Online CE-MALDI-TOF MS using a rotating ball interface.

We report on the construction and performance of a rotating ball interface for online coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption ionization (MALDI) mass spectrometry with a time-of-flight (TOF) mass analyzer. The interface is based on a rotating stainless steel ball that transports samples from atmospheric pressure to the high vacuum of the mass spectrometer for desorption and ionization. The sample is deposited directly from a 50-microm-i.d. separation capillary onto the 19-mm ball that is rotating at 0.03 to 0.3 rpm. The sample is mixed online with matrix flowing from a separate 50-microm-i.d. capillary. The sample deposit dries before it is rotated past a polymer gasket and into the laser ionization region. Cleaning of the interface is accomplished using solvent-saturated felt, which cleans the ball surface after it rotates out of the ionization chamber. On-line CE-MALDI is demonstrated, and the performance is evaluated with the analysis of a mixture of three peptides: [Lsy8] vasopressin, substance P, and neurotensin. The rotating ball interface to MALDI-TOF MS demonstrated mass detection limit in the high femtomole range. The interface has negligible memory effect and shows no significant electrophoretic peak broadening when operated under optimized conditions.

Electrochemistry↗

Cell transport via electromigration in polymer-based microfluidic devices.

Electrokinetic transport of Escherichia coli and Saccharomyces cerevisiae (baker's yeast) cells was evaluated in microfluidic devices fabricated in pristine and UV-modified poly(methyl methacrylate)(PMMA) and polycarbonate (PC). Chip-to-chip reproducibility of the cell's apparent mobilities (micro(app)) varied slightly with a RSD of approximately 10%. The highest micro(app) for baker's yeast cells was observed in UV-modified PC with 0.5 mM PBS (pH = 7.4), and the lowest was measured in pristine PMMA with 20 mM PBS (pH = 7.4). Baker's yeast in all devices migrated toward the cathode because of their smaller electrophoretic mobility compared to the EOF. In 0.5 mM and 1 mM PBS, E. coli cells migrated toward the anode in all cases, opposite to the direction of the EOF due to their larger electrophoretic mobility. E. coli cells in 20 mM PBS migrated toward the cathode, which indicated that the electrophoretic mobility of E. coli cells decreased at higher ionic strengths. Observed differential migrations of E. coli and baker's yeast cells in appropriately prepared polymer microchips were used as the basis for selective introduction into microfluidic devices of only one type of cell. As a working model, experiments were performed with E. coli and RBCs (red blood cells). RBCs migrated toward the cathode in pristine PMMA with 1 mM and 20 mM PBS (pH = 7.4), opposite to the direction of the E. coli cells. By judicious choice of the buffer concentration in which the cell suspension was prepared and the polymer material, RBCs or E. coli cells were selectively introduced into the microdevice, which was monitored via laser backscatter signals.

Cells↗

Multiplexed fluorescence detection in microfabricated devices with both time-resolved and spectral-discrimination capabilities using near-infrared fluorescence.

We examined the feasibility of using a two-color time-resolved detection scheme with microdevices for DNA sequencing applications. A home-built dual-color optical-fiber-based time-resolved near-infrared (IR) fluorescence microscope successfully coupled lifetime discrimination with color discrimination, increasing fluorescence multiplexing capabilities. The instrument was constructed by using two pulsed-diode lasers (680/780-nm excitation) and two avalanche photodiodes as the basic building blocks. The data were processed using electronics configured in a time-correlated single-photon counting format. The use of near-IR fluorescence detection greatly simplified the hardware and allowed low detection limits (< 0.1nM). We examined the separation of a single-base tract on a microchip and compared the performance with that of conventional capillary gel electrophoresis. The microchip was fabricated in glass and contained an effective separation length of 7.0 cm. It was found that, without incorporating a solid-phase reversible immobilization cleanup procedure, the calculated lifetime of the dye label on the microchip was longer and the standard deviation was larger than those of the same sample analyzed using capillary electrophoresis. Using cleanup steps, the accuracy and precision of the measurements improved. Lifetimes of four near-IR dyes (AlexaFluor680, IRD700, IRD800, and IRD40) used in this study were determined to be 986 ps (RSD=2.1%), 1551 ps (RSD=1.8%), 520 ps (RSD=3.3%), and 788 ps (RSD=4.9%), respectively, in a microchannel filled with poly(dimethylacrylamide) (POP-6) gel. The lifetimes calculated using maximum likelihood estimators provided favorable precision on the microchip, where small numbers of photocounts were collected. An M13mp18 template was sequenced on the microchip using a two-color two-lifetime format with POP-6 as the sieving polymer. Read lengths of 294 bp with calling accuracies of 90.8 and 83.7% were achieved in each color channel. The relatively low calling accuracy and the short read length resulted primarily from the short separation channel, which yielded low electrophoretic resolution.

