We report here on the use of a polymer-based continuous flow thermal cycler (CFTC) microchip for Sanger cycle sequencing using dye terminator chemistry. The CFTC chip consisted of a 20-loop spiral microfluidic channel hot-embossed into polycarbonate (PC) that had three well-defined temperature zones poised at 95, 55, and 60 degrees C for denaturation, renaturation, and DNA extension, respectively. The sequencing cocktail was hydrodynamically pumped through the microreactor channel at different linear velocities ranging from 1 to 12 mm/s. At a linear velocity of 4 mm/s resulting in a 36-s extension time, a read length of >600 bp could be obtained in a total reaction time of 14.6 min. Further increases in the flow rate resulted in a reduction in the total reaction time but also produced a decrease in the sequencing read length. The CFTC chip could be reused for subsequent sequencing runs (>30) with negligible amounts of carryover contamination or degradation in the sequencing read length. The CFTC microchip was subsequently coupled to a solid-phase reversible immobilization (SPRI) microchip made from PC for purification of the DNA sequencing ladders (i.e., removal of excess dye-labeled dideoxynucleotides, DNA template, and salts) prior to gel electrophoresis. Coupling of the CFTC chip to the SPRI microchip showed read lengths similar to that obtained from benchtop instruments but did not require manual manipulation of the cycle sequencing reactions following amplification.
Microarray technologies provide powerful tools for biomedical researchers and medicine, since arrays can be configured to monitor the presence of molecular signatures in a highly parallel fashion and can be configured to search either for nucleic acids (DNA microarrays) or proteins (antibody-based microarrays) as well as different types of cells. Microfluidics on the other hand, provides the ability to analyze small volumes (micro-, nano- or even pico-liters) of sample and minimize costly reagent consumption as well as automate sample preparation and reduce sample processing time. The marriage of microarray technologies with the emerging field of microfluidics provides a number of advantages such as, reduction in reagent cost, reductions in hybridization assay times, high-throughput sample processing, and integration and automation capabilities of the front-end sample processing steps. However, this potential marriage is also fraught with some challenges as well, such as developing low-cost manufacturing methods of the fluidic chips, providing good interfaces to the macro-world, minimizing non-specific analyte/wall interactions due to the high surface-to-volume ratio associated with microfluidics, the development of materials that accommodate the optical readout phases of the assay and complete integration of peripheral components (optical and electrical) to the microfluidic to produce autonomous systems appropriate for point-of-care testing. In this review, we provide an overview and recent advances on the coupling of DNA, protein and cell microarrays to microfluidics and discuss potential improvements required for the implementation of these technologies into biomedical and clinical applications.
To build highly specific surfaces using aptamer affinity reagents, the effects of linker and coadsorbents were investigated for maximizing target binding and specificity for aptamer-based self-assembled monolayers (SAMs) supported on gold. An aptamer that binds the protein thrombin was utilized as a model system to compare different mixed monolayer systems toward maximizing binding and selectivity to the immobilized aptamer. Important factors used to optimize binding characteristics of thrombin to the aptamer-based monolayer films include changes in design elements of the linker and different coadsorbent thiols. Binding events measured by surface plasmon resonance (SPR) and ellipsometry showed that the binding performance of the aptamer SAMs depends principally on the linker and to a lesser extent on the coadsorbent. SAMs formed with HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-aptamer exhibited a 4-fold increase in binding capacity versus SAMs made using HS-(CH2)6-TTTTT-aptamer. Furthermore, SAMs made using HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-aptamer showed nearly complete specificity for thrombin versus bovine serum albumin (BSA, less than 2% bound), while a SAM incorporating a random DNA fragment (HS-(CH2)6-OP(O)2O-(CH2CH2O)6-TTTTT-RANDOM) showed little binding of thrombin. Irrespective of the aptamer-linker system, use of HS-(CH2)11(OCH2CH2)3OH, referred to as EG(3), as a coadsorbent enhanced binding of thrombin by approximately 2.5-fold compared to that of HS-(CH2)6-OH (mercaptohexanol, MCH).
