Search PubMed⌕ Search

Biomedical subjects

T Sharma

Publications and source records attributed to T Sharma.

189 records · Page 11Linked to original sources

Effect of low-dose acute X-irradiation on the frequencies of chromosomal aberrations in human peripheral lymphocytes in vitro.

In a coordinated research programme sponsored by the International Atomic Energy Agency, the frequencies of chromosomal aberrations induced in peripheral blood lymphocytes (in vitro) by 250 kV X-rays at low doses (0.4, 1, 2, 3, 5, 10 and 30 rad) were determined. Blood from 2 donors was used to conduct one master experiment at these dose levels. The culture time used was 48 h and all samples including the controls were processed according to a standard protocol. The coded slides were scored by investigators from 10 participating laboratories. The main results are the following: (1) the frequencies of all types of chromosome aberrations at 0.4 rad are significantly lower than the control values; (2) there is no increase in the frequencies of dicentrics up to 2 rad and in those of terminal deletions up to 5 rad; (3) the mean frequencies of all aberrations considered together are not significantly different from one another at 1, 2 and 3 rad (P = 0.05); and (4) over the entire dose range the dose-effect relationship is clearly non-linear. A fit of these data to a linear quadratic model (E(D) = c + alpha D + beta D2) showed that the observed total aberration frequencies at doses 1, 2, 3 and 5 rad are below the curve defined by the model. The deviations can be explained by an altered kinetics of aberration production at very low doses probably due to DNA repair mechanisms operating these cells.

Adult↗

Blood lymphocyte culture system: quantitative analysis of X-ray-induced chromosome aberrations in man, muntjac and cattle.

Peripheral blood lymphocytes of 3 mammalian species, man, muntjac and cattle, which have various amounts of DNA and divergent karyotypes, were exposed to 100-400 rad of X-rays, and frequencies of dicentrics and other aberrations were analysed at first post-irradiation metaphases. During experiments, various preparative or physical and biological factors that could influence the yield of chromosome aberrations were taken into account. The frequency of dicentrics scored at first post-irradiation metaphases showed best fit to both linear and quadratic dose-response curves, y = a + bD and y = bD + cD2 with a high correlation coefficient of 0.98 (P less than 0.001). The frequency of dicentrics obtained at different post-irradiation fixation times did not show significant variation, indicating a homogeneous sensitivity of peripheral lymphocytes to X-irradiation. BrdU incorporation following X-irradiation showed no increase in the frequency of chromosome aberrations. The frequency of dicentrics in man, muntjac and cattle showed a close correlation with their DNA content, but no meaningful correlation was found between the yield of dicentrics and the chromosome arm number or the nuclear volume. The ratio of dicentric yields, 1.00:0.67:1.04 obtained in man, muntjac and cattle were comparable to the ratio of their DNA contents, 1.00: 0.65: 1.07. The base-line frequency of SCEs was similar in the 3 species and no significant variation in SCE frequency was noticed even after administration of 400 rad of X-rays.

Adult↗

Explantation of silicone plate haptic intraocular lenses.

The stress on small self-sealing incisions in cataract surgery has resulted in the increased use of foldable intraocular lenses (IOL). Plate haptic silicone IOLs implanted with the help of an injector require extremely small incision lengths and are extensively used. The authors discuss difficulties in explanting such lenses, especially in inflamed eyes. Two patients who underwent plate-haptic silicone IOL explantation for postoperative bacterial endophthalmitis are described. Plate haptic IOLs have a tendency to dislocate posteriorly because of poor capsular fixation and increased posterior bowing. Enlarging a small rhexis prior to attempting explantation of these lenses reduces this complication. Difficulties inherent in explanting plate haptic silicone IOLs in inflamed eyes are discussed, along with suggestions to overcome them.

Aged↗

A customised portable LogMAR chart with adjustable chart illumination for use as a mass screening device in the rural population.

AIM: To develop a customised, portable, cost-effective (logarithmic minimal angle resolution) LogMAR chart with adjustable illumination for use as a mass vision-screening device in the rural population. MATERIALS AND METHODS: Visual acuity of 100 individuals was evaluated with a customised chart and compared with the standard Early Treatment Diabetic Retinopathy Study (ETDRS) chart and Snellen's Chart. Bland and Altman analytical techniques were used for analysis. RESULTS: Test-retest variability of the customised chart was just a one-line difference (95% CI for agreement), and so were the results with the standard ETDRS charts; a variability of 3-line was noted with Snellen's chart. Two-line differences were observed when comparison was made with Standard ETDRS chart and 2 to 3-line differences with Snellen's chart. CONCLUSION: The customised portable LogMAR chart with adjustable illumination shows less test-retest variability and better agreement with standard ETDRS chart; therefore, it can be used as a mass vision-screening device in rural settings.

Adult↗