Search PubMed⌕ Search

Biomedical subjects

R Puchal

Publications and source records attributed to R Puchal.

23 records · Page 2Linked to original sources

Granulocyte-specific monoclonal antibody technetium-99m-BW 250/183 and indium-111 oxine-labelled leucocyte scintigraphy in inflammatory bowel disease.

Thirty-three patients suspected of suffering from inflammatory bowel disease were studied. Autologous leucocytes were labelled with indium 111 oxine and re-injected simultaneously with 0.3-0.5 mg of technetium 99m granulocyte-specific monoclonal antibody BW 250/183. Two scans were obtained, the early scan 3-4 h postinjection (p.i.) and the late scan 18-24 h p.i. Using the endoscopy study as standard, the diagnostic accuracy of both agents was determined. Sensitivity, specificity and accuracy of 111In scans was 88.8%, 100.0% and 93.7% at 4 h and 94.7%, 100.0% and 96.9% at 24 h, respectively. Concerning the results using antibodies, the values were 61.1%, 100.0% and 78.1% at 4 h and 78.9%, 92.8% and 84.8% at 24 h, respectively. Segmental analysis showed concordance in 89.3% and 93.3% of the cases at 4 and 24 h, respectively. Though less sensitive and less accurate than scanning employing indium 111 leucocytes, BW 250/183 granulocyte-specific scintigraphy can be used for inflammatory bowel disease diagnosis and localization.

Adult↗

Optimal filtering values in renogram deconvolution.

The evaluation of the isotopic renogram by means of the renal retention function (RRF) is a technique that supplies valuable information about renal function. It is not unusual to perform a smoothing of the data because of the sensitivity of the deconvolution algorithms with respect to noise. The purpose of this work is to confirm the existence of an optimal smoothing which minimises the error between the calculated RRF and the theoretical value for two filters (linear and non-linear). In order to test the effectiveness of these optimal smoothing values, some parameters of the calculated RRF were considered using this optimal smoothing. The comparison of these parameters with the theoretical ones revealed a better result in the case of the linear filter than in the non-linear case. The study was carried out simulating the input and output curves which would be obtained when using hippuran and DTPA as tracers.

Humans↗

Calculation of portal contribution to hepatic blood flow with 99mTc-microcolloids. A noninvasive method to diagnose liver graft rejection.

The portal contribution (PC) to hepatic blood flow was calculated in 13 liver graft patients and 13 normal volunteers. The method is based on the quantification and normalization of the liver and spleen activity after the administration of 7 mCi (259 MBq) of 99mTc microcolloid. Forty examinations were performed in liver grafts and 13 in normal subjects. The PC was significantly higher in normal native liver (64.0 +/- 3.0%) than in functioning grafts (58.8 +/- 3.1%). In acutely rejecting patients, PC was significantly lower (52.4 +/- 2.0%) than in functioning grafts and similar to that observed in cholangitis (53.5 +/- 0.7%). The PC increases again once rejection has resolved (57.3 +/- 2.6%). During hepatitis post-transplant PC values (59.7 +/- 3.4%) were similar to those observed in functioning grafts. Overall, PC values over 55% are very unlikely to be due to rejection.

Adult↗