We discuss the use of a photoactivated polycarbonate (PPC) microfluidic chip for the solid-phase, reversible immobilization (SPRI) and purification of genomic DNA (gDNA) from whole cell lysates. The surface of polycarbonate was activated by UV radiation resulting in a photo-oxidation reaction, which produced a channel surface containing carboxylate groups. The gDNA was selectively captured on this photoactivated surface in an immobilization buffer, which consisted of 3% polyethylene glycol, 0.4 M NaCl and 70% ethanol. The methodology reported herein is similar to conventional SPRI in that surface-confined carboxylate groups are used for the selective immobilization of DNA; however, no magnetic beads or a magnetic field are required. As observed by UV spectroscopy, a load of approximately 7.6 +/- 1.6 microg/ml of gDNA was immobilized onto the PPC bed. The recovery of DNA following purification was estimated to be 85 +/- 5%. The immobilization and purification assay using this PPC microchip could be performed within approximately 25 min as follows: (i) DNA immobilization approximately 6 min, (ii) chip washout with ethanol 10 min, and (iii) drying and gDNA desorption approximately 6 min. The PPC microchip could also be used for subsequent assays with no substantial loss in recovery, no observable carryover and no need for 'reactivation' of the PC surface with UV light.
The work presented herein describes highly efficient, two-dimensional (2D) electrophoretic separations of proteins in a PMMA-based microchip. Sodium dodecyl sulfate microcapillary gel electrophoresis (SDS micro-CGE) and micellar electrokinetic chromatography (MEKC) were used as the separation modes for the first and second dimension of the electrophoresis, respectively. The microchip was prepared by hot embossing into PMMA from a brass mold master fabricated via high-precision micromilling. The microchip incorporated a 30-mm SDS micro-CGE and a 10-mm MEKC dimension length. Electrokinetic injection and separation were used with field strengths of up to 400 V/cm. Alexa Fluor 633 conjugated proteins, ranging in size from 38 to 110 kDa, were detected using laser-induced fluorescence with excitation/emission at 633/652 nm. Average plate numbers (N) of 4.8 x 10(4) and 1.2 x 10(4) were obtained in the SDS micro-CGE and MEKC separation dimensions, respectively, for the investigated proteins corresponding to plate heights (H) of 0.62 and 0.87 microm. Effluents from the first dimension (SDS micro-CGE) were repetitively transferred into the second dimension every 0.5 s of run time in the first dimension with the electrophoresis run time in the MEKC dimension being 10 s. The 2D separation was performed on the investigated proteins in approximately 12 min and provided a peak capacity of approximately 1000.
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time=ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats.
With the growing number of fatalities resulting from the 100 or so cancer-related diseases, new enabling tools are required to provide extensive molecular profiles of patients to guide the clinician in making viable diagnosis and prognosis. Unfortunately with cancer-related diseases, there is not one molecular marker that can provide sufficient information to assist the clinician in making effective prognoses or even diagnoses. Indeed, large panels of markers must typically be evaluated that cut across several different classes (mutations in certain gene fragments--DNA; over/under-expression of gene activity as monitored by messenger RNAs; the amount of proteins present in serum or circulating tumor cells). The classical biosensor format (dipstick approach for monitoring the presence of a single element) is viewed as a valuable tool in many bioassays, but possesses numerous limitations in cancer due primarily to the single element nature of these sensing platforms. As such, if biosensors are to become valuable tools in the arsenal of the clinician to manage cancer patients, new formats are required. This review seeks to provide an overview of the current thinking on molecular profiling for diagnosis and prognosis of cancers and also, provide insight into the current state-of-the-art in the biosensor field and new strategies that must be considered to bring this important technology into the cancer field.
A novel method of photoresist-free micropatterning coupled with electroless gold plating is described for the fabrication of an integrated gold electrode for electrochemical detection (ED) on a polycarbonate (PC) electrophoresis microchip. The microelectrode layout was photochemically patterned onto the surface of a PC plate by selective exposure of the surface coated without photoresist to 254 nm UV light through a chromium/quartz photomask. Thus, the PC plate was selectively sensitized by formation of reactive chemical moieties in the exposed areas. After a series of wet chemistry reactions, the UV-exposed area was activated with a layer of gold nanoparticles that served as a seed to catalyze the electroless plating. The gold microelectrode was then selectively plated onto the activated area by using an electroless gold plating bath. Nonselective gold deposition on the unwanted areas was eliminated by sonication of the activated PC plate in a KSCN solution before electroless plating, and the adhesion of the plated electrodes to the PC surface was strengthened with thermal annealing. Compared with the previously reported electroless plating technique for fabrication of microelectrodes on a microchip, the present method avoided the use of a membrane stencil with an electrode pattern to restrict the area to be wet-chemically sensitized. The CE with integrated ED (CE-ED) microchip was assembled by thermal bonding an electrode-plated PC cover plate to a microchannel-embossed PC substrate. The novel method allows one to fabricate low-cost, electrode-integrated, complete PC CE-ED chips with no need of a clean room. The fabricated CE-ED microchip was demonstrated for separation and detection of model analytes, including dopamine (DA) and catechol (CA). Detection limits of 0.65 and 1.03 microM were achieved for DA and CA, respectively, and theoretical plate number of 1.4 x 10(4) was obtained for DA. The plated gold electrode can be used for about 4 h, bearing usually more than 100 runs before complete failure.
