Search PubMed⌕ Search

Biomedical subjects

S Saini

Publications and source records attributed to S Saini.

At least 37 records · Page 2Linked to original sources

Quantification of polynuclear aromatic hydrocarbons in transformer oils by enzyme immunoassay.

Many polynuclear aromatic hydrocarbons (PAHs) are either known or suspected carcinogens and are a common constituent of mineral oils. Due to the large number of possible PAH structures, standard quantification methods fail since they either lack specificity or are too complex, requiring individual fractionation, identification, and quantification. A rapid, low-cost, novel analytical screening method, incorporating a silica-based solid-phase extraction (SPE) method linked to co-solvent dilution and quantification of total and carcinogenic PAH levels by immunoassay, is reported here. The method yielded high extraction efficiencies and minimal matrix effects. This novel approach yielded total and carcinogenic PAH levels x 5.7 and x 126, respectively, lower than that recorded by the industry-recognised BS2000 Pt. 346 (IP346) method which estimates the polyaromatic carbon (PAC) content of oils by gravimetry. The method is expected to be of benefit where an indication of PAH levels in oils is important for purchasing, management or disposal purposes and also for risk assessment and for appropriate labelling of oils in line with current legislation.

Carcinogenicity Tests↗

Technical cost of CT examinations.

PURPOSE: To measure the technical cost of different categories of computed tomographic (CT) examinations. MATERIALS AND METHODS: For fiscal year 1997, the technical costs of performing CT examinations in a tertiary care academic medical center were measured. Costs were divided into labor and nonlabor categories. Indirect departmental costs were fully allocated according to activity-based methods. Hospital overhead costs were set at 85% of the departmental budget. Physician costs, including those related to image interpretation were not included. The technical cost of CT was determined on a per technical relative value unit (RVU) basis and on a per examination basis. For the latter, the technical cost of nonenhanced CT, contrast material-enhanced diagnostic CT, and interventional CT procedures were determined. RESULTS: In fiscal year 1997, 45,599 examinations (22,158 [48.6%] abdominal and/or pelvic, 12,115 [26.6%] head and neck, 6,572 [14.4%] thoracic, 1,593 [3.5%] interventional, and 3,161 [6.9%] other) were performed with five CT scanners for a technical RVU output of 254,461. Of 45,599 examinations, 31,007 (68%) were performed with intravenously administered contrast medium. Overall labor costs were $1,744,653, and nonlabor costs were $2,912,282. The cost of a hypothetical CT examination with a mean technical RVU of 5.58 was $189. The overall cost per examination was $150 for nonenhanced CT, $237 for contrast-enhanced CT, and $462 for interventional CT. CONCLUSION: Although CT is based on sophisticated technology, the mean technical cost of a diagnostic CT examination is less than $200.

Costs and Cost Analysis↗

Quantitative and qualitative evaluation of volume of low osmolality contrast medium needed for routine helical abdominal CT.

OBJECTIVE: The purpose of our study was to determine the minimum optimal dose of IV contrast medium for helical CT that can preserve image quality while reducing cost. SUBJECTS AND METHODS: Four hundred sixty-three patients from six centers were enrolled in a prospective trial in which patients were randomized into one of four weight-based dose categories of iopromide, 300 mg I/mL: 1.25, 1.50, 1.75, and 2.0 mL/kg. Six of 463 patients were excluded from analysis. A radiologist at each center who was unaware of the volume of contrast medium administered determined whether the scans were acceptable. The responses were analyzed by dose, in aggregate, and by weight. Enhancement values (in Hounsfield units) in regions of interest in the liver, pancreas, aorta, and kidneys were obtained at a single time during the scan. The participating radiologist was unaware of these values. Finally, three additional nonparticipating site observers assessed the images for acceptability, diagnostic quality, and overall level of confidence. A cost model comparing incurred charges in using 150 or 100 mL, or 1.5 mL/kg, of low osmolality contrast medium was developed from experience in an additional 303 patients. RESULTS: We found no clinically significant difference in acceptability of scans at doses greater than 1.5 mL/kg. However, significant variability occurred among the centers. The use of 1.5 mL/kg led to a savings of $9927.16 for 303 patients when compared with the use of 150 mL at list price. The cost is the same for 1.5 mL/kg or use of 100 mL of contrast medium. CONCLUSION: A weight-based dose at 1.5 mL/kg of low osmolality contrast medium can provide acceptable scans in most patients, with a significant cost savings.