DNA↗

Capillary and microelectrophoretic separations of ligase detection reaction products produced from low-abundant point mutations in genomic DNA.

Capillary gel electrophoresis (CGE) and polymer-based microelectrophoretic platforms were investigated to analyze low-abundant point mutations in certain gene fragments with high diagnostic value for colorectal cancers. The electrophoretic separations were carried out on single-stranded DNA (ssDNA) products generated from an allele-specific ligation assay (ligase detection reaction, LDR), which was used to screen for a single base mutation at codon 12 in the K-ras oncogene. The presence of the mutation generated a ssDNA fragment that was >40 base pairs (bp) in length, while the primers used for the ligation assay were <30 bp in length. Various separation matrices were investigated, with the success of the matrix assessed by its ability to resolve the ligation product from the large molar excess of unligated primers when the mutant allele was lower in copy number compared to the wild-type allele. Using CGE, LDR product models (44 and 51 bp) could be analyzed in a cross-linked polyacrylamide gel with a 1000-fold molar excess of LDR primers (25 bp) in approximately 45 min. However, when using linear polyacrylamide gels, these same fragments could not be detected due to significant electrokinetic biasing during injection. A poly(methylmethacrylate) (PMMA) microchip of 3.5 cm effective column length was used with a 4% linear polyacrylamide gel to analyze the products generated from an LDR. When the reaction contained a 100-fold molar excess of wild-type DNA compared to a G12.2D mutant allele, the 44 bp ligation product could be effectively resolved from unligated primers in under 120 s, nearly 17 times faster than the CGE format. In addition, sample cleanup was simplified using the microchip format by not requiring desalting of the LDR prior to loading.

Acrylic Resins↗

Near-infrared time-resolved fluorescence lifetime determinations in poly(methylmethacrylate) microchip electrophoresis devices.

High aspect-ratio microstructures were hot-embossed in polymer substrates with a molding tool fabricated using lithography/electroplating/forming (LIGA). The resulting devices were used for the electrophoretic separation of oligonucleotides labeled with near-infrared (near-IR) dyes. Near-IR time-resolved fluorescence was used as an identification method for the labeling dyes. The detection apparatus consisted of a pulsed laser diode operating at 680 nm, a single-photon avalanche diode, an integrated microscope, and a PC-board incorporating time-correlated single photon counting electronics. Investigation of the optical quality and amount of autofluorescence generated from different polymer substrates was carried out in the near-IR region for determining compatibility with time-resolved fluorescence. Our results revealed that of several poly(methylmethacrylate)(PMMA) substrates, brand Plexiglas offered minimal replication errors in the embossed features using appropriate embossing conditions with low background fluorescence contributions to the observed decay. Near-IR dye-labeled oligonucleotides were separated to determine the applicability of fluorescence lifetime discrimination between Cy5.5 (tauf = 930 ps) and IRD700 (tauf = 851 ps) labeling dyes during the microchip separation. These dyes were used to label T-fragments (thymine) of an M13mp18 ssDNA template. The DNA ladders were electrophoresed at 130 V/cm in a 4% linear polyacrylamide gel (LPA) gel matrix in a 9.5 cm long serpentine channel heated to 50 degrees C. The electropherogram revealed that the lifetimes could be accurately read well beyond 450 bases, although single-base pair resolution in the electropherogram was difficult to achieve due to potential solute-wall interactions in the polymer microdevice or the electroosmotic flow (EOF) properties of the device. The relative standard deviations secured for individual bands in the electropherogram were similar to those obtained using capillary gel electrophoresis, in spite of the lower load volume.

