Search PubMed⌕ Search

Biomedical subjects

R Puchal

Publications and source records attributed to R Puchal.

At least 19 recordsLinked to original sources

[Tomographic studies of myocardial perfusion normality with 99m Tc-Tetrofosmin. Spanish multicenter study].

As a first phase in a nationwide multicenter study to obtain myocardial perfusion normality patterns, this work presents the study design and quality control methodology used to guarantee that the gammacameras fulfilled some minimum quality requirements. The following aspects were considered in the study design in order to guarantee the homogeneity and interchangeability of the results: creation and structure of the work group, data interchange system, data selection and acquisition, centralized archiving and processing, assessment system, study acceptance criteria and distribution of the results. To carry out the instrumental quality control, three phantom studies were established, one to control the rotation center, another to verify tomographic uniformity and a third to simulate the shape and orientation of the left ventricle. The three phantoms circulated through all of the 18 participating centers in this project, which corresponded to 19 gammacameras. Very strict guidelines had to be followed in the acquisition and processing of these phantom studies. If any camera and/or center did not fulfill the criteria established, it was advised of the problem detected in order to correct it. Once the defect was repaired, all the phantoms were sent again for verification. Uniformity of the rotation center was quantified by means of the eccentricity of a 360 degrees orbit, admitting up to a maximum of 10%. Tomographic uniformity was visually assessed, taking in account the number of slices with rings and their contrast and finally no artifacts could be present in the reconstructed study of the ventricle. The center of rotation was within limits in all the cameras except one case while the tomographic uniformity was incorrect in 6 cases. All the departments, except one, corrected the defects detected, and passed the acceptance test. The results made it possible to guarantee adequate homogeneity and instrumental quality in this multicenter study.

Coronary Circulation↗

[Tomographic studies of myocardial perfusion normality with 99m Tc-Tetrofosmin. Spanish multicenter study].

This objective of this study was to obtain a pool of Myocardial Perfusion SPECTs with a 99mTetrofosmin stress/rest one day protocol in normal volunteers having a less than or equal to 5% likelihood of coronary artery disease that represents normalcy in the Spanish population. A total of 169 volunteers from 15 hospitals were studied. The volunteers were divided into 5 groups: Groups 1, 2 or 3 corresponding to men < 30 years (n = 33), men between 30 and 50 years (n = 32), or men > 50 years (n = 31); Groups 4 or 5: premenopausal (n = 38) or postmenopausal women (n = 35). A clinical history, physical examination, clinical laboratory parameters, echocardiography and a symptom limited exercise stress test were performed in all of them and had to be normal. The mean likelihood of coronary artery disease was 1.15 +/- 1.07%.Twenty-four segments were analyzed in each study and were classified into 5 grades of uptake (1 = normal, 2, 3, 4 = mild, moderate or severe defect and 5 = no uptake). Defects were then analyzed according to sex and location. Considering the stress and rest studies separately (8,112 segments), only 19 moderate and 75 mild defects were found, these corresponding to 16 volunteers, with more inferior defects in men and anterior defects in women. These data validate the normalcy of our population. A pool of Myocardial Perfusion SPECTs with a 99mTetrofosmin stress/rest one day protocol in normal volunteers that represents Spanish normal values was obtained.

Adult↗

[Study of renal transplant by deconvoluted renogram with 99m Tc-mercaptoacetyltriglycine (Mag3)].

AIM: To evaluate the usefulness of the 99mTc-MAG3 renogram deconvolution and its derived parameters in kidney graft function monitoring. MATERIAL AND METHOD: 221 renograms were studied: 64 were diagnosed as functioning graft (FG), 37 as functioning graft with elevated serum creatinine (FG2), 59 as acute tubular necrosis (ATN), 30 as acute rejection (AR), 20 as urinary tract obstruction (OBS) and 11 as cyclosporine nephrotoxicity (TNX). The parameters evaluated were: maximal activity of conventional renogram and mean transit time (MTT), time to reach 20% (T20) and 80% (T80) of the height of the RRF and initial uptake (IU) from the deconvoluted renal retention function (RRF). RESULTS: MTT and T20 were significantly longer and IU significantly lower in non-functioning grafts. However, MTT and T20 became shorter than in FG when graft function is severely impaired. CONCLUSION: IU, MTT and T20 are more useful than maxim activity of renogram in monitoring kidney graft function and in evaluating renal dysfunction severity. IU is a very sensitive and early parameter.

Adult↗

Validation of the preparation of individual doses of (131)I-sodium o-iodohippurate ((131)I-hippuran).

