Optimization of MDCT of the wrist to achieve diagnostic image quality with minimum radiation exposure.

OBJECTIVE: This study tests various acquisition and reconstruction protocols for MDCT of the wrist to determine the optimal protocol for obtaining diagnostic image quality with minimal radiation exposure. MATERIALS AND METHODS: Thirty anatomic specimens were examined with an MDCT collimation of 4.0 x 1.0 mm and 2.0 x 0.5 mm (80, 120, and 140 kV; 80, 100, 130, 160, and 200 mA; rotation time, 0.5 0.75, 1.0 sec; pitch, 1.0, 1.3, 1.5, and 2.0). Coronal images were reconstructed using a slice thickness of 0.5, 1.0, and 2.0 mm with 60% overlap. Three observers evaluated all images independently for gross and fine anatomic detail. Diagnostic confidence was tested using Shrout-Fleiss intraclass correlation coefficients. Interobserver agreement was assessed by Kappa statistics and the Kruskal-Wallis test. RESULTS: Fine anatomic detail was best presented in 0.5-mm or 1.00-mm reconstructions based on a 2.0 x 0.5 mm acquisition. A rotation time of > or = 0.75 sec resulted in fewer artifacts; a significant dose reduction was achieved with 80 kV and 100 mA at the expense of somewhat increased noise, but without significant loss of anatomic detail in bone presentation. Artifacts were tolerable with a pitch of 1.5 or less. CONCLUSION: MDCT at the described optimal settings allows significant dosage reduction without sacrificing image quality. An acquisition and reconstruction thickness of 0.5 mm results in the best depiction of anatomic detail. A reconstruction thickness of 1.0 mm with a reconstruction interval of 0.5 mm represents a good trade-off between noise and resolution when using low-dose protocols.

Aged↗

Flat-panel detector computed tomography for the assessment of coronary artery stents: phantom study in comparison with 16-slice spiral computed tomography.

PURPOSE: The evaluation of coronary artery stents is a major limitation of cardiac multislice spiral computed tomography (MSCT). The development of flat-panel detector computed tomography (FPCT) with truly isotropic spatial resolution may overcome this limitation. Thus, we evaluated the use of FPCT in comparison to MSCT for the assessment of coronary artery stents. MATERIAL AND METHODS: Eight different coronary artery stents with a diameter of 3 mm each were placed in a static chest phantom. The phantom was positioned in the CT gantry at angles of 0 degrees , 45 degrees , and 90 degrees toward the z-axis and examined with the prototype of a FPCT (Siemens, Forchheim, Germany) and a commercially available 16-detector row MSCT (Sensation 16, Siemens). Slice thickness was 0.25 mm with FPCT whereas for MSCT, an effective slice thickness of 1 mm with a reconstruction increment of 0.5 mm was used. Image quality was assessed visually using a 5-point grading scale. Stent diameters were measured and compared using a repeated-measures analysis of variance. RESULTS: When compared with MSCT, artificial lumen reduction was significantly less using FPCT. On average the visible stent lumen was reduced by 16.1% with FPCT, whereas the mean of the lumen reduction was 47.2% with 16-detector row MSCT. Visible lumen diameter as well as image noise significantly increased using FPCT (P < 0.001). With FPCT delineation of the different stent struts became possible. CONCLUSION: FPCT proved to be superior when compared with 16-detector row MSCT for the in vitro assessment of coronary artery stents. Improved spatial resolution allows for a detailed assessment of the coronary artery stent lumen.

Coronary Angiography↗

Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.