Electrophoresis, Microchip↗

Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments.

In this manuscript, we discuss the use of photoactivated polycarbonate (PC) for purification of dye-labeled terminator sequencing fragments using solid-phase reversible immobilization (SPRI) prior to gel electrophoretic sorting of these DNAs. An immobilization bed for the DNA purification was produced by exposing a posted microchannel to UV radiation, which induced a surface photooxidation reaction, resulting in the production of carboxylate groups. The immobilization microchannel contained microposts to increase the loading level of DNAs to improve signal intensity without the need for preconcentration. By suspending the sequencing cocktail in an immobilization buffer (TEG/ethanol), the DNA fragments demonstrated a high affinity for this carboxylated surface. The loading density of DNAs to this activated surface was found to be 3.9 pmol cm(-2). The captured DNA could be subsequently released from the surface by incubation with ddH2O. SPRI cleanup of dye-terminator sequencing fragments using the photoactivated PC chip and slab gel electrophoresis produced a read length comparable to the conventional SPRI format, which utilized carboxylated magnetic beads and a magnetic field. The read length for the PC-SPRI format was found to be 620 bases with a calling accuracy of 98.9%. The PC-SPRI cleanup format was also integrated to a capillary gel electrophoresis (CGE) system. The PC-SPRI method was shown to effectively remove excess dye terminator from the CGE tract, but yielded lower plate numbers, as compared to a direct injection method with purification accomplished off-chip. The loss in efficiency was found to result primarily from the extended injection time associated with the microchip purification method.

Base Sequence↗

Approaching real-time molecular diagnostics: single-pair fluorescence resonance energy transfer (spFRET) detection for the analysis of low abundant point mutations in K-ras oncogenes.

The aim of this study was to develop new strategies for analyzing molecular signatures of disease states approaching real-time using single pair fluorescence resonance energy transfer (spFRET) to rapidly detect point mutations in unamplified genomic DNA. In addition, the detection process was required to discriminate between normal and mutant (minority) DNAs in heterogeneous populations. The discrimination was carried out using allele-specific primers, which flanked the point mutation in the target gene and were ligated using a thermostable ligase enzyme only when the genomic DNA carried this mutation. The allele-specific primers also carried complementary stem structures with end-labels (donor/acceptor fluorescent dyes, Cy5/Cy5.5, respectively), which formed a molecular beacon following ligation. We coupled ligase detection reaction (LDR) with spFRET to identify a single base mutation in codon 12 of a K-ras oncogene that has high diagnostic value for colorectal cancers. A simple diode laser-based fluorescence system capable of interrogating single fluorescent molecules undergoing FRET was used to detect photon bursts generated from the molecular beacon probes formed upon ligation. LDR-spFRET provided the necessary specificity and sensitivity to detect single-point mutations in as little as 600 copies of human genomic DNA directly without PCR at a level of 1 mutant per 1000 wild type sequences using 20 LDR thermal cycles. We also demonstrate the ability to rapidly discriminate single base differences in the K-ras gene in less than 5 min at a frequency of 1 mutant DNA per 10 normals using only a single LDR thermal cycle of genomic DNA (600 copies). Real-time LDR-spFRET detection of point mutations in the K-ras gene was accomplished in PMMA microfluidic devices using sheath flows.

Codon↗

Fluorescence multiplexing with time-resolved and spectral discrimination using a near-IR detector.

