The effect of magnetization transfer in meniscal fibrocartilage.

Magnetic resonance imaging of the knee was performed in 28 patients (ages 15-72 years), using a 1.5-T unit. Volume gradient echo (3D GRASS) acquisition with and without presaturation off-resonance RF pulse was used to evaluate magnetization transfer (MT) effects, determined by placing regions of interest on muscle, fat, hyaline, and fibrocartilage; the percent change in signal intensity was calculated and compared using a paired two-sample t test. An in vitro study of the normal meniscus from a cadaver containing a scalpel cut extending to an articular surface was performed to observe the relative improvement in contrast in the presence of a small meniscal defect. MR imaging of the specimen was performed using an Omega CSI 2.0-T system (General Electric Medical Systems, Fremont, CA). Analysis of clinical images resulted in signal loss, compared to that of the identically timed and tuned non-MT images of 47 +/- 5, 8 +/- 5, 49 +/- 5, and 57 +/- 7% for muscle, fat, articular cartilage and fibrocartilage, respectively. Application of MT improved the depiction of the artificially introduced meniscal defect. Meniscal fibrocartilage demonstrates significant MT effect after application of off-resonance RF presaturation, which may improve visualization of meniscal defects.

Adolescent↗

A three-component model for magnetization transfer. Solution by projection-operator technique, and application to cartilage.

A projection-operator technique is applied to a general three-component model for magnetization transfer, extending our previous two-component model [R.S. Adler and H.N. Yeung, J. Magn. Reson. A 104, 321 (1993), and H.N. Yeung, R. S. Adler, and S.D. Swanson, J. Magn. Reson. A 106, 37 (1994)]. The PO technique provides an elegant means of deriving a simple, effective rate equation in which there is natural separation of relaxation and source terms and allows incorporation of Redfield-Provotorov theory without any additional assumptions or restrictive conditions. The PO technique is extended to incorporate more general, multicomponent models. The three-component model is used to fit experimental data from samples of human hyaline cartilage and fibrocartilage. The fits of the three-component model are compared to the fits of the two-component model.

Adult↗

Ultrasound-guided injection of ganglia with coricosteroids.

OBJECTIVE: The aim of this study was to demonstrate the use of ultrasound guidance in confirming intralesional injection of corticosteroids and local anesthetic into symptomatic ganglia, and to propose potential advantages of this technique. DESIGN AND PATIENTS: Ten patients (five men, five women) underwent ultrasound-guided injection of a ganglion. Seven ganglia were near the wrist, one was adjacent to a finger interphalangeal joint and two were adjacent to the talus. All were injected with a 1:1 mixture of long-acting corticosteroid and local anesthetic, the actual volume being dependent on the size of the ganglion. Three patients had a second injection 9-18 months following the initial injection. RESULTS: In four patients the ganglia resolved completely. In five patients there was significant improvement, with a reduction in size of the ganglion and symptomatic relief. CONCLUSION: Ultrasound-guided injection insures intralesional deposition of corticosteroids and may provide an alternative to surgery in the management of ganglia.

Adult↗

Autocorrelation of integrated power Doppler signals and its application.

The integrated power Doppler signal arising from blood flow is a random process. In this article, a general approach to model this random process is studied. Both the theoretical and experimental results show that the temporal autocorrelation function of the integrated power Doppler signals is directly related to properties of the insonified medium, such as the scattering strengths and velocities of all moving scatterers, and as well as the properties of the Doppler imaging system, such as the point spread function (psf) of the power Doppler images. Some initial experiments are performed to test the proposed model. Its potential application for flow measurement, such as perfusion evaluation, is also discussed.

Blood Flow Velocity↗

The hemodynamics of transjugular intrahepatic portosystemic shunts: investigations with Doppler sonography and development of an in vitro model.