A suite of polymers were evaluated for their suitability as viable substrate materials for microchip electrophoresis applications, which were fabricated via replication technology. The relevant physiochemical properties investigated included the glass transition temperature (T(g)), UV-vis absorption properties, autofluorescence levels, electroosmotic flow (EOF) and hydrophobicity/hydrophilicity as determined by sessile water contact angle measurements. These physiochemical properties were used as a guide to select the proper substrate material for the intended microchip electrophoretic application. The T(g) of these polymers provided a guide for optimizing embossing parameters to minimize replication errors (REs), which were evaluated from surface profilometer traces. RE values ranged from 0.4 to 13.6% for the polymers polycarbonate (PC) and low-density polyethylene (LDPE), respectively. The absorption spectra and autofluorescence levels of the polymers were also measured at several different wavelengths. In terms of optical clarity (low absorption losses and small autofluorescence levels), poly(methyl methacrylate), PMMA (clear acrylic), provided ideal characteristics with autofluorescence levels comparable to glass at excitation wavelengths that ranged from 488-780 nm. Contact angle measurements showed a maximum (i.e., high degree of hydrophobicity) for polypropylene (PP), with an average contact angle of 104 degrees +/-3 degrees and a minimum exhibited by gray acrylic, G-PMMA, with an average contact angle of 27 degrees +/-2 degrees. The EOF was also measured for thermally assembled chips both before and after treatment with bovine serum albumin (BSA). The electrophoretic separation of a mixture of dye-labeled proteins including; carbonic anhydrase, phosphorylase B, beta-galactosidase, and myosin, was performed on four different polymer microchips using laser-induced fluorescence (LIF) excitation at 632.8 nm. A maximum average resolution of 5.04 for several peak pairs was found with an efficiency of 6.68 x 10(4) plates for myosin obtained using a BSA-treated PETG microchip.
We describe the microfabrication and operational characteristics of a simple flow-through biochip sensor capable of detecting low abundant point mutations in K-ras oncogenes from genomic DNA, which carry high diagnostic value for colorectal cancers. The biochip consisted of an allele-specific ligase detection reaction (LDR) coupled to a universal array for interrogating multiple mutations simultaneously from a clinical sample. The integrated sensing platform was micro-manufactured from two different polymers, polycarbonate, PC, which was used for the LDRs, and poly(methyl methacrylate), PMMA, which was used to build the microarray. Passive elements were hot embossed into the PC and PMMA microchips and then, the chips assembled into a three-dimensional architecture with the interconnect fabricated from an elastomer, poly(dimethylsiloxane), PDMS, to produce a leak-free connection between the biochips. The array in PMMA was produced using a photomodification process, which involved three steps; (1) UV (254 nm) exposure of the polymer surface; (2) EDC coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond) and; (3) washing of the surface. The LDR/hybridization flow-through biochip performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time=19.1 min) and could screen multiple mutations simultaneously for high throughput applications at a level of one mutant sequence in 100 wild-type sequences.