We report on the design and performance of a two-color, time-resolved detector for the acquisition of both steady-state and time-resolved fluorescence data acquired in real time during the capillary gel electrophoresis separation of DNA sequencing fragments. The detector consisted of a pair of pulsed laser diodes operating at 680 and 780 nm. The diode heads were coupled directly to single-mode fibers, which were terminated into a single fiber mounted via a FC/PC connector to the detector body. The detector contained a dichroic filter, which directed the dual-laser beams to an objective. The objective focused the laser light into a capillary gel column and also collected the resulting fluorescence emission. The dual-color emission was transmitted through the dichroic and focused onto a multimode fiber (core diameter 50 microm), which carried the luminescence to a pair of single-photon avalanche diodes (SPADs). The emission was sorted spectrally using a second dichroic onto one of two SPADs and isolated using appropriate interference filters (710- or 810-nm channel). The dual-color detector demonstrated a time response of 450 and 510 ps (fwhm) for the 710- and 810-nm channels, respectively. The mass detection limits for two near-IR dye-labeled sequencing primers electrophoresed in a capillary gel column were found to be 7.1 x 10(-21) and 3.2 x 10(-20) mol (SNR = 3) for the 710- and 810-nm detector channels, respectively. In addition, no leakage of luminescence excited at 680 nm was observed in the 810-nm channel or 780-nm excited luminescence into the 710-nm channel. An M13mp18 template was sequenced in a single capillary gel column using a two-color, two-lifetime format. The read length was found to be 650 base pairs for the test template at a calling accuracy of 95.1% using a linear poly(dimethylacrylamide) (POP6) gel column, with the read length determined primarily by the electrophoretic resolution produced by the sieving gel.

DNA, Viral↗

Microarrays assembled in microfluidic chips fabricated from poly(methyl methacrylate) for the detection of low-abundant DNA mutations.

Low-density arrays were assembled into microfluidic channels hot-embossed in poly(methyl methacrylate) (PMMA) to allow the detection of low-abundant mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. Following spotting, the chip was assembled with a cover plate and the array accessed using microfluidics in order to enhance the kinetics associated with hybridization. The array was configured with zip code sequences (24-mers) that were complementary to sequences present on the target. The hybridization targets were generated using an allele-specific ligase detection reaction (LDR), in which two primers (discriminating primer that carriers the complement base to the mutation being interrogated and a common primer) that flank the point mutation and were ligated joined together) only when the particular mutation was present in the genomic DNA. The discriminating primer contained on its 5'-end the zip code complement (directs the LDR product to the appropriate site of the array), and the common primer carried on its 3' end a fluorescent dye (near-IR dye IRD-800). The coupling chemistry (5'-amine-containing oligonucleotide tethered to PMMA surface) was optimized to maximize the loading level of the zip code oligonucleotide, improve hybridization sensitivity (detection of low-abundant mutant DNAs in high copy numbers of normal sequences), and increase the stability of the linkage chemistry to permit re-interrogation of the array. It was found that microfluidic addressing of the array reduced the hybridization time from 3 h for a conventional array to less than 1 min. In addition, the coupling chemistry allowed reuse of the array > 12 times before noticing significant loss of hybridization signal. The array was used to detect a point mutation in a K-ras oncogene at a level of 1 mutant DNA in 10,000 wild-type sequences.

DNA↗

Contact conductivity detection in poly(methyl methacrylate)-based microfluidic devices for analysis of mono- and polyanionic molecules.

