BACKGROUND CONTEXT: Spinal fusion has some adverse effects, such as nonunion and pain at the site of grafted bone, and fusion with rigid spinal instrumentation especially may have the possibility of increasing mechanical stress on the segments adjacent to the site of fusion. The theory of the Graf system is that it will decrease adjacent disc deterioration because of maintenance of regional lordosis with flexibility and restriction of the motion of unstable segments without rigid spinal fusion. PURPOSE: To assess the clinical and radiologic results of Graf stabilization for lumbar degenerative disorders with minimal or mild instability. STUDY DESIGN: This is a retrospective study examining the mid-term results of Graf stabilization. PATIENT SAMPLE: In total, 59 patients underwent Graf ligamentoplasty and adequate decompression from April 1993 to September 1997. The subjects were 30 men and 29 women, and the mean age at the time of surgery was 60.6 years, ranging from 23 to 82 years. The average follow-up period was 3 years and 5 months, ranging from 2 years to 5 years and 10 months. OUTCOME MEASURES: We evaluated the surgical results using a scoring system, a visual analog scale, and radiological measurements. METHODS: The results were assessed according to a clinical scoring system established by the Japanese Orthopaedic Association (JOA score) and ratings based on a visual analog scale. Through analysis of x-ray images, the sagittal alignment (regional lordosis) and the range of motion (ROM) of the stabilized segments were measured in all cases, and the percentage of segments slipping and posterior disc height were determined for 29 patients with degenerative spondylolisthesis. RESULTS: Clinical scores and low back pain ratings based on a visual analog scale were significantly improved at the time of final follow-up compared with the preoperative values. Regional alignment of the operative segments was maintained in lordosis at the time of final follow-up. Preoperative ROM was significantly reduced at the time of final follow-up. There were no statistical differences in percentage of slippage or percentage of posterior disc height between the final follow-up values and the preoperative values. CONCLUSIONS: Our clinical results indicate that the Graf system is a suitable treatment option for mild and early lumbar degenerative diseases with minimum flexion instability of less than 10 degrees.
A new metallic filter made from a stainless steel fiber has been under development. To evaluate biocompatibility of this filter, the authors compared cytokine production with that of stainless steel fibers and polyester fibers by using a mononuclear cell culture. Furthermore, adsorbed proteins on each fiber were identified by using sodium-dodecyl sulfate (SDS)-polyacrlyamide gel electrophoresis (PAGE). The levels of tumor necrosis factor (TNF)-alpha in the cultured supernatant without fibers as the control, with polyester fibers, and with stainless steel fibers were 28.1 +/- 8.1, 39.3 +/- 2.6, and 29.1 +/- 6.7 pg/ml, respectively. The levels of interleukin (IL)-1 beta were 7.6 +/- 3.2, 8.9 +/- 1.5, and 8.9 +/- 2.1 pg/ml, respectively. The IL-4 levels were less than 0.25 pg/ml, and the interferon-tau levels were less than 7.8 pg/ml in all three conditions. The amount of adsorbed proteins was 3.39 +/- 0.27 microgram/cm2 for the polyester fibers and 2.72 +/- 0.23 microgram/ cm2 for the stainless steel fibers. The protein bands adsorbed to the polyester fibers by SDS-PAGE analysis were observed at approximately 180, 120, 90, 76, 67, 59, 56, and 28 kd molecular weight. In contrast, the protein bands adsorbed to the stainless steel fibers were observed at 90, 76, 67, 62, 56, 28, and 12 kd molecular weight. Thus, the proteins adsorbed to the stainless steel fibers differed from those on the polyester fibers. By western blot analysis, the amounts of albumin, IgG tau chain, and fibronectin adsorbed on the stainless steel fibers were smaller than those on the polyester fibers. The results of this study suggest that the stainless steel fibers do not stimulate monocytes, Th1, and Th2 cells. In addition, lesser adsorption of IgG tau chain and fibronectin may indicate that the stainless steel is a superior material for anti thrombogenicity compared to polyester.
A new silicone hollow fiber membrane oxygenator for extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber, with a 300 microm outer diameter and a wall thickness of 50 microm. The hollow fibers were mechanically cross-wound on the flow distributor to achieve equal distribution of blood flow without changing the fiber shape. The housing, made of silicone coated acryl, was 236 mm long with an inner diameter of 60 mm. The surface area was 1.0 m2 for prototype 211, and 1.1 m2 for prototype 209. The silicone fiber length was 150 mm, and the silicone membrane packing density was 43% for prototype 211 and 36% for prototype 209. Prototype 211 has a priming volume of 208 ml, and prototype 209 has a priming volume of 228 ml. The prototype 211 oxygenator demonstrates a gas transfer rate of 120 +/- 5 ml/min (mean +/- SD) for O2 and 67 +/- 12 ml/min for CO2 under 2 L of blood flow and 4 L of O2 gas flow. Prototype 209 produced the same values. The blood side pressure drop was low compared with the silicone sheet oxygenator (Avecor, 1500ECMO). These results showed that this new oxygenator for ECMO had efficiency similar to the silicone sheet oxygenator that has a 50% larger surface area. These results suggest that the new generation oxygenator using an ultrathin silicone hollow fiber possesses sufficient gas transfer performance for long-term extracorporeal lung support.