RATIONALE AND OBJECTIVES: We evaluated Doppler sonography-based measurements of transjugular intrahepatic portosystemic shunt (TIPS) function and developed an in vitro model of normal TIPS hemodynamics. METHODS: We reviewed retrospectively the results of all trans-TIPS manometries (N = 116) performed during a 24-month period. Portosystemic pressure gradient was compared with peak stent velocity as measured by angle-corrected Doppler sonography. A flow phantom simulating TIPS was created using 8-, 10-, and 12-mm-diameter wire-mesh stents placed in cylindrical channels with lengths ranging from 3.4 to 6.0 cm. RESULTS: Among 50 trans-TIPS manometries with corresponding Doppler sonography performed on well-functioning shunts, measured portosystemic pressure gradient and peak velocity were not correlated (R2 = .014). On the basis of a regression of measurements in the flow phantom, pressure loss in a stented cylindrical channel was estimated as follows: delta p = rho.(0.145 -0.001.Rey + 0.816.L/D).(Vmean2/2), where rho is the fluid density, Rey is the Reynolds number, L is the channel length, D is the stent diameter, and Vmean is the time-averaged velocity within the stent. Predicted and measured pressure gradients were correlated (R2 = .91). CONCLUSION: Peak velocity in patients with a normally functioning TIPS does not predict the magnitude of the portosystemic pressure gradient.

Blood Flow Velocity↗

Power Doppler sonography of synovitis: assessment of therapeutic response--preliminary observations.

Power Doppler sonography was used in eight symptomatic knees in seven patients with arthritis before and after joint aspiration and intraarticular administration of steroids. A qualitative decrease in synovial perfusion was observed in all eight knees, and symptoms improved in seven of the eight cases. These preliminary data suggest a role for power Doppler sonography in assessment of serial changes in synovial inflammation.

Adult↗

Power Doppler sonography in the assessment of musculoskeletal fluid collections.

OBJECTIVE: Power Doppler sonography is a relatively new technique that has been shown to depict hyperemia associated with musculoskeletal inflammatory disease. We performed this study to evaluate the ability of power Doppler sonography to differentiate musculoskeletal fluid collections of varying etiologies. SUBJECTS AND METHODS: Gray-scale and power Doppler sonography were performed on 39 patients with joint effusions or appendicular fluid collections. Blood flow (hyperemia) in the soft tissues adjacent to the fluid collections was subjectively analyzed and graded on a scale of 1 to 4 (1, normal flow; 2-4, increasing degrees of hyperemia). All fluid collections were aspirated within 24 hr of the sonographic examination. We found 31 joint effusions and 12 periarticular collections with appropriate imaging and pathologic correlation. RESULTS: Adjacent to 36 effusions and fluid collections, we saw moderate or marked hyperemia. Thirty-five of the 36 had an inflammatory or neoplastic cause, including 15 infected collections. One fluid collection had a degenerative etiology (subdeltoid bursitis secondary to supraspinatus tendon tear). Adjacent to the seven remaining effusions and fluid collections, we saw normal or mildly increased hyperemia; none of these collections had an inflammatory etiology. CONCLUSION: Power Doppler sonography helps distinguish inflammatory and infectious musculoskeletal fluid collections from those that are noninflammatory, and it may help guide the decision to perform diagnostic aspiration. Power Doppler sonography does not reliably differentiate between inflammatory collections of infectious and noninfectious origin because collections of either origin may significantly increase adjacent soft-tissue perfusion.

Adult↗

An ultrasound method to evaluate polyethylene component wear in total knee replacement arthroplasty.

