Search PubMed⌕ Search

Biomedical subjects

Roberto Passariello

Publications and source records attributed to Roberto Passariello.

At least 37 records · Page 2Linked to original sources

Small bowel.

MR imaging, using modern equipment and a rigorous technical approach, can offer detailed morphologic information and functional data on the small bowel. The optimal study technique is debatable, although the oral administration of contrast material as a first-line approach is less expensive, faster, easier to perform, and better tolerated by patients. MR enteroclysis might be reserved for selected cases as a second-line study. The major clinical indication is the evaluation of patients who have suspected or known Crohn's disease. The absence of ionizing radiation, considering the young age of most of the patients and the frequency of the examinations, is an important advantage over other techniques (radiograph and CT enteroclysis).

Contrast Media↗

Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging.

OBJECTIVES: The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer. MATERIALS AND METHODS: Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings. RESULTS: At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85). CONCLUSIONS: The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.

Adult↗

Hepatocellular carcinoma: role of unenhanced and delayed phase multi-detector row helical CT in patients with cirrhosis.

PURPOSE: To determine, by using multi-detector row helical computed tomography (CT), the added value of obtaining unenhanced and delayed phase scans in addition to biphasic (hepatic arterial and portal venous phases) scans in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS: Local ethical committee approval and patient consent were obtained. One hundred ninety-five patients (129 men, 66 women; mean age, 61 years; age range, 39-78 years) with 250 HCCs underwent multi-detector row helical CT of the liver. A quadruple-phase protocol that included unenhanced, hepatic arterial, portal venous, and delayed phases was performed. Analysis of images from hepatic arterial and portal venous phases combined, hepatic arterial and portal venous phases with the unenhanced phase, hepatic arterial and portal venous phases with the delayed phase, and all phases combined was performed separately by three independent radiologists. Relative sensitivity, positive predictive value, and area under the receiver operating characteristic curve (A(z)) were calculated for each reading session. RESULTS: Mean sensitivity and positive predictive values, respectively, for HCC detection were 88.8% (666 of 750 readings) and 97.8% (666 of 681 readings) for the combined hepatic arterial and portal venous phases, 89.2% (669 of 750 readings) and 97.8% (669 of 684 readings) for hepatic arterial and portal venous phases with the unenhanced phase, 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for hepatic arterial and portal venous phases with the delayed phase, and 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for all four phases combined. The reading sessions in which delayed phase images were available for interpretation showed significantly (P < .05) superior sensitivity and A(z) values. CONCLUSION: Unenhanced phase images are not effective for HCC detection. Because of the significant increase in HCC detection, a delayed phase can be a useful adjunct to biphasic CT in patients at risk for developing HCC.

Adult↗

Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies.

PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multi-detector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis. RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%. CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.

Aged↗

Contrast-enhanced sonography with SonoVue: enhancement patterns of benign focal liver lesions and correlation with dynamic gadobenate dimeglumine-enhanced MRI.

OBJECTIVE: Contrast-enhanced real-time low-mechanical-index sonography is a new diagnostic technique for the assessment of macro- and microcirculation. The purpose of our article is to describe contrast-enhancement patterns of different benign focal liver lesions using the second-generation contrast agent SonoVue and to compare these findings with those of gadobenate dimeglumine-enhanced MRI. CONCLUSION: SonoVue-enhanced real-time low-mechanical-index sonography provides specific contrast-enhancement patterns of different benign focal liver lesions, allowing accurate characterization. Findings on SonoVue-enhanced sonography correlate well with those obtained on gadobenate dimeglumine-enhanced MRI.

Adult↗

Polytetrafluoroethylene-covered nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation: 3-year experience.

PURPOSE: To prospectively evaluate the use of a recently developed expanded polytetrafluoroethylene (PTFE)-covered nitinol stent-graft in preventing the need for repeated intervention after transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: Fifty-three consecutive patients underwent TIPS procedures between January 2000 and February 2002. Minimum patient follow-up was 9 months (mean, 16.3 months). Fifty-six stent-grafts were implanted in 53 patients; eight of the devices were 8 mm in diameter and 48 were 10 mm in diameter. The stent length varied from 4 to 7 cm. Indications for the procedure included recurrence of bleeding after sclerotherapy (28 patients with cirrhosis, one patient without), refractory ascites or hydrothorax (21 patients with cirrhosis, one patient without), and Budd-Chiari syndrome (two patients). RESULTS: A technical success rate of 100% was obtained, with an early clinical success rate of 96.2%. During the follow-up period, the recurrence rate was 3.4% (one of 29 patients) for bleeding and 9.0% (two of 22 patients) for ascites. Shunt malfunction occurred in nine of 53 patients (16.9%); in one of these nine patients, shunt occlusion was evident after revision, and a parallel shunt was created. The 1-year primary and secondary patency rates were 83.8% and 98.1%, respectively. In this series, the incidence of encephalopathy (included even as a single short-lived episode) was 47.1% (25 of 53 patients). The 30-day mortality rate was 3.8% (two of 53), and the late mortality rate was 17.3% (eight of 46), excluding seven patients who underwent transplantation. CONCLUSION: The new PTFE-covered nitinol stent-graft used appears to be excellent in preventing the need for repeated interventions. A primary patency rate of 83.8% and a secondary patency rate of 98.1% were achieved.

