Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography.

BACKGROUND: Multislice spiral computed tomography (MSCT) with retrospectively ECG-gated image reconstruction permits coronary artery visualization. We investigated the method's ability to identify high-grade coronary artery stenoses and occlusions. METHODS AND RESULTS: A total of 64 consecutive patients were studied by MSCT (4x1 mm cross-sections, 500-ms rotation, table feed 1.5 mm/rotation, intravenous contrast agent, retrospectively ECG-gated image reconstruction). All coronary arteries and side branches with a luminal diameter >/=2.0 mm were assessed concerning evaluability and the presence of high-grade stenoses (>70% diameter stenosis) or occlusions. Results were compared with quantitative coronary angiography. Of 256 coronary arteries (left main, left anterior descending, left circumflex and right coronary artery, including their respective side branches), 174 could be evaluated (68%). In 19 patients (30%), all arteries were evaluable. Artifacts caused by coronary motion were the most frequent reason for unevaluable arteries. Overall, 32 of 58 high-grade stenoses and occlusions were detected by MSCT (58%). In evaluable arteries, 32 of 35 lesions were detected, and the absence of stenosis was correctly identified in 117 of 139 arteries (sensitivity, 91%; specificity, 84%). If analysis was extended to all stenoses with >50% diameter reduction, sensitivity was 85% (40 of 47) and specificity was 76% (96 of 127). CONCLUSIONS: MSCT with retrospective ECG gating permits the detection of coronary artery stenoses with high accuracy if image quality is sufficient, but its clinical use may presently be limited due to degraded image quality in a substantial number of cases, mainly due to rapid coronary motion.

Aged↗

Visualization of coronary artery anomalies and their anatomic course by contrast-enhanced electron beam tomography and three-dimensional reconstruction.

Anomalous coronary arteries are rare conditions. However, they may cause myocardial ischemia and sudden death and their reliable identification is crucial for any imaging method that attempts coronary artery visualization. We studied the ability of contrast-enhanced electron beam tomography (EBT) to identify anomalous coronary arteries and their course. Thirty patients with previously identified coronary anomalies and 30 subjects with normal coronary anatomy were studied. By EBT, 40 to 50 axial images of the heart (3-mm slice thickness, 1 mm overlap, electrocardiographic trigger) were acquired in a single breathhold during continuous injection of contrast agent (160 ml, 4 ml/s). Based on the original images and 3-dimensional reconstructions, the EBT data were analyzed by 2 blinded observers as to the presence of coronary anomalies and their course. Results were compared with invasive angiography. EBT correctly identified all normal controls and all patients with coronary anomalies. The anatomic course of the coronary anomalies was correctly classified in 29 of 30 patients (97%), including right-sided origin of the left main coronary artery (n = 4) or of the left circumflex coronary artery (n = 15), left-sided origin of the right coronary artery (n = 9), and 1 coronary fistula from the left circumflex coronary artery to the right atrium. Only the distal anastomosis of a second fistula from the left circumflex coronary artery to a bronchial artery was not correctly identified. This study demonstrates that contrast-enhanced EBT is a reliable noninvasive technique to identify anomalous coronary arteries and their course.

Adult↗

Variability of repeated coronary artery calcium measurements by electron beam tomography.

In 120 patients, the mean interscan variability of coronary calcium quantification by electron beam tomography was 19.9% (median 7.8%) for the traditional calcium score, and 16.2% (median 5.7%) for volumetric scoring. Although this difference was not significant, there was a significant influence of the total amount of calcium, number of acquired images, and image noise on interscan reproducibility.

Aged↗

Recommendations for standardization of EBT and MSCT scanning.

BACKGROUND: The detection and quantification of coronary calcifications by electron beam tomography (EBT) permits to diagnose coronary atherosclerosis in an early stage. Initial reports indicate that multislice spiral CT (MSCT) also permits the quantification of coronary calcium, while equivalency to EBT has not been definitely proven. Since image acquisition, reconstruction and evaluation parameters influence the results of calcium quantification with CT techniques, standardization of the investigation is mandatory to make results comparable. AIM: The article summarizes guidelines for image acquisition and evaluation by EBT and describes guidelines and consensus reports that were issued concerning the clinical use of the method.

Adult↗

Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.