An on-column contact conductivity detector was developed for the analysis of various mono- and polyanionic compounds separated by electrophoresis chips fabricated in poly(methyl methacrylate) (PMMA) using hot embossing techniques from Ni electroforms. The detector consisted of a pair of Pt wires (127 microm diameter) with an end-to-end spacing of approximately 20 microm and situated within the fluidic channel. The waveform applied to the electrode pair was a bipolar pulse with a frequency of 5.0 kHz and was used to reduce the charging current from measurement so that the current recorded at the end of one pulse is more representative of the solution conductivity. Using the detector, separations of amino acids, peptides, proteins, and oligonucleotides were demonstrated. For the amino acids and peptides, free-solution zone electrophoresis was performed. A calibration plot for the amino acid alanine was found to be linear from approximately 10 to 100 nM in a carrier electrolyte consisting of 10 mM triethylamonium acetate. The concentration detection limit was found to be 8.0 nM, with the corresponding mass detection limit equal to 3.4 amol (injection volume = 425 pL). The protein separations with conductivity detection were performed using MEKC, in which the carrier electrolyte contained the anionic surfactant sodium dodecyl sulfate (SDS) above its cmc. Near baseline resolution was achieved in the PMMA microchip for a solution containing 8 different proteins. In the case of the DNA fragments, capillary electrochromatography was used with a C18-modified PMMA chip and a carrier electrolyte containing an ion-pairing agent.

Amino Acids↗

Microfluidic devices fabricated in poly(methyl methacrylate) using hot-embossing with integrated sampling capillary and fiber optics for fluorescence detection.

High-aspect-ratio microstructures have been prepared using hot-embossing techniques in poly(methyl methacrylate) (PMMA) from Ni-based molding dies prepared using LIGA (Lithographie, Galvanoformung, Abformung). Due to the small amount of mask undercutting associated with X-ray lithography and the high energy X-ray beam used during photoresist patterning, deep structures with sharp and smooth sidewalls have been prepared. The Ni-electroforms produced devices with minimal replication errors using hot-embossing at a turn around time of approximately 5 min per device. In addition, several different polymers (with different glass transition temperatures) could be effectively molded with these Ni-electroforms and many devices (>300) molded with the same master without any noticeable degradation. The PMMA devices consisted of deep and narrow channels for insertion of a capillary for the automated electrokinetic loading of sample into the microfluidic device and also, a pair of optical fibers for shuttling laser light to the detection zone and collecting the resulting emission for fluorescence analysis. Electrophoretic separations of double-stranded DNA ladders Phi X174 digested with Hae III) were performed with fluorescence detection accomplished using near-IR excitation. It was found that the narrow width of the channels did not contribute significantly to electrophoretic zone broadening and the plate numbers generated in the extended length separation channel allowed sorting of the 271/281 base pair fragments associated with this sizing ladder when electrophoresed in methylcellulose entangled polymer solutions. The dual fiber detector produced sub-attomole detection limits with the entire detector, including laser source, electronics and photon transducer, situated in a single box measuring 3'' x 10" x 14".

Dinitrobenzenes↗

Optimization of sequencing conditions using near-infrared lifetime identification methods in capillary gel electrophoresis.

We have investigated the sample preparation and electrophoresis conditions necessary to prepare DNA sequencing samples appropriate for use with near-infrared (IR) fluorescent labels with dye identification accomplished via lifetime techniques. It was found that several sample preparation protocols required attention to maximize the fluorescence yields of the labeling dyes, such as thermal cycling conditions, choice of counter ion used for the ethanol precipitation step and also, dye-primer versus dye-terminator chemistries. In addition, several different sieving matrices were investigated for their effects on both the fluorescence properties of the labeling dyes and electrophoretic resolution. Extended times used for the high temperature denaturing of duplexed DNA fragments during cycle sequencing produced cleavage products, in which the covalently attached dye to the sequencing primer was released through attack by dithiothreitol (DTT). Even under optimized thermal cycling conditions, free dye was generated that masked readable data from the sequencing traces. Ethanol precipitation was necessary to remove this free dye with the proper choice of counter ion (sodium). The results using different sieving matrices indicated that linear polyacrylamides (LPAs) were appropriate for any fluorescence measurement, since they could readily be replaced between runs minimizing deleterious memory effects associated with cross-linked polyacrylamide gels. After investigation of several different sieving LPAs, the commercially available POP6 was found to be particularly attractive, since it produced good electrophoretic resolution, single exponential behavior for the near-IR dye series investigated herein, and also, discernible lifetime differences within the dye set. Finally, dye-terminator chemistry was also found to minimize bleeding in the gel matrix produced by large amounts of unextended dye-primer within the gel lane.

