Search PubMed⌕ Search

Biomedical subjects

T Mamiya

Publications and source records attributed to T Mamiya.

At least 55 records · Page 3Linked to original sources

Unrestrained nociceptive response and disregulation of hearing ability in mice lacking the nociceptin/orphaninFQ receptor.

In the G-protein-coupled receptor superfamily, the opioid receptor subfamily is constituted of the three distinct opioid receptors (namely delta-, mu- and kappa-subtypes) and the receptor for nociceptin (also designated orphaninFQ). The members of the opioid receptor subfamily were known to mediate a variety of cellular inhibitory effects. The three opioid receptors are known to play central roles in mediating analgesia and many other physiological activities; however, the nociceptin receptor was identified recently and less is known about its physiological roles. Here we report the generation and characterization of mice lacking the nociceptin receptor. The knockout mice showed no significant differences in nociceptive threshold and locomotor activity compared with control mice, but they lost nociceptin-induced behavioral responses. These results indicate that the nociceptin system is not essential for regulation of nociception or locomotor activity. On the other hand, we found insufficient recovery of hearing ability from the adaptation to sound exposure in the mutant mice. Thus, the nociceptin system appears to participate in the regulation of the auditory system.

Animals↗

Role of nitric oxide and cyclic GMP in the dizocilpine-induced impairment of spontaneous alternation behavior in mice.

The activation of N-methyl-D-aspartate receptors induces the synthesis of nitric oxide, which activates soluble guanylate cyclase and leads to the formation of cyclic GMP in the brain. The inhibition of nitric oxide production, as well as the blockade of N-methyl-D-aspartate receptors, has been reported to prevent the induction of hippocampal long-term potentiation and learning and memory formation in vivo, although the effects of inhibitors of nitric oxide synthase are still controversial. We investigated the putative role of nitric oxide and cyclic GMP in dizocilpine-induced memory impairment in mice. The nitric oxide synthase inhibitors, NG-nitro-L-arginine methyl ester and 7-nitro indazole, as well as dizocilpine, a non-competitive N-methyl-D-aspartate receptor antagonist, dose-dependently impaired spatial working memory in mice, assessed by their spontaneous alternation behavior in a Y-maze. The inhibitory effects of both NG-nitro-L-arginine methyl ester and dizocilpine on their behavior were completely reversed by 8-bromo-cyclic GMP. Cyclic GMP levels in the cerebellum were reduced by treatment with dizocilpine. NG-Nitro-L-arginine methyl ester and 7-nitro indazole reduced cyclic GMP levels in the cerebral cortex/hippocampus and cerebellum, and the suppressive effect of NG-nitro-L-arginine methyl ester on cyclic GMP levels in the cerebral cortex/hippocampus was reversed by co-treatment with L-arginine. Cyclic AMP levels in the brain were not affected by treatment with either dizocilpine, NG-nitro-L-arginine methyl ester, or 7-nitro indazole. Neither NG-nitro-L-arginine methyl ester nor L-arginine had any effect on monoamine and acetylcholine metabolism in the brain. These results suggest that the reduction in nitric oxide/cyclic GMP production in the brain may be responsible for dizocilpine-induced impairment of spontaneous alternation behavior in a Y-maze.

Animals↗

An approach to cerebral vasodilatory capacity in unilateral and bilateral cerebrovascular diseases using radiolabeled human serum albumin.

The acute cerebrovascular response to acetazolamide was assessed using a blood pool agent and planar dynamic imaging to evaluate cerebral vasodilatory capacity. Ten normal subjects and 12 patients with unilateral or bilateral cerebrovascular disease were studied. After the injection of radiolabeled human serum albumin, dynamic imaging of the anterior view of the head was started. Ten minutes later, 1000 mg of acetazolamide was infused. The dilatation index (the percent increase in activity at the peak response) was obtained for each cerebral hemisphere. The mean dilatation index in normal subjects was 17.1 +/- 3.2% (N = 20). The value was significantly lower in patients with multiple infarcts (7.7 +/- 1.1%, N = 8, P < 0.001), and below the normal range in two involved hemispheres of five patients with unilateral occlusive carotid artery disease and in three hemispheres of three patients with moyamoya disease. It was suggested that this simple method may be useful in assessing cerebral vasodilatory capacity in both unilateral and bilateral diseases.