Evaluation of a painful total knee replacement has been limited to physical examination, aspiration, plain radiographs, and radionuclide studies. Visualization of the polyethylene tibial-bearing component without surgery has not been possible. Polyethylene wear is a well-recognized cause of total knee replacement failure. We have developed an ultrasound method to evaluate polyethylene insert shape and thickness with the ability to clearly demonstrate structural loss of plastic. Before clinical trials, a total knee replacement was cemented into a fresh cadaver knee. Ultrasound imaging of the polyethylene insert was performed in the longitudinal plane using a 10 MHz linear transducer. A characteristic bone/metal/polyethylene interface enabled recognition of the insert material from which its dimension was estimated. The entire perimeter of the liner, the metal tray, and the bone-metal interface was visualized. Five consecutive measurements at each location were performed on each of the 8-, 10-, and 12-mm polyethylene liners with the ultrasonographer blind to the insert thickness. Once removed, measurements were made directly on the liners adjacent to the marked points with an electronic caliper. Coefficient of variation (r2) ranged from 1.6% to 8.3% for the ultrasound measurements, and 0.26% to 1.5% for the caliper measurements. A plot of ultrasound versus caliper measurements allowed calculation of a linear equation, with r2 = 0.98, demonstrating high correlation between the two measurements. Our ultrasound measurements are accurate to 0.5 mm with a 95% confidence interval. Ultrasound is an accurate way to measure the dimensions of the polyethylene liner in total knee replacement arthroplasty. Early experiences with ultrasound evaluation prior to revision have been very encouraging for the evaluation of polyethylene wear, defects, and of prosthetic loosening.

Anthropometry↗

Ultrasonic estimation of tissue perfusion: a stochastic approach.

Imaging of blood flow perfusion is an area of significant medical interest. Recently, the advantages of using the total integrated Doppler power spectrum as the parameter that is encoded in color has been shown to result in an approximately threefold increase in flow sensitivity, a relative insensitivity to acquisition angle and lack of aliasing. We have taken this mode a step further and demonstrated the potential for quantifying blood flow using correlation-based algorithms applied to the power signal. We show that phi(tau) = phi(0)e-VT, where phi(tau) is the two-time correlation of the fluctuation in the power signal, and v is the specific flow (reciprocal of mean transit time). Scans of a dog's blood, pumped at a constant rate through gum rubber tubing, were obtained using a Diasonics Spectra 10-MHz linear array transducer at standard range-gated spectral mode (PRF = 1400 Hz, wall filter = 50 Hz, sample gate = 1.5 mm). A fixed Doppler angle of 68 degrees was used. Five different flow rates were tested, and the velocities determined by power decorrelation were compared to the mean velocities calculated from the Doppler shifts by linear regression (R2 = 0.987). We believe the results are very encouraging for using power decorrelation in perfusion evaluation.

Algorithms↗

Ultrasound tissue displacement imaging with application to breast cancer.

A method for quantitative imaging of internal tissue motion based on speckle tracking is described. Tissue displacement images from eight patients with sonographically apparent breast masses are used to illustrate the technique. The local displacement response of tissues surrounding malignant and benign breast masses is compared, testing the hypothesis that altered mechanical properties may result in motion signatures for many soft tissue tumors relative to their host tissue. In addition, the potential or anticipated influence of various biological and physical factors on tissue motion response is discussed.

Adult↗

Nonpulsatile arterial waveforms: observations during graded testicular torsion in rats.

RATIONALE AND OBJECTIVES: We tested whether testicular torsion could completely damp distal arterial pulsatility, resulting in venous-appearing arterial waveforms. METHODS: Progressively increasing testicular torsion was unilaterally produced in five rats. Doppler waveforms of the testicular artery distal to the torsion were obtained as soon as possible after each level of torsion until a complete absence of pulsatility was noted. RESULTS: One animal was not studied further after the first 180 degrees of torsion occluded flow. In three of the remaining four animals, the testicular artery resistive index (RI) at baseline (0.51, 0.58, 0.64) was within the range of the normal human intratesticular RI and decreased with increasing torsion, culminating in nonpulsatile, venous-appearing waveforms at high degrees of torsion. CONCLUSIONS: Testicular torsion can completely damp arterial pulsatility, resulting in nonpulsatile, venous-appearing arterial Doppler waveforms.

Animals↗

Magnetic-resonance imaging techniques for detection of elasticity variation.

