Search PubMed⌕ Search

Biomedical subjects

T Katila

Publications and source records attributed to T Katila.

At least 55 records · Page 3Linked to original sources

Model extraction from magnetic resonance volume data using the deformable pyramid.

A general framework for automatic model extraction from magnetic resonance (MR) images is described. The framework is based on a two-stage algorithm. In the first stage, a geometrical and topological multiresolution prior model is constructed. It is based on a pyramid of graphs. In the second stage, a matching algorithm is described. This algorithm is used to deform the prior pyramid in a constrained manner. The topological and the main geometrical properties of the model are preserved, and at the same time, the model adapts itself to the input data. We show that it performs a fast and robust model extraction from image data containing unstructured information and noise. The efficiency of the deformable pyramid is illustrated on a synthetic image. Several examples of the method applied to MR volumes are also represented.

Algorithms↗

Freezing of stallion semen with addition of glycine betaine.

The effect of addition of glycine betaine to a lactose-EDTA freezing medium on the post-thaw motility of stallion semen was determined. The first three semen-rich fractions of nine stallions were collected with an open-end Krakow artificial vagina on consecutive weekdays. Semen was frozen using the Hannover method with freezing media containing glycine betaine in various concentrations from 0 to 5%. After thawing, sperm motility was analysed both by a light microscope and by a Hamilton-Thorn Motility Analyser. Total and progressive post-thaw motilities of semen containing 0.25-3% glycine betaine did not differ significantly from the total and progressive post-thaw motilities of semen frozen without glycine betaine. The total and progressive post-thaw motilities of semen containing 4 or 5% glycine betaine were significantly lower (P < 0.001) than those of semen without glycine betaine. In conclusion, glycine betaine did not show any beneficial effect on the post-thaw motility of stallion semen when semen was frozen using the Hannover method.

Animals↗

Bioelectromagnetic localization of a pacing catheter in the heart.

The accuracy of localizing source currents within the human heart by non-invasive magneto- and electrocardiographic methods was investigated in 10 patients. A non-magnetic stimulation catheter inside the heart served as a reference current source. Biplane fluoroscopic imaging with lead ball markers was used to record the catheter position. Simultaneous multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) recordings were performed during catheter pacing. Equivalent current dipole localizations were computed from MCG and BSPM data, employing standard and patient-specific boundary element torso models. Using individual models with the lungs included, the average MCG localization error was 7+/-3 mm, whereas the average BSPM localization error was 25+/-4 mm. In the simplified case of a single homogeneous standard torso model, an average error of 9+/-3 mm was obtained from MCG recordings. The MCG localization accuracies obtained in this study imply that the capability of multichannel MCG to locate dipolar sources is sufficient for clinical purposes, even without constructing individual torso models from x-ray or from magnetic resonance images.

Body Surface Potential Mapping↗

Reconstruction of 3-D geometry using 2-D profiles and a geometric prior model.

A method has been developed to reconstruct three-dimensional (3-D) surfaces from two-dimensional (2-D) projection data. It is used to produce individualized boundary element models, consisting of thorax and lung surfaces, for electro- and magnetocardiographic inverse problems. Two orthogonal projections are utilized. A geometrical prior model, built using segmented magnetic resonance images, is deformed according to profiles segmented from projection images. In our method, virtual X-ray images of the prior model are first constructed by simulating real X-ray imaging. The 2-D profiles of the model are segmented from the projections and elastically matched with the profiles segmented from patient data. The displacement vectors produced by the elastic 2-D matching are back projected onto the 3-D surface of the prior model. Finally, the model is deformed, using the back-projected vectors. Two different deformation methods are proposed. The accuracy of the method is validated by a simulation. The average reconstruction error of a thorax and lungs was 1.22 voxels, corresponding to about 5 mm.

Diagnostic Imaging↗

Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography.

This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies.

Adult↗

Magnetocardiographic QT interval dispersion in postmyocardial infarction patients with sustained ventricular tachycardia: validation of automated QT measurements.

