Search PubMed⌕ Search

Biomedical subjects

Roberto Passariello

Publications and source records attributed to Roberto Passariello.

At least 19 recordsLinked to original sources

Initial experience with magnetic resonance fluoroscopy in the evaluation of oesophageal motility disorders. Comparison with manometry and barium fluoroscopy.

The aim of this paper was to assess the diagnostic value of magnetic resonance (MR) fluoroscopy in the study of oesophageal motility disorders and to compare MR fluoroscopy results with those of manometry and barium contrast radiography. Twenty-five subjects referred for dysphagia and three patients in follow-up after pneumatic dilatation of the lower oesophageal sphincter to treat severe achalasia underwent esophageal manometry, barium contrast radiography and MR fluoroscopy. Examinations were performed on a 1.5 T scanner. Dynamic turbo- fast low angle shot (turbo-FLASH) sequences acquired during oral contrast agent administration were used to perform MR fluoroscopy. MR fluoroscopy correctly diagnosed achalasia in nine patients, uncoordination of esophageal body motility in ten and scleroderma oesophagus in one. Diagnostic performance was satisfactory, with a sensitivity of 87.5% and a specificity of 100% in the general depiction of motility alterations. Our work demonstrates that MR fluoroscopic examination in subject affected by oesophageal motility disorders is feasible and can properly depict motility and morphology alterations, achieving correct diagnosis in the majority of cases. Studies on larger populations are necessary to obtain statistically significant results.

Adult↗

Hepatic metastases: detection with multi-detector row CT, SPIO-enhanced MR imaging, and both techniques combined.

PURPOSE: To retrospectively compare the accuracy in detection of hepatic metastases among contrast material-enhanced multi-detector row computed tomography (CT) alone, superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging alone, and a combination of contrast-enhanced CT and SPIO-enhanced MR imaging. MATERIALS AND METHODS: The ethics committee did not require its approval or informed consent for this retrospective study, which was compliant with Declaration of Helsinki principles. Data in 38 patients (22 men, 16 women; mean age, 64.5 years; range, 35-78 years) suspected of having hepatic metastases who underwent both contrast-enhanced CT and SPIO-enhanced MR imaging were retrospectively analyzed. Twenty-one of the 38 patients had 61 metastases. Seventeen of the 61 metastases were confirmed histologically; the remaining 44 metastases were defined with imaging follow-up. At MR imaging, SPIO-enhanced heavily T1-weighted images, T2*-weighted gradient echo images, and T2-weighted fast spin-echo images were evaluated. Contrast-enhanced multi-detector row CT images obtained in the portal phase were evaluated. Four blinded observers independently reviewed CT images, MR images, and the combination of CT and MR images. Diagnostic accuracy was evaluated by using the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values were also analyzed with the Fisher protected least significant difference test and generalized estimating equations. RESULTS: The mean area under the AFROC curve for the combined approach (0.70) was significantly higher than that for SPIO-enhanced MR imaging alone (0.58, P < .05, Fisher protected least significant difference test), and there was no significant difference between each of them and that for contrast-enhanced CT alone (0.66). For all lesions, the mean sensitivity of combined imaging (0.59) was significantly higher than that of CT (0.48) or MR imaging (0.43) alone (P < .05, Fisher protected least significant difference test and generalized estimating equations). For all lesions, the mean positive predictive values were 0.82, 0.89, and 0.81, for combined MR and CT, CT alone, and MR alone, respectively. CONCLUSION: The addition of SPIO-enhanced MR imaging to contrast-enhanced multi-detector row CT (ie, combined analysis of SPIO-enhanced MR images and contrast-enhanced CT images) can improve sensitivity in the detection of hepatic metastases, although this improvement in sensitivity was not significant at AFROC analysis.

Adult↗

Fat in the liver: diagnosis and characterization.

The purpose of this article is to provide an update on imaging techniques useful for detection and characterization of fat in the liver. Imaging findings of liver steatosis, both diffuse steatosis and focal fatty change, as well as focal fatty sparing, are presented. In addition, we will review computed tomography (CT) and magnetic resonance (MR) findings of focal liver lesions with fatty metamorphosis, including hepatocellular carcinoma, hepatocellular adenoma, focal nodular hyperplasia, angiomyolipoma, lipoma, and metastases.

Diagnosis, Differential↗

Hemodynamic characterization of focal hepatic lesions: role of ferucarbotran-enhanced dynamic MR imaging using T2-weighted multishot spin-echo echo-planar sequence.

