Search PubMed⌕ Search

Biomedical subjects

T Sonobe

Publications and source records attributed to T Sonobe.

At least 55 records · Page 3Linked to original sources

Dependence of baroreceptor-mediated sympathetic outflow on biventricular assist device driving frequency.

To investigate the drive condition of the artificial heart from a neurophysiological point of view, the dynamic transduction characteristics of the baroreflex system were analyzed by means of sympathetic neurograms. Two pneumatically actuated ventricular assist devices were implanted as biventricular bypasses (BVBs) in adult mongrel dogs to compare the natural heart circulation and prosthetic circulation. After BVB pumping was initiated, the natural heart was electrically fibrillated. Renal sympathetic nerve activity (RSNA) was recorded to analyze sympathetic outflow. Coherence function between the arterial pressure and RSNA was calculated to evaluate the linearity of the baroreflex system. The largest peak coherency was observed when BVB was driven at the frequency of natural heart beat prior to electrical fibrillation, which suggests that the baroreflex system shows the largest linearity at this frequency. These results suggest the possibility that the natural heart beat frequency is the setting frequency at which the baroreflex system transfers the hemodynamic rhythm to the sympathetic outflow.

Animals↗

Mayer waves in dogs with total artificial heart.

To assess the effect of a total artificial heart (TAH) on the autonomic nervous system a power spectral analysis of the hemodynamics in a TAH animal was done by the maximum entropy method. Two pneumatically driven sac-type ventricular assist devices were implanted as total biventricular bypass (BVB) in adult mongrel dogs to compare the differences between natural heart and TAH. Once the BVB was pumping, the natural heart was electrically fibrillated to constitute the BVB-type TAH model. In the arterial pressure waveform in animals with TAH, respiratory waves were not changed (97.7 +/- 24.6%) though Mayer waves were significantly decreased (47.5 +/- 22.6%) compared with the animal with a natural heart. These results suggest that prosthetic hemodynamics in the TAH animal affect fluctuations in the cardiovascular system.

Animals↗

Estimation of the following cardiac output using sympathetic tone and hemodynamics for the control of a total artificial heart.

A sympathetic neurogram is potentially useful for the development of a real time total artificial heart (TAH) control system. We used sympathetic tone and hemodynamic derivatives to estimate the following cardiac output in acute animal experiments using adult mongrel dogs. Moving averages of the mean left atrial pressure and mean aortic pressure were used as parameters of the preload and afterload, respectively. Renal sympathetic nerve activity (RSNA) was employed as a parameter of sympathetic tone. Equations for the following cardiac output were calculated using multiple linear regression analysis of the time series data. A significant correlation was observed between the estimated and following measured cardiac output. These results suggest the potential usefulness of the sympathetic neurogram for the real time TAH automatic control system.

Animals↗

Cardiac-related sympathetic nerve activity during circulation with only the left ventricular assist device.

Circulatory maintenance with a left ventricular assist device (LVAD) alone during cardiac arrest until heart transplantation has been evaluated. To assess the effect on the autonomic nervous system, the sympathetic neurogram was analyzed by power spectrum and coherence function. LVAD were inserted between the left atrium and the descending aorta in seven adult mongrel dogs and ventricular fibrillation was induced electrically. Renal sympathetic nerve activity (RSNA) was detected by bipolar electrodes attached to the left renal sympathetic nerve. Values of squared coherence between the arterial pulse wave and RSNA were calculated. Under the condition of circulatory maintenance with only LVAD, coherence at the cardiac rhythm frequency was decreased, and coherence at the LVAD pumping rhythm frequency was increased. These results indicate that the arterial pulse wave observed during maintenance of the circulation with only LVAD contributed to the sympathetic neurogram.

Animals↗

Postganglionic sympathetic nerve activity with correlation to heart rhythm during left ventricular assistance.

In order to evaluate the effect of ventricular assist device (VAD) driving on the autonomic nervous system, sympathetic neurograms during left ventricular (LV) assistance were analyzed by power spectrum and coherence function. Our TH-7B pneumatically-driven sac-type VAD was used in seven adult mongrel dogs. VADs were inserted between the left atrium and the descending aorta. Renal sympathetic nerve activity (RSNA) was detected by use of bipolar electrodes attached to the left renal sympathetic nerve via a retroperitoneal approach. Values of squared coherence between the arterial pulse wave and RSNA were measured at the same frequency of cardiac and VAD pumping rhythms. During LV assistance, coherence at the cardiac rhythm frequency was decreased, and coherence at the VAD pumping rhythm frequency was increased. These results indicate that the arterial pulse wave, which was produced by the VAD assistance, contributed to postganglionic sympathetic nerve activity.

Animals↗

Spectral analysis of the renal sympathetic neurogram during left ventricular assistance.

