Search PubMed⌕ Search

Biomedical subjects

Rory A Cooper

Publications and source records attributed to Rory A Cooper.

At least 37 records · Page 2Linked to original sources

Virtual reality and computer-enhanced training applied to wheeled mobility: an overview of work in Pittsburgh.

Some aspects of assistive technology can be enhanced by the application of virtual reality. Although virtual simulation offers a range of new possibilities, learning to navigate in a virtual environment is not equivalent to learning to navigate in the real world. Therefore, virtual reality simulation is advocated as a useful preparation for assessment and training within the physical environment. We are engaged in several efforts to develop virtual environments and devices for mobility skills assessment and training, exercise training, and environment assessment. Virtual reality offers wheelchair users a training tool in different risk-free environments without any indoor (e.g., walls, furniture, and stairs) and outdoor (e.g., curb cuts, uneven terrain, and street traffic) physical constraints. Virtual reality technology will probably become more common in the field of assistive technology, especially given the rapid expansion of gaming technology and the continued exponential growth of computing power.

Computer Simulation↗

Upper limb strength in individuals with spinal cord injury who use manual wheelchairs.

INTRODUCTION: Manual wheelchair users have been found to be at risk for secondary upper extremity injuries. PURPOSE: The primary goal of this study was to compare shoulder strength and muscle imbalance of individuals with paraplegia to case-wise matched unimpaired controls (UC). A secondary goal was to evaluate the impact of age and neurologic level of injury (NLI) on weight-normalized strength (WNS). METHODS: The SCI group (n = 28) and the UC group (n = 28) completed bilateral shoulder isokinetic strength testing in the sagittal, frontal, and horizontal plane at 60 degrees/second using the BioDex system. Strength ratios, an indicator of muscle imbalance, were also calculated. RESULTS: No significant difference was seen in shoulder strength or strength ratios between the SCI group and the UC group. However, NLI was significantly related to WNS on several planes in the SCI group. Therefore, we dichotomized the SCI group into equal groups based on an NLI. The Low-SCI group was significantly stronger than the High-SCI group in most planes (P < 0.05). The High-SCI group was significantly weaker than the UC in extension (P < 0.01) and a trend (P < 0.01) was seen in flexion, abduction, and external rotation. The Low-SCI group was significantly stronger in abduction than the UC. CONCLUSION: WNS at the shoulder correlated with NLI. It is likely that this is related to contributions of the trunk and abdominal muscles during testing, since proximal trunk strength aids in generating forces distally. This study and others of strength in individuals with paraplegia may overestimate shoulder strength.

Adult↗

Biomechanics and strength of manual wheelchair users.

BACKGROUND/OBJECTIVE: Previous investigations have identified muscular imbalance in the shoulder as a source of pain and injury in manual wheelchair users. Our aim was to determine whether a correlation exists between strength and pushrim biomechanical variables including: tangential (motive) force (Ft), radial force (Fr), axial force (Fz), total (resultant) force (FR), fraction of effective force (FEF), and cadence. METHODS: Peak isokinetic shoulder strength (flexion [FLX], extension [EXT], abduction [ABD], adduction [ADD], internal rotation [IR], and external rotation [ER]) was tested in 22 manual wheelchair users with a BioDex system for 5 repetitions at 60 degrees/s. Subjects then propelled their own manual wheelchair at 2 speeds, 0.9 m/s (2 mph) and 1.8 m/s (4 mph), for 20 seconds, during which kinematic (OPTOTRAK) and kinetic (SMARTWHEEL) data were collected. Peak isokinetic forces in the cardinal planes were correlated with pushrim biomechanical variables. RESULTS: All peak torque strength variables correlated significantly (P < or = 0.05) with Ft, Fr, and FR, but were not significantly correlated with Fz, FEF, or cadence. Finally, there were no relationships found between muscle strength ratios (for example, FLX/EXT) and Ft, Fr, FR, Fz, or FEF. CONCLUSION: There was a correlation between strength and force imparted to the pushrim among wheelchair users; however, there was no correlation found in wheelchair propulsion or muscle imbalance. Clinicians should be aware of this, and approach strength training and training in wheelchair propulsion techniques separately.

