Office automation brings new efficiencies to the CEO's desk.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Warner.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A pharmacokinetic model is proposed to describe the plasma levels of isosorbidedinitrate (ISDN) and its two pharmacologically active metabolites, isosorbide-2-mononitrate (IS-2MN) and isosorbide-5-mononitrate (IS-5MN), following the oral administration of several 20-mg sustained release formulations of ISDN. Absorption of ISDN from the gastrointestinal tract appears first-order. A three compartment model is used to describe ISDN systemic plasma levels with t1/2 alpha = 7 min, t1/2 beta = 48 min and t1/2 gamma = 7.5 hr. The long t1/2 gamma is due to the slow release of ISDN from a peripheral compartment. ISDN undergoes extensive first-pass hepatic metabolism to IS-2MN and IS-5MN. The metabolic pathways appear to be close to saturation at an ISDN dose of 20 mg. Both IS-2MN and IS-5MN systemic plasma levels can be described by one compartment models with first-order elimination (respective elimination half-lives are 1.9 and 5.1 hr). The central compartment volumes of distribution for ISDN, IS-2MN and IS-5MN (116, 57, and 38 liters, respectively) are in agreement with reported literature values. This model is of particular usefulness as a formulation tool in designing sustained release ISDN formulations of the type investigated here since the observed first-order absorption rate constant correlates well with the in vitro first-order dissolution rate constant. Therefore, for these formulations, plasma levels can be simulated using data generated from in vitro dissolution studies, thus obviating the need for multiple human bioavailability studies.
Explore the source record for details and available documents.
This paper describes a formula for estimating patient skin entrance exposures from representative techniques used in radiographic facilities. A flexible nomogram has been formatted to the parameters of patient dimensions and focal film distance. The corresponding exposure rate (mGy/mAs) is expressed for any assumed projection and selected kilovoltages. This measured approach is a valuable tool for exposure assessment and is in compliance with emerging government standards and the pursuit of the ALARA (as low as reasonably achievable) concept.
Explore the source record for details and available documents.