To assess the effect of left ventricular assistance on cardiac-related sympathetic nerve activity, renal sympathetic nerve activity was analysed using power spectrum and coherence function. Our TH-7B pneumatically driven sac type Ventricular Assist Device (VAD) was used in the acute experiment of 7 adult mongrel dogs. VAD were inserted between the left atrium and the descending aorta as left heart bypass. RSNA was detected by use of the bipolar electrodes attached to the left renal sympathetic nerve. Values of squared coherence between the arterial pulse wave and RSNA were measured at the cardiac rhythm and VAD pumping rhythm. Before the left ventricular assistance, coherence at the cardiac rhythm and the pumping rhythm were 0.62 +/- 0.15, 0.23 +/- 0.18 (mean +/- SD), respectively. With the VAD pumping, these values became 0.09 +/- 0.05, 0.53 +/- 0.20, respectively. These results indicate that arterial pressure wave which was created by the VAD assistance contributed to the post ganglionic sympathetic activity.

Animals↗

Development and evaluation of the vibrating electromagnetically-driven artificial heart.

An vibrating electromagnetically driven univalved artificial heart was newly developed in our team. The fluid mechanical, hematological, and hemodynamical properties of this pump was evaluated in the moc circulation and animal experiments using adult goats. This vibrating electromagnetic (VEM) pump could generate more than 101/min with 10 Hz vibration, and could obtain the 2 kinds of flow and pressure patterns, such as constant peak and periodical peak patterns. The values of free Hb showed within acceptable values. We concluded that this pump is useful for totally implantable artificial heart.

Animals↗

TH-7B pneumatically driven sac-type ventricular assist device and drive system.

TH-7B pneumatically driven sac-type ventricular assist device and drive system including automatic control system were developed and evaluated in the chronic animal experiments. The blood-contacting surfaces of the blood pump are coated with either Cardiothane or Cardiomat. In the chronic experiments using adult goats, only one of fifteen goats showed sudden thrombus formation after 34 pumping days. No gross findings of thrombus formation were observed in any of the cases, except for a thin circular thrombus at the junction of the connectors and the sac of the blood pump. These results suggest that antithrombogenicity of this system was satisfactory for clinical use.

Animals↗

Development of the total artificial heart control system.

Sympathetic neurogram is potentially useful for the real time total artificial heart (TAH) control system. In this study, we used sympathetic tone and hemodynamic derivatives to prospect the following cardiac output in acute animal experiments using adult mongrel dogs. Moving averages of the mean left atrial pressure and mean aortic pressure were used as the parameters of the preload and afterload, respectively. Renal sympathetic nerve activity (RSNA) was also utilized as the parameter of the sympathetic tone. Equation which prospect the following cardiac output was calculated using the multiple linear regression analysis of the time series data in adult mongrel dogs. A significant correlation was observed between the prospective and following measured cardiac output. These results suggest the potential usefulness of the sympathetic neurogram for the real time TAH automatic control system.

Animals↗

Coherence function between sympathetic neurogram and arterial pulse wave in animal with total artificial heart.

To assess the influence of the total artificial heart replacement on autonomic nervous system, sympathetic neurogram was analyzed by power spectrum and coherence function. Two pneumatically driven sac-type ventricular assist devices were implanted as biventricular bypass (BVB) in adult mongrel dogs. After the BVB pumping, natural heart was electrically fibrillated to constitute the BVB type TAH model. Renal sympathetic nerve activity (RSNA) was recorded using the bipolar electrode attached to the left renal sympathetic nerve. RSNA was amplified and integrated by the use of R-C integrator. Power spectra of the RSNA and the values of squared coherence between the arterial pressure waveform and the RSNA were calculated by the computer system. In animal with TAH, coherence at the cardiac rhythm frequency was decreased, and coherence at the TAH pumping rhythm frequency was increased. These results indicate that the arterial pulse wave which was observed in TAH animal contributed to sympathetic neurogram.

Animals↗

Clinical application of the ventricular assist devices in Japan.

From 1980 to March in 1989, there were 177 clinical application of ventricular assist device in Japan. Original diseases were 50% ischemic heart disease and 37% valvular disease. Duration of assistance ranged from one hour to 70 days. Thirty-one cases weaned from ventricular assistance and 11 cases became long-time survivors.

Cause of Death↗

Sympathetic nerve activity during maintaining circulation with only left ventricular assist device.

