Noninvasive coronary angiography--an acceptable alternative?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S Achenbach.
Explore the source record for details and available documents.
BACKGROUND: Recent studies demonstrated an influence of atherosclerotic risk factors on the progression of aortic valve stenosis. The extent of aortic valve calcification (AVC) was also found to be a strong predictor of stenosis progression. We investigated the influence of the LDL cholesterol level (LDL), other standard cardiovascular risk factors, and the extent of coronary calcification (CC) on the progression of AVC quantified by electron beam tomography (EBT). METHODS AND RESULTS: In 104 patients (64.7+/-8 years, 89 male) with an EBT scan positive for AVC, CC and AVC were quantified using a volumetric score. EBT was repeated at a mean interval of 15 months (10 to 36 months), and the progression of AVC and CC was determined. Patients were divided into 2 groups according to LDL: group 1, LDL</=3.36 mmol/L (130 mg/dL), 57 patients; group 2, LDL>3.36 mmol/L (130 mg/dL), 47 patients. Mean values for CC were 546+/-932 mm(3) in scan 1 and 665+/-1085 mm(3) in scan 2 for AVC 324+/-796 mm(3) and 404+/-1076 mm(3), respectively. The mean progression of CC was 27+/-37% (group 1, 16+/-22%; group 2, 39+/-46%, P</=0.001) and of AVC was 25+/-38% (group 1, 9+/-22%; group 2, 43+/-44%, P</=0.001). CONCLUSIONS: Quantification of AVC by EBT permits new insights into the progression of aortic valve sclerosis. We observed a strong influence of LDL cholesterol level on the progression of AVC and CC, suggesting that lipid-lowering therapy may decrease the progression of aortic valve calcification.
BACKGROUND: The overall performance of available mechanical intravascular ultrasound catheters for fetal transesophageal echocardiography during fetoscopic fetal cardiac interventions in sheep has been limited by radioelectronic interference, low system frame rates, and low acoustic outputs. Therefore, a more reliable device is desired for human fetoscopic surgical procedures. METHODS AND RESULTS: We assessed the potential of a newly available 10-French phased-array intravascular ultrasound catheter for multimodal fetal transesophageal echocardiography in 5 fetal sheep between 78 and 98 days of gestation (term, 145 to 150 d). The intravascular ultrasound catheter was easily inserted through the mouth into the esophagus in all 5 sheep fetuses (mean weight, 600 g), and it permitted high-quality 2D imaging of the fetal heart in vertical imaging planes that were validated by MRI. Color Doppler and pulsed Doppler imaging permitted clear assessment of fetal cardiovascular flows and recording of velocity-time integral tracings of the fetal heart and great vessels. The vertical imaging planes were particularly useful to demonstrate interventional material inside the fetal heart and great vessels. CONCLUSIONS: Our early experience with the phased-array intravascular ultrasound catheter indicates that multimodal fetal transesophageal echocardiography has now become possible in these smallest of patients.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In recent years, several techniques for noninvasive imaging of the coronary artery lumen (noninvasive coronary angiography) have been developed. These techniques include magnetic resonance imaging, electron-beam computed tomography, and, most recently, multislice computed tomography. Each of these techniques has specific advantages and disadvantages. Currently, EBCT seems to permit the most robust coronary artery imaging. In the future, imaging modalities will have to be further improved and validated in order to define specific areas for potential clinical applications.
BACKGROUND: Multislice spiral computed tomography (MSCT) with retrospectively ECG-gated image reconstruction permits coronary artery visualization. We investigated the method's ability to identify high-grade coronary artery stenoses and occlusions. METHODS AND RESULTS: A total of 64 consecutive patients were studied by MSCT (4x1 mm cross-sections, 500-ms rotation, table feed 1.5 mm/rotation, intravenous contrast agent, retrospectively ECG-gated image reconstruction). All coronary arteries and side branches with a luminal diameter >/=2.0 mm were assessed concerning evaluability and the presence of high-grade stenoses (>70% diameter stenosis) or occlusions. Results were compared with quantitative coronary angiography. Of 256 coronary arteries (left main, left anterior descending, left circumflex and right coronary artery, including their respective side branches), 174 could be evaluated (68%). In 19 patients (30%), all arteries were evaluable. Artifacts caused by coronary motion were the most frequent reason for unevaluable arteries. Overall, 32 of 58 high-grade stenoses and occlusions were detected by MSCT (58%). In evaluable arteries, 32 of 35 lesions were detected, and the absence of stenosis was correctly identified in 117 of 139 arteries (sensitivity, 91%; specificity, 84%). If analysis was extended to all stenoses with >50% diameter reduction, sensitivity was 85% (40 of 47) and specificity was 76% (96 of 127). CONCLUSIONS: MSCT with retrospective ECG gating permits the detection of coronary artery stenoses with high accuracy if image quality is sufficient, but its clinical use may presently be limited due to degraded image quality in a substantial number of cases, mainly due to rapid coronary motion.
