A seal-less centrifugal pump (Baylor Gyro Pump) for application to long-term circulatory support.

We are developing a new centrifugal pump, the Baylor Gyro Centrifugal Pump (Gyro Pump), which can function for more than 2 weeks. The concept of the Gyro Pump is that a one-piece rotor-impeller with embedded permanent magnets, driven directly by a brushless direct current motor stator placed outside, rotates like a "gyroscope," and the rotor-impeller is supported by one pivot bearing at the bottom in accordance with the gyroscopic principle. This concept enables us to eliminate a driving shaft and a seal between the driving shaft and the blood chamber, which results in extending the life of the centrifugal pump. The blood passes through the space between the motor stator and the rotor to the impeller portion. In this preliminary phase, two pivot bearings were applied to support the rotor-impeller at the top and the bottom inside the blood chamber. Both pivot bearings showed less blood trauma and less thrombogenicity in in vitro and in vivo studies. The Gyro Pump is a promising second-generation centrifugal pump for long-term circulatory support in the near future.

Animals↗

Open-loop analysis of circulatory system in awake live animals: relations between mixed venous saturation (SvO2) and hemodynamic parameters.

In order to derive quantitative relations between the mixed venous hemoglobin saturation (SvO2) and hemodynamic and metabolic parameters in awake live animals, biventricular bypass experiments were conducted in goats using a pair of pneumatic artificial hearts. The artificial hearts were used to bypass continuously the fibrillating ventricles, to control precisely the pump output, and to derive open-loop responses of the peripheral circulatory system. The specially developed reflection-type optical sensors were mounted on each artificial heart to measure continuously arterial and mixed venous SO2 and hemoglobin content ([Hb]), which in combination with pump output data oxygen consumption of the animal was derived on-line for a maximum duration of 40 days. The SvO2 sensitively reflected the changes in respiratory status. [Hb], pump output, and oxygen consumption. The SvO2 was linearly related to the oxygen consumption but showed nonlinear relation to the pump output. The exercise study revealed that the SvO2 level may be used to detect the anaerobic threshold. The SvO2 is a useful parameter to evaluate circulatory status of the patients.

Animals↗

Left and right pump output control in one-piece electromechanical total artificial heart.

Left master alternate (LMA) ejection control based on the left pump fill method was implemented for a one-piece electromechanical total artificial heart (TAH). The TAH consists of left and right pusher-plate-type blood pumps sandwiching a compact electromechanical actuator comprising a direct current (DC) brushless motor and a planetary roller screw. The motor rotation is controlled on the basis of the roller-screw position as detected by a Hall effect sensor and a commutation pulse counting method. Since the pusher-plate shaft and roller screw are decoupled during filling, both pumps fill passively with the right and left atrial pressure. To obtain response to the right atrial pressure change in the LMA mode, the left fill trigger level as detected by a Hall effect position sensor is adjusted to operate the pump at a higher rate and to drive the right pump at 85-90% of the full stroke level. The in vitro evaluation demonstrated that this method can respond to right atrial pressure changes provided that the right pump is operated at less than the full stroke level. When the preload is high and the right pump goes into full stroke operation, the left eject level can be decreased to run the pump at a higher rate and to transfer more blood from the right to the left. In the in vivo evaluation, which lasted 1 week in a 95 kg calf, the left and right atrial pressures were kept within physiological ranges.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Baylor Gyro Pump: a completely seal-less centrifugal pump aiming for long-term circulatory support.

A seal-less centrifugal pump aiming for long-term circulatory support has been developed. In this model, shaft seals that cause thrombus formation and blood leakage were eliminated. A brushless direct current motor was incorporated as a driving unit, and pivot bearings were used to support the impeller. With reference to its motor-driven system, this pump was named the M-Gyro Pump. The first model (M1) yielded an index of hemolysis of 0.005 g/100 L using bovine blood and demonstrated satisfactory performance as a right heart assist for 2 days (4 L/min, 60 mm Hg, 1,800 rpm). The second model (M2) has been developed for left heart assist by employing a stronger motor. The pump capacity was improved to 6 L/min against 240 mm Hg at 1,800 rpm, but significant heat generation was observed. By optimization of motor efficiency, the M2 model can be improved to meet the requirements of a pump for left heart assist.

