Search PubMed⌕ Search

Biomedical subjects

Shuichi Takayama

Publications and source records attributed to Shuichi Takayama.

At least 19 recordsLinked to original sources

Quantitative measurement and control of oxygen levels in microfluidic poly(dimethylsiloxane) bioreactors during cell culture.

Microfluidic bioreactors fabricated from highly gas-permeable poly(dimethylsiloxane) (PDMS) materials have been observed, somewhat unexpectedly, to give rise to heterogeneous long term responses along the length of a perfused mammalian cell culture channel, reminiscent of physiologic tissue zonation that arises at least in part due to oxygen gradients. To develop a more quantitative understanding and enable better control of the physical-chemical mechanisms underlying cell biological events in such PDMS reactors, dissolved oxygen concentrations in the channel system were quantified in real time using fluorescence intensity and lifetime imaging of an oxygen sensitive dye, ruthenium tris(2,2'-dipyridyl) dichloride hexahydrate (RTDP). The data indicate that despite oxygen diffusion through PDMS, uptake of oxygen by cells inside the perfused PDMS microchannels induces an axial oxygen concentration gradient, with lower levels recorded in downstream regions. The oxygen concentration gradient generated by a balance of cellular uptake, convective transport by media flow, and permeation through PDMS in our devices ranged from 0.0003 (mg/l)/mm to 0.7 (mg/l)/mm. The existence of such steep gradients induced by cellular uptake can have important biological consequences. Results are consistent with our mathematical model and give insight into the conditions under which flux of oxygen through PDMS into the microchannels will or will not contribute significantly to oxygen delivery to cells and also provide a design tool to manipulate and control oxygen for cell culture and device engineering. The combination of computerized microfluidics, in situ oxygen sensing, and mathematical models opens new windows for microphysiologic studies utilizing oxygen gradients and low oxygen tensions.

Animals↗

The effect of continuous wavy micropatterns on silicone substrates on the alignment of skeletal muscle myoblasts and myotubes.

Tissue-engineered muscle is a viable option for tissue repair, though presently technologies are not developed enough to produce tissue in vitro identical to that in vivo. One important step in generating accurate engineered muscle is to mimic natural muscle architecture. Skeletal muscle is composed of fibrils whose organization defines functionality. In musculoskeletal myogenesis, aligning myoblasts in preparation for myotube formation is a crucial step. The ability to efficiently organize myoblasts to form aligned myotubes in vitro would greatly benefit efforts in muscle tissue engineering. This paper reports alignment of prefused and differentiated skeletal muscle cells in vitro by use of continuous micropatterned wavy silicone surfaces, with features sized 3, 6 and 12 microm in periodicity. Wave features with 6 microm periodicity produced the most healthy, aligned myoblasts. Alignment was found to be a function of plating density. Further growth on these substrates with aligned myoblasts promoted fusion, yielding healthy aligned myotubes. This method will be useful for applications in which differentiated myogenic cells need to be aligned unidirectionally as in the development of engineered muscle.

Animals↗

A surface-modified sperm sorting device with long-term stability.

Microfluidic devices fabricated from poly (dime- thylsiloxane) (PDMS) offer the ability to improve our biological and medical capabilities. Although PDMS offers a range of intriguing benefits for biomedical applications, the intrinsically hydrophobic nature of PDMS may impede with the tremendous potential of these devices. Here, we describe a PDMS-based sperm sorting device, which has been surface-modified via graft-co-polymerization of poly(ethylene glycol) methyl ether methacrylate to create a moderately hydrophilic and non-fouling surface. This process involves the exposure of PDMS to UV/ozone, which activates the PDMS surface to bond to the substrate and, at the same time, initiates the graft-co-polymerization from the PDMS surface. In this study, we confirmed long-term stability of surface-modified PDMS for up to 56 days based on Fourier transformation infrared spectroscopy (FTIR), contact angle measurements, and protein adsorption studies. Moreover, the applicability of our method to PDMS-based sperm sorting devices was demonstrated by successfully sorting human sperm.

Cell Culture Techniques↗

Microscale integrated sperm sorter.