Anomalous coronary arteries are rare conditions. However, they may cause myocardial ischemia and sudden death and their reliable identification is crucial for any imaging method that attempts coronary artery visualization. We studied the ability of contrast-enhanced electron beam tomography (EBT) to identify anomalous coronary arteries and their course. Thirty patients with previously identified coronary anomalies and 30 subjects with normal coronary anatomy were studied. By EBT, 40 to 50 axial images of the heart (3-mm slice thickness, 1 mm overlap, electrocardiographic trigger) were acquired in a single breathhold during continuous injection of contrast agent (160 ml, 4 ml/s). Based on the original images and 3-dimensional reconstructions, the EBT data were analyzed by 2 blinded observers as to the presence of coronary anomalies and their course. Results were compared with invasive angiography. EBT correctly identified all normal controls and all patients with coronary anomalies. The anatomic course of the coronary anomalies was correctly classified in 29 of 30 patients (97%), including right-sided origin of the left main coronary artery (n = 4) or of the left circumflex coronary artery (n = 15), left-sided origin of the right coronary artery (n = 9), and 1 coronary fistula from the left circumflex coronary artery to the right atrium. Only the distal anastomosis of a second fistula from the left circumflex coronary artery to a bronchial artery was not correctly identified. This study demonstrates that contrast-enhanced EBT is a reliable noninvasive technique to identify anomalous coronary arteries and their course.
In 120 patients, the mean interscan variability of coronary calcium quantification by electron beam tomography was 19.9% (median 7.8%) for the traditional calcium score, and 16.2% (median 5.7%) for volumetric scoring. Although this difference was not significant, there was a significant influence of the total amount of calcium, number of acquired images, and image noise on interscan reproducibility.
BACKGROUND: The detection and quantification of coronary calcifications by electron beam tomography (EBT) permits to diagnose coronary atherosclerosis in an early stage. Initial reports indicate that multislice spiral CT (MSCT) also permits the quantification of coronary calcium, while equivalency to EBT has not been definitely proven. Since image acquisition, reconstruction and evaluation parameters influence the results of calcium quantification with CT techniques, standardization of the investigation is mandatory to make results comparable. AIM: The article summarizes guidelines for image acquisition and evaluation by EBT and describes guidelines and consensus reports that were issued concerning the clinical use of the method.
Explore the source record for details and available documents.
BACKGROUND: We investigated the applicability and image quality of contrast-enhanced coronary artery visualization by multislice spiral CT using retrospective ECG gating. METHODS AND RESULTS: Twenty-five patients in sinus rhythm (significant coronary artery stenoses ruled out by invasive angiography) were studied with a multislice spiral CT (Siemens SOMATOM Volume Zoom). In inspiration (mean breath-hold, 37 seconds), a volume data set of the heart was acquired (intravenous contrast agent; 4 x 1-mm slice thickness; 500-ms rotation; table feed, 1.5 mm/360 degrees ). Simultaneous recording of the ECG permitted retrospective reconstruction of contiguous cross sections in intervals of 1 mm at any desired interval of the cardiac cycle. The mean duration of the image reconstruction window was 185 ms. Next to 3-dimensional reconstructions of the heart and coronary arteries, multiplanar reconstructions were rendered to determine the visualized length of the coronary arteries, the contrast-to-noise ratio, and the correlation of coronary artery diameters to quantitative coronary angiography. CONCLUSIONS: The coronary arteries could be visualized over long segments (left main, 9+/-4 mm; left anterior descending, 112+/-34 mm; left circumflex, 80+/-29 mm; right coronary artery, 116+/-33 mm). On average, 78+/-16% of these distances were visualized free of motion artifacts. The mean contrast-to-noise ratio was 9.3+/-3.3. Coronary artery diameters in multislice spiral CT showed close correlation to quantitative coronary angiography (CT, 3.3+/-1.0 mm; angiography, 3. 2+/-0.9 mm; mean difference, 0.38 mm; r=0.86). Contrast-enhanced multislice spiral CT permits visualization of the coronary artery lumen. Further studies are necessary to determine whether image quality is sufficient to reliably detect coronary artery stenoses.
