology. In 20 patients pulmonary embolism was proven. Five-millimeter images revealed 10 of 10 central emboli, 18 of 19 segmental thrombi, and 18 of 20 emboli on the subsegmental level. Pulmonary embolism was excluded in 18 of 20 subjects, and in 2 patients a false-positive result was obtained in subsegmental arteries. These findings were concordant for reconstructed and filtered images. Quantitative density measurements provided comparable Hounsfield units in this respect. Subjective gradings of image quality, based on soft tissue settings, were 1.30 (+/-0.61) for reconstructed slices vs 1.35 (+/-0.62) for filtered images (weighted kappa coefficient 0.6117; 95% confidence intervals 0.3298-0.8935). Spatial domain filtering has proved to be feasible. Compared with conventional soft tissue reconstructions for central, segmental, and subsegmental pulmonary embolism, no significant difference in the diagnostic value of spatial domain filtered images was found. Online modifications of image sharpness and pixel noise in real time leads to a considerable reduction of processing time and cost saving for storage of CT images. Despite different data processing methods, thin effective slice thicknesses and overlapping reconstruction increments are mandatory for detailed CT analysis of pulmonary embolism on the segmental and subsegmental level.

Feasibility Studies↗

Segmented multiple plane reconstruction: a novel approximate reconstruction scheme for multi-slice spiral CT.

A new reconstruction scheme for multi-row spiral CT is described and results are presented. The spiral path is decomposed into small, overlapping segments which are used for a separate convolution and backprojection yielding a stack of segment images which contain only projection data of a partial scan (typically in the range of 20). These segment image stacks are, in a second step, reformatted to the requested image planes. In a third step, the reformatted segment images are added to obtain full images. The main benefit of the proposed algorithm is superior images quality. A 64-row dataset with a cone angle of 6.4 and a table feed of 80 mm per spiral turn has been reconstructed with excellent image quality. A filter direction for three-dimensional (3D) backprojection algorithms is suggested by investigating the limit where the partial scan size goes to zero.

Algorithms↗

Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Our objective was to evaluate image quality and radiation exposure of retrospectively ECG-gated multislice helical CT (MSCT) investigations of the heart with ECG-controlled tube current modulation. One hundred patients underwent MSCT scanning (Somatom VolumeZoom, Siemens, Forchheim, Germany) for detection of coronary artery calcifications. A continuous helical data set of the heart was acquired in 50 patients (group 1) using the standard protocol with constant tube current, and in 50 patients (group 2) using an alternative protocol with reduced radiation exposure during the systolic phase. The standard deviations (SD) of predefined regions of interest (ROIs) were determined as a measure of image noise and were tested for significant differences. There was no significant difference between group 1 and group 2 with respect to image noise. Radiation exposure with and without tube current modulation was 1.0 and 1.9 mSv ( p<0.0001), respectively, for males and 1.4 and 2.5 mSv ( p<0.0001), respectively, for females; thus, there was a mean dose reduction of 48% for males and 45% for females, respectively. The ECG-controlled tube current modulation allows significant dose reduction when performing retrospectively ECG-gated MSCT of the heart.

Calcinosis↗

Molecular monitoring of residual disease using antigen receptor genes in childhood acute lymphoblastic leukaemia.

Immunoglobulin (Ig) and T-cell receptor (TCR) gene rearrangements are assumed to be unique 'fingerprint-like' sequences for each acute lymphoblastic leukaemia (ALL). Various clonal Ig/TCR gene rearrangements can be identified at diagnosis in virtually all childhood ALL patients, representing molecular targets for detection of minimal residual disease (MRD) during follow-up analysis. The usage of at least two MRD-PCR targets per patient generally ensures high sensitivity (</=1:10(4) normal cells) and prevents false-negative results owing to ongoing or secondary rearrangements.MRD monitoring in childhood ALL employing Ig/TCR gene rearrangements as PCR targets has significant prognostic value. This is particularly powerful for evaluation of early treatment response and consequently can be used for improved therapy stratification. Prolonged continuous MRD monitoring might be important for patients at intermediate or high risk of relapse. MRD monitoring in second complete remission identifies patients with excellent drug sensitivity and predicts outcome after stem cell transplantation.

Child↗

Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm.

RATIONALE AND OBJECTIVES: To evaluate the reconstruction interval dependent bandwidth of the coronary calcium score, considering different methods of image reconstruction and quantification of coronary calcifications. MATERIALS AND METHODS: Seventy-five patients underwent coronary calcium scoring by use of retrospectively ECG-gated multislice spiral CT. In all patients overlapping and nonoverlapping image reconstruction was performed every 10% of the RR-interval. Coronary calcium score was calculated for every reconstructed image series using the Agatston score and a volumetric scoring method. In 25 patients the analysis was performed twice to determine the reconstruction interval dependent intraobserver variability. RESULTS: For nonoverlapping image reconstruction the median of the calcium score determined by the Agatston method ranged from 125.8 to 216.2 and from 166.9 to 211.7 for the volumetric scoring method. For overlapping image reconstruction the corresponding values ranged from 91.6 to 160.5 for the Agatston score and 128.3 to 175.3 for the volumetric calcium score. Reconstruction interval dependent median (mean) variation of the coronary calcium score ranged from 24.1 (45.5)% for nonoverlapping image reconstruction using the Agatston score to 17.5 (25.2)% utilizing a volumetric calcium score with overlapping image reconstruction. There was no statistical significant (P< 0.05) difference between the different methods. Intraobserver variability for the different image reconstruction intervals ranged from 0.78% to 21.51%. The least intraobserver variability was found for overlapping image reconstruction during the diastole using the volumetric scoring method. CONCLUSIONS: Diastolic image reconstruction at 50% or 60% of the RR-interval is recommendable for retrospectively ECG-gated multislice spiral CT. Volumetric calcium scoring and overlapping image reconstruction are beneficial to reduce the variation of the coronary calcium score.

Adult↗