BACKGROUND: We investigated the applicability and image quality of contrast-enhanced coronary artery visualization by multislice spiral CT using retrospective ECG gating. METHODS AND RESULTS: Twenty-five patients in sinus rhythm (significant coronary artery stenoses ruled out by invasive angiography) were studied with a multislice spiral CT (Siemens SOMATOM Volume Zoom). In inspiration (mean breath-hold, 37 seconds), a volume data set of the heart was acquired (intravenous contrast agent; 4 x 1-mm slice thickness; 500-ms rotation; table feed, 1.5 mm/360 degrees ). Simultaneous recording of the ECG permitted retrospective reconstruction of contiguous cross sections in intervals of 1 mm at any desired interval of the cardiac cycle. The mean duration of the image reconstruction window was 185 ms. Next to 3-dimensional reconstructions of the heart and coronary arteries, multiplanar reconstructions were rendered to determine the visualized length of the coronary arteries, the contrast-to-noise ratio, and the correlation of coronary artery diameters to quantitative coronary angiography. CONCLUSIONS: The coronary arteries could be visualized over long segments (left main, 9+/-4 mm; left anterior descending, 112+/-34 mm; left circumflex, 80+/-29 mm; right coronary artery, 116+/-33 mm). On average, 78+/-16% of these distances were visualized free of motion artifacts. The mean contrast-to-noise ratio was 9.3+/-3.3. Coronary artery diameters in multislice spiral CT showed close correlation to quantitative coronary angiography (CT, 3.3+/-1.0 mm; angiography, 3. 2+/-0.9 mm; mean difference, 0.38 mm; r=0.86). Contrast-enhanced multislice spiral CT permits visualization of the coronary artery lumen. Further studies are necessary to determine whether image quality is sufficient to reliably detect coronary artery stenoses.

Adult↗

Molecular characterization of the non-biotin-containing subunit of 3-methylcrotonyl-CoA carboxylase.

The biotin enzyme, 3-methylcrotonyl-CoA carboxylase (MCCase) (3-methylcrotonyl-CoA:carbon-dioxide ligase (ADP-forming), EC 6.4.1. 4), catalyzes a pivotal reaction required for both leucine catabolism and isoprenoid metabolism. MCCase is a heteromeric enzyme composed of biotin-containing (MCC-A) and non-biotin-containing (MCC-B) subunits. Although the sequence of the MCC-A subunit was previously determined, the primary structure of the MCC-B subunit is unknown. Based upon sequences of biotin enzymes that use substrates structurally related to 3-methylcrotonyl-CoA, we isolated the MCC-B cDNA and gene of Arabidopsis. Antibodies directed against the bacterially produced recombinant protein encoded by the MCC-B cDNA react solely with the MCC-B subunit of the purified MCCase and inhibit MCCase activity. The primary structure of the MCC-B subunit shows the highest similarity to carboxyltransferase domains of biotin enzymes that use methyl-branched thiol esters as substrate or products. The single copy MCC-B gene of Arabidopsis is interrupted by nine introns. MCC-A and MCC-B mRNAs accumulate in all cell types and organs, with the highest accumulation occurring in rapidly growing and metabolically active tissues. In addition, these two mRNAs accumulate coordinately in an approximately equal molar ratio, and they each account for between 0.01 and 0.1 mol % of cellular mRNA. The sequence of the Arabidopsis MCC-B gene has enabled the identification of animal paralogous MCC-B cDNAs and genes, which may have an impact on the molecular understanding of the lethal inherited metabolic disorder methylcrotonylglyciuria.

Acetyl-CoA Carboxylase↗

Image compression and chest radiograph interpretation: image perception comparison between uncompressed chest radiographs and chest radiographs stored using 10:1 JPEG compression.

We have assessed the effect of 10:1 lossy (JPEG) compression on six board-certified radiologists' ability to detect three commonly seen abnormalities on chest radiographs. The study radiographs included 150 chest radiographs with one of four diagnoses: normal (n = 101), pulmonary nodule (n = 19), interstitial lung disease (n = 19), and pneumothorax (n = 11). Before compression, these images were printed on laser film and interpreted in a blinded fashion by six radiologists. Following an 8-week interval, the images were reinterpreted on an image display workstation after undergoing 10:1 lossy compression. The results for the compressed images were compared with those of the uncompressed images using receiver operating characteristic (ROC) analyses. For five of six readers, the diagnostic accuracy was higher for the uncompressed images than for the compressed images, but the difference was not significant (P > .1111). Combined readings for the uncompressed images were also more accurate when compared with the compressed images, but this difference was also not significant (P = .1430). The sensitivity, specificity, and accuracy values were 81.5%, 89.2%, and 86.7% for the compressed images, respectively, as compared with 78.9%, 94.5%, and 89.3% for the uncompressed images. There was no correlation between the readers' accuracy and their experience with soft-copy interpretation; the extent of radiographic interpretation experience had no correlation with overall interpretation accuracy. In conclusion, five of six radiologists had a higher diagnostic accuracy when interpreting uncompressed chest radiographs versus the same images modified by 10:1 lossy compression, but this difference was not statistically significant.

Humans↗

[Is a general pharmacologic thromboembolism prophylaxis necessary in ambulatory treatment by plaster cast immobilization in lower limb injuries?].