QT dispersion is a measure of heterogeneity in ventricular repolarization. Increased ECG QT dispersion is associated with life-threatening ventricular arrhythmias. We studied if magnetocardiographic (MCG) measures of QT dispersion can separate postmyocardial infarction patients with and without susceptibility to sustained VT. Manual dispersion measurements were compared to a newly adapted automatic QT interval analysis method. Ten patients with a history of sustained VT (VT group) and eight patients without ventricular arrhythmias (Controls) were studied after a remote myocardial infarction. Single-channel MCGs were recorded from 42 locations over the frontal chest area and the signals were averaged. QT dispersion was defined as maximum-minimum or standard deviation of measured QT intervals. VT group showed significantly more QT and JT dispersion than Controls. QTapex dispersions were 127 +/- 26 versus 83 +/- 21 ms (P = 0.004) and QTend dispersions 130 +/- 37 versus 82 +/- 37 ms (P = 0.013), respectively. Automatic method gave comparable values. Their relative differences were 9% for QTapex and 27% for QTend dispersion on average. In conclusion, increased MCG QT interval dispersion seems to be associated with a susceptibility to VT in postmyocardial infarction patients. MCG mapping with automated QT interval analysis may provide a user independent method to detect nonhomogeneity in ventricular repolarization.

Algorithms↗

Nonfluoroscopic localization of an amagnetic catheter in a realistic torso phantom by magnetocardiographic and body surface potential mapping.

This study was performed to evaluate the accuracy of multichannel magnetocardiographic (MCG) and body surface potential mapping (BSPM) in localizing three-dimensionally the tip of an amagnetic catheter for electrophysiology without fluoroscopy. An amagnetic catheter (AC), specially designed to produce dipolar sources of different geometry without magnetic disturbances, was placed inside a physical thorax phantom at two different depths, 38 mm and 88 mm below the frontal surface of the phantom. Sixty-seven MCG and 123 BSPM signals generated by the 10 mA current stimuli fed into the catheter were then recorded in a magnetically shielded room. Non-invasive localization of the tip of the catheter was computed from measured MCG and BSPM data using an equivalent current dipole source in a phantom-specific boundary element torso model. The mean 3-dimensional error of the MCG localization at the closer level was 2 +/- 1 mm. The corresponding error calculated from the BSPM measurements was 4 +/- 1 mm. At the deeper level, the mean localization errors of MCG and BSPM were 7 +/- 4 mm and 10 +/- 2 mm, respectively. The results showed that MCG and BSPM localization of the tip of the AC is accurate and reproducible provided that the signal-to-noise ratio is sufficiently high. In our study, the MCG method was found to be more accurate than BSPM. This suggests that both methods could be developed towards a useful clinical tool for nonfluoroscopic 3-dimensional electroanatomical imaging during electrophysiological studies, thus minimizing radiation exposure to patients and operators.

Body Surface Potential Mapping↗

Magnetocardiographic pacemapping for nonfluoroscopic localization of intracardiac electrophysiology catheters.

The purpose of the study was to validate, in patients, the accuracy of magnetocardiography (MCG) for three-dimensional localization of an amagnetic catheter (AC) for multiple monophasic action potential (MAP) with a spatial resolution of 4 mm2. The AC was inserted in five patients after routine electrophysiological study. Four MAPs were simultaneously recorded to monitor the stability of endocardial contact of the AC during the MCG localization. MAP signals were band-pass filtered DC-500 Hz and digitized at 2 KHz. The position of the AC was also imaged by biplane fluoroscopy (XR), along with lead markers. MCG studies were performed with a multichannel SQUID system in the Helsinki BioMag shielded room. Current dipoles (5 mm; 10 mA), activated at the tip of the AC, were localized using the equivalent current dipole (ECD) model in patient-specific boundary element torso. The accuracy of the MCG localizations was evaluated by: (1) anatomic location of ECD in the MRI, (2) mismatch with XR. The AC was correctly localized in the right ventricle of all patients using MRI. The mean three-dimensional mismatch between XR and MCG localizations was 6 +/- 2 mm (beat-to-beat analysis). The co efficient of variation of three-dimensional localization of the AC was 1.37% and the coefficient of reproducibility was 2.6 mm. In patients, in the absence of arrhythmias, average local variation coefficients of right ventricular MAP duration at 50% and 90% of repolarization, were 7.4% and 3.1%, respectively. This study demonstrates that with adequate signal-to-noise ratio, MCG three-dimensional localizations are accurate and reproducible enough to provide nonfluoroscopy dependant multimodal imaging for high resolution endocardial mapping of monophasic action potentials.