The preparation of low activity doses of (131)I-hippuran has a drawback due to its high radioactivity concentration. In this study we diluted the radiopharmaceutical with saline or phosphate buffered saline (PBS) in order to decrease the radioactivity concentration, facilitate the preparation of individual doses and validate these procedures. We prepared doses of approx. 1.85 MBq of (131)I-hippuran from 10 different batches the day before the calibration date: undiluted, and diluted 1:9 with saline or PBS. The radiochemical purity (RCP) was evaluated the day after the expiration date. The percentage of (131)I-hippuran retained on syringes was assessed in vitro, after emptying the syringe and washing it twice with water (n=3 x 27); and in vivo, after the endovenous administration of the dose and washing the syringe twice with the patient's blood (n=3 x 75). Sterility was assessed using fluid thyoglicolate medium (n=3 x 15). All RCP values were greater than those required by the European Pharmacopoeia (>96%) except one of the undiluted (131)I-hippuran (95.8%) doses. No statistical difference was observed among them. The mean undiluted (131)I-hippuran retained in vitro was 5.4% (SD=6.5%), statistically greater (P<0.01) than both saline diluted (mean=1.5%, SD=1.1%) and PBS diluted (mean=2.0%, SD=2.4%). The mean undiluted (131)I-hippuran retained in vivo was 6.4% (SD=5.4%), statistically greater (P<10-5) than both saline diluted (mean=3.1%, SD=2.3%) and PBS diluted (mean=3.1%, SD=3.1%). We concluded that: (1) the dilution of (131)I-hippuran with saline or PBS makes both the preparation of individual doses and its administration to the patient easier without decreasing its radiopharmaceutical quality; and (2) using saline or PBS diluted (131)I-hippuran the percentage of radiopharmaceutical retained on the syringes, after use, is minimized.

Humans↗

Blood volumes and renal function in overt and subclinical primary hypothyroidism.

INTRODUCTION: Thyroid dysfunction is associated with marked alterations in cardiovascular and renal functions. In hypothyroidism, myocardial contractility, cardiac output, and oxygen consumption are decreased, whereas peripheral resistance is increased. METHODS: We assessed blood volumes and effective renal plasma blood flow (ERPF) and glomerular filtration rate (GFR) in 17 patients with overt primary hypothyroidism and in 15 of these patients when in euthyroid state after substitutive therapy. We performed the same measurements in eight patients with subclinical hypothyroidism. RESULTS: In the hypothyroid state, the plasma volume measured by dilution of 125I-albumin (APV) was higher than the calculated plasma volume (CPV) from packed red cell mass, suggesting an extravascular escape of albumin. After substitutive therapy, the CPV showed a statistical increase (P < 0.05), whereas APV remained unchanged. Both ERPF and GFR increased after thyroxine therapy (p < 0.05). In the subclinical group, blood volumes and renal function were similar to those found in the other group of patients when in the euthyroid state. CONCLUSIONS: We conclude that in primary hypothyroidism, ERPF and GFR are low, but that these values improve with substitutive therapy. CPV is a better index of the current plasma volume than APV. The difference between these two parameters suggests that the escape of albumin into the extravascular space in primary hypothyroidism is terminated by treatment. There are no clear abnormalities either in blood volumes or in renal function in subclinical hypothyroidism.

Adolescent↗

[Quantification of liver volume by SPECT].

This study aimed to optimize a method to estimate liver volume by SPECT. Several phantoms were used to simulate the liver shape with a volume between 400 and 2,500 cc. The SPECT studies were acquired using 360 degrees and 180 degrees circular orbits, 64 projections, 64 x 64 word matrix, all purpose parallel-hole collimator and were reconstructed with a HANN filter with frequency cutoff = 0.5 cycles/ pixel. The reconstructed studies were processed with a program that estimates the organ volume for different threshold cutoff levels for counting. The optimum cutoff threshold level to quantify the liver volume was 50% and 48% for 360 degrees orbits and 180 degrees orbits, respectively. A linear relationship was observed between the real and calculated volumes with r = 0.994 for the 360% orbits and r = 0.976 for the 180 degrees orbits, The average error between corrected and real volumes was 4.2% and 10.87% for both orbits, respectively. The method was applied to 14 patients with different degrees of hepatomegaly who had undergone a liver 99mTc-sulfur colloid scintigraphy. The intra and interobserver variability as well as the influence of the degree of contour adjustment of the phantom mask were studied. No significant differences were observed in the results, so that it can be considered that neither the mask trace nor the operator influence the results.