Body Weight↗

Effect of multislice CT technology on scanner productivity.

OBJECTIVE: In this study we analyzed the impact of multislice CT technology on scanner productivity in a tertiary care medical center. MATERIALS AND METHODS: We compared the productivity of two diagnostic CT scanners during the periods January 1 to August 31, 1999 (when both scanners had single-slice CT capability) and January 1 to August 31, 2000 (when one of these scanners was replaced with a multislice CT scanner). The scanners were used primarily for outpatients during the day shift and for inpatients during the evening shift; the demand for CT services was stable. For this analysis, we queried the hospital's radiology information system and identified the number of CT examinations performed during the two analysis periods. We also determined the examination mix, including proportion of enhanced and unenhanced examinations and the anatomic region examined, to ensure comparable patient populations. Statistical analysis was performed. RESULTS: The number of CT studies performed on the two scanners increased by 1772 (13.1%) from 13,548 (before multislice CT) to 15,320 (when multislice CT was available). The number of examinations enhanced with contrast media increased from 52% to 65%. Between 9:00 A.M. and 5:00 P.M., the number of CT examinations was similar on the single-slice scanners in the two periods (p > 0.05). However, in the period when multislice CT was available, the number of studies performed on the multislice scanner (5919) was 51.9% higher than those performed using the single-slice scanner (3896) (p < 0.0006). CONCLUSION: Using a multislice CT scanner leads to an increase in CT productivity, even though multislice studies are performed using more complicated protocols than are used on a single-slice CT scanner.

Efficiency↗

Sniffing out disease using the artificial nose.

Is there information in the odours that we emit and that circulate around us? More importantly, can doctors gain knowledge of disease by smelling their patients? Machines that emulate the mammalian nose have picked up the scent of several diseases and may drastically change diagnostic procedure.

Diagnostic Techniques and Procedures↗

A study of bacterial pathogens in acute pelvic inflammatory disease.

The study was carried out on two groups--the study group consisting of 50 women with acute pelvic inflammatory disease and the control group consisting of 20 women admitted for tubal ligation. Pouch of Douglas aspirates were collected under all aseptic precautions with 18 gauge medicut needle. The samples were transferred to thioglycollate broth. A direct Gram staining was done followed by plating on media for aerobic and anaerobic incubation. All cultures were sterile in the control group. There were both monomicrobial (56.7%) and polymicrobial (43.2%) isolates in the study group. The predominant aerobic isolates were coagulase negative Staphylococci, E. coli and Staphylococcus aureus. Amongst anaerobic isolates gram negative bacilli were the most common at 46.6% followed by gram positive cocci at 40%.

Adolescent↗

Identification of a putative LPS-associated cation exporter from Rhizobium leguminosarum bv. viciae.

A gene, cpaA, with similarity to calcium proton antiporters has been identified adjacent to lpcAB in Rhizobium leguminosarum. LpcA is a galactosyl transferase while LpcB is a 2-keto-3-deoxyoctonate transferase, both of which are required to form the lipopolysaccharide (LPS) core in R. leguminosarum. Mutations in lpcAB result in a rough LPS phenotype with a requirement for elevated calcium concentrations to allow growth, suggesting that truncation of the LPS core exposes a highly negatively charged molecule. This is consistent with the LPS core being one of the main sites for binding calcium in the Gram-negative outer membrane. Strain RU1109 (cpaA::Tn5-lacZ) has a normal LPS layer, as measured by silver staining and Western blotting. This indicates that cpaA mutants are not grossly affected in their LPS layer. LacZ fusion analysis indicates that cpaA is constitutively expressed and is not directly regulated by the calcium concentration. Over-expression of cpaA increased the concentration of calcium required for growth, consistent with CpaA mediating calcium export from the cytosol. The location of lpcA, lpcB and cpaA as well as the phenotype of lpcB mutants suggests that CpaA might provide a specific export pathway for calcium to the LPS core.