Adult↗

Rehabilitation Medicine Summit: building research capacity.

The general objective of the "Rehabilitation Medicine Summit: Building Research Capacity" was to advance and promote research in medical rehabilitation by making recommendations to expand research capacity. The five elements of research capacity that guided the discussions were: 1) researchers; 2) research culture, environment, and infrastructure; 3) funding; 4) partnerships; and 5) metrics. The 100 participants included representatives of professional organizations, consumer groups, academic departments, researchers, governmental funding agencies, and the private sector. The small group discussions and plenary sessions generated an array of problems, possible solutions, and recommended actions. A post-Summit, multi-organizational initiative is called for to pursue the agendas outlined in this report.

Cooperative Behavior↗

Rehabilitation medicine summit: building research capacity.

The general objective of the "Rehabilitation Medicine Summit: Building Research Capacity" was to advance and promote research in medical rehabilitation by making recommendations to expand research capacity. The five elements of research capacity that guided the discussions were 1) researchers; 2) research culture, environment, and infrastructure; 3) funding; 4) partnerships; and 5) metrics. The 100 participants included representatives of professional organizations, consumer groups, academic departments, researchers, governmental funding agencies, and the private sector. The small group discussions and plenary sessions generated an array of problems, possible solutions, and recommended actions. A post-Summit, multi-organizational initiative is called to pursue the agendas outlined in this report.

Biomedical Research↗

Evaluation of selected electric-powered wheelchairs using the ANSI/RESNA standards.

OBJECTIVES: To compare the performance characteristics of different electric-powered wheelchairs (EPWs) and to evaluate the effectiveness of the American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America (ANSI/RESNA) wheelchair standards. DESIGN: Five types of EPWs were selected. Three wheelchairs of each type were tested according to the ANSI/RESNA wheelchair standards. SETTING: Rehabilitation engineering center. SPECIMENS: Fifteen wheelchairs. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Static tipping angle; dynamic tipping score; braking distance; energy consumption; static, impact, and fatigue strength; and climatic conditioning. RESULTS: There were significant differences (P<.05) among the 5 types of EPWs for static stability when facing both uphill and downhill in the most-stable and least-stable configurations. There were significant differences (P<.05) among the EPWs on most of the dynamic stability tests. There were also significant differences (P<.05) among EPWs for all the effectiveness of brakes conditions, as well as between 2 wheelchairs for the energy consumption testing. There were several failures among the wheelchairs during the static, impact, and fatigue strength testing and during the climatic testing. CONCLUSIONS: The results show that EPWs can vary greatly with respect to static and dynamic stability, braking distance, range, strength testing, and climatic conditioning. All these factors have a substantial effect on safety and performance.

Equipment Design↗

Manual wheelchair pushrim dynamics in people with multiple sclerosis.

OBJECTIVES: To define differences in pushrim dynamics during manual wheelchair propulsion by users with multiple sclerosis (MS) relative to 2 control groups of subjects with spinal cord injury (SCI) and no disability (ND) and to investigate changes in propulsion biomechanics at different speeds and with fatigue. DESIGN: Case-control. SETTING: Biomechanics laboratory. PARTICIPANTS: A convenience sample of 42 people, 8 women and 6 men per group. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The propulsion pattern, mean maximum speed, percentage of time in push and recovery phases, push angle, push frequency, mean maximum resultant pushrim force, mean work and push cycle, and hand-to-pushrim coupling and decoupling effects. RESULTS: The MS groups tended to use an arcing propulsion pattern more than did the control groups (Pmax=.003). The MS group pushed at a lower mean maximum velocity (v) when allowed to choose the speed of propulsion (v(MS),.67+/-.20m/s; v(SCI), 1.10+/-0.23m/s; P=.001), when asked to push at 1m/s (v(MS),.91+/-.26m/s; v(SCI), 1.12+/-0.11m/s; v(ND), 1.05+/-0.13m/s; P=.010), and were unable to maintain a self-selected speed during a 5-minute trial (Deltav(MS),.15+/-.02m/s; Deltav(ND),.03+/-.06m/s; P<.001). The MS group spent a higher proportion of time in the push phase of propulsion (Pmax=.001). In general, the MS group had smaller push angles, but push frequencies similar to the controls. Statistically adjusted MS group pushrim forces and work per push measures varied depending on context, but in all trials the MS group displayed a braking effect when grasping and releasing the pushrim. The MS group had declines in most measures when pushing at a self-selected speed for 5 minutes. In all trials, the MS group was more likely to display asymmetry between right and left sides in biomechanic parameters. CONCLUSIONS: Manual wheelchair users with MS have difficulty grasping and releasing the pushrim and maintaining speed during a fatigue trial. This likely leads to a slow self-selected speed of propulsion that may not be functional. Clinicians should remember these results when prescribing manual wheelchairs for people with MS.