Action Potentials↗

A new versatile PC-based lung sound analyzer with automatic crackle analysis (HeLSA); repeatability of spectral parameters and sound amplitude in healthy subjects.

A versatile PC-based lung sound analyzer has been developed for short-term recording and analysis of respiratory sounds in research and clinical applications. The system consists of two sound sensors, a flow sensor, a filtering signal amplifier and a PC with a data acquisition card and software for measurement and analysis of the sounds. The analyses include phonopneumography, time expanded waveform analysis, spectral analysis with time averaged Fast Fourier Transform, frequency analysis in time domain (sonogram), and automatic detection and waveform analysis of crackles. Short-term repeatability of spectral parameters of tracheal and lung sounds was studied in 10 healthy subjects. The coefficients of variation (CoV) of the averaged quartile frequencies (F25, F50 and F75) of lung sounds during flow-controlled tidal breathing were 3.7, 4.0 and 8.9% in expiration and 2.7, 3.5 and 4.5% in inspiration, respectively. CoVs of the averaged F25, F50 and F75 of expiratory tracheal sounds were 6.9, 3.0 and 2.4%, and those of inspiratory tracheal sounds 6.3, 2.6 and 3.3%, respectively. Examples of lung sound analysis of samples containing adventitious sounds such as crackles and wheezes are presented. The results indicate that the median frequency has the best repeatability of quartile frequencies of breath sounds and they suggest that the variations of those parameters are low enough for diagnostic purposes. The results also suggest that the analyzer can be a useful new tool for pulmonary research in the fields of physiological and clinical short-term studies of respiratory sounds.

Adult↗

Neuronal responses to magnetic stimulation reveal cortical reactivity and connectivity.

Motor and visual cortices of normal volunteers were activated by transcranial magnetic stimulation. The electrical brain activity resulting from the brief electromagnetic pulse was recorded with high-resolution electroencephalography (HR-EEG) and located using inversion algorithms. The stimulation of the left sensorimotor hand area elicited an immediate response at the stimulated site. The activation had spread to adjacent ipsilateral motor areas within 5-10 ms and to homologous regions in the opposite hemisphere within 20 ms. Similar activation patterns were generated by magnetic stimulation of the visual cortex. This new non-invasive method provides direct information about cortical reactivity and area-to-area neuronal connections.

Adult↗

Comparison of three containers used for the transport of cooled stallion semen.

Three containers commonly used to transport cooled equine semen (Equitainer, ExpectaFoal and a Swedish-designed semen-transport container, previously called the Salsbro Box and now called Equine Express) were compared, using four ejaculates from each of three stallions. Each ejaculate was diluted to a spermatozoal concentration of 25 x 10(6)/ml with a nonfat dry milk-glucose extender containing amikacin sulfate (1 mg/ml) and potassium penicillin G (1000 units/ml). Extended semen was divided into three 40-ml aliquots for placement in each of the three semen-transport containers. The extended semen was stored in the containers for 24 h prior to analysis. Stored semen was warmed for 15 min at 37 degrees C, then video records of sperm motility were obtained for evaluation using a Hamilton-Thorne motility analyzer equipped with a stage warmer set at 37 degrees C. The temperature of 40-ml aliquots of semen extender stored in each container was also measured for 60 h using a copper-constantan thermocouple placed in the center of the stored samples. Intervals from onset of storage until sample temperature exceeded 10 degrees C during the warming phase were 27.5, 33.5 and 53 h, for the Expecta-Foal, Equine Express and Equitainer, respectively. Semen extender stored in the Equitainer compared most favorably to ideal cooling rates and storage temperatures published previously. Following a 24-h storage period, the mean percentages of motile, progressively motile, and rapidly motile spermatozoa, as well as the mean spermatozoal curvilinear velocity were similar (P > 0.05) among the three containers.