Selected patients with minor lower limb injuries and low risk for deep vein thrombosis (DVT), who required cast immobilizing and did not receive medical thrombosis prophylaxis, were included in a prospective study. The decision to give not medical thrombosis prophylaxis depended on an concept of individualised prophylaxis for patients at risk for thromboembolism. From March 1994 to March 1996 in 178 outpatients (118 men, 60 women, mean age 25.8 [16-39] years) a clinical examination and a colour-coded duplex sonography were performed after removal of the cast for detection of DVT of the lower limb. A phlebography was performed when thrombosis was suspected. Two patients developed a one bundle thrombosis of the calf. Clinical appearance of lung embolism was not observed. These results suggest, that low risk patients with minor injuries of the lower limb and plaster cast immobilisation do not need a medical thrombosis prophylaxis.

Adolescent↗

[Internet communication in radiology].

UNLABELLED: E-mail is an Internet service that can be used for sending messages and binary files between individuals as well as for participating in discussion groups. For sending and receiving these types of messages, the users must use either a dedicated e-mail client or one of the several mailing facilities of the World Wide Web. The news-groups enable like-minded people to discuss subjects on a group-wide basis, but access is generally not limited, and the participants cannot be selected. CONCLUSION: The objective of this paper is to give radiologists an introduction to using e-mail, mailing lists and news-groups, the three most important communication services of the Internet. The function of these services is explained, and the advantages of implementing them in a radiology practice are discussed. Potential problems and concerns including security matters are highlighted, and ways in which they can be resolved are suggested.

Communication↗

[Radiological information searching on the Internet: data banks, search machines and intelligent agents].

UNLABELLED: The Internet plays an important role in a growing number of medical applications. Finding relevant information is not always easy as the amount of available information on the Web is rising quickly. Even the best search engines can only collect links to a fraction of all existing Web pages. In addition, many of these indexed documents have been changed or deleted. The vast majority of information on the Web is not searchable with conventional methods. New search strategies, technologies and standards are combined in intelligent search agents (ISA) and robots, which can retrieve desired information in a specific approach. CONCLUSION: The article describes differences between ISAs and conventional search engines and how communication between agents improves their ability to find information. Examples of existing ISAs are given and the possible influences on the current and future work in radiology is discussed.

Databases, Factual↗

[Glossary].

Explore the source record for details and available documents.

Internet↗

[Noninvasive imaging of coronary arteries with electron beam tomography (EBCT)].

Coronary angiography remains the diagnostic standard for establishing the presence, site, and severity of coronary artery disease. Electron beam computed tomography (EBCT), a non-invasive imaging method with very high spatial and temporal resolution, is well suited for cardiac imaging. Using a standard protocol, EBCT permits the visualization of the coronary arteries. Stenoses and occlusions of the native arteries and of coronary artery bypass grafts can be reliably diagnosed. Extremely calcified segments have to be excluded from evaluation. Reduced image quality, mainly due to fast vessel motion and superposition of large veins, impairs the results obtained for the right and left circumflex coronary artery. Possible clinical applications are the follow-up after angioplasty (PTCA without stent) and bypass surgery, the exclusion of coronary artery disease in patients with low likelihood of disease, and the evaluation of coronary anomalies.

Angioplasty, Balloon, Coronary↗

Imaging of the coronary arteries using magnetic resonance angiography.

Magnetic resonance imaging of the coronary arteries is difficult due to the tortuous course of these vessels, their small diameter, and their rapid movement caused by respiration and cardiac contraction. Initial investigations could demonstrate the feasibility of non-invasive magnetic resonance coronary angiography using 2-dimensional turbo-FLASH gradient-echo sequences in repeated breathholds of approximately 16 heart beats duration. Further developments, especially the design of navigator-echo-based respiratory gated 3-dimensional imaging sequences, permitted the acquisition of contiguous volume data sets of the heart which eliminated many limitations of 2-dimensional repeated breathhold sequences. With a spatial resolution of approximately 1.2 x 1.2 x 2 mm and a temporal resolution of approximately 126 ms, several authors reported sensitivities of 70-80% and specificities of approximately 90% for the detection of coronary artery stenoses. Further improvements can be expected from new, intravascular contrast agents and from ultrafast sequences which permit acquisition of a sufficiently large imaging volume within one single breathold.

Coronary Angiography↗

Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography.