PURPOSE: To investigate the role of ferucarbotran-enhanced dynamic MR imaging using multishot spin-echo echo-planar sequence in the evaluation of hemodynamics of focal hepatic lesions. MATERIALS AND METHODS: Sixty-three focal hepatic lesions (24 benign and 39 malignant) from 53 consecutive patients who underwent both ferucarbotran-enhanced MR imaging and dynamic computed tomography (CT) were included in this study. MR imaging was performed with a 1.5-T scanner with a phased-array coil. T2-weighted multishot spin-echo echo-planar sequences (TR/TE = 1714-2813/80 msec) were obtained during a single breathhold before and 15, 60, 120, 180, and 600 seconds after intravenous injection of ferucarbotran. The enhancement patterns of lesions were classified into three categories by a study coordinator on the basis of dynamic CT images as hypervascular, hypovascular, and hemangioma type. The study coordinator created mean contrast-to-noise ratio of lesions vs. time curves for each enhancement pattern for quantitative analyses. Moreover, three radiologists separately and blindly reviewed MR images, and then assigned three confidence scores for the three enhancement patterns to each lesion. Sensitivity, specificity, and receiver operating characteristic analyses were performed. RESULTS: Quantitative analyses showed characteristic enhancement curves for each enhancement pattern. Mean sensitivities/specificities were 0.816/0.882, 0.897/0.863, and 0.800/0.989 for hypervascular, hypovascular, and hemangioma types, respectively. Mean areas under the receiver operating characteristic curve were 0.886 for hypervascular type and 0.913 for hypovascular type. CONCLUSION: Ferucarbotran-enhanced dynamic MR imaging can be used to successfully characterize the hemodynamics of focal hepatic lesions.

Adult↗

Assessment of two 3D MDCT colonography protocols for observation of colorectal polyps.

OBJECTIVE: The objective of our study was to assess the value of two-way interpretation (i.e., from rectum to cecum and vice versa) compared with one-way interpretation (i.e., from rectum to cecum only) in terms of polyp detection and interpretation time on MDCT colonography. MATERIALS AND METHODS: Fifty consecutive patients underwent both CT colonography and conventional colonoscopy. Three radiologists independently analyzed the CT colonographic examinations of each patient using a primary 3D method. All examinations were analyzed using two techniques: navigation from rectum to cecum only (one-way) and navigation from rectum to cecum and vice versa (two-way). Sensitivity and positive predictive value were calculated on both a per-polyp basis and a per-patient basis. Alternative free-response receiver operating characteristic (ROC) curve analysis was estimated, and image interpretation time was documented. RESULTS: One hundred fifty-five polyps were depicted in 45 patients by colonoscopy. The mean sensitivity of CT colonography for polyp detection with two-way (88.4%) was significantly superior to that with one-way (78.1%) (p < 0.01). The mean positive predictive value of each observer with one-way was 66.7%, whereas that with two-way was 65.8%. The mean area under the alternative free-response ROC curve (A(z) value) with two-way (0.827) was higher than that with one-way (0.816), but there was not a statistically significant difference. The average interpretation time of each observer with two-way (39 min) was statistically significantly longer than that with one-way (25 min) (p < 0.01). CONCLUSION: When using a primary 3D interpretation technique at CT colonography, complete 3D navigation from rectum to cecum and from cecum to rectum is mandatory to maximize polyp detection. The image interpretation time for two-way interpretation is statistically significantly longer than that with one-way interpretation.

Adult↗

Breast lesion detection and characterization at contrast-enhanced MR mammography: gadobenate dimeglumine versus gadopentetate dimeglumine.

PURPOSE: To prospectively and intraindividually compare equivalent (0.1 mmol per kilogram of body weight) doses of gadobenate dimeglumine and gadopentetate dimeglumine for accuracy of detection and characterization of breast lesions at contrast material-enhanced magnetic resonance (MR) mammography. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Twenty-six consecutive women (mean age, 47.8 years) suspected of having a breast tumor at mammography and sonography underwent two identical MR examinations at 1.5 T; examinations were separated by more than 48 hours but less than 72 hours. A T1-weighted three-dimensional gradient-echo sequence was used, and images were acquired before and at 0, 2, 4, 6, and 8 minutes after randomized injection of gadopentetate dimeglumine or gadobenate dimeglumine at an identical flow rate of 2 mL/sec. Separate and combined assessment of unenhanced, contrast-enhanced, and subtracted images was performed blindly by two readers in consensus. Accuracy for lesion detection was determined against a final diagnosis based on findings at conventional mammography, sonography, and surgery. Sensitivity, specificity, positive and negative predictive values, and overall accuracy for malignant lesion identification were determined against histologic results. Data were analyzed with the McNemar test, proportional odds models, and analysis of variance. RESULTS: MR mammography with gadobenate dimeglumine depicted significantly (P = .003) more lesions (45 of 46) than did that with gadopentetate dimeglumine (36 of 46), and detected lesions were significantly (P < .001) more conspicuous with gadobenate dimeglumine. Confidence for characterization was significantly (P = .031) greater with gadobenate dimeglumine. Comparison of the contrast agents for their ability to help identify malignant lesions revealed significant (P = .02) superiority for gadobenate dimeglumine: Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy for malignant lesion identification were, respectively, 94.7%, 100%, 100%, 80.0%, and 95.6% with gadobenate dimeglumine and 76.3%, 100%, 100%, 47.1%, and 80.4% with gadopentetate dimeglumine. Quantitative evaluation of signal intensity-time curves revealed significantly (P < .001) greater lesion enhancement with gadobenate dimeglumine. CONCLUSION: Detection of breast lesions and accurate identification of malignant lesions at MR imaging are significantly superior with gadobenate dimeglumine in comparison with gadopentetate dimeglumine.