Animals↗

In vitro performance of the Baylor/NASA axial flow pump.

A cooperative effort between Baylor College of Medicine and NASA/Johnson Space Center is under way to develop an implantable axial flow left ventricular assist device (LVAD). The pump is intended as an assist device for either pulmonary or systemic circulatory support for more than 3 months' duration. Currently, in vitro studies are under way to reduce the hemolysis generated by the axial flow pump. A system utilizing a testing matrix has been developed to analyze the effects of different pump parameters on hemolysis. The following parameters are being investigated: impeller blade tip geometry, impeller/flow tube clearance, impeller/stator clearance, number of impeller blades, number of stator blades, and length of the impeller. To date, an index of hemolysis of 0.038 g/100 L has been achieved. The test matrix is not complete, and further improvements are expected.

Animals↗

Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support.

The Baylor-Nikkiso centrifugal pump is a magnetically coupled system with a V-ring seal separating the pump and the actuator chamber. To prevent thrombus formation behind the impeller and to extend the life of the pump to 2 weeks of continuous operation, we incorporated a purging chamber behind the V-ring seal. An external pump connected to this purging chamber infused fluid at a constant rate to wash the shaft-seal area. To evaluate the effectiveness of the purging system, we have carried out biventricular bypass experiments using calves. The purging system was successful in reducing the level of thrombus formation after 2 weeks of operation. The results of these studies confirmed that the Baylor-Nikkiso centrifugal pump with this purging system is suitable for at least 2 weeks of continuous operation as a circulatory support system.

Animals↗

A fluid dynamic analysis of a rotary blood pump for design improvement.

The proper design of a left ventricular assist device (LVAD) requires an understanding of the pump's fluid dynamic and biocompatible properties. A hydraulically efficient system minimizes the power required for pumping. Biocompatibility refers to the ability to pump blood with minimal hemolysis and thrombus formation. Typically, shear stresses below a threshold level will not damage blood significantly. A fluid dynamic analysis of a prototype centrifugal pump designed for use as an LVAD was performed to establish flow characteristics. A flow visualization technique using Amberlite particles suspended in a glycerin/water blood analogue was used. The system was illuminated with a 1 mm planar beam strobed helium-neon laser, and the results were recorded photographically. An analysis of photographs revealed laminar and turbulent flows with vortices within an illuminated plane in both the inlet and outlet port areas. From these data, velocity and shear stress profiles were generated that showed possible areas of improvement. It was concluded that the outlet port design could be improved by changing its angle and the continuity of its expansion. The inlet port could also be improved by smoothing the transition area between the inlet tube and the pump body to allow for gradual acceleration of the entering fluid.

Blood Flow Velocity↗

Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.

The objective of this study was to evaluate a new reflectance pulse oximeter sensor. The prototype sensor consists of 8 light-emitting diode (LED) chips (4 at 665 nm and 4 at 820 nm) and a photodiode chip mounted on a single substrate. The 4 LED chips for each wavelength are spaced at 90-degree intervals around the substrate and at an equal radial distance from the photodiode chip. An optical barrier between the photodiode and LED chips prevents a direct coupling effect between them. Near-infrared LEDs (940 nm) in the sensor warm the tissue. The microthermocouple mounted on the sensor surface measures the temperature of the skin-sensor interface and maintains it at a present level by servoregulating the current in the 940-nm LEDs. An animal study and a clinical study were performed. In the animal study, 5 mongrel dogs (weight, 10-20 kg) were anesthetized, mechanically ventilated, and cannulated. In each animal, arterial oxygen saturation (SaO2) was measured continuously by a standard transmission oximeter probe placed on the dog's earlobe and a reflectance oximeter sensor placed on the dog's tongue. In the first phase of the experiment, signals from the reflectance sensor were recorded while the dog was immersed in ice water until its body temperature decreased to 30 degrees C. In the second phase, the animal's body temperature was normal, and the oxygen content of the ventilator was varied to alter the SaO2. In the clinical study, 18 critically ill patients were monitored perioperatively with the prototype reflectance sensor. The first phase of the study investigated the relationship between local skin temperature and the accuracy of oximeter readings with the reflectance sensor. Each measurement was taken at a high saturation level as a function of local skin temperature. The second phase of the study compared measurements of oxygen saturation by a reflectance oximeter (SpO2[r]) with those made by a co-oximeter (SaO2[IL]) and a standard transmission oximeter (SpO2[t]). Linear regression analysis was used to determine the degree of correlation between (1) the pulse amplitude and skin temperature; (2) SpO2(r) and SaO2(IL); and (3) SpO2(t) and SaO2(IL). Student's t test was used to determine the significance of each correlation. The mean and standard deviation of the differences were also computed. In the animal study, pulse amplitude levels increased concomitantly with skin temperature (at 665 nm, r = 0.9424; at 820 nm, r = 0.9834; p < 0.001) and SpO2(r) correlated well with SaO2(IL) (r = 0.982; SEE = 2.54%; p < 0.001).(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Development of a totally implantable electromechanical total artificial heart: Baylor TAH.