This chapter describes the design and fabrication of a passively driven microfluidic sperm sorter using soft lithographic microfabrication techniques. This self-contained device can separate motile sperm from nonmotile sperm and other cellular debris. The sorting system is small (coin sized) and structurally simple. It comprises two inlets; two outlets; a sorting channel; and arrays of horizontally oriented reservoirs that function as passively driven, constant-flow-rate pumps. Sperm with higher motility are sorted out from the rest of the semen samples based on their ability to swim through interfaces between adjacent laminar streams into separate streamlines, whereas the nonmotile sperm and debris remain in their initial streamlines. The device, which we call a microscale integrated sperm sorter, does not rely on any external power sources or controllers and incorporates all sample loading and sorting functions necessary to prepare high-quality sperm for in vitro fertilization. This self-contained, inexpensive, and portable device may also be useful for developing convenient sperm motility assays that can be used at the point of care or at home.

Cell Separation↗

Handheld recirculation system and customized media for microfluidic cell culture.

A palm-sized microfluidic recirculation system and customized media enable simplified long-term culture and imaging of cells. The combination of bare Braille display modules, a leveled monolithic surface for complete chip mounting, and a transparent heater improved portability, mechanical stability and optical accessibility. Modification of basal culture media with Leibovitz's L-15 medium enabled an incubator-free culture of carbonate-dependent cells by eliminating the need for exogenous carbon dioxide. This capability is demonstrated through time-lapse recording of proliferation of C2C12 myoblasts and MC3T3-E1 osteoblasts for over 2 weeks in ambient atmosphere without medium exchange. The method opens up new possibilities for portable cell culture and for long-term continuous visual monitoring of cells.

Cell Culture Techniques↗

IVF within microfluidic channels requires lower total numbers and lower concentrations of sperm.

BACKGROUND: Microfluidic technology has been utilized in numerous biological applications specifically for miniaturization and simplification of laboratory techniques. We sought to apply microfluidic technology to murine IVF. METHODS: Microfluidic devices measuring 500 microm wide, 180 microm deep, and 2.25 cm in length were designed and fabricated using poly(dimethylsiloxane) (PDMS). Controls were standard centre-well culture dishes with 500 microl of media, half of which also contained PDMS as a material control. Denuded mouse oocytes were placed into microchannels or centre-well dish controls in groups of 10, then co-incubated overnight with epididymal mouse sperm at various concentrations. Fertilization was assessed and Fisher's exact test was used for statistical analysis (P < 0.05 significant). RESULTS: Fertilization rates between the two control groups (42%, no PDMS; 41%, with PDMS; not significant) were similar. Fertilization rates for denuded oocytes at standard mouse insemination sperm concentration (1 degrees 10(6) sperm/ml) was poorer in microchannels (12%) than controls (43%; P < 0.001). As insemination concentrations decreased, fertilization rates improved in microchannels with a plateau between 8 degrees 10(4) and 2 degrees 10(4) sperm/ml (4000-1000 total sperm). At these concentrations, combined fertilization rate for denuded oocytes was significantly higher in microchannels than centre-well dishes (27 versus 10%, respectively; P < 0.001), and was not significantly different from corresponding controls with a sperm concentration of 1 degrees 10(6) (37%; P = 0.06). CONCLUSIONS: Murine IVF can be conducted successfully within microfluidic channels. Lower total numbers and concentrations of sperm are required. Microfluidic devices may ultimately be useful in clinical IVF.

Animals↗

Computer-controlled microcirculatory support system for endothelial cell culture and shearing.

Endothelial cells (ECs) lining the inner lumen of blood vessels are continuously subjected to hemodynamic shear stress, which is known to modify EC morphology and biological activity. This paper describes a self-contained microcirculatory EC culture system that efficiently studies such effects of shear stress on EC alignment and elongation in vitro. The culture system is composed of elastomeric microfluidic cell shearing chambers interfaced with computer-controlled movement of piezoelectric pins on a refreshable Braille display. The flow rate is varied by design of channels that allow for movement of different volumes of fluid per variable-speed pump stroke. The integrated microfluidic valving and pumping system allowed primary EC seeding and differential shearing in multiple compartments to be performed on a single chip. The microfluidic flows caused ECs to align and elongate significantly in the direction of flow according to their exposed levels of shear stress. This microfluidic system overcomes the small flow rates and the inefficiencies of previously described microfluidic and macroscopic systems respectively to conveniently perform parallel studies of EC response to shear stress.

Cell Culture Techniques↗

Fabrication of reconfigurable protein matrices by cracking.