Adolescent↗

MR appearances of radiofrequency thermal ablation region: histopathologic correlation with dog liver models and an autopsy case.

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the utility of magnetic resonance (MR) imaging for indicating the extent of true tissue necrosis of the liver after radiofrequency (RF) ablation in comparison with histopathologic findings in dog models and an autopsy case. MATERIALS AND METHODS: RF ablation of the liver parenchyma was performed on three dogs under general anesthesia. MR appearances of the RF-ablated regions on T1-weighted fast-low angle shot (FLASH; repetition time/echo time [TR/TE]/flip angle: 120/3.8/70),T2-weighted turbo spin echo (3000/80/echo train = 25) and contrast-enhanced T1-weighted images were compared with histopathologic findings. An autopsy case with hepatocellular carcinoma was also enrolled in this study. RESULTS: All ablated regions showed three zones on T1-weighted FLASH images: a central zone with low intensity, a broad hyperintense middle zone, and a surrounding hypointense band. The central and middle zones corresponded to the degrees of coagulation necrosis observed during histopathologic examination, whereas no viable cells were seen in these zones during the microscopic examination using nicotinamide adenine dinucleotide diaphorase stain. The surrounding hypointense band corresponded to sinusoidal congestion in the acute phase and to fibrotic change in the subacute phase. CONCLUSION: MR imaging using the FLASH sequence can accurately determine the extent of the necrotic area after RF ablation.

Aged↗

Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps.

BACKGROUND AND AIMS: We prospectively compared the performance of low-dose multidetector computed tomographic colonography (CTC) without cathartic preparation with that of colonoscopy for the detection of colorectal polyps. METHODS: A total of 203 patients underwent low-dose CTC without cathartic preparation followed by colonoscopy. Before CTC, fecal tagging was achieved by adding diatrizoate meglumine and diatrizoate sodium to regular meals. No subtraction of tagged feces was performed. Colonoscopy was performed 3-7 days after CTC. Three readers interpreted the CTC examinations separately and independently using a primary 2-dimensional approach using multiplanar reconstructions and 3-dimensional images for further characterization. Colonoscopy with segmental unblinding was used as reference standard. The sensitivity of CTC was calculated both on a per-polyp and a per-patient basis. For the latter, specificity, positive predictive values, and negative predictive values were also calculated. RESULTS: CTC had an average sensitivity of 95.5% (95% confidence interval [CI], 92.1%-99%) for the identification of colorectal polyps > or =8 mm. With regard to per-patient analysis, CTC yielded an average sensitivity of 89.9% (95% CI, 86%-93.7%), an average specificity of 92.2% (95% CI, 89.5%-94.9%), an average positive predictive value of 88% (95% CI, 83.3%-91.5%), and an average negative predictive value of 93.5% (95% CI, 90.9%-96%). Interobserver agreement was high on a per-polyp basis (kappa statistic range, .61-.74) and high to excellent on a per-patient basis (kappa statistic range, .79-.91). CONCLUSIONS: Low-dose multidetector CTC without cathartic preparation compares favorably with colonoscopy for the detection of colorectal polyps.

Adult↗

Decrease of signal intensity of myometrium and cervical stroma after ultrasmall superparamagnetic iron oxide (USPIO) particles administration: an MR finding with potential benefits in T staging of uterine neoplasms.