Acceleration↗

Durability, value, and reliability of selected electric powered wheelchairs.

OBJECTIVE: To compare the durability, value, and reliability of selected electric powered wheelchairs (EPWs), purchased in 1998. DESIGN: Engineering standards tests of quality and performance. SETTING: A rehabilitation engineering center. SPECIMENS: Fifteen EPWs: 3 each of the Jazzy, Quickie, Lancer, Arrow, and Chairman models. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Wheelchairs were evaluated for durability (lifespan), value (durability, cost), and reliability (rate of repairs) using 2-drum and curb-drop machines in accordance with the standards of the American National Standards Institute and Rehabilitation Engineering and Assistive Technology Society of North America. RESULTS: The 5 brands differed significantly (P<or=.05) in durability, value, and reliability, except in terms of reliability of supplier repairs. The Arrow had the highest durability, value, and reliability in terms of the number of consumer failures, supplier failures, repairs, failures, consumer repairs and failures, and supplier repairs and failures. The Lancer had the poorest durability and reliability, and the Chairman had the lowest value. K0014 wheelchairs (Arrow, Permobil) were significantly more durable than K0011 wheelchairs (Jazzy, Quickie, Lancer). No significant differences in durability with respect to rear-wheel-drive (Arrow, Lancer, Quickie), mid-wheel-drive (Jazzy), or front-wheel-drive (Chairman) wheelchairs were found. CONCLUSIONS: The Arrow consistently outperformed the other wheelchairs in nearly every area studied, and K0014 wheelchairs were more durable than K0011 wheelchairs. These results can be used as an objective comparison guide for clinicians and consumers, as long as they are used in conjunction with other important selection criteria. Manufacturers can use these results as a guide for continued efforts to produce higher quality wheelchairs. Care should be taken when making comparisons, however, because the 5 brands had different features. Purchased in 1998, these models may be used for several more years. In addition, problem areas in these models may still be present in newer models.

Electricity↗

Relation between median and ulnar nerve function and wrist kinematics during wheelchair propulsion.

OBJECTIVE: To investigate the relation between median and ulnar nerve health and wrist kinematics in wheelchair users. DESIGN: Case series. SETTING: Biomechanics laboratory and electrodiagnostic laboratory at a Veterans Health Administration medical center and a university hospital, respectively. PARTICIPANTS: Thirty-five people with spinal cord injury who use manual wheelchairs. INTERVENTION: Subjects propelled their own wheelchair on a dynamometer at 0.9 and 1.8m/s. Bilateral biomechanic data were obtained by using force and moment sensing pushrims and a kinematic system. Bilateral median and ulnar nerve conduction studies were also completed. MAIN OUTCOME MEASURES: Wrist flexion, extension, radial and ulnar deviation peaks, and ranges of motion (ROMs) as related to median and ulnar motor and sensory amplitudes. A secondary analysis included peak pushrim forces and moments and stroke frequency. RESULTS: There was a significant, positive correlation between flexion and extension ROM and both ulnar motor amplitude (r=.383, P<.05) and median motor amplitude (r=.361, P<.05). CONCLUSIONS: Contrary to our hypothesis, subjects using a greater ROM showed better nerve function than subjects propelling with a smaller ROM. Subjects using a larger ROM used less force and fewer strokes to propel their wheelchairs at a given speed. It is possible that long, smooth strokes may benefit nerve health in manual wheelchair users.