Our objective was to evaluate the image quality of a 16-slice CT system with a rotation time of 375 ms in the assessment of coronary arteries. One hundred patients underwent iodine-enhanced CT coronary angiography within a single breath hold. Images were reconstructed in diastole, 300, 350, 400, 450, 500 and 550 ms prior to the onset of the next R-wave using absolute reverse retrospective ECG gating. The 15 coronary segments of the AHA classification were consensually reviewed by two radiologists. On the whole, best quality imaging was obtained with reconstruction intervals of -350 ms and -400 ms in high percentages of each segment (P<0.0001). Only 6.2% of the arteries with a diameter greater than or equal to 1.5 mm were not assessable because of extensive calcifications (3.9%), cardiac motion artifacts (1.9%), lack of enhancement (0.2%) and stent artifacts (0.3%). In patients with a heart rate above 70 beats per minute, the percentage of assessable segments decreased to 88%, while at a lower heart rate it increased to 95%. In 61% of the patients, all segments were assessable. In conclusion, this generation of CT technique may allow visualization of coronary arteries with a low percentage of non-assessable segments.

Adult↗

Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.

The aim of this technical investigation was the detailed description of a prototype flat panel detector computed tomography system (FPCT) and its initial evaluation in an ex vivo setting. The prototype FPCT scanner consists of a conventional radiographic flat panel detector, mounted on a multi-slice CT scanner gantry. Explanted human ex vivo heart and foot specimens were examined. Images were reformatted with various reconstruction algorithms and were evaluated for high-resolution anatomic information. For comparison purposes, the ex vivo specimens were also scanned with a conventional 16-detector-row CT scanner (Sensation 16, Siemens Medical Solutions, Forchheim, Germany). With the FPCT prototype used, a 1,024x768 resolution matrix can be obtained, resulting in an isotropic voxel size of 0.25x0.25x0.25 mm at the iso-center. Due to the high spatial resolution, very small structures such as trabecular bone or third-degree, distal branches of coronary arteries could be visualized. This first evaluation showed that flat panel detector systems can be used in a cone-beam computed tomography scanner and that very high spatial resolutions can be achieved. However, there are limitations for in vivo use due to constraints in low contrast resolution and slow scan speed.

Foot Bones↗

Distinct gene expression profiles determine molecular treatment response in childhood acute lymphoblastic leukemia.

Treatment resistance, as indicated by the presence of high levels of minimal residual disease (MRD) after induction therapy and induction consolidation, is associated with a poor prognosis in childhood acute lymphoblastic leukemia (ALL). We hypothesized that treatment resistance is an intrinsic feature of ALL cells reflected in the gene expression pattern and that resistance to chemotherapy can be predicted before treatment. To test these hypotheses, gene expression signatures of ALL samples with high MRD load were compared with those of samples without measurable MRD during treatment. We identified 54 genes that clearly distinguished resistant from sensitive ALL samples. Genes with low expression in resistant samples were predominantly associated with cell-cycle progression and apoptosis, suggesting that impaired cell proliferation and apoptosis are involved in treatment resistance. Prediction analysis using randomly selected samples as a training set and the remaining samples as a test set revealed an accuracy of 84%. We conclude that resistance to chemotherapy seems at least in part to be an intrinsic feature of ALL cells. Because treatment response could be predicted with high accuracy, gene expression profiling could become a clinically relevant tool for treatment stratification in the early course of childhood ALL.

Adolescent↗

Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch.

A new 3D reconstruction scheme, weighted filtered backprojection (WFBP) for multirow spiral CT based on an extension of the two-dimensional SMPR algorithm is described and results are presented. In contrast to other 3D algorithms available, the algorithm makes use of all available data for all pitch values. The algorithm is a FBP algorithm: linear convolution of the parallel data along the row direction followed by a 3D backprojection. Data usage for arbitrary pitch values is maintained through a weighting scheme which takes into account redundant data. If proper row weighting is applied, the image quality is superior to the image quality of the SMPR algorithm.

Algorithms↗

Advances in cardiac CT imaging: 64-slice scanner.

BACKGROUND: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. MATERIALS AND METHODS: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. RESULTS: ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. CONCLUSIONS: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.

Calcinosis↗

Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries.