Adult↗

Low-dose multidetector-row CT angiography of the infra-renal aorta and lower extremity vessels: image quality and diagnostic accuracy in comparison with standard DSA.

To investigate the possibility of reducing X-ray exposure during multidetector-row spiral computed tomographic (MDCT) angiography and to compare the image quality and diagnostic accuracy of different dosages with digital subtraction angiography (DSA) in the evaluation of the infra-renal aorta and lower extremities vessels. Seventy-five patients, randomly divided into three groups of 25 patients each, were evaluated for atherosclerotic disease with four-row spiral CT angiography (4x2.5 mm) and DSA. MDCT scanning parameters were kept constant, except for milliamperage (mAs): group A: 50 mAs; group B: 100 mAs; group C: 130 mAs. Images were analysed by two vascular radiologists in consensus. DSA represented the standard of reference. The diagnostic value of MDCT and total radiation exposure were evaluated for each data set. The simulated effective dose was 3.7 mSv for 50 mAs, 8.2 mSv for 100 mAs and 13.7 mSv for 130 mAs for men, and 4 mSv for 50 mAs, 8.9 mSv for 100 mAs and 14.8 mSv for 130 mAs for women. The dose reduction was 74% for group A and 40% for group B. The evaluation of the presence and degree of stenoses revealed a sensitivity, specificity, accuracy, PPV and NPV of 96%, 94%, 95%, 83% and 99% for Group A (50 mAs), 96%, 96%, 96%, 89% and 99% for Group B (100 mAs) and 98%, 96%, 97%, 91% and 100% for the standard dose protocol, Group C (130 mAs). Low-dose scanning is thus a feasible and accurate option for four-row CT angiography of the peripheral vessels. This technique provides substantial reduction of the radiation dose delivered to the patient while maintaining optimal diagnostic accuracy.

Adult↗

ECG-gated multi-detector row spiral CT in the assessment of myocardial infarction: correlation with non-invasive angiographic findings.

Our objective was to retrospectively evaluate the ability of multidetector-row computed tomography (MDCT) to detect previous myocardial infarctions (MIs) and to correlate necrosis with the status of coronary arteries supplying the infarcted territory. After having clinically evaluated 187 patients referred for ECG-gated MDCT of the coronary arteries, 30 previous MIs were identified in 29 patients (9 recent and 21 chronic). MDCT data were evaluated qualitatively and quantitatively by measuring attenuation values and wall thickness within the infarcted region and normal adjacent myocardium. Each MI was also assigned to the distribution territory of a coronary vessel, and morphological data were combined with MDCT angiographic findings. MDCT was able to detect 25/30 MIs showing an overall sensitivity and specificity of 83 and 91%, respectively. Quantitative analysis revealed a statistically significant difference in attenuation values between normal and infarcted regions (38.9+/-14 HU vs. 104.0+/-16 HU). Regional wall thinning was observed in chronic MIs (4.1+/-2 mm vs. 10.5+/-3.8 mm), and not in patients with recent event (7.9+/-1.6 mm vs 9.1+/-4 mm). In 22/25 cases, MDCT angiographic findings showed the presence of suspicious critical lumen narrowing (n=3), previous coronary stenting (n=14) and surgical revascularization (n=5) in the infarct-related coronary. During a single examination, MDCT might provide comprehensive imaging of MI offering a combined morphological and angiographic assessment.

Adult↗

Small bowel.

MR imaging, using modern equipment and a rigorous technical approach, can offer detailed morphologic information and functional data on the small bowel. The optimal study technique is debatable, although the oral administration of contrast material as a first-line approach is less expensive, faster, easier to perform, and better tolerated by patients. MR enteroclysis might be reserved for selected cases as a second-line study. The major clinical indication is the evaluation of patients who have suspected or known Crohn's disease. The absence of ionizing radiation, considering the young age of most of the patients and the frequency of the examinations, is an important advantage over other techniques (radiograph and CT enteroclysis).