The relative success of manual palpation in the detection of breast cancer would suggest that a method for remote palpation resulting in a measurement of tissue elasticity could provide a diagnostic tool for detecting cancerous lesions deeper within the breast. This presumption is based in part on the excellent contrast between neoplastic and normal tissue due to the large (orders of magnitude) relative variation in the shear elastic modulus. By comparison, the bulk deformational modulus maintains the same value to within 20% for most soft tissues. A specific method of magnetic-resonance imaging (MRI) which measures tissue displacements has been used in experiments with a phantom containing regions of increased Young's modulus as a demonstration. The spatial modulation of magnetization technique uses the displacement of a spatial grid pattern caused by spin saturation to track regional motion. Mathematical reconstruction of the distribution of elastic moduli is shown for select examples. Any modality, e.g., MRI, ultrasound, etc., which can detect local tissue motion with sufficient spatial resolution can be used and therefore the results presented here should give an indication of the utility of such motion tracking techniques to future measurement of tissue elasticity.

Biophysical Phenomena↗

Fractional moving blood volume: estimation with power Doppler US.

PURPOSE: To estimate the fraction of moving blood in tissue with power Doppler ultrasound (US). MATERIALS AND METHODS: Power Doppler US measurements of moving scatterers in a flow tube were made as a function of successive dilutions of the perfusate. Measurements were normalized relative to the maximum Doppler power in the center of the flow tube at the highest concentration and were used to calculate the fractional dilution of the perfusate for each run with each dilution used to represent increasing amounts of non-moving soft tissue in the sample volume. The technique was also applied to two clinical examples. RESULTS: Successive dilutions of the perfusate in the flow experiment showed a monotonic, linear decrease in the Doppler power as a function of dilution. CONCLUSION: The power Doppler US technique has the potential to more accurately estimate alterations in blood flow and has the advantage of being a continuous parameter that can be depth normalized.

Blood Circulation↗

Quantitative assessment of surface roughness using backscattered ultrasound: the effects of finite surface curvature.

We have previously described a technique to quantify surface fibrillatory changes in osteoarthritic articular cartilage. In that study, the angular distribution of the scattered acoustic field from an insonifying source directly related to the distribution of surface fibrillatory changes. In the current study, we demonstrate a more sensitive method to quantify surface roughness, the effect of global surface curvature in estimating surface roughness and the utility of using focused transducers in circumventing this potential problem for in vivo work. Phantoms composed of acrylic rods with and without sandpaper grit (about 15 to 72 microns, mean particle size) applied to the surface were scanned. A more robust angular scattering technique to measure the angle dependent data was employed, in which the integrated squared pressure amplitude over a finite time window (mean power) was measured as a function of incident acoustic angle for varying surface roughnesses and radii of curvature. We show that the potential dynamic range for making roughness discriminations diminishes with decreasing radius of curvature of the acrylic rod phantoms using an unfocused transducer. This effect is minimized with use of a focused transducer. Roughness effects are most evident at sufficiently large angles where incoherent scattering dominates. We conclude that the roughness of cylindrically curved surfaces can be quantitatively assessed using a focused ultrasound beam at sufficiently large incident angles, given that the focal spot size is sufficiently smaller than the radius of curvature of the surface.

Cartilage, Articular↗

The use of ultrasound mean acoustic attenuation to quantify bone formation during distraction osteogenesis performed by the Ilizarov method. Preliminary results in five dogs.

RATIONALE AND OBJECTIVES: Management of distraction during Ilizarov limb lengthening remains primarily clinical and empirical. Estimates of tissue acoustic attenuation were evaluated for their ability to quantify bone formation within the distraction gap. METHODS: Five dogs had tibias lengthened by the method of Ilizarov. Mean acoustic attenuation measurements at multiple positions across the distraction gap were compared with corresponding x-ray computed tomography attenuation measurements. RESULTS: Computed tomography and ultrasound attenuation displayed similar quantitative behavior across the gap. Linear correlation between them ranged from R2 = .878 to R2 = .131. Fibrous interzone width estimates based on computed tomography and ultrasound attenuation measurements were correlated, based on our preliminary data with R2 = .519. These estimates are independent of the width of distraction. CONCLUSIONS: Ultrasound parallels computed tomography as a measure of bone formation within the distraction gap. Future studies are needed to improve acoustic attenuation data acquisition techniques and to evaluate their potential as a tool for optimizing early distraction rates in patients at risk for rate-related complications.

Acoustics↗