Search PubMed⌕ Search

Biomedical subjects

S B Goodman

Publications and source records attributed to S B Goodman.

At least 91 records · Page 5Linked to original sources

Thromboembolism following multiple trauma.

The true incidence of thromboembolic complications following multiple trauma is unknown, and no method of prophylaxis has been shown to be both safe and effective in managing seriously injured patients. In this prospective study, 113 trauma patients were assigned on admission to receive either low-dose heparin (LDH), (5,000 U subcutaneously every 12 hours) or to wear sequential compression devices (SCDs) as prophylaxis against the development of deep venous thrombosis (DVT). Both groups of patients were serially studied with duplex venous ultrasound imaging to detect thrombus in the veins of the thigh. Ventilation-perfusion lung scans and pulmonary angiograms were performed when pulmonary embolism (PE) was suspected clinically. There were 12 patients who had thromboembolic complications, including 9 of 76 in the SCD group (12%) and 3 of 37 in the LDH group (8%). Five patients had DVT only, four had PE without detectable DVT, and three had both DVT and PE. None of the patients with PE died, and there were no major complications associated with either method of prophylaxis. Compared with the patients who did not develop DVT/PE, those with thromboembolic complications were older (49 +/- 23 vs. 36 +/- 17 years, p less than 0.02), spent more hospital days immobilized (24 +/- 15 vs. 10 +/- 13 days, p less than 0.001), received more transfusions (11 +/- 12 vs. 3 +/- 5 U, p less than 0.001) and had clotting abnormalities on admission, as demonstrated by prolonged PTT values (39 +/- 28 vs. 26 +/- 5 seconds, p less than 0.001). It appears that there is an identifiable subgroup of injured patients at highest risk for PE who warrant both prophylaxis and close surveillance for DVT.

Adolescent↗

Preoperative templating for the equalization of leg lengths in total hip arthroplasty.

The method and results of preoperative templating for the re-establishment of leg length equality during total hip replacement (THR) are reported. The method is a modification of the technique of Müller and requires an anteroposterior radiograph of the pelvis that includes the proximal third of both femora, appropriate acetabular and femoral templates, and tracing paper. To obtain equalization of leg lengths and tissue tension, a composite drawing is made of the operative plan, with all component sizes and important measurements clearly marked. During THR, the lesser trochanter is identified and the femoral neck is osteotomized after a direct measurement is made. These principles were followed in a prospective, consecutive series of 42 primary THR procedures performed by one surgeon. All the radiographic measurements were performed by a single observer. The leg length discrepancy on the postoperative radiograph averaged 3mm (standard deviation = 3mm, range: -9 to +9mm). The postoperative clinical leg length discrepancy averaged 0mm (range: -10 to +10mm). None of the patients complained of leg length inequality. Preoperative templating allows different alternatives to be traced on paper prior to the actual surgical procedure. This method also helps determine the requirements for special prosthetic implants. Acceptable results for postoperative leg length equality may be reliably achieved using this method.

Bone Lengthening↗

Prostaglandin E2 production by the membrane surrounding loose and fixated cemented tibial hemiarthroplasties in the rabbit knee.

Sixteen mature New Zealand female rabbits had cemented, tibial hemiarthroplasty of the right knee (correction of hip) using a stemmed, fluted, titanium-alloyed, condylar type prosthesis. In the fixated prosthetic group (eight rabbits), a 1.5-cm3 doughy bolus of polymethylmethacrylate (PMMA) was used to cement the prosthesis firmly. In the loose group (eight rabbits), the cement was allowed to cure ex vivo on the implant; the prosthesis was then implanted and rotated to ensure that it was loose fitting. Roentgenograms performed postoperatively and at three months were graded for new lucent lines. The implant area was harvested aseptically and cultured during a three-day period, and the cumulative collection of tissue culture supernatants was assayed for prostaglandin E2 (PGE2). The mean cumulative grading of new lucent lines was 0.4 +/- 0.2 (mean +/- SEM) for the fixated prosthetic group and 2.3 +/- 0.5 for the loose prosthetic group. Specimens from the nonloose group produced 8.85 +/- 1.44 ng of PGE2 on the right prosthetic side, and 17.29 +/- 3.72 ng of PGE2 on the left, nonimplanted side. Specimens from the loose prosthesis group produced 52.35 +/- 16.28 ng of PGE2 on the right prosthetic side and 17.29 +/- 3.72 ng of PGE2 on the left, nonimplanted side. Increased PGE2 production relative to fixated prostheses was noted in the membranes surrounding loose prostheses. The left, nonimplanted sides were not statistically different. Roentgenographic and biochemical evidence indicates that a cemented tibial hemiarthroplasty implanted in the rabbit knee can provide a short-term model of arthroplasty loosening.