In the present study, we tested the ability of multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI) to identify and retrospectively characterize atherosclerotic lesions in human ex vivo coronary arteries. Thirteen ex vivo hearts were studied with MDCT and MRI. MDCT-images were obtained with an isotropic voxel size of 0.6mm(3). MR images were obtained with an in-plane resolution of 195 microm and 3mm slice thickness. All images were matched with histopathology sections. For both modalities, the sensitivity for the detection of any atherosclerotic lesion was evaluated, and a retrospective analysis of plaque morphology according to criteria defined by the American Heart Association (AHA) was performed. At histopathology, 28 atherosclerotic lesions were found. 21 and 23 of these lesions were identified by MDCT and MRI, respectively. Both modalities detected a small number of false-positive lesions. After retrospective matching with histopathology, MDCT as well as MRI were able to differentiate typical morpholocigal features for fatty, fibrous or calcified plaque components. Using the information presented in this study, in vivo coronary artery wall imaging using MDCT as well as MRI could be facilitated and supported for future investigations on this subject.

Adult↗

Optimization of ex vivo CT- and MR- imaging of atherosclerotic vessel wall changes.

OBJECTIVE: To optimize a methodology for ex vivo imaging of atherosclerotic vessel wall changes using multidetector-row computed tomography (MDCT) and multi-contrast magnetic resonance imaging (MRI). METHODS: In phantom studies and studies on intact ex vivo porcine and human hearts, various filling mixtures of MDCT and MRI contrast agents have been evaluated, to enable filling and distension of the coronary arteries for optimal visualization of atherosclerotic vessel wall changes with both techniques. Various proportions of methyl cellulose, iodine-containing CT contrast agent and paramagnetic MR contrast agent containing iron-oxide particles have been tested. Imaging parameters have been optimized for high resolution plaque imaging using a four detector-row CT scanner and a 1.5 T MR system. RESULTS: Phantom studies and studies on ex vivo porcine and human hearts demonstrated optimal proportion of methyl cellulose and CT contrast agent to be 98% vs. 2%, and 75% vs. 25% of methyl cellulose vs. MR contrast agent, respectively. These proportions provided optimal opacification of the vessel lumen in the MDCT images with 250 Hounsfield Units, and good signal suppression within the vessel lumen in the MR images, resembling in vivo imaging techniques. After retrospective matching with histopathology, atherosclerotic lesions of the human ex vivo specimens could be identified on MRI and MDCT images. CONCLUSION: Using an optimized mixture of methyl cellulose, MDCT and MRI contrast agents, visualization of atherosclerotic vessel wall changes is feasible, and applicable to various ex vivo models.

Aged↗

Protein phosphatase inhibitor-1 mRNA expression correlates with neoplastic transformation of epithelial liver cells and progression of hepatocellular carcinomas.

Protein phosphatase inhibitor-1 plays an important role in the regulation of glycogen metabolism through inhibition of protein phosphatase-1 activity, and it has been implicated in the regulation of cell growth. Using real-time quantitative RT-PCR, we studied the mRNA expression of inhibitor-1 in hepatocellular carcinomas induced in rats by oral administration of N-nitrosomorpholine, and in a non-tumorigenic liver cell line (C1I), that stores glycogen in excess during early passages. In late passages, glycogen is gradually lost concomitant with cell transformation. Our in vitro model included a tumorigenic subline of C1I cells that was obtained by chemically-induced neoplastic transformation using N-methyl-N'-nitro-N-nitrosoguanidine (C1Ict), and does not store glycogen, as well as Morris hepatoma 3924A (MH3924A) cells. We found that in hepatocellular carcinomas, in the late glycogen-poor passages (C1I(late)), and in the tumorigenic subline (C1Ict) of C1I cells, and in MH3924A cells the mRNA expression of inhibitor-1 is significantly increased. This increase in expression varied from 15 to 290-fold of that observed in normal liver. In contrast, in the early glycogen-storing passage of C1I cells (C1I(early)) the level of inhibitor-1 mRNA was found to be slightly less than that of normal liver. Inhibitor-1 mRNA levels correlated with the degree of differentiation of HCCs. These results indicate that the expression of inhibitor-1 mRNA is tightly linked to tumor progression and to the process of liver cell transformation in vitro and is inversely correlated with the glycogen content of the cell.

