Toward absolute reflectance oximetry: I. Theoretical consideration for noninvasive tissue reflectance oximetry.

The photon diffusion theory can yield quantitative estimation of tissue hemoglobin saturation, provided that the medium is homogeneous and that one calibration data is available. The error in detection of tissue OS of the gut mucosa ranged from 5 to 10% in oxygen saturation. In application to skin, the two-layer tissue model suggests that by properly designing the optical sensor and by appropriately selecting the illumination wavelengths, it is possible to capture mainly the light returning from the specific depth in tissue. Since the skin layer thickness is roughly in the order of 1 mm, the source and detector separation distance of approximately 3 mm or larger would ensure that the measured reflectance is truly returning from the deeper layer. When such reflectances are normalized to the blood-free reflectance obtained by squeezing the blood out of the tissue, the normalized reflectance truly represents the deeper layer characteristics. In application to head, since the skin and skull thickness is considerable large, separation distance of 40 mm or greater is required to ensure the reflectance is actually returning from the brain. Closely spaced optical sensor would measure the scattering and absorption characteristics of the skin and skull of the head. As for directional changes in optical propagation due to tissue inhomogeneities, multiple light sources at the equi-distance around the detector can be placed to average out the effect. The resultant reflectance can be analyzed based on the similar mathematical treatment as presented in this study. However, since the absolute reflectance level calculated by the theory and the actual reflectance for a given transducer geometry have some deviation, again one point calibration is required to close the gap between them. This can be accomplished through arterialization of the tissue and ventilating with pure oxygen to yield reflectance from tissue containing 100% saturated blood. As for hemoglobin content, isosbestic reflectance, for example at 805 nm, can be utilized to estimate tissue hemoglobin content. Once one point calibration is accomplished, reflectance changes thereafter due to changes in HbT and OST can be fairly accurately predicted by the photon diffusion theory in combination with linear analysis. Concerning separation of arterial and venous blood in tissue, the diastolic and systolic phases of the optical plethysmographic signal can be assumed to relate to venous or DC level, and to arterial or AC component. Since the four components, arterial and venous OS and Hb, are unknowns in the system, four equations or four wavelength measurements are required to sort out each effect.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Prerequisites to salvage profound biventricular failure patients with ventricular assist devices.

We conducted chronic experiments to determine how to treat profound biventricular failure systematically with ventricular assist devices (VADs) and to analyze the factors that affect prognoses for this condition. Anoxic arrest was induced in ten goats by aortic cross-clamping under normothermic conditions (38.5 degrees C) for 30 (n = 3), 45 (n = 1), and 60 (n = 6) minutes. A left ventricular assist device (LVAD) was implanted in eight animals, and a biventricular assist device (BVAD) was used in two. Three goats--two of which had undergone anoxic arrest for 30 minutes and one for 60 minutes--whose right atrial pressure (RAP) was approximately 18 mm Hg during the acute stage, recovered in two to three weeks, and the pumps were successfully removed. Pathological findings in these animals showed scattered areas of surviving myocardium, with connective tissue replacing the degenerated myocardium. The remaining five LVAD goats required higher RAPs to maintain circulation and died from various causes. Maintaining circulation without volume loading, even in the presence of arrhythmias, was easier with the BVAD. One BVAD animal that underwent 45 minutes of anoxic arrest recovered from right ventricular failure, and the right pump was removed. The second goat (anoxic arrest, 60 min) on the BVAD failed to recover. Autopsy of the myocardium revealed a thin ventricular wall. Our studies show that the use of VADs allows time for a failing heart to recover, but the potential for healing is affected by the severity of myocardial damage prior to VAD application.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Continuous measurement of oxygen delivery and oxygen consumption in awake live animals.

For continuous measurement of both SO2 and [Hb] of whole blood, a hybrid type optical sensor was developed, tested in vitro and applied to the continuous measurement of arterial and mixed venous SO2 and [Hb] of awake live animals whose circulation was entirely supported by a pair of artificial hearts. The purpose of using artificial hearts was to control the cardiac function precisely and to obtain independent responses of the peripheral circulatory system. Both sensors in the arterial and venous circuits functioned satisfactorily for a duration of 40 days; no blood clots were observed around the sensor and the mixed venous SO2 varied sensitively in response to changes in the respiratory status, pump output, [Hb], and oxygen consumption, thus showing that it could be used as an indicator to evaluate the adequacy of oxygen delivery to peripheral tissues.

Animals↗

Verification of Fourier phase and amplitude values from simulated heart motion using a hydrodynamic cardiac model.