A totally implantable, one-piece, electrome-chanical total artificial heart (TAH) intended for permanent human use has been developed. It consists of left and right pusher-plate pumps (63 cc design stroke volume) sandwiching a thin center piece with a compact electromechanical actuator. The pusher-plates are shaped conically to accommodate an actuator in the space between them. The actuator consists of an efficient and durable planetary roller screw and direct current brushless motor. The left master alternate pumping mode was implemented utilizing the left pump pusher-plate position signal. The blood-contacting surface was coated with a dry gelatin to yield long-term clot-free performance. Trileaflet tissue valves of 27 and 23 mm are used in the inflow and outflow ports. The diameter and thickness of the TAH are 97 and 82 mm. the overall volume is 510 cc, and the weight is 620 g. Anatomic fit was confirmed in 26 heart transplant recipients (body weight 78 kg and surface area 2 m2) without compressing adjacent organs. The pump performance study revealed that the TAH can yield outputs of 3-8 L/min against the 100 mm Hg afterload with 1-10 mm Hg filling pressure. The input power to the motor ranged from 7 to 12 W, with an efficiency of 18% to 14%. A one-week in vivo calf study demonstrated adequate performance of the TAH, particularly the regulation of atrial pressures. Good anatomic fit and good biocompatibility were also demonstrated.

Animals↗

Development of totally implantable electromechanical artificial heart systems: Baylor ventricular assist system.

An implantable electromechanical ventricular assist system (VAS) intended for permanent use has been developed. It consists of a conically shaped pumping chamber, a polyolefin (Hexsyn) rubber diaphragm attached to a conically shaped pusher-plate, and a compact roller-screw actuator. Design stroke volume is 63 ml. The device weighs 620 g, and has a total volume of 348 ml. The pump can provide 8 L/min flow against 120 mm Hg afterload with a preload of 10 mm Hg. The inner surfaces are biolized by dry gelatin coating, with inflow and outflow ports accommodating tissue valves. Three subacute in vivo validation studies have been conducted in calves up to two weeks. The entire system functioned satisfactorily in both the fill/empty and the fixed-rate modes. There was no thromboembolic complication without anticoagulation. The pump showed reasonable anatomical fit inside the left thorax. This VAS is compact, efficient, quiet, and easy to control.

Animals↗

A compact centrifugal pump for cardiopulmonary bypass.

A majority of the cardiopulmonary bypass (CPB) systems still utilize bulky roller pumps. A direct-drive small centrifugal pump intended for second-generation CPB pump has been developed. The pump has a 50 mm diameter impeller and provides a 6 L/min flow at 3,000 rpm against 300 mm Hg. A flexible drive shaft allows us to separate the pump head from the console resulting in easier manipulation. An in vitro study showed that the pump generated less hemolysis (index of hemolysis = 0.0011, comparable to the value for Bio-medicus BP-80). To improve blood flow around the shaft-seal region and to reduce thrombus formation around the shaft, six holes were drilled through the impeller. In biventricular bypass experiments using calves, our pump demonstrated excellent antithrombogenicity and durability for 48 h. And the compact and atraumatic centrifugal pump system showed excellent performance and easy manipulation under actual CPB conditions in animal.