Acetazolamide↗

[Measurement of cerebral blood flow in normal subjects by phase contrast MR imaging].

Global cerebral blood flow (CBF) was quantitatively measured with a two-dimensional phase contrast cine magnetic resonance (MR) imaging technique in 24 normal subjects (mean age, 38.6 years; range, 12-70 years). Cine transverse images of the upper cervical region (32 phases/cardiac cycle) were acquired with a 1.5 Tesla MR imaging unit. In five subjects, measurement of CBF was performed before and after intravenous administration of acetazolamide (DIAMOX, 15 mg/kg). Inter- and intraobserver variations in flow volume measurement were small (r = 0.970, standard error of the estimate (SEE) = 2.9 ml/min, n = 80; r = 0.963, SEE = 4.6 ml/min, n = 40, respectively). In measuring flow velocity, they were inferior to those of flow volume measurement. On a visually determined setting of region of interest (ROI), reproducibly of the measurement of flow velocity was not satisfactory in this study. Thus only the results of flow volume measurement are presented. Mean summed vertebral flow volume (171 ml/min, SD = 40.6) was significantly less than mean summed internal carotid flow volume (523 ml/min, SD = 111). Total blood flow volume showed a significant decline with age (r = 0.45, p < 0.05). The mean proportions of carotid and vertebral flow volume to total flow volume were 75.3% and 24.7%, respectively, and showed no significant change with age. The left-to-right ratio of vertebral flow volume (1.39) was significantly higher than that of internal carotid flow volume (0.99, r = 0.05). After DIAMOX i.v., the mean rate of increase in total flow volume was 157%. Mean rates of increase in carotid and vertebral flow volume were 154% and 166%, respectively, which were not significantly different. In conclusion, this method is useful for estimating carotid and vertebral flow volume.

Acetazolamide↗

Impaired hepatic function in segmental biliary obstruction demonstrated with a receptor-binding radiotracer.

A patient with cholangiocarcinoma underwent left-sided cholangiojejunostomy, and hepatic functional imaging with a receptor-binding radiotracer and SPECT was performed to evaluate the distribution of functional reserve. It revealed decreased accumulation in the regions with residual dilatation of the intrahepatic bile ducts, indicating several kinds of focal damage in hepatic function caused by segmental biliary obstruction. The radioligand may be useful in assessing regional hepatic function, and the high spatial resolution provided by SPECT appears to play an important role for this purpose.

Aged↗

Abnormal sympathetic innervation of the heart in a patient with myotonic dystrophy detected with I-123 MIBG cardiac SPECT.

Iodine-123 MIBG is a norepinephrine analog which can be used to image the sympathetic innervation of the heart. The authors report a patient with myotonic dystrophy whose I-123 MIBG SPECT revealed accelerated washout of I-123 MIBG from infero-posterior and a part of lateral wall, although Tl-201 SPECT showed no abnormal finding. The authors conclude that I-123 MIBG can be more sensitive in detecting the cardiac abnormality than Tl-201 SPECT in this disease.

3-Iodobenzylguanidine↗

Background correction in estimating initial renal uptake. Comparison between Tc-99m MAG3 and Tc-99m DTPA.