Animals↗

Computerized tomographic evaluation of acetabular anatomy.

In this study, accurate identification of the location of the acetabular teardrop and ilioischial line on the cadaveric pelvis was attempted using computerized tomographic (CT) scanning and conventional roentgenographic techniques. The acetabular teardrops and ilioischial lines of four whole pelvic anatomic specimens were outlined with barium impregnated latex strings utilizing conventional roentgenograms, fluoroscopy, and stereoscopic control. Computed tomographic scanning was then performed, and axial and coronal CT reformations were created. Roentgenograms, CT scans, and magnetic resonance images of the pelves of ten patients with avascular necrosis of the femoral head were also reviewed to correlate the cadaveric study with specific clinical cases. The acetabular teardrop is a U-shaped figure on roentgenograms taken in a neutral anteroposterior projection. It is a complex geometric structure found to be in a constant position in the anteroinferior aspect of the acetabular wall. Its appearance changes with rotation of the pelvis or incident beam, as the teardrop represents a two-dimensional image of the tangents of a series of curves of varying radii. The ilioischial line is located posterior to the acetabulum and corresponds to tangents on the cortex of the posterior column. Computed tomography imaging with reconstruction identifies acetabular anatomy most clearly and allows precise measurements to be made.

Acetabulum↗

A biomechanical study of two methods of internal fixation of unstable fractures of the femoral neck. A preliminary study.

A model of an unstable femoral neck fracture was used in this study to compare the axial and torsional displacement obtained when the neck was fixed by a compression hip screw (CHS) and side plate, or three Knowles pins. Six paired, embalmed femora were mounted on a special, custom-made jig that grasped the femoral head and shaft securely. A standardized osteotomy was made with an oscillating saw, bisecting the distance between the lower cartilaginous portion of the femoral head and the intertrochanteric line. A 5-mm thick slice of bone was excised from the posteromedial quadrant of the distal fragment. The right or left femur in each pair was then randomly assigned to internal fixation with either three Knowles pins or a keyed CHS plus a 130 degrees four-hole side plate. After potting of the specimens and application of rosette strain gauges, axial displacements were measured during the application of in-plane and out-of-plane compressive loads. The resistance to torsion was also determined. There were no statistical differences between the two devices for compressive or torsional loading using this model.

Biomechanical Phenomena↗

Quantitative comparison of the histological effects of particulate polymethylmethacrylate versus polyethylene in the rabbit tibia.

Fourteen mature female New Zealand White rabbits underwent implantation of Simplex polymethylmethacrylate (PMMA) powder or particulate (average 67 microns) ultrahigh-molecular-weight polyethylene (UHMWPE) through a drill hole in the proximal right tibia. The left tibia functioned as a prepared but nonimplanted control. Animals were killed after 16 weeks. Histological examination of the bone-implant interface in the particulate PMMA group disclosed a florid foreign-body reaction with the presence of giant cells and histiocytes. The particulate UHMWPE group demonstrated positively birefringent UHMWPE fragments, rimmed by foreign-body giant cells and histiocytes, embedded in a loose connective tissue stroma. UHMWPE interfaces were thicker and contained more histiocytes and fibrocytes; PMMA interfaces contained more marrow cells and lymphocytes. This study underscores the importance of biomaterial debris in the process of aseptic loosening of cemented joint arthroplasties.

Animals↗

Modulation of the membrane surrounding particulate cement and polyethylene in the rabbit tibia.

Twenty-nine mature New Zealand white, female rabbits were divided into four groups. Using sterile technique, a 6 mm drill hole was made in the tibia 1 cm distal to the knee joint. The marrow was scooped out underneath the hole. The right tibia received Simplex particulate cement polymer (PMMA) (groups 1 and 2) or polyethylene particles (UHMWP) (groups 3 and 4). The left leg functioned as a prepared but non-implanted control. All animals were fed a standard diet; those in groups 1 and 3 received plain water, while groups 2 and 4 drank water in which sodium naproxen was dissolved (1.375 mg/ml). Animals were killed after 16 wk. The implant area was harvested and grown in tissue culture. The cumulative collection of tissue culture supernatants over 3 d was assayed for prostaglandin E2 (PGE2) via radioimmunoassay. PGE2 production was significantly higher in the membrane harvested from the right side containing particulate cement with no sodium naproxen (group 1) compared with controls (P less than 0.05). The ratio of PGE2 values for the right divided by the left side yielded higher values in group 1, compared with groups 2, 3 or 4 (P less than 0.01). Previous studies have suggested that particulate debris and PGE2 production are associated with arthroplasty loosening. This experiment has demonstrated that PGE2 production by the membrane surrounding particulate debris can be suppressed by the administration of oral sodium naproxen. Because non-steroidal anti-inflammatory drugs are known to inhibit prostaglandin synthesis in man, these agents may prove useful in retarding the bone loss associated with early prosthetic loosening.