The interface between extracellular matrices and cells is a dynamic environment that is crucial for regulating important cellular processes such as signal transduction, growth, differentiation, motility and apoptosis. In vitro cellular studies and the development of new biomaterials would benefit from matrices that allow reversible modulation of the cell adhesive signals at a scale that is commensurate with individual adhesion complexes. Here, we describe the fabrication of substrates containing arrays of cracks in which cell-adhesive proteins are selectively adsorbed. The widths of the cracks (120-3,200 nm) are similar in size to individual adhesion complexes (typically 500-3,000 nm) and can be modulated by adjusting the mechanical strain applied to the substrate. Morphology of cells can be reversibly manipulated multiple times through in situ adjustment of crack widths and hence the amount of the cell-adhesive proteins accessible to the cell. These substrates provide a new tool for assessing cellular responses associated with exposure to matrix proteins.

Animals↗

Microfluidics for flow cytometric analysis of cells and particles.

This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvement of other components, replacement of conventional glass capillary-based fluidics with microfluidic sample handling systems operating in microfabricated structures enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this review, we present various efforts that take advantage of novel microscale flow phenomena and microfabrication techniques to build microfluidic cell analysis systems.

Animals↗

Computerized microfluidic cell culture using elastomeric channels and Braille displays.

Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: (i) rapid and efficient mixing between streams, (ii) multiple laminar flows with minimal mixing between streams, and (iii) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serum-containing media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for high-throughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use.

Audiovisual Aids↗

Arrays of horizontally-oriented mini-reservoirs generate steady microfluidic flows for continuous perfusion cell culture and gradient generation.

This paper describes the use of arrays of horizontally-oriented reservoirs to deliver liquids through microchannels at a constant flow rate over extended periods of time (hours to days). The horizontal orientation maintains a constant hydraulic pressure drop across microfluidic channels even as the volumes of liquids within the reservoirs change over time. For a given channel-reservoir system, the magnitude of the flow velocity depends linearly on the height difference between reservoirs. The simple structure and operation mechanism make this pumping system versatile. A one-inlet-one-outlet system was used to continuously deliver media for perfusion cell culture, and an array of inlet reservoirs coupled to an outlet reservoir via microchannels was used to drive flows of multiple laminar streams. The parallel pumping scheme conveniently generated various smooth and step concentration gradients, and allowed evaluation of the effect of colchicine on myoblasts. Since the reservoir arrays are configured to be compatible with commercialized multichannel pipettors designed for 96 well plate handling, this simple pumping scheme is envisioned to be broadly useful for medium to high throughput microfluidic perfusion cell culture assays, cell migration assays, multiple laminar flow drug tests, and any other applications needing multiple microfluidic streams.

Cell Culture Techniques↗

Reversible switching of high-speed air-liquid two-phase flows using electrowetting-assisted flow-pattern change.

This work is the first demonstration of electrical modulation of surface energy to reversibly switch dynamic high-speed gas-liquid two-phase microfluidic flow patterns. Manipulation of dynamic two-phase systems with continuous high-speed flows is complex and interesting due to the multiple types of forces that need to be considered. Here, distinct stable flow patterns are formed through a multipronged approach: both surface tension forces generated by surface chemistry modulation as well as viscous and inertial forces produced by fluid flows are employed. The novel fluidic actuation mechanism provides insights into better understanding microscale two-phase flow dynamics and offers new opportunities for the development of two-phase biochemical microsystems that are mechanically simple and operational at high speeds.

Air↗

Fabrication of microfluidic mixers and artificial vasculatures using a high-brightness diode-pumped Nd:YAG laser direct write method.

This paper describes a direct write laser technology, which is fast and flexible, for fabricating multiple-level microfluidic channels. A high brightness diode-pumped Nd-YAG laser with slab geometry was used for its excellent beam quality. Channels with flat walls and staggered herringbone ridges on the floor have been successfully fabricated and their ability to perform passive mixing of liquid is discussed. Also, a multi-width multi-depth microchannel has been fabricated to generate biomimetic vasculatures whose channel diameters change according to Murray's law, which states that the cube of the radius of a parent vessel equals the sum of the cubes of the radii of the daughters. The multi-depth architecture allows for flow patterns to resemble physiological vascular systems with lower overall resistance and more uniform flow velocities throughout the network compared to planar patterning techniques which generate uniformly thin channels. The ability to directly fabricate multiple level structures using relatively straightforward laser technology enhances our ability to rapidly prototype complex lab-on-a-chip systems and to develop physiological microfluidic structures for tissue engineering and investigations in biomedical fluidics problems.

Biomimetics↗

Passively driven integrated microfluidic system for separation of motile sperm.

