Left heart bypass using the oscillated blood flow with totally implantable vibrating flow pump.

Aiming at a totally implantable ventricular assist device (VAD), a vibrating flow pump (VFP) was developed in Tohoku University. A transcutaneous energy transmission system (TETS) using an amorphous fiber was developed for the totally implantable VAD system. The VFP works with a higher frequency than the natural heart of a biological system, a frequency of 10-50 Hz. In this research, animal experiments on left heart bypass were performed with healthy goats. Blood from the apex of the left ventricle was received and was sent to the aorta so that an adequate supporting effect of the left heart was provided. In particular, the depression effect of the left ventricle was obvious. As a result, sufficient artificial heart flow was provided. For a totally implantable type VAD, left heart bypass of almost 100% may become necessary in some situations. Therefore, apex approaches of left heart bypass may be desirable. From an anatomical consideration, an apex of the heart is suitable for the VFP of this totally implantable type. In the left heart bypass for which the apex of the heart was used, an almost 100% bypass was possible. This is a requirement that is important when waiting for recovery of sufficient cardiac function. It is also important that left heart circulation is maintained fully by an artificial heart of the complete implantation type. The VFP was considered to be useful as a totally implantable type artificial heart from the results.

Animals↗

Control of the pulmonary arterial resistance by the use of the oscillated assist flow.

In the clinical application of supporting circulation, the treatment of a patient with pulmonary hypertension is very important. We developed the electromagnetically driven vibrating flow pump (VFP) as a totally implantable type ventricular assist system. The artificial heart driven by electromagnetic forces creates high speed oscillation flow around 10-50 Hz. Assistance by high-speed oscillation flow has an interesting influence on the cardiovascular system. In this study, we carried out research on the influence such oscillation flow had on the pulmonary arterial vessels, and the supporting flow wave-form that controlled pulmonary vascular resistance was considered. Six healthy adult goats of both sexes were used in the experiments. We carried out inhalation anesthesia and performed intubation. The thorax was opened through left fourth rib resection. Right heart bypass was performed from the right atrium to the pulmonary artery. The flow of right heart assistance was maintained within 20-25% of total flow. Our purpose was to add flow of a specific high frequency to the right heart circulation. The hemodynamic parameters were recorded on a magnetic tape data recorder and input into a computer through an A-D converter. A result identified was that the pulmonary vascular resistance changed according to the alteration of the driving frequency of the VFP even during the same flow assistance. The resistance of the pulmonary arterial vessels became smaller when the driving of the VFP of 30 Hz was added to the right heart circulation. This was significant even when compared with continuous flow right heart assist. The characteristics of impedance appeared to have interesting alterations as well. Control of pulmonary vascular resistance by right heart assistance becomes possible if these results are applied. Accordingly, it may become one of the choices for treatment of a patient with pulmonary hypertension.

Animals↗

Development of vibrating flow pump for left ventricular assist circulation.

Vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-40 Hz. In this study, new type VFP was developed as a ventricular assist device. Left Ventricular assist circulation using VFP were performed as aseptic animal experiments using goats. hemodynamic parameters were recorded continuously at awake state. Driving frequency of VFP was 25 Hz and pump flow rate was controlled to approximately 2 l/min. Frequency of VFP was 25 hz and pump flow rate was controlled to approximately 2 L/min. Frequency analysis method was used for analyzing hemodynamics. The peak of power was observed at 25 Hz from the Fourier transformation of blood flow waveform. Systemic vascular resistance was decreased by the start of left ventricular assistance using oscillated blood flow. No fatal arrhythmia was observed during this study. As the conclusion, new type VFP has a sufficient performance for left ventricular assistance. Small size blood pump may be enabled by the oscillated blood flow because VFP is driven at high frequency moving with short stroke volume.

Animals↗

Nasopharyngeal colonization with Haemophilus influenzae type b among infants and children in Japan.