Animals↗

Mechanical overload of a single compartment induces early degenerative changes in the rabbit knee: a preliminary study.

The purpose of this experiment was to determine whether mechanical overload of a single compartment of the knee in rabbits via proximal tibial osteotomy could produce early changes consistent with degenerative arthritis. Ten New Zealand white female rabbits were allocated into two groups. Group 1 (five animals) underwent a right 20 degrees valgus proximal tibial osteotomy to overload the lateral compartment of the knee. Group 2 (five animals) underwent a tibial osteotomy without malalignment (sham controls). The osteotomies were stabilized with a mini AO/ASIF plate and screws, allowing early mobilization. The left leg in each animal was left intact and served as a control. Animals were sacrificed after 3 months. Histological grading of the cartilage was performed according to Mankin et al. The mean histological gradings for the right minus the left knee were the same for the lateral and medial compartments in the 0 degrees sham osteotomy group. However, the mean histological grading of the "overloaded" lateral compartment was 2.4 times greater than the medial compartment in the 20 degrees valgus osteotomy group. These findings suggest that histological evidence of degenerative changes can be surgically induced in the rabbit knee by creating a biomechanical overload of one compartment.

Animals↗

Treatment of comminuted femoral subtrochanteric fractures using the Russell-Taylor reconstruction intramedullary nail.

Seven patients with comminuted subtrochanteric fractures of the femur were treated with Russell-Taylor reconstruction intramedullary nails. Six of the seven fractures were AO/ASIF Type C and had resulted from high-energy trauma. The average time to clinical union was 10.5 weeks--a considerable improvement over what has been achieved with other methods. There were no delayed unions, nonunions, infections, or implant failures, either postoperatively or during follow up, which averaged 20.8 months (range: 16 to 28). The Russell-Taylor device offers mechanical and biologic advantages, and extends the indications for locked intramedullary nailing to include fractures at the level of or including the lesser trochanter.

Adult↗

Suppression of prostaglandin E2 synthesis in the membrane surrounding particulate polymethylmethacrylate in the rabbit tibia.

Fifteen mature, New Zealand, female rabbits were divided into two groups. Using sterile technique, a 6-mm drill hole was made in the tibia 1 cm distal to the knee joint bilaterally. The marrow was scooped out underneath the hole. The right tibia received Simplex particulate cement polymer and the left leg functioned as a prepared, but nonimplanted, control. All animals were fed a standard diet. Whereas the six animals in Group 1 received regular water, the nine animals in Group 2 drank water in which sodium naproxen was dissolved (1.375 mg per ml). The animals were killed after 16 weeks. The implant area was harvested under sterile conditions and maintained in tissue culture. The cumulative collection of tissue culture supernatants over a three-day period was assayed for Prostaglandin E2 (PGE2) via radioimmunoassay. Specimens from Group 1 produced an average of 106.0 +/- 10.9 ng PGE2 on the right side, and 35.3 +/- 6.0 ng PGE2 on the left side. Specimens from Group 2 produced an average of 31.1 +/- 6.1 ng PGE2 on the right experimental side and 26.0 +/- 5.1 ng PGE2 on the left control side. The ratio of PGE2 values for the right divided by the left side yielded higher values in Group 1, compared to Group 2. Cement polymer particles have been shown to produce a florid foreign body histologic reaction similar to that associated with prosthetic loosening in man. This experiment has demonstrated that the increased PGE2 production by the membrane surrounding particulate cement polymer can be suppressed by the administration of an oral cyclo-oxygenase inhibitor. PGE2 has been previously shown to induce bone resorption in vivo and in vitro. The use of nonsteroidal antiinflammatory drugs may be indicated in retarding the bone loss associated with early prosthetic loosening.

Animals↗

The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibia.