Administration, Oral↗

Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain.

The aim of this study was to investigate the accuracy of multidetector-row cardiac CT (MDCT), calcium scoring (Ca-Sc), and MDCT coronary angiography (MD CTA) in the assessment of coronary atherosclerosis. Thirty-eight patients underwent invasive coronary angiography (CA) and MDCT (collimation 4x1 mm, pitch 1.5 mm, TI 500 ms, 120 kV, 300 mAs, and retrospective ECG-gating). Calcium scoring was calculated for the total coronary artery territory and for RCA, LCA, and LCX separately. The MD CTA served to assess the degree and the localization of stenoses. All findings were compared to invasive coronary angiography. Approximately 68.4% (390 of 570) of all coronary segments could be visualized by MDCT. Correlation coefficient for MD CTA and CA amounted to r=0.58, showing distinct differences for the individual segments. Proximal segments generally showed better correlation (range 0.81-0.77) than medial segments (range 0.91-0.20), distal segments (range 0.55-0.04), or side branches (range 0.76-0.00). Patients with hemodynamically relevant (>75%) stenoses were detected by MD CTA with 72.2% sensitivity (13 of 18) and 100% specificity (20 of 20). For Ca-Sc sensitivity ranged between 94.7% (17 of 18) and 66.7% (12 of 18), specificity between 20% (4 of 20) and 80% (16 of 20) respectively, depending on the prevailing cutoff value. Combination of both methods led to 83.3% sensitivity (15 of 18) and 100% specificity (20 of 20), reaching no level of significance as compared with Ca-Sc (p=0.73) or MD CTA (p=0.23) alone. Calcium scoring as a single method showed highest sensitivity in the detection of coronary atherosclerosis but at the expense of low specificity. In patients with no or moderate calcifications, combination with MD CTA helped to distinctly increase specificity and NPV.

Adult↗

Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating.

The aim of this study was to reduce radiation exposure in multislice CT (MSCT) coronary artery calcium screening using different tube settings, and to determinate its impact on the detection and quantification of coronary artery calcification. Forty-eight patients underwent routine MSCT coronary artery calcium scoring (Somatom VolumeZoom, Siemens, Forchheim, Germany) with retrospective ECG-gated data acquisition. Scanning was performed with a 4 x 2.5-mm collimation. In each patient data acquisition was performed twice using tube settings of 120 kVp with 133 mAs (protocol 1) and of 80 kVp with 300 mAs (protocol 2). Together with the 80-kVp protocol additional online ECG-related tube current modulation (ECG pulsing) was used. Three-millimeter overlapping slices (increment 1.5 mm) were calculated for each data set. Semi-automated calcium quantification was performed calculating absolute Ca-hydroxylapatite mass. In addition to patient examinations, the radiation exposure for both protocols was evaluated using computed tomography dose index (CTDI) phantom measurements. Protocol 2 showed a significantly lower patient radiation exposure than protocol 1 (0.72 vs 2.04 mSv; p<0.0001). The CTDI phantom measurements revealed a 65% reduction of radiation dose. Calcium scoring results of both protocols showed a high correlation ( r=0.99; p<0.0001) for absolute Ca-Hydroxylapatite mass measurements. Using 80-kVp protocols patient radiation exposure can be significantly reduced in MSCT coronary artery calcium screening without affecting the detection and quantification of coronary artery calcification; therefore, this technique should be used with retrospective ECG-gated cardiac CT examinations in patients with regular sinus rhythm.

Calcinosis↗

Multislice CT angiography.

The introduction of multislice CT into clinical radiology constitutes a quantum leap that significantly widens the scope of vascular CT imaging. The advances over conventional spiral CT have been quantitative, mainly in terms of increased image acquisition speed which provides unprecedented volume coverage and spatial resolution. Moreover, significant technical innovations, such as cardiac scanning capabilities, have brought about a qualitative shift towards applications that were thought to be beyond the scope of CT imaging. This way multislice CT offers a wealth of new opportunities for quickly and accurately diagnosing suspected vascular disease in all organ systems; however, as we move towards faster and faster image acquisition techniques, we are also facing new challenges that require development of novel strategies in order to take full advantage of the increased capabilities of multislice CT in its current form and future generations of CT scanners.

