Search PubMed⌕ Search

Biomedical subjects

T Mamiya

Publications and source records attributed to T Mamiya.

At least 73 records · Page 4Linked to original sources

[Three-dimensional display of 99mTc-MIBI myocardial scintigraphy].

One of 99mTc-hexakis, 99mTc-methoxyisobutyl isonitrile (MIBI), has been demonstrated to have a myocardial uptake proportional to regional coronary blood flow. In this study, 99mTc-MIBI myocardial scintigraphy were performed for 16 patients with ischemic heart disease. After injection of 740 MBq of 99mTc-MIBI, 64 projection images were collected during a 360-degree rotation. Three-dimensional (3D) display of the left ventricle was reconstructed with depth-shading method from 99mTc-MIBI SPECT images, which were reconstructed by filtered back projection method. In 9 of the patients, left ventricular cineangiography were performed as diagnostic gold standard. Four physicians blinded to patients' clinical informations interpreted 3D images and SPECT images on separate occasions. Diagnosis of hypoperfusion by 3D displays agreed with those of SPECT in 92.9% (104/112 segments), and disagreed in 7.1% (8 segments). Sensitivity and specificity of 3D images were 87.0 and 93.9%, which were not statistically different (p less than 0.05) from that of SPECT images (91.3, 97.0%). Receiver operating characteristic (ROC) analysis revealed nearly identical curves for the two. Although 3D display had nearly identical diagnostic ability with SPECT, observers reported that 3D images were easier to diagnose than SPECT images. An advantage of the 3D display is that the display gives a more realistic impression of the left ventricle to an observer than tomography or planar imaging. Another advantage is that 3D display can reduce the amount of data storage compared with that of SPECT. In conclusion, 3D images may be useful for diagnosis of hypoperfusion of left ventricle.

Adult↗

[Developmental changes in normal images of 123I-IMP brain SPECT in young children].

In an attempt to determine the normal evolution of N-isopropyl p-I-123-iodoamphetamine (123I-IMP) single photon emission computed tomography (SPECT), we selected 12 children (an age range of 1 month-3 year) who were diagnosed as normal in follow-up between 6 month-3 year by neurological examination, X-ray computed tomography, electroencephalography and 123I-IMP SPECT in our 78 cases. SPECT of the brain was performed 30 minutes after intravenous administration of 74 MBq (2 mCi) 123I-IMP using a rotating gamma camera equipped with a 30-degree slant-hole collimator. In neonates, a predominant activity was observed in the basal ganglia and thalamus, with only slight parietal and occipital activity. Frontal cortex was barely recognizable. Under 1 year, cortical activity was gradually increased and clearly visible. After 1 year, SPECT images were similar to those of adult. In conclusion there was an important modification of the regional perfusion pattern in relation to brain maturation.

Amphetamines↗

Gallium scintigraphy in neoplastic angioendotheliosis of the lung.

A case of neoplastic angioendotheliosis of the lung is reported. A 56-year-old man presented with a 2-month history of fever, increased serum lactic dehydrogenase, and arterial hypoxemia. Chest radiography revealed diffuse reticulonodular opacity, whereas CT scanning showed diffuse small nodular areas of increased attenuation with indistinct borders. Diffuse pulmonary uptake of Ga-67 was noted in scintigraphy. Combination chemotherapy designed for lymphoma induced a remission of the disease.

Gallium Radioisotopes↗

Cinematic three-dimensional surface display of cardiac blood pool tomography.

A method of three-dimensional cinematic display (3D cine) of cardiac blood pool tomography is described. ECG-gated transaxial blood pool imaging was obtained from a set of projection images that were collected from 32 images with 10 ECG-gated images per projection during a 180 degrees arc of a rotating gamma camera. A surface contour of the blood pool was determined by a set of isocount lines (40-55% of the maximum pixel counts) of the transaxial images. 3D cine was made by a depth-shading method, in which brightness of a given point on the contour was set proportional to the distance between the viewing plane and the point and to the incident angle formed by the viewing line and the surface of the point. In 15 patients, 3D cine showed hypokinesia, akinesia, dyskinesia, ventricular aneurysm, and opposite motions of the atria and ventricles. Diagnoses of left ventricular motion by 3D cine agreed well with those by echocardiography and contrast left ventriculography.