This study examines the histological effects of different sizes of polyethylene particles implanted into the rabbit tibia. Seventeen mature New Zealand white female rabbits were allocated into three groups. Group 1 (5 rabbits) received polyethylene particles averaging approximately 16 microns in diameter, implanted into the right proximal tibia through a drill hole. Group 2 (5 animals) received particles averaging 26 microns, and Group 3 (7 rabbits) received particles averaging 67 microns. The left tibia was drilled but not implanted. Animals were sacrificed after 16 weeks. Histological analysis disclosed decreased hematopoietic activity within the left tibial drill hole. In all groups, the right tibia demonstrated positively birefringent polyethylene particles surrounded by, and within (smaller particles), histiocytes and giant cells in a fibrous tissue stroma. Statistical analysis disclosed more fibrocytes and less marrow cells at the interface of Group 3 (largest particles) compared to Group 1 and 2. Larger polyethylene particles, being less readily phagocytosed, appear to produce more fibrous encapsulation, compared to particles of a smaller size. The histological reaction stimulated by the different sizes of polyethylene particles resembled the membrane surrounding loose joint arthroplasties in humans.

Animals↗

The effects of bulk versus particulate titanium and cobalt chrome alloy implanted into the rabbit tibia.

Twenty-eight mature New Zealand white female rabbits were allocated into 4 groups of 7 rabbits. Group 1 received a coiled wire of cobalt chrome alloy (Vitallium) (16 gauge x 1 cm). Group 2 received an equal weight of cobalt chrome particles averaging 15.4 microns in diameter. Group 3 received a coiled wire implant of commercially pure (C.P.) titanium (16 gauge x 1 cm). Group 4 received the same weight of C.P. titanium particles averaging 3.8 microns. The implants were placed through a drill hole in the proximal right tibia; the left tibia served as a prepared but nonimplanted control. The animals were killed after 16 weeks and quantitative histology was performed on undecalcified sections of the implant area. Bulk cobalt chrome and titanium implants were surrounded by a thin, incomplete, fibrous tissue layer with decreased numbers of cells. Trabeculae of bone were present within this connective tissue envelope. Fingerlike projections of bone enveloped the implant where it abutted endosteal bone. Clumped and loosely scattered cobalt chrome and titanium particles were surrounded by a minimal amount of fibrous connective tissue. Smaller particles were present within cells. Hematopoietic cells abutted the bulk or particulate implants directly. There was no evidence of acute or chronic inflammation or foreign body reaction. These results should be contrasted with those of Howie et al. in which intraarticular cobalt chrome particles stimulated a rapid proliferation of macrophages and synovial degeneration after 1 week. This may be due to a direct toxic effect of metals in an intra-articular environment, the smaller particle size used in that study, or to abrasive injury to the hyaline cartilage and subsequent synovitis. Our results underscore the general inert properties of these metals in the short term, when implanted into bone in the sizes and physical forms chosen.

Animals↗

Benign versus pathologic compression fractures of vertebral bodies: assessment with conventional spin-echo, chemical-shift, and STIR MR imaging.

Differentiation of benign from pathologic compression fractures of vertebral bodies was evaluated with magnetic resonance imaging in a prospective study of 53 patients. Twenty-six patients had 34 benign posttraumatic compression fractures. Twenty-seven patients had metastatic disease to the vertebral column and seven pathologic fractures. T1- and T2-weighted spin-echo (SE) sequences (1.5 T) were performed in all patients. A presaturation technique was used to obtain "fat" and "water" images to better assess the degree of normal fatty marrow replacement in fractured vertebrae. Short inversion-time inversion-recovery (STIR) images were also obtained. Discrimination between benign and pathologic compression fractures was generally possible with the SE sequences. Chronic benign fractures demonstrated isointense marrow signal intensity (SI), compared with that of normal vertebrae with all sequences. Pathologic fractures showed low SI on T1-weighted images and high SI on T2-weighted images. Fat images revealed complete replacement of normal fatty marrow, shown as absent SI in the involved vertebral body. Water and STIR images showed diffuse high SI in pathologic fractures, with STIR images having the highest contrast between abnormal and normal marrow. Acute benign compression fractures also demonstrated high SI on T2-weighted, water, and STIR images, but the SI was less pronounced and the pattern was generally more inhomogeneous than that of pathologic compressions. In general, fat images showed only partial replacement of normal fatty marrow by low SI, in contrast to the complete absence of marrow SI typical of pathologic fractures.

Adolescent↗

Comparison of radiographic parameters for analysis of normal and dysplastic hips in the adult.