A totally implantable centrifugal artificial heart has been developed. The plastic prototype, Gyro PI 601, passed 2 day hemodynamic tests as a functional total artificial heart, 2 week screening tests for antithrombogenicity, and 1 month system feasibility. Based on these results, a metallic prototype, Gyro PI 702, was subjected to in vivo left ventricular assist device (LVAD) studies. The pump system employed the Gyro PI 702, which has the same inner dimensions and the same characteristics as the Gyro PI 601, including an eccentric inlet port, a double pivot bearing system, and a magnet coupling system. The PI 702 is driven with the Vienna DC brushless motor actuator. For the in vivo LVAD study, the pump actuator package was implanted in the preperitoneal space in two calves, from the left ventricular apex to the descending aorta. Case 1 achieved greater than 9 month survival without any complications, at an average flow rate of 6.6 L/min with 10.2 W input power. Case 2 was killed early due to the excessive growth of the calf, which caused functional obstruction of the inlet port. There was no blood clot inside the pump. During these periods, neither case exhibited any physiologic abnormalities. The PI 702 pump gives excellent results as a long-term implantable LVAD.
Heparin coating of cardiopulmonary bypass (CPB) circuitry may attenuate the platelet consumption associated with CPB. We investigated the effect of temperature on the interaction between platelet and heparin coated surfaces under in vitro static conditions. Heparin coated and non coated oxygenator fibers were incubated with heparinized whole blood at 37 degrees C and 22 degrees C. The incubation time was set at 30, 60, 180, and 300 minutes. The number of platelets adhering to each fiber was assessed with enzyme immunoassay using monoclonal antibody against platelet receptor protein CD 61(GPIIbIIIa). As an index of platelet activation, plasma soluble(s) P-selectin levels were measured by enzyme-linked immunosorbent assay. Under normothermia, the number of adherent platelets on the non coated surface increased significantly after 300 min of incubation. Platelet adhesion was reduced significantly by heparin coating of the surface and was kept constant after 300 min. Under hypothermia, heparin coating was also associated with significant reduction of platelet adhesion. The levels of sP-selectin did not correlate with the extent of platelet adhesion. Our results suggest that heparin coating is effective in decreasing platelet adhesion to the synthetic surface tested regardless of the temperature under static conditions. Inhibition of platelet activation on the heparin coated surface may be masked by standard dose heparinization.
The objective of this study was to elucidate how cryotherapy after anterior cruciate ligament reconstruction affects intraarticular temperature and clinical results. A prospective and randomized study was performed on 21 knees of 21 patients. The ligament reconstruction was performed by single-incision arthroscopy using autogenous hamstring tendon. On completion of the surgery, thermosensors were implanted in the suprapatellar pouch and the intracondylar notch, and the intraarticular temperature was monitored while the joint was cooled. Cooling was performed in one group at 5 degrees C (N = 7) and in another at 10 degrees C (N = 7), for 48 hours. A control group (N = 7) did not undergo cryotherapy. The cooled groups showed three temperature phases: a low-temperature phase immediately after the ligament reconstruction, followed by a temperature-rising phase and a thermostatic phase. The control group had no low-temperature phase and immediately entered a thermostatic phase. During the low-temperature phase in the treated groups, the temperature of the suprapatellar pouch and of the intercondylar notch were significantly lower than the body temperature. The pain score and the number of times an analgesic had to be administered were both significantly lower in the 10 degrees C group than in the control group. Blood loss was significantly less in the 5 degrees C group than in the control group.
In vivo intratumoral gene transfer of allogeneic class I major histocompatibility complex (MHC) genes augments the immune response against weak tumor antigens. In this study, mice inoculated with the allogeneic MHC molecule (H-2Kb), had transduced-murine neuroblastoma C1300S3 cells showed prolonged survival relative to non-transduced or neo transduced tumors (p < 0.005). Interestingly, direct in vivo gene transfer of H-2Kb plasmid DNA complexed with HVJ-liposomes into S3 tumors was highly efficient, resulting in transduction of 8% of the interstitial cells within the tumor but rarely within tumor cells. Regression of established tumors and prolonged survival occurred in 50% of mice injected with H-2Kb, in contrast to no tumor regression in mice receiving control plasmid (p < 0.005). This study concludes that interstitial cells could serve as an important target of intratumoral gene transfer, and further that HVJ-liposome complexes could be a vehicle for in vivo gene transfer.
Platelet adhesion on an oxygenator membrane is associated with thrombocytopenia or thrombus formation during extracorporeal circulation. The authors evaluated protein adsorption and platelet adhesion on three oxygenator hollow fiber membranes fabricated with polypropylene, silicone, and double layer polyolefin. Adsorbed proteins were analyzed by bicinchoninic acid protein assay, sodium dodecyl sulfate polyacrylamide gel electrophoresis, and Western blot. Platelet adhesion was assessed with enzyme immunoassays using monoclonal antibodies directed against CD42b and CD61. After 3 hr of incubation at 37 degrees C in whole blood, the amount of adsorbed protein was the least on silicone and increased from silicone < double polyolefin < polypropylene. The adsorbed protein pattern was similar; however, silicone showed less adsorption for all protein bands, and the gamma chain of fibrinogen was not detected. In contrast, double polyolefin showed the highest fibrinogen adsorption. The optical density at a wavelength of 450 nm for CD42b was 1.47 +/- 0.35 in polypropylene, 1.16 +/- 0.38 in silicone, and 1.85 +/- 0.19 in double polyolefin (p < 0.01 vs silicone) and for CD61 0.98 +/- 0.39 in polypropylene, 0.91 +/- 0.22 in silicone, and 1.69 +/- 0.25 in double polyolefin (p < 0.01 vs silicone and polypropylene). These data suggest that silicone is advantageous for long term extracorporeal respiratory support in terms of less platelet adhesion and no plasma leakage through the pores.