Amino Acid Sequence↗

High-sensitivity chromatographic detector incorporating three-dimensional charge coupled device fluorimetry.

This article describes a detector for liquid chromatography that provides three-dimensional, excitation-emission-intensity data of fluorescent compounds. The instrument achieves multi-wavelength excitation by employing a polychromator that disperses radiation along the vertical portion of a quartz capillary flow cell. The ensuing sample fluorescence is collected in the horizontal plane and dispersed using an emission polychromator to form a focused two-dimensional excitation-emission image at a charge coupled device (CCD) pixel array. Each vertical pixel equates to a narrowly defined excitation wavelength band, whilst horizontal pixels equate to corresponding emission wavelengths, with the intensity of light encroaching onto the CCD pixel elements providing the third-dimensional variable in the measurement. It is shown that the extreme sensitivity of CCD detection coupled to the dual polychromator arrangement makes possible the collection of fluorescence excitation-emission-intensity data of polycyclic aromatic hydrocarbons in a flow stream in less than 0.05 s with nanogram per millilitre limits of detection.

Anthracenes↗

Safety and efficacy of mangafodipir trisodium (MnDPDP) injection for hepatic MRI in adults: results of the U.S. multicenter phase III clinical trials (safety).

The short-term safety of mangafodipir trisodium (MnDPDP) injection was studied in 546 adults with known or suspected focal liver lesions. An initial contrast-enhanced computed tomography examination was followed by unenhanced magnetic resonance imaging (MRI), injection of MnDPDP (5 micromol/kg), and enhanced MRI. Adverse events were reported for 23% of the patients; most were mild to moderate in intensity, did not require treatment, and were not drug related. The most commonly reported adverse events were nausea (7%) and headache (4%). The incidence of serious adverse events was low (nine events in six patients) and not drug related. Injection-associated discomfort was reported for 69% of the patients, and the most commonly reported discomforts included heat (49%) and flushing (33%). Changes in laboratory values and vital signs were generally transient, were not clinically significant, and did not require treatment. There were no clinically significant short-term risks from exposure to MnDPDP.

Abdominal Pain↗

Efficacy and safety of mangafodipir trisodium (MnDPDP) injection for hepatic MRI in adults: results of the U.S. Multicenter phase III clinical trials. Efficacy of early imaging.

The efficacy of contrast-enhanced magnetic resonance imaging (MRI) for detecting and characterizing, or excluding, hepatic masses was assessed in 404 patients, following the intravenous administration of mangafodipir trisodium (MnDPDP) injection, a hepatic MRI contrast agent. An initial contrast-enhanced computed tomography (CT) examination was followed by unenhanced MRI, injection of MnDPDP (5 micromol/kg IV), and enhanced MRI at 15 minutes post injection. Agreement of the radiologic diagnoses with the patients' final diagnoses was higher for enhanced MRI and for the combined unenhanced and enhanced MRI evaluations than for unenhanced MRI alone or enhanced CT using the clinical diagnosis as the gold standard. Mangafodipir-enhanced MRI uniquely provided additional diagnostic information in 48% of the patients, and patient management was consequently altered in 6% of the patients. MnDPDP-enhanced MRI was comparable or superior to unenhanced MRI and enhanced CT for the detection, classification, and diagnosis of focal liver lesions in patients with known or suspected focal liver disease.

Adult↗

A novel sensor for monitoring leakage of petroleum and other liquid hydrocarbons into soil environments.

This paper describes the use of a potentially implantable infrared reflectometer for the qualitative detection of petroleum and a number of other hydrocarbon solvents. A rugged, low-power, re-useable sensor was evaluated in the laboratory for its ability to detect petrol in soil. A hydrophobic fluoropolymer was used as the sensing surface due to its high selectivity for petroleum hydrocarbons. The photocurrent reflected by this surface from a near IR source was measured to test for petroleum saturation within the membrane, which in turn was an indicator of petroleum in the surrounding soil. The simplicity in the sensor design enabled a stable, low cost detection method for petroleum and other hydrocarbons, ideal for use in sub-surface applications.