Maintaining circulation with an left ventricular assist device (LVAD) alone during cardiac arrest until heart transplantation, was evaluated by the use of the sympathetic neurogram. To evaluate the influences of this method on autonomic nervous system, sympathetic neurogram was analyzed by power spectrum and coherence function. In acute animal experiments using mongrel dogs, LVAD were implanted. After the LVAD implantation, ventricular fibrillation was induced electrically. Renal sympathetic nerve activity (RSNA) was detected by the use of bipolar electrodes attached to the left renal sympathetic nerve. Values of squared coherence between the arterial pulse wave and RSNA were calculated. Under the condition of circulatory maintenance with LVAD, coherence at the cardiac rhythm frequency was decreased, and coherence at the LVAD pumping rhythm frequency was increased. These results suggest that the arterial pressure which was observed during maintaining the circulation with only LVAD contributed to sympathetic neurogram.

Animals↗

Hydrodynamic endurance test of the prosthetic valve used in the various types of the ventricular assist device.

To evaluate the various basic designs of the pump chambers used in the ventricular assist devices (VADs), hydrodynamic endurance test was performed from the viewpoint of the durability of the prosthetic valves used in the VAD. For the hydrodynamic analysis, we designed three basic types of pump (sac type, diaphragm type, and pusher plate type) using the same material and having the same capacity and shape. Prosthetic valves in these VADs were tested from the standpoint of the water hammer effect, which affects the valve durability, to determine which pump design would be most durable as a prosthetic valve in the VAD. The water-hammer phenomenon was evaluated using the maximum pressure gradient (MPG) across the prosthetic valve in the moc circulatory loop. Maximum pump output was recorded when we used the diaphragm type model, and minimum MPG in the commonly used driving condition of the VAD were recorded when we used the sac type model. The results suggest that the sac type VAD model is the most durable design for the prosthetic value.

Adult↗

Development and clinical evaluation of the long time digital Holter ECG system using non-tracking technology.

Newly developed long time digital Holter ECG system utilizing a stamp-size non-tracking (NT) tape which can be used for 192 hours as 2ch recording, was evaluated in the clinical cases. The system has employed newly developed VLSIs and NT technology which enables to obtain reliable long time recording with smaller and lighter Holter system of ECG and variety of biological signals. The results indicated that good data reproduction was shown in this system.

Adult↗

Systemic circulation with high frequency blood flow--analysis from neurophysiological point of view.

The vibrating electromagnetically driven univalved artificial heart, which provided more than 10 1/min at 10 Hz/sec. vibration, was developed in our team. This vibrating electromagnetic pump (VEMP) produced the original flow pattern compared with the flow pattern of the natural heart, so that circulatory regulatory system during maintain the circulation with VEMP must be investigated before the clinical application. In order to assess the effect of high frequency blood flow produced by the VEMP from the neurophysiological point of view, power spectral analysis of the hemodynamics was performed. VEMP was implanted as the total left heart bypass in adult goats and right heart circulation was maintained by natural hearts. In arterial blood pressure during maintain circulation by the high frequency blood flow, Mayer waves (0.01-0.15 Hz) were significantly decreased, though respiratory waves (0.25-0.40 Hz) were not significantly changed. These results suggest that circulatory regulatory system was influenced by the high frequency blood flow produced by the VEMP.

Animals↗

[A case of giant cell myocarditis associated with a progressive disturbance in the conduction system].

A 73 year old male patient with a history of pulmonary tuberculosis was admitted to our department because of dyspnea and abdominal pain. The chest X-ray film on admission showed bilateral lung congestion. The ECG showed atrial fibrillation, left axis deviation and incomplete right bundle branch block. Five days after admission, the ECG changed into sinus rhythm and complete right bundle branch block. Eight days after admission, the patient complained of chest pain and the ECG showed ST elevation in II, III, aVF, reciprocal ST depression in V, and complete A-V block with junctional rhythm. Emergency coronary angiography revealed no significant stenosis. Echocardiography showed reduced contraction of the inferior wall and diffuse granular echoes in the myocardium. Light microscopic study revealed fibrosis, infiltration of eosinophils and histiocytes, degenerated myocardium and multinucleated giant cells. Some of the giant cells were morphologically similar to myocardium, so the myocardium might be a place of immunological reaction.

Aged↗

Effect of left ventricular assistance on sympathetic tone.

To determine the effect of left ventricular assist device (LVAD) pumping on sympathetic tone, renal sympathetic nerve activity (RSNA) was detected in acute animal experiments. Our TH-7B pneumatically driven, sac-type ventricular assist device was used in 7 adult mongrel dogs. RSNA was detected by the use of bipolar electrodes attached to the left renal sympathetic nerve. RSNA was amplified and integrated by use of an R-C integrator circuit. The area of the integrated nerve discharge per unit time was calculated in the computer system and expressed as RSNA per unit time. During LVAD pumping, RSNA decreased with increase in blood pressure, with an increase in pulmonary artery flow, and with a decrease in left atrial pressure. These data suggest that LVAD has an effect on the sympathetic nervous system which is mediated by the aortic and cardiopulmonary baroreflex system.

Animals↗