Aged↗

[The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner--the ROC analysis on the diagnosis of perfusion defect and redistribution].

We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological informations, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows: (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician, (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading, (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP.

Amphetamines↗

[Clinical significance of I-123 IMP brain SPECT in children with brain diseases].

Single photon emission computed tomography (SPECT) of the brain using N-isopropyl p-I-123-iodoamphetamine (I-123 IMP) was performed in 43 children with suspected brain diseases. Forty-three children (25 males and 18 females), with an age range of 24 days-15 years (mean: 6.6 years), were included in the study. Six patients were subsequently diagnosed as normal. Early SPECT of the brain was performed 30 minutes after intravenous administration of 74-111 MBq (2-3 mCi) I-123 IMP using a rotating gamma camera equipped with a 30-degree slant hole and medium energy collimator. Transverse images were reconstructed by Shepp-Logan filtered back projection method with attenuation correction after spatial filtering using an 8th order Butterworth-Wiener filter. Findings of I-123 IMP SPECT were compared with those of X-ray computed tomography (CT) and electroencephalography (EEG). The results showed that 1) In I-123 IMP SPECT, abnormality was found in 30 out of 37 children with brain diseases. The incidence of abnormal findings in the 37 patients was 81% in I-123 IMP SPECT, 61% in X-ray CT, and 78% in EEG., 2) In both cryptogenic and secondary epilepsy, the incidence of abnormality was higher in I-123 IMP SPECT than in X-ray CT. (70% and 94% vs 50% and 81% respectively). Epileptic foci detected by EEG did not correspond with defects found using I-123 IMP SPECT in 27% of the patients., 3) In asphyxiated infants, a high incidence of abnormality was observed on both I-123 IMP SPECT (86%) and X-ray CT (86%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

[The experience of a new double-catheter introducer for simultaneous bilateral internal iliac angiography].

We developed a new 8F catheter-introducer system designed for simultaneous insertion of two catheters into each internal iliac artery via a single puncture. This introducer has a common distal limb and a pair of proximal limbs connected in a Y-shaped fashion. Each of the proximal limbs has its own check valve and flushing side arm, through which one can pass two catheters separately. We succeeded in placing each of two catheters at desired sites in three cases of pelvic angiography. This system will be of great help in pelvic angiography and infusion-chemotherapy when bilateral catheterization is required.

Aged↗

[Generation of brain scintigram reports with a speech recognition device controlled by a personal computer].

Radiology reporting system using a speech recognition apparatus was applied to generation of reports on brain scintigram and SPECT. The number of words or phrases that were selected for the reporting system by the authors was 259. Rates of correct recognition at the first, second, and third or more utterance of the voices were 91.1, 5.0, and 3.9%, respectively. The recognition rates decreased from 96.6 to 88.0% when the mean lengths of the words or phrases varied from 6.4 to 3.3. Net time for the generation of 8 reports by the system was 21 minutes 26 seconds, while that by the traditional dictation-transcription method was 15 minutes and 53 seconds. This system seems to be useful because of much longer input time expected for an average doctor, who usually is not well trained in using a Japanese-word processor, and convenience for database management offered by the system.

Brain↗

[Treatment of priapism by caverno-spongio-anastomosis].

We experienced two cases of priapism; one, idiopathic and low flow type, the other post-traumatic and high flow type. We tried caverno-spongio-anastomosis (CSA) as an operative treatment in both cases. Postoperative courses were uneventful. We suggest that CSA is a simple and reliable treatment of priapism.

Adult↗

Two dimensional polar display of cardiac blood pool SPECT.

A new method of ECG gated cardiac blood pool SPECT to illustrate the left ventricular (LV) wall motion in a single static image, two dimensional polar display (2DPD), was described. Circumferential profiles of the difference between end diastolic and end systolic short axis images of the LV were displayed in a similar way to the bull's eye plot of 201Tl myocardial SPECT. The diagnoses by 2DPDs agreed with those by cinematic displays of ECG gated blood pool SPECT in 74 out of 84 segments (85.5%) of abnormal motion, and 155 our of 168 segments (80.3%) of normal motion. It is concluded that 2DPD can evaluate regional wall motion by a single static image in a significant number of patients, and is also useful in comparing with the bull's eye image of 201Tl myocardial SPECT.