The biotin enzyme, 3-methylcrotonyl-CoA carboxylase (MCCase) (3-methylcrotonyl-CoA:carbon-dioxide ligase (ADP-forming), EC 6.4.1. 4), catalyzes a pivotal reaction required for both leucine catabolism and isoprenoid metabolism. MCCase is a heteromeric enzyme composed of biotin-containing (MCC-A) and non-biotin-containing (MCC-B) subunits. Although the sequence of the MCC-A subunit was previously determined, the primary structure of the MCC-B subunit is unknown. Based upon sequences of biotin enzymes that use substrates structurally related to 3-methylcrotonyl-CoA, we isolated the MCC-B cDNA and gene of Arabidopsis. Antibodies directed against the bacterially produced recombinant protein encoded by the MCC-B cDNA react solely with the MCC-B subunit of the purified MCCase and inhibit MCCase activity. The primary structure of the MCC-B subunit shows the highest similarity to carboxyltransferase domains of biotin enzymes that use methyl-branched thiol esters as substrate or products. The single copy MCC-B gene of Arabidopsis is interrupted by nine introns. MCC-A and MCC-B mRNAs accumulate in all cell types and organs, with the highest accumulation occurring in rapidly growing and metabolically active tissues. In addition, these two mRNAs accumulate coordinately in an approximately equal molar ratio, and they each account for between 0.01 and 0.1 mol % of cellular mRNA. The sequence of the Arabidopsis MCC-B gene has enabled the identification of animal paralogous MCC-B cDNAs and genes, which may have an impact on the molecular understanding of the lethal inherited metabolic disorder methylcrotonylglyciuria.
We have assessed the effect of 10:1 lossy (JPEG) compression on six board-certified radiologists' ability to detect three commonly seen abnormalities on chest radiographs. The study radiographs included 150 chest radiographs with one of four diagnoses: normal (n = 101), pulmonary nodule (n = 19), interstitial lung disease (n = 19), and pneumothorax (n = 11). Before compression, these images were printed on laser film and interpreted in a blinded fashion by six radiologists. Following an 8-week interval, the images were reinterpreted on an image display workstation after undergoing 10:1 lossy compression. The results for the compressed images were compared with those of the uncompressed images using receiver operating characteristic (ROC) analyses. For five of six readers, the diagnostic accuracy was higher for the uncompressed images than for the compressed images, but the difference was not significant (P > .1111). Combined readings for the uncompressed images were also more accurate when compared with the compressed images, but this difference was also not significant (P = .1430). The sensitivity, specificity, and accuracy values were 81.5%, 89.2%, and 86.7% for the compressed images, respectively, as compared with 78.9%, 94.5%, and 89.3% for the uncompressed images. There was no correlation between the readers' accuracy and their experience with soft-copy interpretation; the extent of radiographic interpretation experience had no correlation with overall interpretation accuracy. In conclusion, five of six radiologists had a higher diagnostic accuracy when interpreting uncompressed chest radiographs versus the same images modified by 10:1 lossy compression, but this difference was not statistically significant.
Selected patients with minor lower limb injuries and low risk for deep vein thrombosis (DVT), who required cast immobilizing and did not receive medical thrombosis prophylaxis, were included in a prospective study. The decision to give not medical thrombosis prophylaxis depended on an concept of individualised prophylaxis for patients at risk for thromboembolism. From March 1994 to March 1996 in 178 outpatients (118 men, 60 women, mean age 25.8 [16-39] years) a clinical examination and a colour-coded duplex sonography were performed after removal of the cast for detection of DVT of the lower limb. A phlebography was performed when thrombosis was suspected. Two patients developed a one bundle thrombosis of the calf. Clinical appearance of lung embolism was not observed. These results suggest, that low risk patients with minor injuries of the lower limb and plaster cast immobilisation do not need a medical thrombosis prophylaxis.
UNLABELLED: E-mail is an Internet service that can be used for sending messages and binary files between individuals as well as for participating in discussion groups. For sending and receiving these types of messages, the users must use either a dedicated e-mail client or one of the several mailing facilities of the World Wide Web. The news-groups enable like-minded people to discuss subjects on a group-wide basis, but access is generally not limited, and the participants cannot be selected. CONCLUSION: The objective of this paper is to give radiologists an introduction to using e-mail, mailing lists and news-groups, the three most important communication services of the Internet. The function of these services is explained, and the advantages of implementing them in a radiology practice are discussed. Potential problems and concerns including security matters are highlighted, and ways in which they can be resolved are suggested.
UNLABELLED: The Internet plays an important role in a growing number of medical applications. Finding relevant information is not always easy as the amount of available information on the Web is rising quickly. Even the best search engines can only collect links to a fraction of all existing Web pages. In addition, many of these indexed documents have been changed or deleted. The vast majority of information on the Web is not searchable with conventional methods. New search strategies, technologies and standards are combined in intelligent search agents (ISA) and robots, which can retrieve desired information in a specific approach. CONCLUSION: The article describes differences between ISAs and conventional search engines and how communication between agents improves their ability to find information. Examples of existing ISAs are given and the possible influences on the current and future work in radiology is discussed.