Angiography↗

Do segmented reconstruction algorithms for cardiac multi-slice computed tomography improve image quality?

PURPOSE: To evaluate segmented reconstruction algorithms for spiral multi-slice computed tomography (MSCT) that use data from two cardiac cycles to improve temporal resolution (tau) for imaging of the heart. MATERIALS AND METHODS: An initial group of 78 cardiac patients (heart rates [HR] = 63-167 beats per minute [bpm]) were imaged on a 4-slice, 500 ms gantry rotation time scanner (scanner 1). Images were reconstructed with a single-segment algorithm using data from one cardiac cycle with a reconstruction window of fixed length (tau = 250 ms). Images were also reconstructed with two variants of a multi-segment algorithm using data from two cardiac cycles where only one end of the reconstruction window was fixed and the other end was freely moveable to allow adjustment of tau according to HR: (1) "2-segment fixed start" with fixed start of reconstruction, (2) "2-segment fixed end" with fixed end of reconstruction (for both, tau = 125-250 ms). The resulting image sets were ranked from best to worst (1-3, respectively) in a side-by-side, blinded comparison by two independent readers. A second group of 26 patients (HR = 74-90 bpm) were imaged on a 12-slice, 420 ms gantry rotation time scanner (scanner 2). Data were reconstructed with a single-segment algorithm (tau = 210 ms) and a "2-segment fixed start" algorithm (tau = 105-210 ms) and image sets were ranked from best to worst (1-2, respectively). RESULTS: There was no clear evidence that any one technique is superior for imaging on scanner 1. Reader 1 ranked single-segment images the highest for all HRs, but statistically significant differences among the three algorithms were only found for the lowest HRs (< 80 bpm), where reader 1 preferred single-segment over "2-segment fixed end" techniques (p = 0.048). The highest rankings given by reader 2 varied according to HR: single-segment images were superior for lowest HRs, while "2-segment fixed start" images were superior for HRs > 80 bpm; none of these comparisons reached statistical significance. Improved performance of 2-segment reconstruction was found with scanner 2. Both readers ranked "2-segment fixed start" images the highest (p < 0.01). CONCLUSIONS: The added value of 2-segment cardiac reconstruction algorithms for spiral MSCT was not demonstrated for a 4-slice, 500 ms gantry rotation time scanner but shown to be beneficial for a 12-slice, 420 ms gantry rotation time scanner in the crucial HR range of 74-90 bpm.

Adolescent↗

Performance evaluation of a multi-slice CT system with 16-slice detector and increased gantry rotation speed for isotropic submillimeter imaging of the heart.

BACKGROUND: 4-slice CT scanners have shown limitations in clinical application for noninvasive coronary CT angiography (CTA). We evaluate advances in ECG-gated scanning of the heart and the coronary arteries with recently introduced 16-slice CT equipment (SOMATOM Sensation 16, Siemens, Forchheim, Germany). MATERIALS AND METHODS: The technical principles of ECG-gated cardiac scanning, scan parameters, and detector design of the new scanner are presented. ECG-gated scan and image reconstruction techniques and ECG-controlled dose modulation ("ECG pulsing") for a reduction of the patient dose are described, key parameters for image quality and simulation results presented, and phantom studies and initial patient experience discussed. The impact of reduced gantry rotation time (0.42 s) on temporal resolution and initial estimations of the patient dose are presented. RESULTS: Extensions of ECG-gated reconstruction algorithms used for 4-slice CT provide adequate image quality for up to 16 slices. For each detector collimation different slice widths are available for retrospective reconstruction with well-defined slice sensitivity profiles (SSPs). For coronary CTA the heart can be covered with 0.75 mm collimation within a 20-s breathhold. The best possible spatial resolution is 0.5 x 0.5 x 0.6 mm. For 0.42 s gantry rotation time, temporal resolution reaches its optimum (105 ms) at a heart rate of 81 bpm. Effective patient dose for coronary CTA is 4-5 mSv using ECG-pulsed acquisition. CONCLUSION: The clinical performance of coronary CTA by means of spatial resolution, temporal resolution and scan time is substantially improved with the evaluated 16-slice CT scanner. Also, display of smaller coronary segments and instent visualization are substantially improved.

