Search PubMed⌕ Search

Biomedical subjects

S Ringoir

Publications and source records attributed to S Ringoir.

At least 163 records · Page 9Linked to original sources

LDH isozymes of human T and B lymphocytes.

Peripheral lymphocytes were obtained from five normal healthy adults. T and B lymphocytes were separated by rosette formation. LDH (L-lactate: NAD-+ oxidoreductase, EC 1.1.1.27) isozymes were studied on both populations after agar gel electrophoresis. The mean B lymphocyte pattern was: LDH-1, 7.2%; LDH-2, 25.0%; LDH-3, 39.2%; LDH-4, 21.9%; LDH-5, 6.6%. The mean T lymphocyte pattern was: LDH-1, 25.8%; LDH-2, 35.1%; LDH-3, 28.3%; LDH-4, 9.4%, LDH-5, 1.3%. This makes the T lymphocytes look more aerobic than the B lymphocytes. Daudicells had the following pattern: LDH-1, 8.4%; LDH-2, 19.1%; LDH-3, 26.6%, LDH-4, 24.9%; LDH-5, 20.9%.

Adult↗

Impairment of phagocytic activity of macrophages as studied by the skin window test in patients on regular hemodialysis treatment.

In 7 patients with less than 4 months of regular hemodialysis treatment (RDT), in 28 patients with more than 4 months RDT and in 9 normal subjects, the skin window technic of Rebuck and Crowley was used to study the cellular response and the phagocytic activity of macrophages. Phagocytosis of carbon particles is decreased in the patients with less than 4 months dialysis, whereas it is not significantly different from the normals in those being dialyzed for longer periods.

Humans↗

Short dialysis with a polyacrylonitrilmembrane (RP 6) without the use of a closed recirculating dialyzate delivery system.

Because of excessive eltrafiltration (UF), the RP 6 dialyzer requires a closed recirculating dialyzate delivery system. The purpose of this study is to present the characteristics of the RP 6 dialyzer on a single needle system which programs the UF rate of this dialyzer. The single needle system consists of one blood pu-mp and two roller pump heads, switched on and off at preselected maximum and minimum out let pressures (OP). It is possible to decrease the UF rate by lowering the OP in the bubble trap chamber. By varying OP from 0 to 100 mm Hg, we obtained an UF rate in vitro of 6.5 ml per minute. The clearance values, in ml/min, obtained at OP 0 to -100 NN Hg, QB 300 and QD 500 are (in ml/min): urea: 160.0, creatinine: 145.0, sucrose-C14: 105.4, sodiumiothalamate-i125: 79.9, cyanocobalamin-co58: 73.7 and inulin-3H: 40.7. The priming volume (corn-oil) at OP 0 to -100 MM Hg, QB 250, QD 500 varies between 140 ml (at the minimum OP) and 150 ml (at the maximum OP). We performed 370 dialyses. The dialysis runs were well tolerated: moderate hypotension occurred in 4% and cramps in 1.6% of the dialyses. In most cases no fluid perfusion was necessary. The residual blood volume (Technetium99m) is estimated at 8.2 ml(n equale 11).

Acrylic Resins↗