Healthy carriers of Haemophilus influenzae type b (Hib) play an important role in the spread of invasive Hib disease. The aim of the present study was to estimate Hib colonization among infants and children in Japan. Specimens from throat and nasopharyngeal cultures were obtained by thorough swabbing of both tonsils and the posterior pharynx. Specimens were inoculated on Hib antiserum agar. This was prepared with Levinthal base and Hib antiserum. Conventional methods were used concomitantly. Four of 474 infants from 1-48 months of age (0.84%) had Hib cultured from their nasopharynx. The carriage rate in 1-12 months old infants was 0.62% (2/322 cases), and that in 13-48 month old children was 1.32% (2/152 cases). Five of 167 (3.0%) 13-year-old children, and five of 154 (3.2%) 9-year-old children were asymptomatic carriers. Thirty-five of 104 household contacts of a patient with invasive Hib disease (33.6%) had Hib colonization. The carriage rate in healthy Japanese children may not be different from that in the USA prior to the availability of the conjugate Hib vaccine. The Hib carriage rate in household contacts of patients with invasive Hib disease was higher than in healthy children (P < 0.005). Our results suggest the possibility of an outbreak of invasive Hib disease in Japan.

Adolescent↗

Nonlinear mathematical analysis of the hemodynamic parameters during left ventricular assistance with oscillated blood flow.

For the development of a totally implantable ventricular assist system (VAS), we have been developing the vibrating flow pump (VFP), which can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable system. In this study, effects of left ventricular assistance with this unique oscillated blood flow were analyzed by nonlinear mathematics for evaluation as the entire circulatory regulatory system, not as a separate part of the system. Left heart bypasses using VFPs from the left atriums to the descending aortas were performed in chronic animal experiments using healthy adult goats. Electrocardiogram (ECG), arterial blood pressure, VFP pump flow, and flow of the descending aorta data taken while the goats were awake were recorded in the data recorder and analyzed in the personal computer system through the AD convertor. Using nonlinear mathematics, time series data were embedded into the phase space, and the Lyapunov numerical method, fractal dimension analysis, and power spectrum analysis were performed to evaluate the nonlinear dynamics. During left ventricular assistance with the VFP, Mayer wave fluctuations were decreased in the power spectrum, the fractal dimension of the hemodynamics was significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that nonlinear dynamics, which mediate the cardiovascular dynamics, may be affected during LV bypass with oscillated flow. Decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased the peripheral resistance. Decreased sympathetic discharges may be the origin of the decreased Mayer wave and fractal dimension. These nonlinear dynamical analyses may be useful to design the optimal VAS control.

Animals↗

Hemolysis test of disposable type vibrating flow pump.

The vibrating flow pump (VFP) can generate high frequency oscillated blood flow. Because of the high frequency driving with short stroke volume, the pump system can be small. The disposable type VFP (D-VFP) was developed for use for extracorporeal circulation. The electromagnetic actuator was detached from the vibrating tube, which was newly designed to be a disposable tube with a jellyfish valve. Hemolysis tests of the D-VFP, VFP, centrifugal pump, and roller pump were performed in a mock circulation study using goat blood. Plasma free hemoglobin was measured every 15 min under the same conditions. The plasma free hemoglobin of the D-VFP was 16 mg/dl although that of the VFP was 160 mg/dl at 30 min. The plasma free hemoglobin of the centrifugal pump and roller pump at 30 min were 3 mg/dl and 9 mg/dl, respectively. The hemolysis performance of the D-VFP may be studied further as a result of this study. Two important factors affecting hemolysis development may be the materials of which the vibrating tube is made and heat transmission from the actuator. The D-VFP has a smooth acrylic surface for blood contact compared with the metal surface of old type VFP. The electromagnetic actuator of the VFP surrounded the vibrating tube, so heat from the actuator could be easily transmitted to the blood. Because the D-VFP has a disposable vibrating tube that is detached from the actuator, heat is not readily transmitted to the blood. A mock circulation study of heat transmission was performed using the D-VFP and VFP. Results of the heat transmission study showed that the fluid temperature of the D-VFP was not increased and stayed at room temperature although that of the VFP increased approximately 1 degree C above room temperature. The D-VFP may be a good style for the development of the VFP for use for extracorporeal circulation.

Acrylates↗

Development of a novel centrifugal pump: magnetic rotary pump.

The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impellers. We made a prototype MRP and examined its hemodynamics in mock circulation. The prototype MRP flow rate is only 1.0 L/min with an afterload of 30 mm Hg, and we have made some modifications in the size and drive mechanisms from these results. The modified MRP can achieve high flow rates and rotational speeds (6.0 L/min with an afterload of 100 mm Hg, 2,000 rpm) in a mock circuit, and the modified MRP was used for left heart assistance in an acute animal experiment. The MRP could maintain the hemodynamics of an anesthetized adult goat. These results suggest that the MRP needs to be improved in several areas, but the MRP may be useful as a blood pump.