OBJECTIVES: Following the empiric observation of a significant decrease of signal intensity of both myometrium and cervical stroma on ultrasmall superparamagnetic iron oxide (USPIO)-enhanced images, the aim of our study was to evaluate whether USPIO-enhanced T2*-weighted gradient echo (GRE) images might provide any potential advantage on T-staging of uterine malignancies having surgery and histology as standard of reference MATERIALS AND METHODS: Seventeen female patients with known uterine malignancies underwent magnetic resonance (MR) imaging before and 24 hours after the intravenous administration of the USPIO agent. Imaging protocol included proton density-weighted turbo spin echo and T2*-weighted GRE sequences. Each patient underwent surgery within 14 days from the first MR examination, and histologic confirmation of tumor T-stage was obtained. Quantitative (calculation of signal-to-noise and contrast-to-noise ratios) and qualitative (visual assessment of T staging) analyses were performed on unenhanced and USPIO-enhanced images. RESULTS: Quantitative analysis showed a significantly lower (P < 0.05) signal-to-noise ratio of myometrium and cervical stroma on USPIO-enhanced compared with unenhanced images. In 15 of 17 patients (88.2%), the contrast-to-noise ratio between tumor and myometrium and between tumor and cervical stroma was higher on USPIO-enhanced compared with unenhanced images (P < 0.001). Qualitative analysis demonstrated that the GRE T2* USPIO-enhanced MR offers a better definition of the depth of tumor infiltration rather than the unenhanced GRE T2* images. CONCLUSION: The decrease of signal intensity of myometrium and cervical stroma on T2*-weighted GRE images after the intravenous administration of USPIO should be considered a constant and physiologic finding that improves tumor conspicuity in the majority of the cases, allowing more accurate T-staging of neoplastic lesions.

Adult↗

Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography.

PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.

Adult↗

Laparoscopic splenectomy: multi-detector row CT for preoperative evaluation.

PURPOSE: To prospectively evaluate multi-detector row spiral computed tomography (CT) for determination of splenic volume, splenic vascular anatomy, and presence of accessory spleens and parenchymal lesions in patients who were undergoing laparoscopic splenectomy. MATERIALS AND METHODS: Twenty-two patients who were candidates for laparoscopic splenectomy underwent multiphasic multi-detector row CT. Two observers evaluated splenic volume with two hand-tracing editing modalities. Variability between the two observers was calculated with a reliability coefficient (Cronbach alpha). A linear regression equation for each modality was generated to identify the correlation between the two observers. Multi-detector row CT angiography was evaluated for assessment of splenic vascular anatomy. Presence and number of both accessory spleens and parenchymal lesions were recorded. RESULTS: Mean splenic volume was 1,050 and 1,046 mL, respectively, for observers A and B by using each-section editing (technique 1) and 1,067 and 1,068 mL for observers A and B by using distanced editing (technique 2). For each editing modality, alpha reliability coefficient was higher than 0.99. Both techniques 1 and 2 were very highly predictive of specimen weight and had R2 values of greater than 0.99 (P <.001). CT angiograms correctly showed polar arteries in all cases and the presence of the arteria pancreatica magna in one case. Multi-detector row CT demonstrated the presence, number, and size of all accessory spleens and of focal parenchymal lesions. CONCLUSION: Multi-detector row CT volumetric and anatomic evaluation provided accurate and reproducible information.

Adult↗

Color Doppler ultrasound in renal transplant: role of resistive index versus renal cortical ratio in the evaluation of renal transplant diseases.

BACKGROUND/AIMS: Ultrasound (US) and color Doppler are not sensitive enough to detect anomalies in cortical perfusion, which is affected in most graft dysfunctions. The renal cortical ratio (RCR) is a variation in the resistive index (RI) values from the renal artery to cortical vessels, expressed in percent. The aim of this study was to compare the RI and RCR in the differentiation of normal and pathological grafts, to assess the positive predictive value of RCR and show that RCR enables earlier diagnosis than RI. METHODS: Based on clinical, biochemical and histological examinations, 494 renal allografts were divided into 3 groups (normal grafts, acute and chronic pathologies). All patients underwent US color Doppler. RI was measured and RCR calculated. Follow-up confirmed the initial division in groups. Statistical significance was calculated using the two-tailed Student's t test. The positive predictive value was calculated for each group. RESULTS: 24 h after transplant, RCR differentiated normal grafts from acute dysfunctions despite confusing biochemical values and clinical symptoms. In chronic patients, RCR variations occurred later but always before the serum creatinine level increased. CONCLUSION: RCR presented a higher positive predictive value than RI. RCR curves were already altered in the early stages of transplant pathologies. RCR calculation is easy and makes a significant contribution towards a correct early diagnosis.

Adolescent↗

Stent repair of bilateral post-traumatic dissections of the internal carotid artery.

PURPOSE: To report endovascular repair of bilateral internal carotid arteries (ICAs) in a youth following an accident. CASE REPORT: A 17-year-old boy presented with dissection of both ICAs after a motorcycle accident. The lesions started 2 cm above the bifurcation and continued upward to the siphon, with normal flow into the circle of Willis. Surgical repair was excluded due to the critical clinical condition of the patient and owing to the anatomical extent of the dissection. Carotid Wallstent endoprostheses were deployed bilaterally to repair the dissected segments of the ICAs. After 13 months, the patient is in good health, with complete patency of both arteries. CONCLUSIONS: The good result we experienced in this case indicates that stents may be a safe and effective treatment for traumatic bilateral carotid dissections. However, the long-term durability of these devices in a young patient remains to be determined.

Adolescent↗