Femoral neck arthroplasty after failed resurfacing: brief report.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S B Goodman.
Explore the source record for details and available documents.
Clinical and laboratory data were compared in 72 patients with localized periodontitis (LP) and 103 patients with generalized periodontitis (GP). Significantly more LP than GP cases had decreased neutrophil chemotaxis (CTX), and were seropositive for Actinobacillus actinomycetemcomitans (Aa). Significantly, more GP cases were seropositive for Bacteroides gingivalis (Bg). All clinical indices were similar on affected teeth in LP and GP, but the attachment loss was greater on clinically unaffected teeth in GP when compared with LP. LP cases with CTX defects had a significantly lower mean age, were more often seropositive for Aa antibodies, and were more often female than LP patients with normal CTX. Significantly more GP cases with CTX defects were seropositive for Aa antibody. GP patients with normal CTX had a higher plaque index on both affected and unaffected teeth than did GP patients with a CTX defect. Our data suggest that chemotaxis and/or specific bacteria may be contributory, but not always necessary, factors in these disorders. The overlap in clinical and laboratory profiles of LP and GP continues to cloud the distinction of these early onset forms of periodontitis.
The clinical and roentgenologic data from 31 excised components from 19 revision arthroplasty cases were correlated with the histology and biochemistry of the membrane at the bone-cement or bone-prosthesis interface. Twenty-seven components were cemented and four were uncemented. Twenty-four implants were clinically and roentgenologically loose, one was possibly loose, and six were well fixed. Loose components, whether cemented or not, demonstrated statistically higher prostaglandin E2 levels in the surrounding membrane compared to the nonloose group. Collagenase and M-collagenase levels were absent or insignificantly low in all specimens; no detectable interleukin 1 beta was found. This suggests that prostaglandin E2 may be associated with the bone lysis associated with prosthesis loosening.
Clinical, radiographic and histologic findings are reported in a patient who underwent a hip shelf procedure 24 years previously. While the histologic observations confirm the presence of metaplasia of the surgically formed articular surface to fibrocartilage, there are superadded degenerative changes morphologically similar to those seen in degenerative arthritis.
The purpose of this study was to investigate whether the salvage in the recovery room of blood from the drainage tubes of patients who had total joint arthroplasty was both feasible and efficacious. The cases of seventy-four patients who had seventy-six consecutive total hip or knee arthroplasties were studied prospectively. Intraoperative salvage of blood was performed using the Cell Saver. After closure of the fascial layer or joint capsule, the drainage tubes were connected to the Cell Saver in the operating room and remained connected in the recovery room for a mean of 2.9 hours. Blood that was collected in the recovery room was then processed and transfused back to the patient. The average amount of blood that was salvaged after different types of arthroplasty varied. The addition of bone cement to the acetabular side during primary total hip replacement decreased the amount of postoperative bleeding and of salvaged blood (p = 0.018), whereas cementing the femoral component had no statistically significant effect. Revision total hip replacement also resulted in more bleeding and in the collection of more blood in the recovery room than did primary total hip replacement (p = 0.03), especially if cement was not used (p less than 0.001). There were no statistical differences in the amount of blood that was collected in the recovery room after unilateral, bilateral, primary, or revision total knee replacement.(ABSTRACT TRUNCATED AT 250 WORDS)
A 71-year-old woman incurred an unstable, comminuted supracondylar fracture of the femur above the tip of a GUEPAR prosthesis. The prosthesis was not loose. Immediate open reduction and internal fixation were performed using a segment cut from an intramedullary rod. This provided axial alignment and functioned as an internal stent with stable fixation of the fracture. Supplementary fixation with a plate and screws, cerclage wires, and an autogenous bone graft led to early mobilization, solid bony union, and an excellent functional result.
Fourteen mature New Zealand white female rabbits underwent implantation of a bulk pellet and of particulate (less than 1,000 micron) ultra-high-molecular-weight polyethylene (UHMWPE), through a drill hole in the proximal right tibia. The left tibia served as a drilled but nonimplanted control. The rabbits were killed after 16 weeks. Histologic examination of the bone-implant interface in the bulk UHMWPE group disclosed a fibrous tissue membrane with infrequent giant cell and histiocytic clusters at surface irregularities. The particulate group demonstrated positively birefringent UHMWPE fragments, rimmed by foreign body giant cells and histiocytes, embedded in a loose connective tissue. The histologic response to particulate UHMWPE is similar to that seen surrounding loose total joint arthroplasties in humans.