Animals↗

Pulmonary arterial impedance analysis by the use of the oscillated assist flow.

Pulmonary arterial impedance is an important and interesting characteristic that can be used to evaluate the physiological properties of the pulmonary vessel. However, power spectrum analysis of the pulmonary artery pressure and flow pattern have suggested that peak power in the relatively high frequency range (> 10 Hz) is significantly low; thus, we cannot analyze the vessel properties in the high frequency range. In this study, we used the newly developed vibrating flow pump (VFP), which can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for right heart bypass, to evaluate the pulmonary arterial impedance pattern in the high frequency range. Acute animal experiments of the right heart bypass from the right atrium to the pulmonary artery using 6 healthy adult goats were performed. The flow pattern and pressure of the pulmonary artery, electrocardiograms (ECGs), and arterial and right atrial pressures were continuously monitored during the experiments. Spectral analysis of the hemodynamic parameters using the fast Fourier transform (FFT) method was performed to evaluate the spectral properties. The coherence function, transfer function, and phase patterns were calculated to analyze the impedance pattern in the relatively high frequency area. Previously, various investigators had tried to analyze the impedance patterns of the pulmonary artery; however, they could not analyze the impedance patterns over 10 Hz because the spectral patterns of the pulmonary flow do not have high power at high frequencies. These physiological analyses may be useful in designing the optimal pulmonary circulation.

Animals↗

Development of intracoronary local adhesive delivery technique.

Acute coronary occlusion may occur in weak coronary atherosclerotic lesions, including dissection, ulceration or thrombus. In some cases of occlusion "bail-out" is performed by using recently developed New Devices. However, these have not yet completely solved the problem to this end, we designed a new method of coronary revascularization, the Intracoronary Local Adhesive Delivery Technique, utilizing antithrombotic and absorbable adhesive injected locally into the fragile and morbid arterial wall using a drug delivery PTCA catheter more flexible than the existing New Devices. This adhesive strengthened and hardened the lesions. In this study, we examined the efficacy of making an adhesive cylinder in arteries of similar size to the coronary, through acute animal experiments using the existing clinical adhesives and drug delivery PTCA catheters and 12 femoral arteries of adult goats. We were successful in forming firm tunnels along the inside of six arteries, infused with approximately 0.04 ml Cyanoacrylate. These tunnels were observed with intravascular ultrasound (IVUS) imaging and evaluated microscopically. These results suggest the feasibility of this method as a new approach for making synthetic resinous stents.

Absorption↗

Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers.

We have developed a vibrating flow pump (VFP) that can generate oscillated blood flow with a relatively high frequency (10-50 Hz) for a totally implantable ventricular assist system (VAS). To evaluate the newly developed VAS, left heart bypasses, using the VFP, were performed in chronic animal experiments. Hemodynamic parameters were recorded in a data recorder in healthy adult goats during an awake condition and analyzed in a personal computer system through an alternating-direct current converter. Basic performance of the total system with a transcutaneous energy transmission system were satisfactory. During left ventricular assistance with the VFP, Mayer wave fluctuations of hemodynamics were decreased in the power spectrum, the fractal dimensions of the hemodynamics were significantly decreased, and peripheral vascular resistance was significantly decreased. These results suggest that cardiovascular regulatory nonlinear dynamics, which mediate the hemodynamics, may be affected by left ventricular bypass with oscillated flow. The decreased power of the Mayer wave in the spectrum caused the limit cycle attractor of the hemodynamics and decreased peripheral resistance. These results suggest that this newly developed VAS is useful for the totally implantable system with unique characteristics that can control hemodynamic properties.

Animals↗

Enhancement of nasal salmon calcitonin absorption by lauroylcarnitine chloride in rats.