We report here the photochemical surface modification of poly(methyl methacrylate), PMMA, microfluidic devices by UV light to yield pendant carboxylic acid surface moieties. Patterns of carboxylic acid sites can be formed from the micrometer to millimeter scale by exposure of PMMA through a contact mask, and the chemical patterns allow for further functionalization of PMMA microdevice surfaces to yield arrays or other structured architectures. Demonstrated here is the relationship between UV exposure time and PMMA surface wettability, topography, surface functional group density, and electroosmotic flow (EOF) of aqueous buffer solutions in microchannels made of PMMA. It is found that the water contact angle on PMMA surfaces decreases from 70 degrees to 24 degrees after exposure to UV light as the result of the formation of carboxylic acid sites. However, upon rinsing with 2-propanol, the water contact angle increases to approximately 80 degrees , and this increase is attributed to changes in surface roughness resulting from removal of low molecular weight PMMA formed from scission events. In addition, the surface roughness and surface coverage of carboxylic acid groups exhibit a characteristic trend with UV exposure time. Electroosmotic flow (EOF) in PMMA microchannels increases upon UV modification and is pH dependent. The possible photolysis mechanism for formation of carboxylic acid groups on PMMA surfaces under the conditions outlined in this work is discussed.
We have fabricated a flow-through biochip assembly that consisted of two different microchips: (1) a polycarbonate (PC) chip for performing an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using an universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for the LDR in a continuous-flow format, in which two primers (discriminating primer that carried the complement base to the mutation being interrogated and a common primer) that flanked the point mutation and were ligated only when the particular mutation was present in the genomic DNA. The miniaturized reactor architecture allowed enhanced reaction speed due to its high surface-to-volume ratio and efficient thermal management capabilities. A PMMA chip was employed as the microarray device, where zip code sequences (24-mers), which were complementary to sequences present on the target, were microprinted into fluidic channels embossed into the PMMA substrate. Microfluidic addressing of the array reduced the hybridization time significantly through enhanced mass transport to the surface-tethered zip code probes. The two microchips were assembled as a single integrated unit with a novel interconnect concept to produce the flow-through microfluidic biochip. A microgasket, fabricated from an elastomer poly(dimethylsiloxane) with a total volume of the interconnecting assembly of <200 nL, was used as the interconnect between the two chips to produce the three-dimensional microfluidic network. We successfully demonstrated the ability to detect one mutant DNA in 100 normal sequences with the biochip assembly. The LDR/hybridization assay using the assembly performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time 19.1 min) and could screen multiple mutations simultaneously.
We have developed a simple ultraviolet (UV)-photomodification protocol using poly(methyl methacrylate) and polycarbonate to produce functional scaffolds consisting of carboxylic groups that allow covalent attachment of amine-terminated oligonucleotide probes to these surface groups through carbodiimide coupling. Use of the photomodification procedure coupled to microfluidics allowed for the rapid generation of medium-density DNA microarrays. The method reported herein involves the use of poly(dimethylsiloxane) microchannels reversibly sealed to photomodified poly(methyl methacrylate) surfaces to serve as stencils for patterning the oligonucleotide probes. After array construction, the poly(dimethylsiloxane) stencil is rotated 90 degrees to allow interrogation of the array using microfluidics. The photomodification process for array fabrication involves only three steps: (1) broadband UV exposure of the polymer surface, (2) carbodiimide coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond), and (3) washing of the surface. The density of probes attached to this activated surface was found to be approximately 41pmolcm(-2), near the steric-saturation limit for short oligonucleotide probes. We demonstrate the use of this procedure for screening multiple KRAS2 mutations possessing high diagnostic value for colorectal cancers. A ligase detection reaction/universal array assay was carried out using parallel detection of two different low-abundant DNA point mutations in KRAS2 oncogenes with the allelic composition evaluated at one locus. Four zip code probes immobilized onto the poly(methyl methacrylate) surface directed allele-specific ligation products containing mutations in the KRAS2 gene (12.2D, 12.2A, 12.2V, and 13.4D) to the appropriate address of a universal array with minimal amounts of cross-hybridization or misligation.
The ability to form patterns of chemically reactive surface functionalities in microanalytical devices using a simple photopatterning approach without the need for photoresist-based methods is described. Direct UV exposure of the surfaces of poly(methyl methacrylate), PMMA, and poly(carbonate), PC, microfluidic devices through optical masks leads to the production of patterns of near monolayer quantities of surface carboxylic acid groups as determined by surface coverage, X-ray photoelectron spectroscopy, and fluorescence microscopy experiments. Formation of the reactive carboxylic acid groups without significant physical (topographical) damage to the polymer device substrates is achieved by use of low UV fluence and exposure times. Modification of the patterned, surface carboxylic acid groups with metals, thermally responsive polymers, and antibodies results in microfluidic devices possessing metallic interconnects and detection electrodes and the ability to capture intact biological cells and proteins from solution.