Twenty-one infected total hip arthroplasties in 19 patients performed between 1971 and 1982 were prospectively followed, using a computerized standard orthopaedic arthritis record. These cases represent an inclusive and unselected, consecutive series. The mean follow-up period from time of infection was 4.8 years (range, 1.2-11.7 years). Infection was diagnosed by positive bacteriologic culture. Ten hips grew a staphylococcal species, 5 a single gram-negative organism, 1 a Streptococcus, and 5 multiple organisms. At final follow-up evaluation, only three hips (14%) had the previously infected prosthesis still in situ, and these had no evidence of ongoing deep infection. Five additional hips (24%) were successfully salvaged after one- or two-stage prosthetic exchange. Two hips (10%) have an infected prosthesis in situ. Eleven hips (52%) had resection arthroplasty, three after attempts at prosthetic reinsertion. Therefore, at final follow-up evaluation, only 8 of the 21 hips (38%) have an apparently infection-free salvaged or reinserted prosthesis in place. Good prognostic factors for prosthetic salvage/successful reinsertion include Staphylococcus epidermidis infection and a traumatic etiology necessitating later hip arthroplasty. Poor prognostic factors include infection with Staphylococcus aureus or multiple organisms and a preoperative diagnosis of avascular necrosis.
Explore the source record for details and available documents.
Familial aggregation of early onset or juvenile periodontitis (JP), a disorder that varies in expression and age of onset, has been recognized for some time. Autosomal recessive and X-linked inheritance patterns have been suggested, and one large pedigree has demonstrated autosomal dominant inheritance. The variability and age limitations in clinical phenotypic diagnosis present several problems to genetic analysis, because information on members of the youngest and older generations may be lost to the analysis. The purpose of the present study was to elucidate the genetic basis of JP by formal pedigree analysis and comparison of competing genetic models. Twenty-eight families were included, with general and specific autosomal models, and an X-linked model being compared. The autosomal recessive model provided the most parsimonious explanation of the data, and its likelihood was not significantly different from the more general model. Likelihoods for the sporadic (nongenetic) and X-linked models were considerably lower than the autosomal models. While comparison of genetic models suggests recessive inheritance of JP, the serious complications to pedigree analysis posed by limitations warns against acceptance of this conclusion, without more exhaustive evaluation of: (1) a more extensive collection of family data, (2) more complete investigation of the effects of age limitations on comparisons among competing models, and (3) elucidation of the importance of diagnosis and phenotype assignment of adults through past dental records.
Five pelvises were photographed, roentgenographed, and sequentially sectioned or reamed to determine the location and appearance of the acetabular teardrop figure. The teardrop is located inferomedially in the acetabulum, just superior to the obturator foramen. The lateral lip is the exterior, and the medial lip is the interior of the acetabular wall. The ilioischial line projects over the medial acetabulum only fortuitously on the straight anteroposterior (AP) roentgenogram. Because of parallax, the relationship between the ilioischial line and the teardrop changes for views varying as little as 10 degrees in horizontal obliquity from the true AP roentgenogram. Because the teardrop comprises a well-defined, constant portion of the medial acetabular wall whereas the ilioischial line does not, the authors recommend using the acetabular teardrop rather than the ilioischial line for the detection and measurement of medial and superior acetabular migration.
Twenty-one mature New Zealand white female rabbits were allocated into three groups of seven rabbits. Group I received a bolus of doughy Simplex polymethylmethacrylate (PMMA) cement injected into the proximal tibia through a drill hole. Group II received a preformed, cooled, bulk PMMA pellet. Group III had particulate PMMA powder implanted. The operated, but nonimplanted, left tibiae served as controls. Animals were killed after four months. Histologically, both Group I and Group II demonstrated a thin, fibrous tissue membrane at the implant interface. Particulate PMMA (Group III) stimulated a much thicker, florid, foreign body reaction composed of histiocytes and giant cells. The foreign body response to particulate acrylic cement was similar to that seen in failed cemented joint replacement arthroplasty in humans.