Contrast Media↗

Color-coded automated signal intensity curves for detection and characterization of breast lesions: preliminary evaluation of a new software package for integrated magnetic resonance-based breast imaging.

OBJECTIVES: The objective of this study was to evaluate the value of a color-coded automated signal intensity curve software package for contrast-enhanced magnetic resonance mammography (CE-MRM) in patients with suspected breast cancer. MATERIALS AND METHODS: Thirty-six women with suspected breast cancer based on mammographic and sonographic examinations were preoperatively evaluated on CE-MRM. CE-MRM was performed on a 1.5-T magnet using a 2D Flash dynamic T1-weighted sequence. A dosage of 0.1 mmol/kg of Gd-BOPTA was administered at a flow rate of 2 mL/s followed by 10 mL of saline. Images were analyzed with the new software package and separately with a standard display method. Statistical comparison was performed of the confidence for lesion detection and characterization with the 2 methods and of the diagnostic accuracy for characterization compared with histopathologic findings. RESULTS: At pathology, 54 malignant lesions and 14 benign lesions were evaluated. All 68 (100%) lesions were detected with both methods and good correlation with histopathologic specimens was obtained. Confidence for both detection and characterization was significantly (P < or = 0.025) better with the color-coded method, although no difference (P > 0.05) between the methods was noted in terms of the sensitivity, specificity, and overall accuracy for lesion characterization. Excellent agreement between the 2 methods was noted for both the determination of lesion size (kappa = 0.77) and determination of SI/T curves (kappa = 0.85). CONCLUSIONS: The novel color-coded signal intensity curve software allows lesions to be visualized as false color maps that correspond to conventional signal intensity time curves. Detection and characterization of breast lesions with this method is quick and easily interpretable.

Adult↗

Hepatocellular carcinoma: role of unenhanced and delayed phase multi-detector row helical CT in patients with cirrhosis.

PURPOSE: To determine, by using multi-detector row helical computed tomography (CT), the added value of obtaining unenhanced and delayed phase scans in addition to biphasic (hepatic arterial and portal venous phases) scans in the detection of hepatocellular carcinoma (HCC) in patients with cirrhosis. MATERIALS AND METHODS: Local ethical committee approval and patient consent were obtained. One hundred ninety-five patients (129 men, 66 women; mean age, 61 years; age range, 39-78 years) with 250 HCCs underwent multi-detector row helical CT of the liver. A quadruple-phase protocol that included unenhanced, hepatic arterial, portal venous, and delayed phases was performed. Analysis of images from hepatic arterial and portal venous phases combined, hepatic arterial and portal venous phases with the unenhanced phase, hepatic arterial and portal venous phases with the delayed phase, and all phases combined was performed separately by three independent radiologists. Relative sensitivity, positive predictive value, and area under the receiver operating characteristic curve (A(z)) were calculated for each reading session. RESULTS: Mean sensitivity and positive predictive values, respectively, for HCC detection were 88.8% (666 of 750 readings) and 97.8% (666 of 681 readings) for the combined hepatic arterial and portal venous phases, 89.2% (669 of 750 readings) and 97.8% (669 of 684 readings) for hepatic arterial and portal venous phases with the unenhanced phase, 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for hepatic arterial and portal venous phases with the delayed phase, and 92.8% (696 of 750 readings) and 97.3% (696 of 715 readings) for all four phases combined. The reading sessions in which delayed phase images were available for interpretation showed significantly (P < .05) superior sensitivity and A(z) values. CONCLUSION: Unenhanced phase images are not effective for HCC detection. Because of the significant increase in HCC detection, a delayed phase can be a useful adjunct to biphasic CT in patients at risk for developing HCC.

Adult↗

Colorectal polyps: detection with low-dose multi-detector row helical CT colonography versus two sequential colonoscopies.

PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multi-detector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis. RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%. CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.

Aged↗

Contrast-enhanced sonography with SonoVue: enhancement patterns of benign focal liver lesions and correlation with dynamic gadobenate dimeglumine-enhanced MRI.

OBJECTIVE: Contrast-enhanced real-time low-mechanical-index sonography is a new diagnostic technique for the assessment of macro- and microcirculation. The purpose of our article is to describe contrast-enhancement patterns of different benign focal liver lesions using the second-generation contrast agent SonoVue and to compare these findings with those of gadobenate dimeglumine-enhanced MRI. CONCLUSION: SonoVue-enhanced real-time low-mechanical-index sonography provides specific contrast-enhancement patterns of different benign focal liver lesions, allowing accurate characterization. Findings on SonoVue-enhanced sonography correlate well with those obtained on gadobenate dimeglumine-enhanced MRI.

Adult↗