Aged↗

Factor analysis of multigated cardiac blood pool scintigram for the measurement of left ventricular ejection fraction.

Left ventricular ejection fraction (EF) was measured by factor analysis (FA) of multigated cardiac blood pool scintigram in 38 consecutive patients, and compared with that measured by the variable ROI method (EFVROI) with automated left ventricular contour detection. FA was automatically performed without operator intervention with a success rate of 100%. The correlation of EF with EFVROI was significant in the group of 22 patients with normal wall motion (r = 0.65, p less than 0.001), and the entire group of patients (r = 0.70, p less than 0.001), but not significant (p = 0.19) in the group of 16 patients with abnormal wall motion. In conclusion, left ventricular ejection fraction can be estimated by factor analysis of MUGA in patients with normal wall motion.

Adult↗

Scintigraphic and CT findings of Tietze's syndrome: report of a case and review of the literature.

A case of Tietze's syndrome is reported. A 43-year-old woman, who had experienced right anterior chest pain and tender swelling of the right first costosternal junction for seven months, showed increased accumulation of the right first, the right fourth, and the left first costochondral junction on bone imaging. Ga-67 imaging showed increased accumulation at the right first costosternal junction. CT showed sclerosis of the sternal manubrium, partial calcification of costal cartilage, and soft tissue swelling. Biopsy of the right first costal cartilage showed chronic inflammation with fibrosis and ossification. Increased uptake of bone gallium imaging is consistent with Tietze's syndrome.

Adult↗

[Clinical assessment of uneven ventilation by factor analysis of Xe-133 washout scintigram].

Factor analysis (FA) was applied to 50 consecutive Xe-133 washout lung scintigrams, and its findings were compared with dynamic scintigrams of Xe-133 washout (DSW). Mean transit time (MTT) of radioactive xenon measured by FA also was compared with that measured by height/area (H/A) or two-compartment analysis (2CA). In 12 patients with normal DSW, FA separated and located two factors: one represented background activity, and the other uniform washout from the lung. In 31 out of 38 patients (82%) with abnormal DSW, FA separated the same areas where the washout was delayed on DSW. In 5 (13%) patients, FA diagnosed more areas of delayed washout than DSW. FA failed in 2 (5%) patients, but this failure was due to small number of counts of pixels. Diagnosis by FA was seemed easier than diagnosis by DSW in 95% of all patients by the authors' impression. MTT by FA (y) correlated with MTT by 2CA (x) in small groups of patients: in 9 patients in whom only one MTT was obtainable by FA (r = 0.75, p = 0.02, y = 4.2x + 1.9), and in 8 patients of normal DSW in whom two MTT's were obtainable by FA (r = 0.77, p = 0.02, y = 0.69x + 6.2, y; shorter MTT by FA between the two). MTT by FA did not correlate with MTT by H/A. In conclusion, FA is useful for diagnosing uneven Xe-133 washout from the lung.

Adolescent↗

The unfolded map using 201T1 myocardial SPECT.

The unfolded map is a new method to show the 201T1 distribution of left ventricle using SPECT. In 52 cases these maps were obtained at the stress study and 4 h later. The maximal count profiles of the perimeters for each short axis image were unfolded and were arranged from the apex to base of the left ventricle into a two dimensional map. All patients had chest pain and were suspected of coronary artery disease. The unfolded map had significant correlations between coronary arteriogram and exercise ECG findings. In conclusion, this method reflects the ischemic area of left ventricular myocardium, closer to the real left ventricular myocardium than Bull's eye display and is useful in the diagnosis of coronary heart disease.

Adult↗

[Effect of intra-thoracic administration of an immune modulator (OK-432) with anti-cancer drugs (ADR and MMC)].

Fourty-three patients with pleuritis carcinomatosa have been treated with an intra-thoracic administration in four distinct ways: Adriamycin alone, OK-432 alone, the combination of Adriamycin with OK-432, or the combination of Mitomycin C with OK-432. Judging from an evaluation of the subsequent chest X-rays, the prognosis of the cases which received the combination therapy of the two drugs was significantly better to that of the others. There were no significant differences between cases with primary lung cancer and those with other cancers. As for the side effects after the administration, there were no side effects, such as the trouble the renal function or liver function, other than fever and a decrease in the W.B.C.

Adjuvants, Immunologic↗