Adolescent↗

Assessing the influence of wheelchair technology on perception of participation in spinal cord injury.

OBJECTIVE: To investigate factors related to the wheelchair, impairment, and environment that affect perception of participation of persons with spinal cord injury (SCI) in activities performed in 3 settings: in the home, in the community, and during transportation. DESIGN: Cross-sectional study. SETTING: Research centers and a specialized assistive technology (AT) clinic in Pittsburgh (Pitt). Research centers and community-based rehabilitation technology suppliers in Saint Louis (SL). PARTICIPANTS: Seventy wheelchair users with SCI. INTERVENTIONS: Subjects from Pitt and SL completed a written survey of AT usage in daily activities. MAIN OUTCOME MEASURES: Subjects were asked 5 questions within each setting (home, community, transportation) related to their perceived reason for functional limitations. RESULTS: The wheelchair was the most commonly cited factor limiting participation, followed by physical impairment and physical environment. Twenty-one percent of subjects with paraplegia reported pain as a limiting factor for their transportation use, significantly more (P=.047) than subjects with tetraplegia (3%). A trend (P=.099) was seen toward a higher percentage of subjects with tetraplegia (tetraplegia, 7%; paraplegia, 3%) reporting lack of equipment as a limiting factor for use of transportation. Differences were also seen across sites. CONCLUSIONS: The wheelchair was the most commonly cited limiting factor, followed by physical impairment and physical environment. The wheelchair is the most important mobility device used by persons with SCI and the one that users most associate with barriers.

Activities of Daily Living↗

Impact of a pushrim-activated power-assisted wheelchair on the metabolic demands, stroke frequency, and range of motion among subjects with tetraplegia.

OBJECTIVES: To determine differences in metabolic demands, stroke frequency, and upper-extremity joint range of motion (ROM) during pushrim-activated power-assisted wheelchair (PAPAW) propulsion and traditional manual wheelchair propulsion among subjects with tetraplegia. DESIGN: Repeated measures. SETTING: A biomechanics laboratory within a Veterans Affairs medical center. PARTICIPANTS: Fifteen full-time manual wheelchair users who had sustained cervical-level spinal cord injuries. INTERVENTIONS: Participants propelled both their own manual wheelchairs and a PAPAW through 3 different resistances (slight, 10W; moderate, 12W; high, 14W) on a wheelchair dynamometer. Each propulsion trial was 3 minutes long. MAIN OUTCOME MEASURES: Primary variables that were compared between the 2 wheelchairs were participants mean steady-state oxygen consumption, ventilation, heart rate, mean stroke frequency, and maximum upper-extremity joint ROM. RESULTS: When using the PAPAW, participants showed a significant ( P <.05) decrease in mean oxygen consumption and ventilation throughout all trials. Mean heart rate was significantly lower when using the PAPAW for the high resistance trial. Stroke frequency was significantly lower when using the PAPAW for the slight and moderate resistances. Overall joint ROM was significantly lower when using the PAPAW. CONCLUSIONS: For subjects with tetraplegia, PAPAWs reduce the energy demands, stroke frequency, and overall joint ROM when compared with traditional manual wheelchair propulsion.

Adult↗

Demographic and socioeconomic factors associated with disparity in wheelchair customizability among people with traumatic spinal cord injury.