A gamma camera method with no blood sampling assesses differential renal function based on initial renal uptake, and requires background correction. The effect of background correction on estimates of initial renal uptake was compared on renograms using Tc-99m MAG3 and Tc-99m DTPA renographies in 14 patients. Renal counts for 2-3 minutes were obtained using three sets of regions of interest (ROIs): rectangular renal and subrenal background ROIs, rectangular renal and perirenal background ROIs, and hand-drawn renal and subrenal background ROIs. Correlations between estimates of initial renal uptake by the three methods were higher for Tc-99m MAG3 renography than for Tc-99m DTPA imaging, suggesting higher reproducibility in evaluating differential renal function using Tc-99m MAG3 renography and a gamma camera method. Although the ratio of counts in the suprarenal area to those in the subrenal area was significantly higher for the right side in the Tc-99m MAG3 study, probably because of hepatic activity, the relative uptake in the right kidney for Tc-99m MAG3 did not differ from that for Tc-99m DTPA. Initial uptake of Tc-99m MAG3 was well correlated with, and about threefold that, of Tc-99m DTPA. It was suggested that initial renal uptake of Tc-99m MAG3 may be an alternative to that of Tc-99m DTPA, with less dependence on background correction in evaluating differential renal function.

Gamma Cameras↗

[MR imaging of pituitary dwarfism].

Pituitary MR imaging was performed in 32 patients with clinically diagnosed pituitary dwarfism and 12 normal controls. The patients were divided into two groups according to the severity of pituitary dwarfism based on endocrinological data. The two patients with severe dwarfism showed transection of the pituitary stalk, ectopic posterior lobe and atrophy of the anterior lobe on MR imaging, while the 27 patients with mild dwarfism showed no abnormal MR findings of the pituitary gland. The former group corresponds to typical pituitary dwarfism and the latter to partial GH deficiency, which was recently proposed as another type of pituitary dwarfism. In conclusion, pituitary MR imaging may differentiate partial GH deficiency from typical (stalk-transected) pituitary dwarfism.

Adolescent↗

Aortic regurgitation: quantitation with MR imaging velocity mapping.

Aortic regurgitation (AR) in five healthy volunteers and 26 patients (mean age, 60.3 years; range, 25-83 years) was quantitatively measured with magnetic resonance (MR) imaging velocity mapping. Cine transverse images of the ascending aorta (32 phases per cardiac cycle) were acquired by using a gradient-echo sequence with a velocity-encoding bipolar pulse applied in the section-selection direction with a 1.5-T MR imaging unit. The aortic flow was calculated by integrating the product of area and mean velocity of the ascending aorta at each phase over a cardiac cycle. The negative and positive velocity values indicated antegrade and regurgitant flow, respectively, which allowed calculation of forward and regurgitant flow. Inter- and intraobserver variation of regurgitant fraction (RF) measurement was small (r = .956, standard error of the estimate [SEE] = 1.2%, n = 31; and r = .998, SEE = 0.35%, n = 10, respectively). RF determined with MR imaging agreed well with Doppler echocardiographic (n = 26) and aortographic (n = 9) grading of AR. Reproducible, quantitative, and noninvasive measurement of AR is possible with MR velocity mapping.

Adult↗

[Dual-energy data acquisition for simultaneous 81mKr ventilation/99mTc-MAA perfusion SPECT: ventilation/perfusion ratio mapping in cross section].

Methods of simultaneous pulmonary ventilation/perfusion (V/Q) tomogram (SPECT) for V/Q ratio mapping were reported. Crosstalk was corrected by subtraction assuming crosstalk/signal ratio is constant for an individual examination. Crosstalk was reduced by 85% for that of 99mTc-to-81mKr window (R12), and by 83% for that of 81mKr-to-99mTc window (R21) in a phantom experiment. The R12 and R21 were 1.0-1.9% (mean 1.3%) and 34.6-55.3% (mean 41.9%), respectively in 9 patients (mean age, 56.1 years; range, 38-82 years). V/Q SPECT was undertaken in 7 of the 9 patients. 99mTc-macroaggregated albumin (185 MBq) was injected intravenously in supine position, and 81mKr gas was administered continuously during the SPECT data acquisition. Sixty-four 64 x 64-matrix (size = 8 mm/pixel) images, 20-second acquisition time for each, were collected by a rotating gamma camera in a step-and-shoot fashion during a 360-degree rotation with the two photopeaks, one at 140 keV for 99mTc and another at 190 keV for 81mKr. Examination time was about 40 minutes, and the V/Q ratio maps in cross section were obtained in all of the examinations.