Environmental Monitoring↗

A ten channel fibre-optic device for distributed sensing of underground hydrocarbon leakage.

With millions of fuel storage tanks and oil pipelines installed around the world, there is inevitably frequent leakage of potentially hazardous hydrocarbons. As many of these installations are below ground, it can often be many years before the extent of the leak is discovered. We have previously reported the development of a sensor for the detection of such subterranean leaks, using infrared reflectometry to interrogate a hydrocarbon sensitive membrane. However, a single sensor cannot provide any information about the flow rate or direction of the leak. This paper describes the extension of the technology to a multi-channel distributed sensing system, using optical fibres capable of distributing the sensors over large subterranean areas. Results are reported from the evaluation of the device, which consisted of monitoring the movement of different hydrocarbons (gasoline, diesel and insulating oil) through a vertical sand-filled vessel.

Environmental Monitoring↗

Multicentre dose-ranging study on the efficacy of USPIO ferumoxtran-10 for liver MR imaging.

AIM: A dose ranging multicentre phase-II clinical trial was conducted to evaluate the efficacy of ultrasmall superparamagnetic iron oxide (USPIO) ferumoxtran-10 for magnetic resonance (MR) imaging of focal hepatic lesions. MATERIAL AND METHODS: Ninety-nine patients with focal liver lesions received USPIO at a dose of 0.8 (n = 35), 1.1 (n = 32), or 1.7 (n = 32) mg Fe/kg. Liver MR imaging was performed before and after USPIO with T1-weighted and T2-weighted pulse sequences. Images were analysed by two independent readers for additional information (lesion detection, exclusion, characterization and patient management). Signal intensity (SI) based quantitative measurements were also taken. RESULTS: Post-contrast medium MR imaging showed additional information in 71/97 patients (73%) for reader one and 83/96 patients (86%) for reader two. The results with all three doses were statistically significant (P < 0.05). Signal intensity analysis revealed that all three doses increased liver SI on T1-weighted images and decreased liver SI on T2-weighted images. On T2-weighted images metastases increased in contrast relative to normal hepatic parenchyma whereas haemangiomas decreased in contrast. On T2-weighted images there was statistically improved efficacy at the intermediate dose, which did not improve at the highest dose. CONCLUSION: Ultrasmall superparamagnetic iron oxide was an effective contrast agent for liver MR imaging at all doses and a dose of 1.1 mg Fe/kg was recommended for future clinical trials.

Adult↗

Technical cost of radiologic examinations: analysis across imaging modalities.

PURPOSE: To determine the individual technical costs of general diagnostic radiographic, ultrasonographic (US), computed tomographic (CT), magnetic resonance (MR) imaging, and scintigraphic examinations and interventional radiology. MATERIALS AND METHODS: The Radiology Cost and Productivity Benchmarking Study method of the University HealthSystem Consortium, a cooperative group of academic medical centers, was modified and extended to the six imaging modalities in a tertiary care academic setting. Hospital billing and cost records were analyzed for fiscal year 1996. Costs were divided into labor and nonlabor categories and were allocated to individual imaging modalities on the basis of resources consumed. Physician cost and hospital overhead were not included. Unit costs were analyzed per technical relative value unit (RVU) and per examination. RESULTS: The costs per technical RVU for diagnostic radiography, US, CT, MR imaging, scintigraphy, and interventional radiology were $65. 06, $28.74, $20.95, $17.69, $42.19, and $89.03, respectively. The technical costs per examination for diagnostic radiography, US, CT, MR imaging, scintigraphy, and interventional radiology were $41.92, $50.28, $112.32, $266.96, $196.88, and $692.60, respectively. CONCLUSION: The method of unit cost analysis for individual imaging modalities was successfully tested in a tertiary care setting. The method should be adopted to allow cost comparison across many institutions, which will permit the promotion of best practices.

Costs and Cost Analysis↗