Anthropometry↗

[Classification of kidney grafts by renographic parameters].

The aim of this work was to analyze the use of some renographic parameters derived from the 99mTc-MAG3 renogram to classify post-transplantion studies in two groups: Normal functioning grafts (NFG) and delayed grafts function (DGF) which included Acute Tubular Necrosis (ATN) and Acute Rejection (AR). The analysis included data from 38 NFG, 33 ATN and 23 AR. The parameters calculated were: mean transit time (MTT), the Initial Uptake (IU) and the maximum activity (MA) of the renogram. The results obtained from this analysis show that ln(IU) is the best parameter to classify individuals in either group and that the use of MA or the MTT does not improve the results. Using a cutoff point of ln(IU) = 0.28 and a prevalence of 25% for DGF, the estimated predictive values were 92% for DGF and 99% for NFG.

Acute Disease↗

[Effective renal plasma flow with I-131-hipuran: evaluation of a method with four extractions].

The aim of this work was to evaluate a method for the estimation of the effective renal plasma flow (ERPF) using sodium 131I-o-hippurate (OIH) by means the bicompartmental analysis of the radioactive concentration of 4 plasma samples, analyzing the error obtained respecting to the multi-sample method and comparing it with those obtained with other simplified methods. We calculated the ERPF from 62 patients using the multi-sample method as standard, the method based in a single sample at 44 minutes p.i., a method based in 2 samples from the first exponential, 4 methods based in 2 samples from the second exponential, one method based in 3 samples and 5 methods based in 4 samples (2 from the first exponential and 2 from the second exponential). Each simplified method was compared to the standard method and their absolute error (AE) and standard estimation error (SEE) were calculated. The method based in the 4 samples withdrawn at 4, 10, 30 and 60 minutes p.i. was the best of them with a correlation factor with the standard equal to 0.997, an EA that ranged from -63 ml/min to 49 ml/min (mean: -4 ml/min) and a SEE of 19.5 ml/min.

Body Fluid Compartments↗

Renogram deconvolution in the management of diabetic nephropathy: utility of the measurement of initial tracer uptake.

Our objective was to assess mean transit time (MTT) and initial uptake, both parameters derived from the renal retention function (RRF), in the study of renal function in patients with diabetic nephropathy. We studied 25 patients, 7 with type I diabetes mellitus and 18 with type II diabetes mellitus, all of whom fulfilled the criteria for diabetic nephropathy with proteinuria and/or retinopathy. We found a statistically significant correlation between initial uptake and the other biochemical and renographic parameters studied except proteinuria: serum creatinine (r = 0.66, P < 0.002), creatinine clearance (r = 0.61, P < 0.003), glomerular filtration rate (r = 0.74, P < 0.003) and effective renal plasma flow (r = 0.66, P < 0.003). The other renographic parameters studied (maximal activity of the conventional renogram and MTT of the deconvoluted renogram) did not show any correlation. Initial uptake is a semi-quantitative renographic parameter that can provide complementary information to biochemical data and it may be useful in the management of diabetic nephropathy, especially in patients with high serum creatinine or creatinine clearance.

Adult↗

Evaluation of renographic and metabolic parameters in human kidney transplantation.

BACKGROUND: The aim of this work is to demonstrate that the value of the mean transit time (MTT) obtained from the 99mTc-MAG3 renogram deconvolution is related to the levels of adenine nucleotides determined in cortical biopsies from transplanted kidneys. METHODS: The functional state was estimated by means of the MTT and the initial height (H0) of the renal retention function obtained from the 99mTc-MAG3 renogram deconvolution and by the measure of adenine nucleotides obtained from biopsies. We studied 30 kidney graft recipients, 25 normal functioning grafts (NFG) and 5 with acute tubular necrosis (ATN). RESULTS: The MTT is significantly longer for ATN (p < 0.001). The initial uptake values (H0) are significantly lower for ATN (p < 0.001). The sum of adenine nucleotides (SAN) is significantly greater for NFG than for ATN (p < 0.001). The values of the MTT seem to reflect the energy state of the cells in transplanted kidney. CONCLUSION: The analysis of MTT may be indicative of the functional metabolic recovery and thus it may be predictive of the renal graft function at least in the same extent than the biochemical analysis of a cortical renal biopsy immediately after blood reperfusion of the tissue.

Adenine Nucleotides↗

MAG3 renogram deconvolution in kidney transplantation: utility of the measurement of initial tracer uptake.