Journal Article↗

Procedures for handling fresh stallion semen.

Handling procedures for semen to be used at the stud-farm and for transport are reviewed. Proper handling of semen is required throughout the entire process, from semen collection to the insemination of the mare. Semen shall not be exposed to mechanical damage, light, cold or heat. All equipment that comes in contact with semen must be warm, clean, dry and free from toxic residues. Skim-milk extender appears to be the medium best suited for the preservation of stallion semen during cooling and storage. When used immediately, semen is usually extended 1:1 (v:v), but for transport, concentrations of 25 to 100 x 10(6) spermatozoa/mL are recommended. The proportion of semen plasma should be reduced to < 20%. by centrifuging, by collecting only the first 3 sperm-rich fractions, or by substantially diluting of the ejaculate. The storage temperature can be between 20 to 15 degrees C, if shipment time is no more than 12 h; for longer storage, temperatures < 10 degrees C are recommended. Semen can be cooled rapidly from 35 to 19 degrees C. In the temperature zone between 19 and 8 degrees C, stallion spermatozoa are sensitive to cold shock, and the cooling rate should be slowed to 0.05 degrees C/min. Rapid cooling can be resumed below 8 degrees C. At low temperatures, removal of oxygen-rich air is beneficial for the survival of spermatozoa. The Equitainer transport container keeps a constant temperature of 5 degrees C for 48 h and is therefore recommended for transportation lasting over 24 h.

Journal Article↗

Accuracy of a registration procedure for brain SPET and MRI: phantom and simulation studies.

Phantom experiments and simulations were performed to evaluate the significance of different error sources in a clinical registration procedure for brain SPET and MRI based on external markers. The results from the phantom experiments were used to adjust the error model for simulations. In the phantom experiments, 13-14 external markers were attached to the surface of a three-dimensional brain phantom for computing registration. Three internal test markers were used to estimate the accuracy of registration. The phantom was imaged with two different SPET and MRI devices. The mean root-mean-squared (RMS) residual of the locations of the test markers after registration using different combinations of four external markers varied from 3.5 +/- 1.0 to 5.2 +/- 1.3 mm depending on the imaging equipment and parameters used. The accuracy improved with an increasing number of external markers, from 3.2 +/- 0.5 to 4.9 +/- 0.5 mm for 6 markers and from 3.1 +/- 0.1 to 4.7 +/- 0.1 mm for 13 markers. In simulations, the external markers had an error comparable to the corresponding error in the phantom experiments. The error in the test markers was varied independently of that of the external markers. When the locating error of the test markers was removed, about 2 mm of the residuals of the test markers were found to come from this source. When an error comparable to the resolution of the original images (7-10 mm for SPET, 2 mm for MRI) was included in the test markers, the largest mean RMS residual after registration was smaller than the resolution error (8.8 +/- 1.1 mm). This was due to the accuracy of localization of the external markers and the fact that the direction of the error was random for each marker. The size of the registration error of an image volume was site-dependent, being minimal near the centre of mass of the external markers. When comparing the error with the spatial resolution of SPET, it was concluded that the accuracy of registration is not the limiting factor in region-of-interest analysis of registered images, provided that the design and attachment of the marker system are appropriate.

Brain↗

Some effects of multiple administration of detomidine during the last trimester of equine pregnancy.