PURPOSE: We investigated optimum formulation characteristics in the nasal absorption of salmon calcitonin (sCT) by incorporation of acylcarnitines. METHODS: Nasal sCT formulations were administered to anesthetized rats. Plasma calcium level was measured and pharmacological bioavailability (P.bioav) was calculated. RESULTS: Nasal sCT absorption was significantly enhanced by carnitines with acyl groups of 12 or more carbon atoms. Enhancement by lauroylcarnitine chloride (LCC) was observed at its critical micelle concentration and reached a plateau at the concentration of 0.1 percent. Optimal absorption was achieved at a molar ratio of LCC to sCT of 5:1. Enhancement was not influenced by osmolarity and maximum enhancement was obtained at pHs 3.1 and 4.0. CONCLUSIONS: The 12-carbon LCC was the strongest enhancer among acylcarnitines. Micelle formation played a key role in this enhancement effect.

Administration, Intranasal↗

Totally implantable ventricular assist system using a vibrating flow pump.

A totally implantable ventricular assist system (VAS), including a drive system and a percutaneous electric energy transmission system, was developed and evaluated in acute animal experiments using adult goats. This newly designed VAS mainly consists of a vibrating tube, coils, magnets, and a jelly-fish valve as the outlet valve. For energy transmission, a new implantable transmitter with a plain weave structure was proposed as a noncontacting transform by using the spinal amorphous magnetic fibers. The fluid mechanical and hemodynamic properties and the efficiency of the energy transmission system were evaluated in acute animal experiments using healthy adult goats. This vibrating electromagnetic artificial heart (AH) could generate more than 10 L/min as output volume, with 10 Hz vibration using 20 volts as supplied voltage. The total efficiency of the percutaneous energy transmission system was 76%, and temperature increases were within the acceptable range, suggesting the usefulness of our newly developed implantable VAS.

Animals↗

Fractal dimension analysis of the oscillated blood flow with a vibrating flow pump.

To analyze the hemodynamic parameters during circulation with oscillated blood flow, nonlinear mathematical analyzing techniques, including fractal theory, were utilized. Vibrating flow pumps (VFP) were implanted as a left heart bypass, and the ascending aorta was clamped to constitute the total left heart circulation with oscillated blood flow in acute animal experiments using 7 adult goats. Using nonlinear mathematical analyzing techniques, reconstructed attractors of the arterial blood pressure waveform in the phase space during natural circulation and oscillated circulation were analyzed. Using the Grassberger-Procaccia correlation dimension analyzing technique, fractal dimension analysis of the reconstructed attractor was performed. During VFP bypass, lower fractal dimensions of the reconstructed attractor were shown compared with those during natural heart circulation. The results suggest that lower dimensional chaotic dynamics contributed to the circulation with oscillated blood flow.

Animals↗

Chaotic behavior of hemodynamics with ventricular assist system.

In order to analyze hemodynamic parameters during left ventricular assistance as an entity and not as decomposed parts, non-linear mathematical techniques were utilized. Pneumatically actuated ventricular assist systems (VAS) were implanted as left heart bypasses in acute animal experiments, using healthy adult mongrel dogs. By the use of the non-linear mathematical technique, the arterial blood pressure waveform (AP) was embedded into the four-dimensional phase space and projected into the three-dimensional phase space. The Lyapunov numerical method was used as an adjunct to the graphical analysis of the state space. The phase portrait of the attractor showed a complex structure; a three dimensional solid torus with a screw type structure as a part, suggesting deterministic chaos in the AP without left ventricular assistance. Positive lyapunov exponents confirmed the existence of chaos. During counterpulsation mode left ventricular assistance, the phase portrait of the attractor showed a more complex structure, and positive Lyapunov exponents suggested a greater dimensional deterministic chaos. However, non-structured patterns were seen in the phase space during internal mode VAS driving, suggesting the possibility of dissipative dynamics in the four dimensional phase space. These results suggest that the cardiovascular system with counterpulsation mode VAS driving is in a homeochaotic state, which is thought to be a flexible and intelligent control system. And there is greater dimensional complex dynamics in the circulatory regulatory system with VAD during internal mode assistance.

Animals↗

Chaotic hemodynamic during oscillated blood flow.