OBJECTIVES: The purpose of this study was to evaluate a contrast-enhanced three-dimensional (3D) breath-hold magnetic resonance (MR) technique for detection of coronary artery stenoses. BACKGROUND: The accuracy of previously published MR coronary angiography protocols varies widely. Recently, coronary artery imaging using T1-shortening contrast agent has become possible, but so far there are no data concerning its clinical application. METHODS: Magnetic resonance coronary angiography was performed in 50 patients with suspected coronary artery disease. Magnetic resonance data acquisition using an ultrafast 3D gradient-echo sequence lasted over 32 heartbeats within one single breath-hold. Twenty milliliters of gadopentetate dimeglumine was injected at a flow rate of 1 ml/s for two successive studies covering the main coronary arteries in single-oblique planes. Stenosis assessment by MR was compared with significant (diameter stenosis > 50%) stenoses on X-ray angiography. Evaluation was limited to the proximal and mid-coronary artery segments. RESULTS: Two hundred sixty-eight of 350 artery segments (76.6%) could be evaluated. Left circumflex coronary artery was only evaluable in 50% of cases by MR. In the evaluable segments, 48 of 56 stenoses and 193 of 212 nonstenotic segments were correctly classified by MR. On a patient basis, MR correctly identified 34 of 36 patients with and 8 of 14 patients without significant coronary stenoses as demonstrated by X-ray angiography (sensitivity 94.4%, specificity 57.1%). CONCLUSIONS: Oblique projection contrast-enhanced MR coronary angiograms obtained within one single breath-hold permit identification of patients with coronary stenoses in the proximal and mid segments of the major coronary arteries with satisfactory accuracy.

Adult↗

Prenatal diagnosis of QT prolongation by magnetocardiography.

Magnetocardiography constitutes a new tool for monitoring fetal cardiac activity. The fetal magnetocardiogram (FMCG) recorded noninvasively over the maternal abdomen is detectable with high temporal resolution and permits analysis of all parts of the PQRST waveform. In this way measurements of cardiac time intervals, including the QT interval, become possible. The following article constitutes the first report of antenatal detection of QT prolongation in two fetuses by FMCG.

Adult↗

Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction.

OBJECTIVE: To evaluate the accuracy of contrast enhanced electron beam computed tomography (EBCT) after acute myocardial infarction in determining patency of the infarct related artery and detecting high grade stenoses and occlusions in the coronary vessels. DESIGN: Case study using blinded comparison with invasive coronary angiography. PATIENTS: 36 patients (mean age 53 years) 4-70 days after acute myocardial infarction. INTERVENTIONS: The patients were studied by EBCT and invasive coronary angiography. For EBCT, 50 axial images of the heart (3 mm slice thickness) were acquired. They were triggered by the ECG during breath holding, after intravenous injection of contrast agent. The original images, surface reconstructions, and maximum intensity projections were evaluated for the presence of high grade stenoses and occlusions of the coronary arteries. MAIN OUTCOME MEASURES: EBCT results were compared with invasive coronary angiography. RESULTS: Of a total of 144 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 36 patients), 29 (20%) were unevaluable by EBCT. In the remaining arteries, 33 of 36 high grade lesions were correctly detected (92% sensitivity). Specificity was also 92% (73/79). Patency of the infarct related artery was correctly detected in 15 of 16 cases (94%). Five of the 14 occluded infarct related arteries (35%) were mistaken as stenotic but patent, and six could not be assessed. CONCLUSIONS: EBCT is very accurate in detecting significant coronary artery lesions in patients after acute myocardial infarction, but differentiation between occluded and patent infarct related arteries is currently unreliable.

Adult↗

In-plane coronary arterial motion velocity: measurement with electron-beam CT.

PURPOSE: To determine the speed of and changes in the speed of coronary arterial movement during the cardiac cycle with electron-beam computed tomography (CT). MATERIALS AND METHODS: With electron-beam CT, 20 consecutive cross-sectional images were acquired at the mid right coronary artery (with 50-msec acquisition time, 8-msec intersection delay, 7-mm section thickness, and intravenous administration of 40 mL of contrast agent) in 25 patients. On the basis of the displacement of the left anterior descending, left circumflex, and right coronary arterial cross sections from image to image, movement velocity in the transverse imaging plane was calculated and was correlated with the simultaneously recorded electrocardiogram. RESULTS: The velocity of in-plane coronary arterial motion varied considerably during the cardiac cycle. Peaks were caused by ventricular systole and diastole and by atrial contraction. The mean velocity was 46.6 mm/sec +/- 12. 5 (SD). The mean velocity of right coronary arterial movement (69.5 mm/sec +/- 22.5) was significantly faster than that of the left anterior descending (22.4 mm/sec +/- 4.1) or the left circumflex coronary artery (48.4 mm/sec +/- 15.0). The lowest mean velocity (27. 9 mm/sec) was at 48% of the cardiac cycle. CONCLUSION: The lowest velocity of coronary arterial movement, which displays considerable temporal variation, was at 48% of the cardiac cycle.

Aged↗