Acrylic Resins↗

Contact conductivity detection of polymerase chain reaction products analyzed by reverse-phase ion pair microcapillary electrochromatography.

We describe the development of an integrated microelectrophoretic system consisting of a contact conductivity detector mounted on-chip for monitoring the separation of double-stranded (ds) DNA fragments produced via the polymerase chain reaction (PCR) using microcapillary electrochromatography as the separation mode. The separation was carried out in a polymer-based microfluidic device, hot-embossed into poly(methylmethacrylate) (PMMA), whose walls were functionalized to produce a C(18)-terminated surface to act as the stationary phase (open channel format). The carrier electrolyte contained the ion-pairing agent, triethylammonium acetate (TEAA) to allow the separation to be carried out using reverse-phase ion-pair capillary electrochromatography (RP-IPCEC). The microelectrophoretic separations were investigated utilizing various solvent strengths (acetonitrile/water) with 25 mM TEAA to observe the effects on the separation efficiency as well as the chromatographic development time and detector performance. The field strength significantly affected the quality of the separation, with no separation observed at 333 V/cm for a low mass dsDNA sizing ladder, but baseline separation achieved using a field strength of 67 V/cm. It was observed that the solvent strength affected the retention behavior of the polyanionic molecules as well as the electroosmotic mobility. Higher acetonitrile compositions in the run buffer resulted in reduced plate numbers, which produced lower chromatographic resolution. The use of conductivity detection allowed mass detection sensitivities in the range of 10(-21) mol with a separation efficiency of 10(4) plates and the performance of the detector independent of the acetonitrile content used in the carrier electrolyte.

Acetonitriles↗

Surface modification and characterization of microfabricated poly(carbonate) devices: manipulation of electroosmotic flow.

Poly(carbonate), PC, surfaces are chemically modified by treatment with sulfur trioxide gas. Sulfur trioxide gas sulfonates the aromatic rings of the poly(carbonate) surfaces, making the surfaces more hydrophilic. Sulfonation of the poly(carbonate) surface is confirmed by infrared spectroscopy. The modified polymer surfaces are found to be smoother in comparison to their unmodified counterparts, as noted by scanning force microscopy. The effects of the surface modification on electroosmotic flow are studied at a pH range of 4-10. The electroosmotic flow in sulfonated poly(carbonate) microchannels was found to be significantly higher than that in unmodified poly(carbonate) microchannels at pH values below 8.

Electrophoresis↗

BioMEMS using electrophoresis for the analysis of genetic mutations.

Biomedical microelectromechanical systems (BioMEMS) are rapidly emerging in many areas of genetic analysis. These devices demonstrate potential for rapid analysis using modular components capable of sample purification, amplification, mutation discrimination and detection on small, portable point-of-care instruments. Here, various approaches to genetic mutation detection and the modern analysis platform, capillary electrophoresis, will be briefly reviewed. Microfluidic devices will be discussed in relation to fabrication techniques, mutation detection using simple electrophoretic separations, multiplexed designs and modular functionalities, as well as challenges and issues surrounding this technology.

Base Sequence↗

Asymmetrical, water-soluble phthalocyanine dyes for covalent labeling of oligonucleotides.

Two new water-soluble, porphyrazine (Pz) dyes containing an isothiocyanate function for covalent linking have each been prepared by cross condensation of two different aromatic dinitriles, one containing carboxylates for solubilizing purposes and the other containing a nitro group for conversion into the labeling function. The initial mononitrotricarboxylato Pzs have been purified to homogeneity from the mixture of Pz congeners formed in the condensation reaction by anion exchange chromatography. The phthalocyanine dye 1 has an absorption maxima at 683 nm while the trinaphthoporphyrazine dye 2 has an absorption maxima at 755 nm, due to the increased size of the aromatic system. Both dyes were successfully conjugated to oligonucleotide primers, showing their potential for use in near-infrared-based DNA diagnostic applications.

Chromatography, High Pressure Liquid↗