This paper presents a novel method for DNA thermal amplification using the polymerase chain reaction (PCR) in an electrokinetically driven synchronized continuous flow PCR (EDS-CF-PCR) configuration carried out in a microfabricated polycarbonate (PC) chip. The synchronized format allowed patterning a shorter length microchannel for the PCR compared to nonsynchronized continuous flow formats, permitting the use of smaller applied voltages when the flow is driven electrically and also allowed flexibility in selecting the cycle number without having to change the microchip architecture. A home-built temperature control system was developed to precisely configure three isothermal zones on the chip for denaturing (95 degrees C), annealing (55 degrees C), and extension (72 degrees C) within a single-loop channel. DNA templates were introduced into the PCR reactor, which was filled with the PCR cocktail, by electrokinetic injection. The PCR cocktail consisted of low salt concentrations (KCl) to reduce the current in the EDS-CF-PCR device during cycling. To control the EOF in the PC microchannel to minimize dilution effects as the DNA "plug" was shuttled through the temperature zones, Polybrene was used as a dynamic coating, which resulted in reversal of the EOF. The products generated from 15, 27, 35, and 40 EDS-CF-PCR amplification cycles were collected and analyzed using microchip electrophoresis with LIF detection for fragment sizing. The results showed that the EDS-CF-PCR format produced results similar to that of a conventional block thermal cycler with leveling effects observed for amplicon generation after approximately 25 cycles. To the best of our knowledge, this is the first report of electrokinetically driven synchronized PCR performed on chip.
We report on the coupling of a polymer-based microfluidic chip to a MALDI-TOF MS using a rotating ball interface. The microfluidic chips were fabricated by micromilling a mold insert into a brass plate, which was then used for replicating polymer microparts via hot embossing. Assembly of the chip was accomplished by thermally annealing a cover slip to the embossed substrate to enclose the channels. The linear separation channel was 50 microm wide, 100 microm deep, and possessed an 8 cm effective length separation channel with a double-T injector (V(inj) = 10 nL). The exit of the separation channel was machined to allow direct contact deposition of effluent onto a specially constructed rotating ball inlet to the mass spectrometer. Matrix addition was accomplished in-line on the surface of the ball. The coupling utilized the ball as the cathode transfer electrode to transport sample into the vacuum for desorption with a 355 nm Nd:YAG laser and analyzed on a TOF mass spectrometer. The ball was cleaned online after every rotation. The ability to couple poly(methylmethacrylate) microchip electrophoresis devices for the separation of peptides and peptide fragments produced from a protein digest with subsequent online MALDI MS detection was demonstrated.
Continuous flow polymerase chain reaction (CFPCR) devices are compact reactors suitable for microfabrication and the rapid amplification of target DNAs. For a given reactor design, the amplification time can be reduced simply by increasing the flow velocity through the isothermal zones of the device; for flow velocities near the design value, the PCR cocktail reaches thermal equilibrium at each zone quickly, so that near ideal temperature profiles can be obtained. However, at high flow velocities there are penalties of an increased pressure drop and a reduced residence time in each temperature zone for the DNA/reagent mixture, that potentially affect amplification efficiency. This study was carried out to evaluate the thermal and biochemical effects of high flow velocities in a spiral, 20 cycle CFPCR device. Finite element analysis (FEA) was used to determine the steady-state temperature distribution along the micro-channel and the temperature of the DNA/reagent mixture in each temperature zone as a function of linear velocity. The critical transition was between the denaturation (95 degrees C) and renaturation (55 degrees C-68 degrees C) zones; above 6 mm s(-1) the fluid in a passively-cooled channel could not be reduced to the desired temperature and the duration of the temperature transition between zones increased with increased velocity. The amplification performance of the CFPCR as a function of linear velocity was assessed using 500 and 997 base pair (bp) fragments from lambda-DNA. Amplifications at velocities ranging from 1 mm s(-1) to 20 mm s(-1) were investigated. The 500 bp fragment could be observed in a total reaction time of 1.7 min (5.2 s cycle(-1)) and the 997 bp fragment could be detected in 3.2 min (9.7 s cycle(-1)). The longer amplification time required for detection of the 997 bp fragment was due to the device being operated at its enzyme kinetic limit (i.e., Taq polymerase deoxynucleotide incorporation rate).