Adult↗

[Radionuclide studies of atherosclerosis].

New Tc-99m-labeled brain perfusion imaging agents, such as Tc-99m-HMPAO, and Tc-99m-ECD, are developed and expected to improve the clinical study of cerebral perfusion disturbance due to arteriosclerosis. They enable us better images than I-123-IMP and more accurate diagnosis. Similarly, in the field of cardiovascular nuclear medicine, new Tc-99m-labeled compounds, Tc-99m-MIBI, Teboroxime and Tetrofosmin are available. Furthermore, I-123-MIBG, a tracer taken up in presynaptic adrenergic vesicles, and I-123-BMIPP, a new agent developed for the evaluation myocardial fatty acid metabolism, will mark a new epoch in the study of coronary sclerosis. In order to image atherosclerosis directly, In-111-polyclonal immunoglobulin G, Tc-99m-low density lipoprotein etc., are under investigation.

Amphetamines↗

[Comparison between 180 degrees and 360 degrees data collection in 99mTc-Tetrofosmin SPECT of the myocardium].

We compared 360 degrees data collection technique with 180 degrees technique in SPECT using a new myocardial perfusion imaging agent, 99mTc-Tetrofosmin. Eight patients were examined at stress and at rest on separate days. Following the injection of 555 MBq 99mTc-Tetrofosmin, 64 views of 15 sec each were collected during a 360 degrees rotation, and 32 views of 30 sec each during a 180 degrees rotation. The 180 degrees data collection provided superior images in sharpness in 14 of 16 scans. The interpretation was concordant in 123 of 128 regions (96.1%), and hypoperfusion was considered to be underestimated in 5 regions using the 360 degrees technique. It was suggested that the 180 degrees data collection technique is more effective in myocardial SPECT employing 99mTc-Tetrofosmin than the 360 degrees technique.

Aged↗

[Clearance of 99mTc-Tetrofosmin from the myocardium and the adjacent organs].

We studied clearance of a new myocardial perfusion imaging agent, 99mTc-Tetrofosmin, from the myocardium and the adjacent organs in nine patients. 99mTc-Tetrofosmin was injected intravenously at stress and at rest, and SPECT images were obtained 25 min and 120 min later. Anterior view images were also obtained 10 min and 150 min after the injection to compare the myocardial clearance with those from the liver and lung. Clearance from the liver was faster than those from the myocardium and lung. Washout rate calculated with SPECT was higher for the inferior wall than for the anterior wall and lateral wall (p < 0.05 at rest, N.S. at stress). The value was higher at stress in any region than at rest (the anterior wall and lateral wall, p < 0.01; the septum, p < 0.05; the inferior wall, N.S.). Washout rate for the anterior wall was 3.4 +/- 14.0% at rest and 18.0 +/- 10.6% at stress. The rate for the lateral wall was 2.7 +/- 22.5% at rest and 15.8 +/- 7.9% at stress. It was suggested that rapid hepatic clearance and high myocardial washout at stress may be important in determining the period between the injection of 99mTc-Tetrofosmin and the data acquisition for SPECT imaging.

Female↗

[Two-dimensional time-of-flight MR angiography of mediastinum and pulmonary hilar vessels: initial clinical experiences].