Algorithms↗

Stimulation of endothelial nitric oxide synthase by proinsulin C-peptide.

There is increasing evidence for biological functions of human C-peptide. Recently, we have described that proinsulin C-peptide increases nutritive capillary blood flow and restores erythrocyte deformability in type 1 diabetic patients, whereas it has no such effect in non-diabetic subjects. The aim of the current study was to elucidate cellular mechanisms of this vasodilator effect in vitro by measuring the nitric oxide (NO)-mediated increase of cGMP production in a RFL-6 reporter cell assay and by demonstrating endothelial calcium influx with the Fluo-3 technique. C-peptide increased the release of NO from endothelial NO synthase (eNOS) in bovine aortic endothelial cells in a concentration- and time-dependent manner. At physiological concentrations of C-peptide, endothelial NO production was more than doubled (208+/-12% vs control; p<0.001). The NO release was abolished by the inhibitor of NO synthase N(G)-nitro-L-arginine or when Ca(2+) was removed from the medium superfusing the endothelial cells. C-peptide stimulated the influx of Ca(2+) into endothelial cells. No change in Ser-1179 phosphorylation of eNOS was detected after 6.6nM C-peptide. C-peptide did not change eNOS mRNA levels after 1, 6 or 24h. These data indicate that C-peptide is likely to stimulate the activity of the Ca(2+)-sensitive eNOS by increasing the influx of Ca(2+) into endothelial cells. We suggest that this effect may contribute to the increase in skin and muscle blood flow previously demonstrated in human in vivo.

Aniline Compounds↗

Improved coronary artery stent visualization and in-stent stenosis detection using 16-slice computed-tomography and dedicated image reconstruction technique.

OBJECTIVE: The aim of this study was to compare the visualization of different coronary artery stents and the detectability of in-stent stenoses during 4-slice and 16-slice computed tomography (CT) angiography in a vessel phantom. MATERIAL AND METHODS: Ten coronary stents were introduced in a coronary artery vessel phantom (plastic tubes with an inner diameter of 3 mm, filled with iodinated contrast material diluted to 220 Hounsfiled Units [HU], surrounded by oil [60 HU]). CT scans were obtained perpendicular to the stent axes on a 4-slice scanner (detector collimation 4x1 mm; table feed 1.5 mm/rotation, mAs 300, kV 120, medium-smooth kernel) and a 16-slice scanner (detector collimation 12x0.75 mm; table feed 2.8 mm/rotation, mAs 370, kV 120, reconstruction with a standard and an optimized sharp kernel). Longitudinal multiplanar reformations were evaluated regarding visible lumen diameters and intraluminal attenuation values. Additionally, the stents were scanned with the same parameters after implantation of 60% stenoses (HU 30). RESULTS: Using the same medium-smooth kernel reconstruction with 4-slice and 16-slice CT, there was a slight increase in the average visible lumen area (26% versus 31%) and less increase of average intraluminal attenuation values (380 HU versus 349 HU). Significant improvement of lumen visualization (54%, P<0.01) and attenuation values (250, P<0.01) was observed for the 16-slice scans using the sharp kernel reconstruction. In-stent stenoses could be more reliably identified (or ruled out) by 16-slice CT and sharp reconstruction kernel when compared with the other 2 methods. CONCLUSION: 16-slice CT using a dedicated sharp kernel for image reconstruction facilitates improved visualization of coronary artery stent lumen and detection of in-stent stenoses.

Coronary Angiography↗