A vibrating flow pump (VFP), which can generate oscillated blood flow (10-50 Hz/min), has been developed by our team for the artificial heart system. However, the flow pattern of this pump was different from that of the natural heart; therefore, it is important to analyze the effect of this oscillated blood flow on the circulatory regulatory system. To analyze the hemodynamics of high frequency oscillated blood flow as an entity, (not decomposed), nonlinear mathematical techniques were utilized. VFPs were implanted between the left atrium in animal experiments using adult goats. After the implantation procedure, the ascending aorta was clamped to constitute the complete left heart circulation with VFP. Using a nonlinear mathematical technique, an arterial blood pressure waveform was embedded into four-dimensional phase space and projected into three-dimensional phase space. The Lyapunov numerical method was used as an adjunct to graphic analysis of the state space. Phase portrait of the attractor showed a high dimension complex structure, suggesting deterministic chaos during natural circulation. However, phase portrait of the hemodynamics during oscillated blood flow showed a single circle with banding and a forbidden zone, similar to a limit-cycle attractor, suggesting a lower dimensional dynamic system. Positive Lyapunov exponent during oscillated blood flow suggests the existence of lower dimensional chaotic dynamics. These results suggest that the circulatory regulatory system during oscillated blood flow may be a lower dimensional homeochaotic state; thus, hemodynamic parameters must be carefully regulated when unexpected external stimuli are present.

Animals↗

Scintigraphic monitoring of coronary artery occlusion due to Kawasaki disease.

Noninvasive monitoring of the process of coronary occlusion will probably aid in determining the timing of therapeutic interventions for Kawasaki disease. A pair study of coronary angiography and thallium scintigraphy after dipyridamole infusion-single-photon emission computed tomography with dipyridamole infusion (Dp-SPECT) was repeated at least twice at intervals of several years in 29 patients, and these findings were compared and analyzed in a chronologic manner. The current study demonstrated that angiographic stenosis was more severe, with an increase in the severity of the perfusion defect. Positive rates determined by Dp-SPECT increased with increasing severity of stenosis on angiography. Angiographic findings from the first to the second serial study that showed worsening, no change and improvement were correctly diagnosed from scintigraphic changes in 94% of coronary arterial lesions. About half of the arteries with progression in stenotic severity could be found before complete occlusion by scintigraphic monitoring. It is concluded that Dp-SPECT can be used as a noninvasive monitor of the occurrence and progression of coronary stenoses due to Kawasaki disease.

Coronary Aneurysm↗

Origin of the rhythmical fluctuations in the animal without a natural heartbeat.

In order to analyze the origin of the rhythmical fluctuations in the cardiovascular system, an artificial heart, which does not have rhythmical periodicities such as altering heart rate and cardiac function, was utilized in chronic animal experiments with adult goats. Two pneumatically actuated ventricular assist devices were implanted as a total biventricular bypass under general anesthesia, and then the natural heart was electrically fibrillated to constitute the biventricular bypass type of complete prosthetic circulation model. All hemodynamic data were recorded under awake conditions and were calculated in the computer system by spectral analysis methods. In the power spectrum of the arterial blood pressure of the animal with the artificial heart, the Mayer wave peak and respiratory wave peak were clearly observed, and spectral analysis including the coherence function suggests that the Mayer waves originated from the peripheral vascular resistance and the respiratory waves probably originated from the periodicities of the pulmonary circulation. These fluctuations in the circulatory system influenced the arterial baroreflex system and transfer to the sympathetic outflow through the central baroreflex system, which suggests that rhythmical fluctuations in hemodynamic parameters originate at least in part from these vascular periodicities.

Animals↗

Identification of the deterministic chaos in cardiovascular dynamics by the use of the non-linear mathematics.

Chaotic behavior in cardiovascular dynamics was thought to be one of the important information to analyze the circulatory regulatory system. Several investigators studied the attractor in the signals of the electrocardiogram, and found the strange attractor, suggesting dynamics compatible with deterministic chaos, by the use of the non-linear mathematics. It is interesting problem to analyze the hemodynamic parameters by the use of non-linear mathematics for the determination of the physiologically optimal circulatory condition. In this study, Chaos analyzing system was developed to identify the deterministic chaos in cardiovascular regulatory system by the use of the non-linear mathematics including phase plane plots, embedding, and lyapunov exponents. Time series data of the hemodynamic parameters in the chronic animal experiments was analyzed by this system, and satisfactory attractor was obtained by the use of the phase plane plots and embedding techniques. Furthermore, calculation of the lyapunov exponents showed the existence of the deterministic chaos in arterial blood pressure in the chronic animal experiments using adult goats, suggesting this tool is useful for analyzing cardiovascular dynamic behavior.

Animals↗