OBJECTIVES: To determine if a standard of care for wheelchair provision exists within the participating centers and if there is disparity in wheelchair customizability among the study sample. DESIGN: Convenience sample survey. SETTING: Thirteen Model Spinal Cord Injury Systems that provide comprehensive rehabilitation for people with traumatic spinal cord injury (SCI) and that are part of the national database funded through the US Department of Education. PARTICIPANTS: A total of 412 people with SCI who use wheelchairs over 40 hours a week. INTERVENTION: Survey information was obtained from subjects via telephone and in-person interviews and from the national database. Collected information included age, race, education, level of injury, and wheelchair funding source. MAIN OUTCOME MEASURES: Number and type (manual or power) of wheelchairs. Wheelchair customizability as defined by design features (eg, adjustable axle position, programmable controls). RESULTS: Ninety-seven percent of manual wheelchair users and 54% of power wheelchair users had customizable wheelchairs. No power wheelchair user received a wheelchair without programmable controls. Minorities with low socioeconomic backgrounds (low income, Medicaid/Medicare recipients, less educated) were more likely to have standard manual and standard programmable power wheelchairs. Older subjects were also more likely to have standard programmable power wheelchairs. CONCLUSIONS: The standard of care for manual wheelchair users with SCI is a lightweight and customizable wheelchair. The standard of care for power wheelchairs users has programmable controls. Unfortunately, socioeconomically disadvantaged people were less likely to receive customizable wheelchairs.

Activities of Daily Living↗

The GAME(Cycle) exercise system: comparison with standard ergometry.

BACKGROUND: It is well established that physical activity is beneficial to health. For the individual in a wheelchair, a regular exercise program might not be available or may be too difficult to participate in physically and/or psychologically. Many exercise devices and regimes are boring. The goal, therefore, is to develop a device that makes exercise more exciting and, thus, motivates a person to exercise more or for a longer period of time, yielding increased energy expenditure. Our laboratory developed an interface between an arm ergometer and a computer game that allows the user to control game play on the screen as if using a joystick. The purpose of this study was to determine (a) whether the GAME(Cycle) system would elicit an exercise effect similar to arm ergometry, (b) whether perceived exertion would be different between the 2 devices, and (c) individuals' impressions regarding the GAME(Cycle) system. METHODS: Thirteen individuals who used wheelchairs participated in the study. Participants were asked to exercise for 2 separate, 19-minute sessions. For 1 session, a GAME(Cycle) system was used and for the other session, the same arm ergometer was used, but without the computer game being played. Physiologic data and perceived exertion were collected for each session. RESULTS: There were significant differences between playing the game and not playing the game for VO2 (P = 0.03) and VCO2 (P = 0.02), with higher values being found when the game was played. Perceived exertion was not significantly different between the 2 trials. CONCLUSION: GAME(Cycle) appears to be similar in nature with respect to energy expenditure to arm ergometry. Because this study was conducted on athletes, further research is needed with sedentary individuals to determine exercise effects and perceived exertion.

Adult↗

Evaluation of selected sidewalk pavement surfaces for vibration experienced by users of manual and powered wheelchairs.

BACKGROUND: Obstacles such as bumps, curb descents, and uneven driving surfaces cause vibrations that affect the wheelchair, and in turn, the wheelchair user. Chronic exposure can cause low-back pain, disk degeneration, and other harmful effects. Little research has been conducted to assess the vibrations experienced by wheelchair users. OBJECTIVE: The purpose of this study was to conduct an evaluation of the vibration exposure during electric-powered wheelchair driving and mechanical energy requirements for manual wheelchair propulsion over selected sidewalk surfaces. The goal was to determine the criteria for a wheelchair-pedestrian access route that does not require excessive propulsive work or expose wheelchair users to potentially harmful vibrations. METHODS: Ten unimpaired individuals participated in this study. Six sidewalk surfaces were tested. Measured variables included power of the acceleration per octave, mechanical work to propel over surfaces, peak acceleration, and frequency at which peak acceleration occurs. RESULTS: For both the manual and electric-powered wheelchair, at 1 m/s, significant differences were found in peak accelerations between the seat and footrest (P < 0.0001) and between the sidewalk surfaces (P = 0.004). The greatest risk for injury caused by shock and vibration exposure occurs at frequencies near the natural frequency of seated humans (4-15 Hz). The values for work required to propel over the surfaces tested were not statistically significantly different. Besides appearance and construction, the only distinguishing characteristic was surface roughness caused by the joints. CONCLUSION: When treating the poured concrete sidewalk as the standard, surfaces 2, 3, 5, and 6 compared most favorably in terms of vibration exposure, whereas surface 4 produced mixed results. Surfaces 2, 3, 5, and 6 yielded results that were similar to the poured concrete sidewalk and could be considered acceptable for wheelchair users. In conclusion, surfaces other than the traditional poured concrete can be used for pedestrian access routes without adding vibration exposure or reducing propulsion efficiency.