Two-dimensional time-of-flight magnetic resonance angiography (2D TOF MRA) of mediastinal and pulmonary hilar vessels was performed in 10 patients, seven men and three women with a mean age (range) of 65.7 (48-88) years. The rate of visualization of the vessels and the diagnostic ability of 2D TOF MRA were assessed in comparison with contrast-enhanced CT. A radiofrequency-spoiled gradient echo sequence (SPGR) was used during repeated breath-holding (8-27 seconds) in coronal (8 patients) and axial (2 patients) imaging planes on a 1.5 Tesla superconducting scanner under the following conditions: repetition time/echo time/flip angle/excitation: 25-33/7-8 ms/45 degrees/1, field-of-view: 30 x 30 cm, slice thickness: 2.5 mm, 32 slices, 256 (frequency) x 192 (phase) matrix, with gradient moment nulling technique. Visualization sufficient to enable diagnosis of the vascular lesion was obtained in 95 (52%) vessels, mere visualization in 63 (35%), and non-visualization in 24 (13%) of the 182 evaluable vessels. The rates of good visualization of pulmonary hilar vessels (26/86, 30%) and veins (26/48, 54%) were significantly lower than that of arteries (43/48, 90%, p < 0.05). The sensitivity and specificity of 2D TOF MRA were 77% (10/13) and 100% (83/83), respectively, in 96 evaluable vessels of nine patients. 2D TOF MRA of mediastium and pulmonary hili is clinically feasible, and may be useful because of its high specificity.

Aged↗

Value of three-dimensional surface display of brain perfusion imaging. Comparison with tomographic imaging.

The diagnostic ability of a three-dimensional surface display of I-123 IMP brain scintigrams and tomographic images was compared in 12 patients who underwent I-123 brain tomography for cerebral cortical hypoperfusion. Foci of decreased accumulation were independently diagnosed by four radiologists, first with transaxial images, second with three-dimensional images, and finally with both images subjectively compared for the purpose of diagnosing the existence, localization, and extent of lesions. Six different lesions (0 to 3 lesions/radiologist) were found only on the transaxial images, but 30 different lesions (1 to 14 lesions/radiologist) were found on the three-dimensional images. In 9 out of 12 cases, the three-dimensional images were regarded as superior for evaluating the extension of the lesion and for lesion existence and lesion localization in 5 out of 12 (P less than 0.05). In conclusion, a three-dimensional display of an I-123 IMP brain tomogram is superior to tomographic images in diagnosing the extent of cerebral cortical hypoperfusion. However, the display is not superior to tomographic images for diagnosing the existence and localization of hypoperfusion.

Amphetamines↗

[Activation of aerobic bacteria used as BOD measurement of seawater].

Waste of seawater used for cooling water for machines in some kinds of industries in a littoral district in Sakai City, comes under the application of BOD control of the pollution control ordinance in Osaka Prefecture. But unfortunately the BOD measurement method of seawater sample has not been established. In order to establish the measurement method, we studied the strength of activation of aerobic bacteria in the incubation water used and the dilution water. From our results it was proved that we can use the incubation seawater consisting of more than 10(3) cells/ml general bacteria count and more than 0.50 microgram/l ATP (Adenosin triphosphate) as the incubation water and the artificial seawater as the dilution water.

Adenosine Triphosphate↗

[A case of meningioma with non-accumulation of 99mTc-ECD and increased accumulation of 99mTc-HMPAO in the tumor].

99mTc-ECD SPECT and 99mTc-HMPAO SPECT with or without Matas test were performed in a 62-year-old woman with meningioma in the left anterior cranial fossa. After injection of 740 MBq 99mTc-ECD or HMPAO, 64 projection images were collected with a rotating Gamma camera. Matas test was carried out by compressing the left common carotid artery for about one minute immediately after RI injection. Although 99mTc-ECD SPECT showed non-accumulation in the tumor, 99mTc-HMPAO SPECT demonstrated increased accumulation in it. This area of increased accumulation disappeared on 99mTc-HMPAO SPECT with Matas test which causes decrease in blood flow of the tumor. These findings suggest 99mTc-ECD and 99mTc-HMPAO have a different mechanisms of accumulation in the meningioma.

Cysteine↗