UNLABELLED: The study of renal retention function by deconvolution analysis of renographic curves is useful to calculate quantitative parameters in renal studies. The aim of the work is to evaluate the usefulness of 99mTc-MAG3 renogram deconvolution in renal function monitoring of kidney graft recipients. METHODS: Forty-three kidney grafts and 112 renograms were studied: 41 were diagnosed as functioning graft, 35 as acute tubular necrosis, 24 as acute rejection, 8 as obstruction and 4 as cyclosporin toxicity. The parameters calculated were mean transit time (MTT), time at 20% of renal retention function (T20) and initial uptake (IU). RESULTS: MTT and T20 were significantly longer in obstructives than in functioning grafts (p < 0.001). Initial uptake was significantly lower in acute tubular necrosis (ATN) and acute rejection (p < 0.001) and in obstructives (p < 0.05) than in functioning grafts. The joint evaluation of MTT and IU allowed to diagnose cases with graft function severely impaired. CONCLUSION: Initial uptake is useful in evaluating post-transplantation complications and in combination with MTT and T20 reflects renal dysfunction severity.

Adult↗

Simultaneous administration of 99Tcm-HMPAO-labelled autologous leukocytes and 111In-labelled non-specific polyclonal human immunoglobulin G in bone and joint infections.

The aim of this study was to investigate the ability of 111In-labelled human polyclonal immunoglobulin G (111In-IgG) to localize bone and joint infections compared with 99Tcm-HMAPO-labelled leukocytes (99Tcm-WBC). Thirty-four patients routinely referred for investigation of bone and joint infections were studied. In all patients, a bone scan using 99Tcm-MDP was initially obtained. Subsequently, 99Tcm-WBC and 111In-IgG were simultaneously injected and images obtained at 30 min, 4 h and 24 h post-injection. Diagnostic accuracy was established by bacteriology of specimens obtained by needle aspiration and/or surgery, other imaging methods and clinical follow-up. The images were read by three experienced observers blinded to any other information; the clinical suspicion of infection and the diagnosis were established when two observers agreed. Infection was confirmed in 11 patients. The 99Tcm-WBC scans gave 8 true-positive, 5 false-positive, 18 true-negative and 3 false-negative results. With 111In-IgG, the figures were 7, 6, 17 and 4, respectively. The sensitivity, specificity and accuracy were 72.7%, 78.2% and 76.4% respectively for the labelled leukocytes and 63.6%, 73.9% and 70.6% respectively for 111In-IgG. There was greater agreement between the observers with 99Tcm-WBC than 111In-IgG. In this study, 111In-IgG was less sensitive and less specific than 99Tcm-WBC scintigraphy for the diagnosis of chronic infections, but these differences were not significant. Both tracers appear to be useful in the diagnosis of bone and joint infections. However, our results were less reliable for the diagnosis of an infected prosthesis.

Adult↗

99Tcm-MAG3 renogram deconvolution in normal subjects and in normal functioning kidney grafts.

This study provides values of transit times obtained by 99Tcm- mercaptoacetyl triglycine (99Tcm-MAG3) renogram deconvolution for both normal subjects and kidney graft recipients. The analysis included 50 healthy kidney units from 25 volunteers and 28 normal functioning kidney grafts. The parameters calculated for the whole kidney (WK) and for the renal parenchyma (P) were: mean transit time (MTT) and times at 20% (T20) and 80% (T80) of renal retention function initial height. For healthy kidneys the WK MTT was 174 +/- 27 s and P MTT 148 +/- 22 s. The WK T20 values were 230 +/- 33 s and P T20 231 +/- 34 s. The WK T80 was 108 +/- 19 s and P T80 106 +/- 12 s. Whole kidney and parenchymal values of transit times for normal functioning kidney grafts do not present significant differences with respect to healthy kidneys.

Adolescent↗

Evaluation of obstructed kidneys by discriminant analysis of 99mTc-MAG3 renograms.

This study sought to develop a method of improving the differential diagnostic between healthy and obstructed kidneys using only parameters derived from the 99mTc-MAG3 renogram. The analysis included data from 46 healthy and 36 obstructed kidney units. The parameters calculated were: mean transit time (MTT), time at 20% of the initial height of the renal retention function (T20) and time to peak of the renogram (TP). A discriminant analysis was carried out to obtain a discriminant function in order to differentiate between the two groups. The best results were obtained using the function: (2.5629 InT20) + (2.1280 In TP) -27.1224 which correctly classified 97.56% of the cases, giving a sensitivity of 94.44% and a specificity of 99.99%.

Adult↗