Animals↗

Versatile one-piece total artificial heart for bridge to transplantation or permanent heart replacement.

A versatile, one-piece total artificial heart (TAH) system that can be driven by either an electromechanical acutator (EM-TAH) or a pneumatic source (P-TAH) has been developed. The common units for both TAHs are the conically shaped left and right pusher-plate-type pumps (63 ml SV) that sandwich a thin centerpiece (18 mm) having a respective actuator. The EM actuator, mounted in the middle of the centerpiece, consists of a direct-current brushless motor and a roller screw while the pneumatic actuator consists of a low-pressure air source. The outer diameter of the pumping unit is 97 mm with its central thickness being 82 mm; overall volume is 510 cc. The TAH is operated in the left master alternative ejection mode with the left pump fill signal. High-flex-life Hexsyn rubber is used as the diaphragm, and the blood-contacting surface is coated with dry gelatin. The TAH can provide 3-8 L/min flow with a preload of 1-10 mm Hg against 100 mm Hg afterload. Anatomical fit of the pumping unit has been demonstrated in the pericardial space of 26 heart transplant recipients with average body weight of 78 kg. To date, 2 P-TAH and 4 EM-TAH (1 week) implantations were performed in 80-100 kg calves demonstrating excellent anatomical fit, controllability, and biocompatibility. This versatile TAH is suitable for a bridge to transplantation or permanent heart replacement.

Animals↗

Potential clinical applications of the oxygen carrying solutions.

Two major areas of research of the oxygen carrying solutions are 1) utilization of hemoglobin and 2) perfluorochemicals. Even though they are not perfect red blood cell substitutes, the "oxygen carrying solutions" have many potential clinical applications because they will reach tissues more easily than normal human red cells and can deliver oxygen directly to tissues. In this paper, important examples of such usages are suggested. Additional clinical and non-clinical applications of the oxygen carrying solutions may be added in the near future.

Artificial Organs↗

Evaluation of a new reflectance pulse oximeter for clinical applications.

The design of a noninvasive reflectance pulse oximeter that uses the same principle of transmittance pulse oximeter and analyses the oxygen saturation of arterial blood was described. Four sets of red and infra-red LEDs were used as light sources. The respective reflectance photoelectric outputs were used to make an internal calibration curve of the instrument relative to the arterial oxygen saturation values measured with a Co-Oximeter (OSM-3) in five healthy nonsmoking subjects during steady-state hypoxaemia. The accuracy of the present instrument was studied in six patients with respiratory failure. From 22 samples, a good correlation coefficient (0.98) with a standard deviation of 1.42 was obtained in the range between 73 and 100 per cent between the arterial oxygen saturation measured with the present instrument and that with the Co-Oximeter. The result strongly suggests the usefulness of this oximeter in monitoring patients with hypoxaemia.

Adult↗

Continuous in-line monitoring of oxygen delivery to control artificial heart output.

In order to evaluate the pump output control based on the oxygen delivery to peripheral tissues, arterial and mixed venous hemoglobin content ([Hb]) and oxygen saturation (SO2) were continuously monitored in three biventricular bypass animals (3-, 6-, and 40-day experiments) with fibrillating ventricles. The specially developed oxygen sensors were mounted in the outflow ports of the artificial hearts to measure [Hb] and SO2. One animal was exercised on the treadmill at 2.0 mile/h for 15 min with pump flows fixed to deliver oxygen of (a) above 13 cc/min/kg, (b) 10, and (c) 9. In (a), the mixed venous saturation (SvO2) dropped to approximately 25% with no increase in the blood lactate level. In (b) and (c), the SvO2 decreased to approximately 10-15% with increase in blood lactate levels from 4 to 10-30 mg/dl. Also, the recovery of the SvO2 in these groups following the termination of the exercise was slower in comparison to (a). The lower limit of the SvO2 level that would create oxygen debt situation in the peripheral tissues was approximately 25-30% for the exercise of 2.0 mile/h. The SvO2 reflects changes in respiratory status, pump output, hemoglobin level, and metabolism, and is thus a useful indicator to diagnose quickly the circulatory status as well as possibly to control the artificial heart output.

Animals↗