Detomidine was given to 11 pregnant mares at 3 week intervals during the last trimester of pregnancy. Maternal and fetal electrocardiographs were recorded and fetal activity studied by transabdominal ultrasonography, before and 2 h (2, 5, 10, 20, 30, 60, 90 and 120 min) after injection. After parturition, the foals were examined and weighed. Maternal and fetal heart rate showed an initial decline after detomidine administration. Maternal heart rate in the treatment group were lower already 2 min after injection, but a reduction in fetal heart was first seen 5 min after detomidine administration. Mean fetal heart rate at 2 min after detomidine injection was 109, 104, 95 and 90 beats/min, whereas at 5 min it was 80, 76, 72 and 66 beats/min in the 2nd, 3rd, 4th and 5th examination session, respectively. The heart rates did not revert to the control values during follow-up. Decline and recovery patterns were quite similar during all examination sessions. The mares exhibited conductive disturbances 2 min after detomidine administration, but fetal heart rhythm remained regular. Fetal activity was decreased at 5 min but had reverted to control values about 90 min after detomidine administration. Administration of detomidine (0.015 mg/kg) to healthy pregnant mares at 3 week intervals during the last trimester had no measurable detrimental effects on the outcome of pregnancy.

Analgesics↗

Effect of 19-norandrostenololylaurate on semen characteristics of colts.

The long-term effects of the anabolic steroid 19-norandrostenololylaurate on semen characteristics of Finnhorse colts were studied in 3 experiments. Semen was collected initially at 24 months of age and then twice a year. In experiment I, 500 mg or 100 mg of steroid per animal was given every 3rd week from 12 or 16 months to 24 months of age. In colts treated with 500 mg of anabolic steroid every 3rd week, azoospermia was observed in 3 out of 5 colts in the first semen collections, immediately after the end of treatment. The other 2 colts had low sperm numbers and a high percentage of proximal droplets in relation to control animals. The 100 mg group was less affected by steroid treatment than the 500 mg group. The seminal changes were observed to be reversible. All of the colts had spermatozoa in their ejaculates 4 months after the end of treatment. Two years after cessation of treatment, sperm numbers in treated animals exceeded those in the control group. In experiment II, colts were treated from 7 months to 12 months of age with a dose of 1 mg/kg every 3rd week or 0.3 mg/kg every week. The first semen collections took place 12 months after the last treatment. The animals treated with 0.3 mg/kg every week were less affected than those treated with 1 mg/kg every 3rd week. In experiment III, animals were treated from 3 months to 8 months of age, and the interval from the last treatment to the first semen collection was 16 months. There were no significant differences between the groups in any of the semen parameters examined. In the last semen collection, the control animals had numerically higher spermatozoal concentration and progressive motility and less dead sperm than the treated animals. It was concluded that the adverse effects of steroid treatment on semen characteristics were reversible, at least in the groups treated at age 7-25 months.

Aging↗

Effect of 19-norandrostenololylaurate on testicular growth in colts.

The effect of anabolic steroid on testicular growth was investigated in 3 experiments. In experiment I, 500 mg of the anabolic steroid was given to 4 colts and 100 mg to another 4 colts, every 3rd week, starting at age 16 months and ending at age 24 months. Six colts served as controls. Both treatments decreased total scrotal width (TSW) within 6 weeks. Seasonal testicular growth during spring partly overcame the effect of steroid treatment. Cessation of anabolic steroid treatment was followed by testicular growth at the same time as TSW in untreated colts was decreasing by virtue of the effect of the season. Four months after the last injection, TSW was smaller in the treated animals than in the untreated animals, but the difference was not statistically significant. In experiment II, steroid was given at a dose of 1 mg/kg every 3rd week to 4 colts and 0.3 mg/kg every week to 4 colts. Six colts served as controls. The animals were 7 months old at the start of treatment and 12 months old at the end of treatment. Treatments decreased testicular widths (TW), within 6-9 weeks. In this experiment, also, cessation of anabolic steroid treatment was followed by testicular growth. Twelve months after the last treatment, TW was smaller in treated than in untreated animals but the difference was not statistically significant. In experiment III, foals were used which were 3 months old at the start and 8 months old at the end of treatment. The steroid was given at a dose of 1 mg/kg every 3rd week to 3 foals. Three foals served as controls. Treatment decreased TW within 6 weeks. Cessation of treatment was followed by a slow testicular growth. Growth similar to that in control animals started after a delay of 4-5 months. TW in treated animals nearly reached TW in controls within 12 months of cessation of treatment.

Aging↗