Adult↗

Bioengineering and spinal cord injury: a perspective on the state of the science.

There is little doubt that as technologic advances become available, people with spinal cord injuries (SCIs) are living healthier, more productive, and longer lives. Federally and privately funded research, foreign competition, and globalization appear to be factors that will drive bioengineering advances within the assistive technology (AT) industry. The seeds of bioengineering research are likely to contribute to improvements in universal design and the mainstreaming of products. The aims of AT have changed tremendously in the past 50 years. Most of the federal agencies supporting assistive and rehabilitative technology research and development did not exist 50 years ago. Indeed, the leading AT companies all were established within the past 50 years. Bioengineering has the potential to be to the 21 st century what electronic engineering was to the 20th century. Advances in power electronics, telecommunications, controls, sensors, and instrumentation have really only just begun to be applied for devices to assist people with SCI. Advancing technology for people with SCI represents a significant career and business opportunity for engineers who want to serve the public good in a meaningful and tangible way.

Biomedical Engineering↗

Development of a consumer-driven Wheelchair Seating Discomfort Assessment Tool (WcS-DAT).

This study examined the concept of seating discomfort in a population of full-time wheelchair users with intact sensation. The goal was to construct a tool that would quantify seating discomfort experienced by wheelchair users. Ten participants were interviewed using ethnographic interview techniques. Data were analyzed using a cross-classifying matrix to examine commonalities among the 10 participants' responses. There were 16 discomfort and 13 comfort descriptors used by the participants. Of these, eight discomfort and five comfort descriptors were selected to include in the Wheelchair Seating Discomfort Assessment Tool (WcS-DAT). The discomfort descriptors selected were: aches and pains, need to move, pressure points, feeling poorly positioned, unable to concentrate, instability, not comfortable, and feeling too hot, cold or damp. The comfort descriptors selected were: absence of discomfort, feeling good, having no pain, able to concentrate, and feeling stable. The WcS-DAT also includes general information, such as the amount of time spent sitting and whether the individual was transferred into the chair properly--factors thought to affect discomfort--and ratings of discomfort intensity--in general and differentiated by body area. The WcS-DAT is a comprehensive tool for quantification of wheelchair seat discomfort for this population.

Adult↗

Push for power.

Explore the source record for details and available documents.

Electric Power Supplies↗

Preliminary assessment of a prototype advanced mobility device in the work environment of veterans with spinal cord injury.

The INDEPENDENCE 3000 IBOT Transporter (IBOT) is an electronically stabilizing device for people with disabilities. The purpose of this study was to collect qualitative data on the potential for the IBOT to improve employment satisfaction of veterans who use wheelchairs to work. This study was based upon observations by trained clinicians, and responses to a survey completed by four men with traumatic spinal cord injury, who worked in an office environment. The mean age of the subjects was 52 +/- 8.8 years. The subjects used the devices to hold eye-level discussions with colleagues, climb stairs, ascend steep ramps, and negotiate curbs. When subjects were asked to rate the ease of getting around in the IBOT compared to their personal wheelchairs, they responded with a mean of 6.7 +/- 1.8 on a 10-point visual analog scale. The response to rating the overall function of the IBOT within their working environment yielded a rating of 6.0 +/- 2.8. Half of the users felt that the IBOT would help them at work and all thought it should be made available to veterans who use wheelchairs. A larger study should be conducted to determine if the IBOT affects work performance and the ability to return to work.

Employment↗