This paper describes a self-contained integrated microfluidic system that can separate motile sperm from small samples that are difficult to handle using conventional sperm-sorting techniques. The device isolates motile sperm from nonmotile sperm and other cellular debris, based on the ability of motile sperm to cross streamlines in a laminar fluid stream. The device is small, simple, and disposable yet is an integrated system complete with sample inlets, outlets, sorting channel, and a novel passively driven pumping system that provides a steady flow of liquid; it requires no external power source or controls. The device fulfills a need in clinical settings where small amounts of sperm need to be sorted. It also opens the way for convenient bioassays based on sperm motility including at-home motile sperm tests.

Cell Separation↗

Selective chemical treatment of cellular microdomains using multiple laminar streams.

There are many experiments in which it would be useful to treat a part of the surface or interior of a cell with a biochemical reagent. It is difficult, however, to achieve subcellular specificity, because small molecules diffuse distances equal to the extent of the cell in seconds. This paper demonstrates experimentally, and analyzes theoretically, the use of multiple laminar fluid streams in microfluidic channels to deliver reagents to, and remove them from, cells with subcellular spatial selectivity. The technique made it possible to label different subpopulations of mitochondria fluorescently, to disrupt selected regions of the cytoskeleton chemically, to dislodge limited areas of cell-substrate adhesions enzymatically, and to observe microcompartmental endocytosis within individual cells. This technique does not require microinjection or immobilization of reagents onto nondiffusive objects; it opens a new window into cell biology.

Animals↗

Micro- and nanotechnologies for studying cellular function.

The study of complex biological systems requires methods to perturb the system in complex yet controlled ways to elucidate mechanisms and dynamic interactions, and to recreate in vivo conditions in flexible in vitro set-ups. This paper reviews recent advances in the use of micro- and nanotechnologies in the study of complex biological systems and the advantages they provide in these two areas. Particularly useful for controlling the chemical and mechanical microenvironments of cells is a set of techniques called soft lithography, whereby elastomeric materials are used to transfer and generate micro- and nanoscale patterns. Examples of some of the capabilities of soft lithography include the use of elastomeric stamps to generate micropatterns of protein and the use of elastomeric channels to localize chemicals with subcellular spatial resolutions. These types of biological micro- and nanotechnologies combined with mathematical modeling will propel our understandings of cellular and subcellular physiology to new heights.

Animals↗

Lateral propagation of EGF signaling after local stimulation is dependent on receptor density.

We analyzed lateral propagation of epidermal growth factor (EGF) signaling in single live COS cells following local stimulation, achieved by the use of laminar flows containing rhodamine-labeled EGF. The spatiotemporal pattern of EGF signaling was visualized by fluorescent indicators for Ras activation and tyrosine phosphorylation. Contrary to the findings in previous reports, both signals were localized to the stimulated regions in control COS cells expressing EGF receptor at the basal level. However, the signals spread over the entire cell when EGF receptors were overexpressed or when receptor/ligand endocytosis was blocked. We thus present evidence that ligand-independent propagation of EGF signaling occurs only when the receptor density on the plasma membrane is high, such as in carcinoma cells.

Animals↗

Isolation of motile spermatozoa from semen samples using microfluidics.

A microfluidic device was designed with two parallel laminar flow channels where non-motile spermatozoa and debris would flow along their initial streamlines and exit one outlet, whereas motile spermatozoa had an opportunity to swim into a parallel stream and exit a separate outlet. Motile sperm samples were prepared with density gradient separation (n = 5). Sperm motility was assessed the following day after exposing aliquots to polydimethylsiloxane (PDMS) used to construct the device. There was no difference in sperm motility when compared with unexposed aliquots (P > 0.05). Unprocessed semen samples (n = 10) were placed in wider channels and sperm motility and strict morphology were assessed from sorted outlets. Sperm motility increased from 44 +/- 4.5% to 98 +/- 0.4% (P < 0.05) and morphology increased from 10 +/- 1.05% to 22 +/- 3.3% (P < 0.05) following processing. Finally, density gradient prepared samples (n = 6) containing 5 x 10(6) motile spermatozoa/ml and 50 x 10(6) round immature germ cells/ml were sorted and assessed in a similar fashion. The ratio of motile spermatozoa to round immature germ cells in the wide inlet (1:10) was significantly improved in the thin outlet (33:1) (P < 0.05). This microfluidic device provides a novel method for isolating motile, morphologically normal spermatozoa from semen samples without centrifugation. This technology may prove useful in isolating motile spermatozoa from oligozoospermic samples, even with high amounts of non-motile gamete and/or non-gamete cell contamination. A movie sequence showing streaming and sorting of spermatozoa may be purchased for viewing on the internet at www.rbmonline.com/Article/847 (free to web subscribers).

Cell Separation↗