Radiographic quantitation of the dysplastic hip in adults is difficult. This study compares the values for commonly used indices, the acetabular angle (AA), the center edge angle (CEA), and femoral head coverage, and the X-Y coordinate system on the anteroposterior pelvic radiograph in 30 adult patients with 60 normal hips, and 20 adult patients with 27 dysplastic hips. Dysplastic hips demonstrated significantly higher values for the AA and the X-Y coordinates, and significantly lower values for the CEA and femoral head coverage compared to normal hips. Femoral head coverage in dysplastic hips correlated best (negatively) with the Y coordinate, i.e., poorer coverage was associated with greater superior migration of the femoral head. The AA describes the slope of the acetabular roof, but does not take into account the relative position of the femoral head. The CEA measures the position of the femoral head in relation to the lateral lip of the acetabulum, but does not necessarily use the true acetabulum. The X-Y coordinate system relates the center of the femoral head to an identifiable acetabular landmark, the teardrop shadow. These coordinates are easily determined and can serve as an adjunct to other radiographic indices that quantitate the amount of subluxation in dysplastic hips in adults.

Acetabulum↗

Prostaglandin E2 levels in the membrane surrounding bulk and particulate polymethylmethacrylate in the rabbit tibia. A preliminary study.

Fourteen mature New Zealand white female rabbits were allocated into two groups. Group 1 received a bolus doughy Simplex polymethylmethacrylate (PMMA) cement injected into the proximal tibia through a drill hole. Group 2 received an equal volume of particulate PMMA cement powder. The operated but nonimplanted left tibiae served as controls. The animals were killed after four months. The membrane surrounding the implant area was harvested aseptically and grown in tissue culture. The supernatants were assayed for prostaglandin E2 (PGE2) via radioimmunoassay. Bulk cement specimens produced on average 12.39 +/- 4.11 ng PGE2 on the right experimental side and 12.29 +/- 3.56 ng PGE2 on the left control side (not statistically different). Cement powder specimens produced 8.82 +/- 1.64 ng PGE2 on the right experimental side, which was statistically different from 4.21 +/- 0.88 ng PGE2 produced on the left control side. The ratio of PGE2 values for the right divided by the left side and the arithmetic difference between right and left sides were significantly higher in the particle group compared with the bulk group. Small, undigestable cement particles may be phagocytosed by foreign-body giant cells and histiocytes and then extruded into the extracellular compartment, along with substances such as PGE2. PGE2 has been implicated as the biologic mechanism for stimulating the bone lysis associated with prosthetic loosening.

Animals↗

Compartment syndrome after intramedullary nailing of the tibia.

Three patients had compartment syndrome of the leg after tibial intramedullary nailing with reaming. They were all treated successfully with emergency fasciotomy. A prospective study was done of seven additional patients who had continual monitoring of the pressure in the deep posterior compartment during tibial intramedullary nailing with reaming. In five of them, the procedure was performed three weeks or less after injury and in the remaining two, the nailing was performed later for the treatment of non-union. Two pressure peaks in the deep posterior compartment were noted: one after strong longitudinal traction was applied and the fracture was reduced and the other during intramedullary reaming. Intraoperative pressure of thirty millimeters of mercury or more were recorded in three of the seven patients. In the treatment of tibial fractures, operative procedures that involve forceful traction for a long time may predispose the patient to compartment syndrome in the leg. Close clinical observation of such patients is needed. When there is a high risk of compartment syndrome, monitoring of the pressure in the compartment may be prudent.

Adolescent↗

The influence of continuous passive motion on outcome in total knee arthroplasty.

All primary condylar total knee replacement arthroplasties (TKAs) performed from 1977 to 1984 at the authors' institution were divided into two groups based on the use of continuous passive motion (CPM) in the immediate postoperative period. The control group consisted of 73 patients who were treated with 95 TKAs without postoperative CPM. The average age was 65.4 years. The study group consisted of 38 patients who had 51 TKAs in which CPM was used postoperatively. The mean patient age was 62.8 years. The most common diagnoses in both groups were osteoarthritis and rheumatoid arthritis. Range of motion (ROM) was recorded preoperatively, at discharge, at three months, one year, two years, and at the last follow-up visit. There were no statistically significant differences in the ROM between the two groups at any of these time periods. At two years, the mean flexion and extension in the study group were 99 degrees and -4 degrees, respectively, compared to 103 degrees and -5 degrees in the control group. The average hospital stay was 11.2 days in the study group, whereas it was 15.1 days in control group. In the control group, there was one superficial infection, no deep infections, and four pulmonary emboli compared with three superficial infections, two deep infections, and no pulmonary emboli in the study group. There was no difference in the transfusion requirements between the two groups. CPM is advocated by the authors to help achieve discharge ROM earlier, but the protocol has been changed to begin CPM on the second postoperative day to allow the wound to stabilize.

Adult↗