Using pusher-plate-type artificial hearts, changes in the degree of synchrony and stroke volume were compared to phase and amplitude calculations from the first Fourier component of individual-pixel time-activity curves generated from gated radionuclide images (RNA) of these hearts. In addition, the ability of Fourier analysis to quantify paradoxical volume shifts was tested using a ventricular aneurysm model by which the Fourier amplitude was correlated to known increments of paradoxical volume. Predetermined phase-angle differences (incremental increases in asynchrony) and the mean phase-angle difference calculated from RNAs showed an agreement of -7 degrees +/- 4.4 degrees (mean +/- SD). A strong correlation was noted between stroke volume and Fourier amplitude (r = 0.98; P less than 0.0001) as well as between the paradoxical volume accepted by the 'aneurysm' and the Fourier amplitude (r = 0.97; P less than 0.0001). The degree of asynchrony and changes in stroke volume were accurately reflected by the Fourier phase and amplitude values, respectively. In the specific case of ventricular aneurysms, the data demonstrate that using this method, the paradoxically moving areas may be localized, and the expansile volume within these regions can be quantified.

Fourier Analysis↗

Prediction of improvement in left ventricular function after ventricular aneurysmectomy using Fourier phase and amplitude analysis of radionuclide cardiac blood pool scans.

Postoperative improvement in left ventricular (LV) function is a common objective of LV aneurysmectomy, but is difficult to predict. The first Fourier component of time-activity curves of pre- and postoperative gated radionuclide angiographic studies was evaluated for this purpose in 20 patients who had undergone aneurysmectomy. LV aneurysms had portions that characteristically exhibited marked phase delay with varying degrees of amplitude. Total aneurysmal amplitude was obtained preoperatively by summing the amplitude component of all pixels that exhibited phase delay, suggesting paradoxical motion. LV ejection fraction (EF) before and after aneurysmectomy and the absolute postoperative increase in LVEF were calculated. Nine of 20 patients had an absolute increase of EF less than 10% despite resection of large aneurysms. A strong correlation was found between the absolute increase in EF after aneurysmectomy and the total amplitude within paradoxically moving areas (r = 0.93, p less than 0.0001). Thus, preoperative measurement of the total paradoxical amplitude predicts absolute change in EF and may be important in selecting patients for aneurysmectomy. The data also suggest that the total aneurysmal amplitude reflects the stroke volume ejected into an aneurysm in systole and that paradoxical expansion of an aneurysm contributes to LV dysfunction in some of these patients.

Adult↗

Experimental results for chronic left ventricular assist and total artificial heart development.

After more than 20 years of research on the artificial heart, it is now accepted that the pneumatically actuated total artificial heart can maintain near-normal physiology in experimental animals for several months. Such systems are clinically acceptable for short-term application (a few months) in patients waiting for a suitable heart transplant. However, realistically, a cardiac prosthesis that has the capability of being totally implantable for over 2 years must be available. Based on this premise, our group initiated the development of a mechanically actuated total artificial heart, capable of coupling with either a thermal or electrical actuation system. Since 1977, under the National Institutes of Health chronic left ventricular assist program, we have used two different pusher-plate pumps and electrical systems. Taking advantage of technology generated in these programs, we began developing a prosthesis to replace the total cardiac function. This paper is a summary of both the chronic left ventricular assist and total artificial heart development progress in this laboratory.

Animals↗

Pusher-plate type TAH system operated in the left and right free-running variable rate mode.

A TAH system utilizing two pusher-plate type pumps was developed and tested in two calves for 45 and 108 days with excellent results. A Hall effect sensor was utilized to operate each pump with a full stroke at variable rates (VR); each pump was then allowed to run independently at different rates depending on its own preload and afterload. With this system, the animals' atrial pressures were kept to near-normal levels (less than 10 mmHg). However, significant differences in the left and right pump flows were observed (left higher than right) and they ranged from 5 to 30% of the left flow with a mean of 15%. These flow differences may be due to the bronchial circulation and related shunts. Right pump flows averaged 70 to 95 ml/min-kg and circulating blood volume ranged from 67 to 95 ml/kg. When various control modes including fixed rate and master-slave type simultaneously or alternatively ejecting VR modes were applied in the same animals and both pump flows were forced to be equal, unphysiological atrial pressures resulted. This result indicates that perhaps left and right flow differences are necessary physiological conditions to regulate the atrial pressures within normal ranges. Metabolic data also indicated that under simultaneously and alternately ejecting modes, A-V O2 content differences were increased due to decreased right pump flow as compared with those of the free-running VR mode. The left and right free-running VR mode of operation imposed minimal constraints on the animals' cardiovascular system and therefore yielded excellent hemodynamic and metabolic results.

Animals↗