Explore the source record for details and available documents.
Twelve surface replacement arthroplasties were performed on the hips of ten mongrel dogs using scaled-down replicas of the Wagner prosthesis. The contralateral hips and two further animals served as nonoperated controls. Animals were killed 5 months postoperatively. Clinical, radiological, histological and fluorochrome-labelling studies were employed to assess the bony and soft tissue reaction to resurfacing arthroplasty. There was no clinical or radiographic evidence of prosthetic loosening. Histological examination disclosed a thick foreign body and chronic inflammatory membrane containing acrylic cement and polyethylene wear particles at the bone-cement interface of both components. Generally, the bone marrow and trabecula were viable. There was evidence of increased bony remodelling and new bone formation in the subchondral area. The similarity between the above findings and those of aseptic component loosening in man suggests a mechanism whereby wear debris initiate a biological foreign body reaction culminating in component loosening.
Thirty-two cemented revision hip arthroplasties done with a straight-stem Muller prosthesis were reviewed an average of 3 years after operation (range, 2-4.4 years). Acetabular revision, performed in 29 cases, we done with a support ring, mesh, or bone graft in 18 of 29 (62%) cases. Acetabular and femoral cement pressurization techniques were not used. Trochanteric osteotomy was done in 15 cases (47%). The average patient age was 60.2 years (range, 20-85 years). Based on the clinical rating system of Swanson and Evarts, there were 21 (65.6%) excellent, 2 (6.3%) good, 8 (25%) fair, and 1 (3.1%) poor results. The clinical outcome was better after revision from a resurfacing arthroplasty (87.5% good/excellent results) than from uni/bipolar or total hip arthroplasty (60%). Radiographic examination suggests that two femoral components and one acetabular component are loose. These patients have a fair clinical rating. None have been revised. Trochanteric wire breakage (60%) and displacement (26.7%) was common if trochanteric osteotomy was done.
The radiographs of 97 patients (117 hips) who had a straight-stem Muller femoral component and a non-metal-backed acetabular component were reviewed to determine whether the mode of acetabular loosening predicted by finite element stress analysis (FESA) is observed clinically. The follow-up period averaged 3.1 years (range, 2.0-4.6 years). Significantly more lucent lines were present in zones 1 and 3, compared with zone 2 (P less than .01). This finding corroborates the predictions of FESA and suggests that the production of acetabular lucent lines is due in part to chronic mechanical overload.
In a retrospective study of 130 primary total hip arthroplasties with a self-locking straight stem femoral component (Muller) and low profile cup, the average follow-up evaluation was 3.1 years (range, 2.0-4.6 years). According to the clinical rating system modified from Swanson and Evarts, there were 115 (88.3%) excellent, six (4.7%) good, four (3.1%) fair, and five (3.9%) poor results. Radiolucent lines at least 1 mm in width were noted in 12.8% of acetabula, mostly in Zones 1 and III. One cup has been revised and one is awaiting revision. Radiolucent lines greater than or equal to 1 mm were noted around 26.5% of femoral components. These were asymptomatic, unless associated with the presence of infection, subsidence greater than 5 mm, or symptoms of acetabular loosening. True femoral subsidence was pain free and nonprogressive in seven patients (6%) if less than or equal to 5 mm. Femoral loosening was roentgenographically observed as component migration or subsidence greater than 5 mm. By these criteria, three femoral components (2.6%) were loose, although none have been revised.
Fracture of a polyethylene acetabular cup is rare. Current theories of its cause emphasize wear of the component. The case reported illustrates the presence of a loosening membrane in association with cup fracture. Histologic study of the loosening membrane indicated a foreign-body reaction to polyethylene and acrylic wear particles. The authors propose a theory relating micromotion of the acetabular component to the production of particles of wear with a subsequent foreign-body reaction followed by further loosening. The erosion of bony support leads to the concentration of stress at the junction of the supported and unsupported segments. This may ultimately result in fracture of the cup.